Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Am Vet Med Assoc ; 262(5): 635-639, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38452486

RESUMEN

OBJECTIVE: The primary goal was to compare the efficacy of administration of apomorphine (APO) administered by intranasal (IN), transconjunctival (TC), SC and IV routes with ropinirole eye drops for induction of emesis in dogs with a secondary goal to evaluate the time of emesis as well as difficulty in administration. ANIMALS: 125 client-owned dogs. METHODS: Dogs were randomly enrolled between October 1, 2021, and March 30, 2022, into groups of 25: IV APO, IN APO, TC APO, SC APO, and ropinirole eye drops. The IV, SC, and TC groups were dosed at 0.03 mg/kg, the IN group was dosed at 0.06 mg/kg, and the ropinirole group was dosed according to manufacturer guidelines. Data collected included success rate of emesis within 600 seconds, time to emesis, time to administer, and difficulty score. Results were compared to IV with P values and CIs being adjusted for multiple comparisons. RESULTS: Emesis was successful within 600 seconds using IV APO in 22 of 25 dogs. By comparison, IN APO induced emesis in 18 of 25 dogs (P = .63). Ropinirole (14/25), SC APO (6/25), and TC APO (4/25) were significantly less successful (P = .047, P = < .001, and P < 0.001, respectively). When emesis was successful, it occurred most rapidly with TC APO, followed by IN APO and then ropinirole. It was most difficult to administer IV APO and TC APO. CLINICAL RELEVANCE: Similar to IV APO, IN APO was a rapid, easy, and effective method of inducing emesis in dogs and should be considered when IV administration is not possible. Ropinirole was easy to administer but successfully induced emesis less reliably within a 10-minute timeframe. APO administered TC using the commercially compounded injectable formulation was ineffective.

2.
J Am Heart Assoc ; 12(13): e029086, 2023 07 04.
Artículo en Inglés | MEDLINE | ID: mdl-37382139

RESUMEN

Background Severe cardiac cachexia or malnutrition are commonly considered relative contraindications to left ventricular assist device (LVAD) implantation, but post-LVAD prognosis for patients with cachexia is uncertain. Methods and Results Intermacs (Interagency Registry for Mechanically Assisted Circulatory Support) 2006 to 2017 was queried for the preimplantation variable cachexia/malnutrition. Cox proportional hazards modeling examined the relationship between cachexia and LVAD outcomes. Of 20 332 primary LVAD recipients with available data, 516 (2.54%) were reported to have baseline cachexia and had higher risk baseline characteristics. Cachexia was associated with higher mortality during LVAD support (unadjusted hazard ratio [HR], 1.36 [95% CI, 1.18-1.56]; P<0.0001), persisting after adjustment for baseline characteristics (adjusted HR, 1.23 [95% CI, 1.0-1.42]; P=0.005). Mean weight change at 12 months was +3.9±9.4 kg. Across the cohort, weight gain ≥5% during the first 3 months of LVAD support was associated with lower mortality (unadjusted HR, 0.90 [95% CI, 0.84-0.98]; P=0.012; adjusted HR, 0.89 [95% CI, 0.82-0.97]; P=0.006). Conclusions The proportion of LVAD recipients recognized to have cachexia preimplantation was low at 2.5%. Recognized cachexia was independently associated with higher mortality during LVAD support. Early weight gain ≥5% was independently associated with lower mortality during subsequent LVAD support.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Desnutrición , Humanos , Corazón Auxiliar/efectos adversos , Caquexia/etiología , Sistema de Registros , Resultado del Tratamiento , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA