Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
PLoS One ; 11(5): e0154000, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27166955

RESUMEN

BACKGROUND: HIV infection is a concern in the army troupes because of the risk behaviour of the military population. In order to allow regular access to CD4+ T cell enumeration of military personnel as well as their dependents and civilians living with HIV, the Senegalese Army AIDS program is implementing PIMATM Alere technology in urban and semi-urban military medical centres. Validation such device is therefore required prior their wide implementation. The purpose of this study was to compare CD4+ T cell count measurements between the PIMATM Alere to the BD FACSCountTM. METHODOLOGY: We selected a total of 200 subjects including 50 patients with CD4+ T-cells below 200/mm3, 50 between 200 and 350/mm3, 50 between 351 and 500/mm3, and 50 above 500/mm3. CD4+ T-cell count was performed on venous blood using the BD FASCountTM as reference method and the PIMATM Point of Care technology. The mean biases and limits of agreement between the PIMATM Alere and BD FACSCountTM were assessed with the Bland-Altman analysis, the linear regression performed using the Passing-Bablok regression analysis, and the percent similarity calculated using the Scott method. RESULTS: Our data have shown a mean difference of 22.3 cells/mm3 [95%CI:9.1-35.5] between the BD FACSCountTM and PIMATM Alere CD4 measurements. However, the mean differences of the two methods was not significantly different to zero when CD4+ T-cell count was below 350/mm3 (P = 0.76). The Passing-Bablok regression in categorized CD4 counts has also showed concordance correlation coefficient of 0.89 for CD4+ T cell counts below 350/mm3 whilst it was 0.5 when CD4 was above 350/mm3. CONCLUSION: Overall, our data have shown that for low CD4 counts, the results from the PIMATM Alere provided accurate CD4+ T cell counts with a good agreement compared to the FACSCountTM.


Asunto(s)
Recuento de Linfocito CD4/instrumentación , Infecciones por VIH/diagnóstico , Infecciones por VIH/inmunología , Personal Militar , Monitorización Inmunológica/instrumentación , Sistemas de Atención de Punto/normas , Adulto , Anciano , Recuento de Linfocito CD4/métodos , Linfocitos T CD4-Positivos/inmunología , Linfocitos T CD4-Positivos/virología , Femenino , Citometría de Flujo , Infecciones por VIH/prevención & control , Infecciones por VIH/virología , Hospitales Militares/organización & administración , Humanos , Modelos Lineales , Masculino , Persona de Mediana Edad , Monitorización Inmunológica/métodos , Sistemas de Atención de Punto/organización & administración , Asunción de Riesgos , Conducta Sexual/psicología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA