Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Skeletal Radiol ; 51(4): 807-817, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34430995

RESUMEN

OBJECTIVE: Solitary fibrous tumors (SFTs) uncommonly occur in the musculoskeletal system, with limited available data on their MRI appearance. This study was performed to assess the MRI features of SFTs in the musculoskeletal system (MSK-SFTs). MATERIALS AND METHODS: Pre-treatment MRI in 39 patients with pathologically proven SFTs in the trunk or extremities was evaluated. Patient demographics, clinical management and follow-up, and lesion histology were reviewed. MRI features including lesion location, size, morphology, signal characteristics, vascularity, and relationship to major neurovascular structures were assessed. RESULTS: MSK-SFTs most frequently occurred in the lower extremity (23/39 cases, 59%), deep to fascia (29/39, 74%), and intermuscular (22/29, 76%) in location. The majority of deep lesions were located along a major neurovascular bundle (20/29, 69%). Lesions had well-defined margins (39/39, 100%), multilobulated contours (27/39, 69%), and measured mean 6.9 ± 2.8 cm. The majority of lesions had slightly hyperintense T1 signal (34/39, 87%) and heterogenous intermediate-to-high T2/STIR signal (28/38, 74%). A "pseudo-cerebriform" internal architectural pattern on fluid-sensitive sequences, with internal lobulations and low signal bands/septations, was observed in 63% (24/38) of lesions. Lesions commonly demonstrated prominent intra-lesional (30/39, 75%) and peripheral juxta-lesional flow voids. Local invasion of surrounding structures was uncommon (3/39, 8%). Mitotically active lesions (p = 0.02) and lesions with tumor necrosis (p < 0.01) were larger in size. Tumor necrosis was associated with T1 heterogeneity (p = 0.04). Distant metastasis occurred in 10% (4/39) of patients, all in mitotically active lesions pre-operatively considered at least at intermediate risk of metastasis. CONCLUSION: MSK-SFTs commonly present as well-defined, hypervascular masses deep to fascia along major neurovascular bundles, with heterogeneous slightly hyperintense T1 signal, intermediate-to-high T2/STIR signal, and prominent macroscopic flow voids.


Asunto(s)
Sistema Musculoesquelético , Tumores Fibrosos Solitarios , Humanos , Imagen por Resonancia Magnética/métodos , Estudios Retrospectivos , Tumores Fibrosos Solitarios/diagnóstico por imagen , Tumores Fibrosos Solitarios/patología
2.
AJR Am J Roentgenol ; 212(5): 1112-1125, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30860884

RESUMEN

OBJECTIVE. Accurate and reproducible MRI assessment of the sacroiliac joint (SIJ) is challenging. Numerous scoring systems have been proposed to facilitate consistent SIJ assessment. The purpose of this article is to evaluate the diagnostic accuracy and reliability of existing MRI-based SIJ scoring systems for the evaluation of spondyloarthropathy. CONCLUSION. Among existing methods, there is fair (grade B) evidence to recommend the Spondyloarthropathy Research Consortium of Canada scoring systems as tools for MRI evaluation of the SIJ. However, limited data on criterion validity limit assessment of scoring system accuracy.

3.
J Rheumatol ; 46(9): 1192-1197, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-30770500

RESUMEN

OBJECTIVE: To develop definitions for the assessment of magnetic resonance imaging (MRI) pathologies of the sacroiliac joints (SIJ) in juvenile idiopathic arthritis. METHODS: An Outcome Measures in Rheumatology (OMERACT) consensus-driven methodology consisting of iterative surveys and focus group meetings within an international group of rheumatologists and radiologists. RESULTS: Two domains, inflammation and structural, were identified. Definitions for bone marrow edema, joint space inflammation, capsulitis, and enthesitis were derived for joint inflammation; sclerosis, erosion, fatty lesion, and ankylosis were defined for assessing structural joint changes. CONCLUSION: Preliminary consensus-driven definitions for inflammation and structural elements have been derived, underpinning the ongoing development of the OMERACT Juvenile Arthritis MRI SIJ scoring system (OMERACT JAMRIS-SIJ).


Asunto(s)
Artritis Juvenil/diagnóstico por imagen , Articulación Sacroiliaca/diagnóstico por imagen , Sacroileítis/diagnóstico por imagen , Humanos , Inflamación/diagnóstico por imagen , Imagen por Resonancia Magnética , Índice de Severidad de la Enfermedad
4.
Hip Int ; 26(6): 602-607, 2016 Nov 10.
Artículo en Inglés | MEDLINE | ID: mdl-27768217

RESUMEN

PURPOSE: Indices from 3-D ultrasound may have a role in developmental dysplasia of the hip (DDH) assessment, but require a way to determine spatial orientation relative to body axes. The lateral iliac wall angle is a potentially suitable reference axis in 3-D ultrasound. We sought to quantify normal values and variations of the infant iliac wall angle on radiography, and compare with computed tomography (CT). METHODS: Acetabular and lateral iliac angles were measured on frontal pelvic radiographs of 200 patients (400 hips, 183 with DDH) and coronal CT of 20 patients (40 hips) aged 0-12 months. Relationships among morphologic indices and demographics were assessed using linear regression, Welch's t-test, Pearson's correlation coefficient (r) and coefficients of variance (CoV). Reliability was assessed using intra-class correlation coefficients (ICC). RESULTS: The radiographic iliac angle averaged 53.0° ± 7.7° (mean ± standard deviation; 95% CI, 38°-68°) in DDH vs. 56.2° ± 6.7° (95% CI, 43°-69°) in normal hips (p<0.001), correlated weakly with age (r = 0.25), and showed no inter-sex differences (p = 0.79). Inter-reader and intra-reader reliability were ICC = 0.946 and 0.965. CT iliac angle had mean difference 5.8° ± 6.2° (p<0.01), CoV = 10% and r = 0.68 vs. corresponding radiographs. CONCLUSIONS: The radiographic infant lateral iliac wall angle has mean value 53-56° in dysplastic and normal hips with consistent range of variation approximately ±15°, was measured with high reliability, does not differ by sex, and is only slightly lower in the youngest infants. The iliac wall angle is an unbiased reference axis that may be suitable to establish general spatial orientation of 3-D hip ultrasound images.


Asunto(s)
Luxación Congénita de la Cadera/diagnóstico por imagen , Ilion/diagnóstico por imagen , Acetábulo/diagnóstico por imagen , Estudios de Casos y Controles , Femenino , Humanos , Imagenología Tridimensional , Lactante , Recién Nacido , Masculino , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X , Ultrasonografía
5.
Can Assoc Radiol J ; 67(4): 368-378, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27245289

RESUMEN

PURPOSE: To minimize the burden of overutilisation of lumbar spine magnetic resonance imaging (MRI) on a resource-constrained public healthcare system, it may be helpful to image some patients with mechanical low-back pain (LBP) using a simplified rapid MRI screening protocol at 1.5-T. A rapid-acquisition 3-dimensional (3D) SPACE (Sampling Perfection with Application-optimized Contrasts using different flip angle Evolution) sequence can demonstrate common etiologies of LBP. We compared lumbar spinal canal stenosis (LSCS) and neural foraminal stenosis (LNFS) assessment on 3D SPACE against conventional 2-dimensional (2D) MRI. METHODS: We prospectively performed 3D SPACE and 2D spin-echo MRI sequences (axial or sagittal T1-weighted or T2-weighted) at 1.5-T in 20 patients. Two blinded readers assessed levels L3-4, L4-5 and L5-S1 using: 1) morphologic grading systems, 2) global impression on the presence or absence of clinically significant stenosis (n = 60 disc levels for LSCS, n = 120 foramina for LNFS). Reliability statistics were calculated. RESULTS: Acquisition time was ∼5 minutes for SPACE and ∼20 minutes for 2D MRI sequences. Interobserver agreement of LSCS was substantial to near perfect on both sequences (morphologic grading: kappa [k] = 0.71 SPACE, k = 0.69 T2-weighted; global impression: k = 0.85 SPACE, k = 0.78 T2-weighted). LNFS assessment had superior interobserver reliability using SPACE than T1-weighted (k = 0.54 vs 0.37). Intersequence agreement of findings between SPACE and 2D MRI was substantial to near perfect by global impression (LSCS: k = 0.78 Reader 1, k = 0.85 Reader 2; LNFS: k = 0.63 Reader 1, k = 0.66 Reader 2). CONCLUSIONS: 3D SPACE was acquired in one-quarter the time as the conventional 2D MRI protocol, had excellent agreement with 2D MRI for stenosis assessment, and had interobserver reliability superior to 2D MRI. These results justify future work to explore the role of 3D SPACE in a rapid MRI screening protocol at 1.5-T for mechanical LBP.


Asunto(s)
Imagenología Tridimensional , Dolor de la Región Lumbar/diagnóstico por imagen , Vértebras Lumbares/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Anciano , Constricción Patológica/diagnóstico por imagen , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Proyectos Piloto , Estudios Prospectivos , Reproducibilidad de los Resultados , Método Simple Ciego , Factores de Tiempo
6.
Orthop J Sports Med ; 4(12): 2325967116673797, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28050574

RESUMEN

BACKGROUND: Anatomic single bundle anterior cruciate ligament (ACL) reconstruction is the current gold standard in ACL reconstructive surgery. However, placement of femoral and tibial tunnels at the anatomic center of the ACL insertion sites can be difficult intraoperatively. We developed a "virtual arthroscopy" program that allows users to identify ACL insertions on preoperative knee magnetic resonance images (MRIs) and generates a 3-dimensional (3D) bone model that matches the arthroscopic view to help guide intraoperative tunnel placement. PURPOSE: To test the validity of the ACL insertion sites identified using our 3D modeling program and to determine the accuracy of arthroscopic ACL reconstruction guided by our "virtual arthroscopic" model. STUDY DESIGN: Descriptive laboratory study. METHODS: Sixteen cadaveric knees were prescanned using routine MRI sequences. A trained, blinded observer then identified the center of the ACL insertions using our program. Eight knees were dissected, and the centers of the ACL footprints were marked with a screw. In the remaining 8 knees, arthroscopic ACL tunnels were drilled into the center of the ACL footprints based on landmarks identified using our virtual arthroscopic model. Postprocedural MRI was performed on all 16 knees. The 3D distance between pre- and postoperative 3D centers of the ACL were calculated by 2 trained, blinded observers and a musculoskeletal radiologist. RESULTS: With 2 outliers removed, the postoperative femoral and tibial tunnel placements in the open specimens differed by 2.5 ± 0.9 mm and 2.9 ± 0.7 mm from preoperative centers identified on MRI. Postoperative femoral and tibial tunnel centers in the arthroscopic specimens differed by 3.2 ± 0.9 mm and 2.9 ± 0.7 mm, respectively. CONCLUSION: Our results show that MRI-based 3D localization of the ACL and our virtual arthroscopic modeling program is feasible and does not show a statistically significant difference to an open arthrotomy approach. However, additional refinements will be required to improve the accuracy and consistency of our model to make this an effective tool for surgeons performing anatomic single-bundle ACL reconstructions. CLINICAL RELEVANCE: Arthroscopic anatomic single-bundle ACL reconstruction is the current gold standard for ACL reconstruction; however, the center of the ACL footprint can be difficult to identify arthroscopically. Our novel modeling can improve the identification of this important landmark intraoperatively and decrease the risk of graft malposition and subsequent graft failure.

7.
J Arthroplasty ; 30(9): 1647-51, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25861919

RESUMEN

Aseptic loosening represents the most common complication associated with hip and knee arthroplasty and is a common indication for surgical revision in the post-arthroplasty population. The optimal imaging methodology in evaluating clinical suspected loosening is not well-defined. Our study retrospectively evaluated nuclear medicine arthrography with hybrid single photon emission computed tomography/computed tomography (SPECT/CT) in 38 patients (21 hip, 17 knee) compared with reference standards of surgical evaluation, spontaneous resolution of symptoms without revision, or a minimum of 1 year clinical and radiographic follow-up. Our study demonstrated a sensitivity of 100%, specificity of 96.0%, PPV of 92.9%, NPV of 100%, and accuracy of 97.4% with this imaging technique suggesting utility of nuclear medicine arthrography with SPECT/CT in the clinical evaluation of suspected aseptic loosening.


Asunto(s)
Artrografía/métodos , Prótesis de la Rodilla , Tomografía Computarizada de Emisión de Fotón Único , Artroplastia de Reemplazo de Rodilla , Humanos , Articulación de la Rodilla , Valor Predictivo de las Pruebas , Falla de Prótesis , Reoperación , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X
8.
Knee Surg Sports Traumatol Arthrosc ; 23(4): 1206-14, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24651978

RESUMEN

PURPOSE: Anatomic placement of anterior cruciate ligament (ACL) grafts at arthroscopic reconstruction can be challenging. Localising ACL attachments on magnetic resonance imaging (MRI) sequences pre-operatively could aid with planning for anatomic graft placement. Though ACL attachments can be identified on two-dimensional (2D) MRI, slice thickness theoretically limits out-of-plane accuracy and a 3D MRI base sequence with smaller isotropic voxels may improve observer reliability in localising ACL attachment locations. The purpose of this study was to test whether a high-resolution 3D sequence improved inter- and intra-observer reliability of ACL attachment localisation compared with conventional 2D MRI for this application. METHODS: Twenty paediatric knees were retrospectively scanned at 1.5 Tesla with multi-planar 2D proton density (slice thickness 3-4 mm) and T2-weighted 3D multiple-echo data image combination gradient echo (isotropic 0.8 mm voxels) sequences. Two observers blinded to each others' findings identified ACL attachments on MRI slices, and 3D reconstructions showing ACL attachments were produced. ACL attachment centre locations and areas were calculated, and reliability assessed. RESULTS: Inter-observer variation of centre locations of ACL attachments identified on 3D versus 2D sequences was not significantly different (mean ± SD): 1.8 ± 0.6 versus 1.5 ± 0.7 mm at femoral attachments, 1.7 ± 0.7 versus 1.5 ± 0.8 mm at tibial attachments (p > 0.05). The 95 % confidence interval for centre locations was <4.0 mm in all cases. Inter-observer reliability of attachment areas was not higher for 3D sequences. CONCLUSIONS: ACL attachment centres were localised with high and similar inter- and intra-observer reliability on a high-resolution 3D and multi-planar conventional 2D sequences. Using this technique, MRI could potentially be used for planning and intra-operative guidance of anatomic ACL reconstruction, whether from 2D or 3D base sequences. Surgeons in clinical practice need not order a lengthy dedicated 3D MRI to localise ligament attachments, but can confidently use a standard 2D MRI for this application. LEVEL OF EVIDENCE: III.


Asunto(s)
Reconstrucción del Ligamento Cruzado Anterior , Ligamento Cruzado Anterior/patología , Imagenología Tridimensional/métodos , Traumatismos de la Rodilla/diagnóstico , Imagen por Resonancia Magnética/métodos , Adolescente , Ligamento Cruzado Anterior/cirugía , Lesiones del Ligamento Cruzado Anterior , Niño , Humanos , Traumatismos de la Rodilla/cirugía , Curva ROC , Reproducibilidad de los Resultados , Estudios Retrospectivos
9.
Ultrasound Med Biol ; 41(1): 56-63, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25438837

RESUMEN

Currently, acetabular rounding is only subjectively assessed on ultrasound for developmental dysplasia of the hip. We tested whether acetabular rounding can be quantified reliably and can distinguish between hips requiring and not requiring treatment. Consecutive infants (n = 90) suspected of having dysplasia of the hip, seen at a pediatric orthopedic clinic, were separated into four diagnostic categories (normal, borderline but resolved, treated by brace, treated surgically). Acetabular rounding was assessed by semi-quantitative grade (0 = nil, 1 = mild, 2 = moderate, 3 = severe) by three observers and by direct measurement of acetabular radius of curvature (AROC) by two observers. Inter-observer reliability of rounding grade was poor (κ = 0.30-0.37). AROC had an inter-observer intra-class correlation coefficient of 0.84 and coefficient of variation of 29%-34%. Mean AROC was significantly higher for hips requiring treatment than for those not requiring treatment (3.3 mm vs. 1.6 mm, p = 0.007). AROC reliably quantifies an observation currently being made subjectively by radiologists and surgeons, and may be useful as a supplementary ultrasound index of dysplasia of the hip in future prospective studies.


Asunto(s)
Acetábulo/anomalías , Acetábulo/diagnóstico por imagen , Puntos Anatómicos de Referencia/diagnóstico por imagen , Luxación de la Cadera/diagnóstico por imagen , Luxación de la Cadera/terapia , Interpretación de Imagen Asistida por Computador/métodos , Ultrasonografía/métodos , Niño , Femenino , Humanos , Lactante , Masculino , Pronóstico , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Resultado del Tratamiento
10.
Radiology ; 273(3): 870-8, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24964047

RESUMEN

PURPOSE: To use three-dimensional ( 3D three-dimensional ) ultrasonography (US) to quantify the alpha-angle variability due to changing probe orientation during two-dimensional ( 2D two-dimensional ) US of the infant hip and its effect on the diagnostic classification of developmental dysplasia of the hip ( DDH developmental dysplasia of the hip ). MATERIALS AND METHODS: In this institutional research ethics board-approved prospective study, with parental written informed consent, 13-MHz 3D three-dimensional US was added to initial 2D two-dimensional US for 56 hips in 35 infants (mean age, 41.7 days; range, 4-112 days), 26 of whom were female (mean age, 38.7 days; range, 6-112 days) and nine of whom were male (mean age, 50.2 days; range, 4-111 days). Findings in 20 hips were normal at the initial visit and were initially inconclusive but normalized spontaneously at follow-up in 23 hips; 13 hips were treated for dysplasia. With the computer algorithm, 3D three-dimensional US data were resectioned in planes tilted in 5° increments away from a central plane, as if slowly rotating a 2D two-dimensional US probe, until resulting images no longer met Graf quality criteria. On each acceptable 2D two-dimensional image, two observers measured alpha angles, and descriptive statistics, including mean, standard deviation, and limits of agreement, were computed. RESULTS: Acceptable 2D two-dimensional images were produced over a range of probe orientations averaging 24° (maximum, 45°) from the central plane. Over this range, alpha-angle variation was 19° (upper limit of agreement), leading to alteration of the diagnostic category of hip dysplasia in 54% of hips scanned. CONCLUSION: Use of 3D three-dimensional US showed that alpha angles measured at routine 2D two-dimensional US of the hip can vary substantially between 2D two-dimensional scans solely because of changes in probe positioning. Not only could normal hips appear dysplastic, but dysplastic hips also could have normal alpha angles. Three-dimensional US can display the full acetabular shape, which might improve DDH developmental dysplasia of the hip assessment accuracy.


Asunto(s)
Luxación Congénita de la Cadera/diagnóstico por imagen , Imagenología Tridimensional , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Lactante , Recién Nacido , Masculino , Estudios Prospectivos , Reproducibilidad de los Resultados , Ultrasonografía
11.
Am J Sports Med ; 42(7): 1644-51, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24755252

RESUMEN

BACKGROUND: To aid in performing anatomic physeal-sparing anterior cruciate ligament (ACL) reconstruction, it is important for surgeons to have reference data for the native ACL attachment positions and epiphyseal anatomy in skeletally immature knees. PURPOSE: To characterize anatomic parameters of the ACL tibial insertion and proximal tibial epiphysis at magnetic resonance imaging (MRI) in a large population of skeletally immature knees. STUDY DESIGN: Cross-sectional study; Level of evidence, 3. METHODS: The ACL tibial attachment site and proximal epiphysis were examined in 570 skeletally immature knees with an intact ACL (age, 6-15 years) using 1.5-T proton density-weighted sagittal MRI; also measured were the tibial anteroposterior diameter; anterior, central, and posterior ACL attachment positions; vertical height of the epiphysis; and maximum oblique epiphyseal depth extending from the ACL tibial attachment center to the tibial tuberosity. RESULTS: In adolescents (11-15 years of age), the center of the ACL's tibial attachment was 51.5% ± 5.7% of the anteroposterior diameter of the tibia, with no significant differences between sexes or age groups (P > .05 in all cases). Mean vertical epiphyseal height was 15.9 ± 1.7 mm in the adolescent group, with significant differences between 11-year-olds (15.2 ± 1.5 mm) and 15-year-olds (16.6 ± 1.6 mm), P < .001, and between males (16.6 ± 1.5 mm) and females (14.8 ± 1.4), P < .001. Mean maximum oblique depth was 30.0 ± 5.3 mm, with a significant difference between 11-year-olds (26.7 ± 4.9 mm) and 15-year-olds (32.7 ± 5.1 mm), P < .001, and between males (29.7 ± 6.4 mm) and females (27.8 ± 5.2 mm), P < .001. The maximum oblique depth occurred at a mean angle of ~50°, and this angle did not change with age or sex. There was a significant moderate correlation (r = 0.39, P < .001) between epiphyseal vertical height and maximum oblique depth. CONCLUSION: The center of the ACL tibial attachment was consistently near 51% of the anteroposterior diameter, regardless of age or sex. The vertical depth of the tibial epiphysis was ~16 mm in adolescents. Maximum oblique depth from ACL attachment was ~30 mm, occurring at a mean angle ~50° regardless of age or sex. The normative values for tibial ACL attachment and epiphyseal anatomy presented here may be helpful in selecting candidates for surgery and in planning surgical approaches for pediatric ACL reconstruction.


Asunto(s)
Reconstrucción del Ligamento Cruzado Anterior/métodos , Ligamento Cruzado Anterior/anatomía & histología , Fémur/anatomía & histología , Articulación de la Rodilla/anatomía & histología , Adolescente , Ligamento Cruzado Anterior/crecimiento & desarrollo , Niño , Estudios Transversales , Epífisis/anatomía & histología , Femenino , Fémur/crecimiento & desarrollo , Humanos , Articulación de la Rodilla/crecimiento & desarrollo , Imagen por Resonancia Magnética , Masculino , Valores de Referencia , Tibia/anatomía & histología , Tibia/crecimiento & desarrollo
12.
Clin Orthop Relat Res ; 472(3): 990-7, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24197395

RESUMEN

BACKGROUND: Delay of as much as 5 months between ACL injury and surgery is known to be associated with increased risk of a medial meniscal tear, but the risk of additional meniscal tear progression with a longer delay to surgery is unclear. QUESTIONS/PURPOSES: We determined the (1) times of injury, MRI, and surgery in adolescents with ACL tears, and whether (2) timing of surgery, or (3) initial integrity of the meniscus seen on MR images predicted development of meniscal tears. METHODS: We reviewed 112 adolescents who were 15 ± 1 years old (mean ± SD) (range, 11-16 years) with a torn ACL. These patients underwent surgical repair from 2005 to 2011 in a Canadian city. We compared dates of injury, MRI, and surgery. A pediatric and musculoskeletal fellowship-trained radiologist reread the MR images, and meniscal injuries were graded according to severity. This was compared with surgical findings described in the operative report. RESULTS: Time after injury to MRI and surgery averaged 77 days (range, 1-377 days) and 342 days (range, 42-1637 days), respectively. Patients with new or worsened medial meniscal tears had waited longer for surgery (445 versus 290 days; p = 0.002). Bucket handle medial meniscal tears were more common in patients with surgery more than 1 year after injury than others (15 of 34 versus 14 of 75; p = 0.013). A medial meniscal tear observed on MR images was a significant covariate for a torn meniscus at surgery (relative risk, 5.7; 95% CI, 2.8-11.6). Medial meniscal survival continued to decline sharply greater than 1 year after injury. CONCLUSIONS: Medial meniscal tears, especially bucket handle tears, increased steadily in frequency more than 1 year after ACL injury. Timely ACL reconstruction may be warranted to reduce the risk of further medial meniscal damage even in patients whose original injury occurred more than 1 year before. LEVEL OF EVIDENCE: Level IV, prognostic study. See the Instructions for Authors for a complete description of levels of evidence.


Asunto(s)
Reconstrucción del Ligamento Cruzado Anterior , Ligamento Cruzado Anterior/cirugía , Traumatismos de la Rodilla/cirugía , Lesiones de Menisco Tibial , Tiempo de Tratamiento , Adolescente , Factores de Edad , Alberta , Análisis de Varianza , Ligamento Cruzado Anterior/patología , Lesiones del Ligamento Cruzado Anterior , Distribución de Chi-Cuadrado , Niño , Progresión de la Enfermedad , Femenino , Humanos , Traumatismos de la Rodilla/diagnóstico , Traumatismos de la Rodilla/etiología , Imagen por Resonancia Magnética , Masculino , Meniscos Tibiales/patología , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo
13.
Arthroscopy ; 29(12): 1954-62, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24286795

RESUMEN

PURPOSE: To determine whether 3-dimensional notch volume, measured with magnetic resonance imaging (MRI), differs significantly between knees with torn and intact anterior cruciate ligaments (ACLs) after sports injury in a skeletally immature pediatric population. METHODS: MRI studies of 50 pediatric patients (age range, 10 to 17 years) with ACL tears were compared with 50 age- and sex-matched intact-ACL control patients. All patients had open physes and underwent MRI after a sports injury. Notch volume was calculated through manual segmentation of notch boundaries seen on axial 1.5-T proton density-weighted images. Two-dimensional (2D) measurements (notch width and notch width index) were made on coronal proton density-weighted MRI studies. Notch volume was compared between groups by use of the Mann-Whitney U test. Pearson correlation coefficients were also calculated between indices. RESULTS: Notch volume was significantly lower in knees with ACL tears than in control knees (5.5 ± 1.1 cm(3)v 6.4 ± 1.5 cm(3), P = .002), whereas 2D notch width and notch width index did not differ significantly between these groups. Girls had significantly smaller notch volumes than boys (5.4 ± 1.2 cm(3)v 6.5 ± 1.3 cm(3), P < .001). Notch volume was not correlated with age but was moderately correlated with 2D notch width (r = 0.485, P < .001). CONCLUSIONS: In adolescent patients with sports injuries, the 3-dimensional notch volume was significantly smaller in knees with ACL tears than in intact-ACL control knees. Notch volume was also significantly smaller in girls than in boys and did not vary significantly with age. LEVEL OF EVIDENCE: Level III, case-control study.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Ligamento Cruzado Anterior/patología , Traumatismos en Atletas/patología , Traumatismos de la Rodilla/diagnóstico , Articulación de la Rodilla/patología , Imagen por Resonancia Magnética/métodos , Adolescente , Estudios de Casos y Controles , Niño , Femenino , Fémur/crecimiento & desarrollo , Fémur/patología , Humanos , Imagenología Tridimensional , Articulación de la Rodilla/crecimiento & desarrollo , Masculino , Tamaño de los Órganos , Reproducibilidad de los Resultados
14.
Am J Sports Med ; 41(6): 1319-29, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23576685

RESUMEN

BACKGROUND: Current techniques of anterior cruciate ligament (ACL) reconstruction focus on the placement of femoral and tibial tunnels at anatomic ACL attachments, which can be difficult to identify intraoperatively. PURPOSE: To determine whether the 3-dimensional (3D) center of ACL attachments can be reliably detected from routine magnetic resonance imaging (MRI) in patients with intact ACLs and whether the reliability of this technique changes if the ACL is torn. STUDY DESIGN: Cohort study (diagnosis); Level of evidence, 3. METHODS: A computer technique was developed in which users identify points along ACL attachments on routine clinical MRI of preoperative knees. These attachments are then displayed on a 3D MRI reconstruction, which can be used as a visual guide for the surgeon during arthroscopic surgery. Thirty-seven pediatric patients (age range, 10-17 years) with ACL tears and 37 controls with intact ACLs were examined. Two blinded observers identified cruciate ligament attachments on routine clinical 1.5-T MRI of knees. From the resulting 3D model, the location of the center of each ligament attachment site and its area were calculated and reliability assessed. RESULTS: Mean interobserver variation of the centers of ACL attachments for the intact versus torn ACL was 1.7 ± 0.9 mm versus 1.8 ± 1.1 mm (femoral) and 1.4 ± 0.9 mm versus 1.7 ± 1.0 mm (tibial), respectively (P > .05). The 95% confidence interval for the center location was at most 4 mm. The identified ACL attachment areas were more variable, with interobserver reliability ranging from fair to excellent by the intraclass correlation coefficient. Overlap of ligament areas between observers for the intact versus torn ACL was 70% ± 15% versus 73% ± 12% (femoral) and 79% ± 9% versus 78% ± 10% (tibial), respectively (P > .05). In all cases, intraobserver reliability was superior to interobserver reliability. CONCLUSION: The 3D locations of ACL tibial and femoral attachment centers were identified from routine clinical MRI with variability averaging less than 2 mm between 2 observers. The margin of error was at most 4 mm, representing the thickness of a single axial MRI slice, whether the ACL was intact or torn. Remnant tissue at attachments allows a reliable assessment even of torn ligaments. Identification of the ligament attachment areas was more user dependent than was identification of the attachment centers.


Asunto(s)
Reconstrucción del Ligamento Cruzado Anterior , Ligamento Cruzado Anterior/anatomía & histología , Imagen por Resonancia Magnética , Programas Informáticos , Adolescente , Ligamento Cruzado Anterior/cirugía , Lesiones del Ligamento Cruzado Anterior , Artroscopía , Niño , Femenino , Fémur/anatomía & histología , Humanos , Imagenología Tridimensional , Masculino , Variaciones Dependientes del Observador , Método Simple Ciego , Tibia/anatomía & histología , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA