Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Asian J Neurosurg ; 18(2): 333-335, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37397057

RESUMEN

Ventriculoperitoneal (VP) shunts are a common neurosurgical procedure used to treat hydrocephalus. Despite their efficacy, many shunts fail and require revisions. The most common causes of shunt failure include obstruction, infection, migration, and perforation. Extraperitoneal migrations require urgent attention. We present a case of migration to the scrotum, a unique complication that may be present in young patients due to the presence of a patent processus vaginalis. Here, we discuss a case of a 16-month-old male patient with a VP shunt presenting with cerebrospinal fluid (CSF) drainage from his scrotum after an indirect hernia repair. This case represents an important reminder for physicians about the sequelae associated with VP shunt complications, particularly extraperitoneal migration, and brings awareness to the underlying factors that may increase this risk.

2.
Int J Hyperthermia ; 39(1): 1283-1293, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36162814

RESUMEN

BACKGROUND: In stereotactic radiosurgery, isodose lines must be considered to determine how surrounding tissue is affected. In thermal ablative therapy, such as laser interstitial thermal therapy (LITT), transcranial MR-guided focused ultrasound (tcMRgFUS), and needle-based therapeutic ultrasound (NBTU), how the surrounding area is affected has not been well studied. OBJECTIVE: We aimed to quantify the transition zone surrounding the ablation core created by magnetic resonance-guided robotically-assisted (MRgRA) delivery of NBTU using multi-slice volumetric 2-D magnetic resonance thermal imaging (MRTI) and subsequent characterization of the resultant tissue damage using histopathologic analysis. METHODS: Four swine underwent MRgRA NBTU using varying duration and wattage for treatment delivery. Serial MRI images were obtained, and the most representative were overlaid with isodose lines and compared to brain tissue acquired postmortem which underwent histopathologic analysis. These results were also compared to predicted volumes using a finite element analysis model. Contralateral brain tissue was used for control data. RESULTS: Intraoperative MRTI thermal isodose contours were characterized and comprehensively mapped to post-operative MRI images and qualitatively compared with histological tissue sections postmortem. NBTU 360° ablations induced smaller lesion volumes (33.19 mm3; 120 s, 3 W; 30.05 mm3, 180 s, 4 W) versus 180° ablations (77.20 mm3, 120 s, 3 W; 109.29 mm3; 180 s; 4 W). MRTI/MRI overlay demonstrated the lesion within the proximal isodose lines. The ablation-zone was characterized by dense macrophage infiltration and glial/neuronal loss as demonstrated by glial fibrillary acidic protein (GFAP) and neurofilament (NF) absence and avid CD163 staining. The transition-zone between lesion and normal brain demonstrated decreased macrophage infiltration and measured ∼345 microns (n - 3). We did not detect overt hemorrhages or signs of edema in the adjacent spared tissue. CONCLUSION: We successfully performed MRgRA NBTU ablation in swine and demonstrated minimal histologic changes extended past the ablation-zone. The lesion was characterized by macrophage infiltration and glial/neuronal loss which decreased through the transition-zone.


Asunto(s)
Encéfalo , Terapia por Ultrasonido , Animales , Encéfalo/diagnóstico por imagen , Encéfalo/cirugía , Proteína Ácida Fibrilar de la Glía , Hígado , Imagen por Resonancia Magnética/métodos , Porcinos
3.
Int J Hyperthermia ; 38(1): 907-915, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34148489

RESUMEN

BACKGROUND: High-intensity focused ultrasound (HIFU) serves as a noninvasive stereotactic system for the ablation of brain metastases; however, treatments are limited to simple geometries and energy delivery is limited by the high acoustic attenuation of the calvarium. Minimally-invasive magnetic resonance-guided robotically-assisted (MRgRA) needle-based therapeutic ultrasound (NBTU) using multislice volumetric 2-D magnetic resonance thermal imaging (MRTI) overcomes these limitations and has potential to produce less collateral tissue damage than current methods. OBJECTIVE: To correlate multislice volumetric 2-D MRTI volumes with histologically confirmed regions of tissue damage in MRgRA NBTU. METHODS: Seven swine underwent a total of 8 frontal MRgRA NBTU lesions. MRTI ablation volumes were compared to histologic tissue damage on brain sections stained with 2,3,5-triphenyltetrazolium chloride (TTC). Bland-Altman analyses and correlation trends were used to compare MRTI and TTC ablation volumes. RESULTS: Data from the initial and third swine's ablations were excluded due to sub-optimal tissue staining. For the remaining ablations (n = 6), the limits of agreement between the MRTI and histologic volumes ranged from -0.149 cm3 to 0.252 cm3 with a mean difference of 0.052 ± 0.042 cm3 (11.1%). There was a high correlation between the MRTI and histology volumes (r2 = 0.831) with a strong linear relationship (r = 0.868). CONCLUSION: We used a volumetric MRTI technique to accurately track thermal changes during MRgRA NBTU in preparation for human trials. Improved volumetric coverage with MRTI enhanced our delivery of therapy and has far-reaching implications for focused ultrasound in the broader clinical setting.


Asunto(s)
Neoplasias Encefálicas , Ultrasonido Enfocado de Alta Intensidad de Ablación , Terapia por Ultrasonido , Animales , Encéfalo/diagnóstico por imagen , Encéfalo/cirugía , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/cirugía , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Porcinos
4.
Int Symp Med Robot ; 20212021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35789074

RESUMEN

The adoption of robotic image-guided surgeries has enabled physicians to perform therapeutic and diagnostic procedures with less invasiveness and higher accuracy. One example is the MRI-guided stereotactic robotic-assisted surgery for conformal brain tumor ablation, where the robot is used to position and orient a thin probe to target a desired region within the brain. Requirements such as the remote center of motion and precise manipulation, impose the use of complex kinematic structures, which result in non-trivial workspaces in these robots. The lack of workspace visualization poses a challenge in selecting valid entry and target points during the surgical planning and navigation stage. In this paper, we present a surgical planning toolkit called the "NeuroPlan" for our MRI-compatible stereotactic neurosurgery robot developed as a module for 3D Slicer software. This toolkit streamlines the current surgical workflow by rendering and overlaying the robot's reachable workspace on the MRI image. It also assists with identifying the optimal entry point by segmenting the cranial burr hole volume and locating its center. We demonstrate the accuracy of the workspace rendering and burr hole parameter detection through both phantom and MR-images acquired from previously conducted animal studies.

5.
Clin Neurol Neurosurg ; 196: 105967, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32604033

RESUMEN

OBJECTIVE: Minimally invasive dorsal cervical decompression (miDCD) has been reported as a novel alternative to open dorsal decompression techniques such as laminectomy, laminoplasty, or laminectomy and fusion. Only limited data have been presented regarding the effects of a minimally invasive approach on cervical motion and alignment. The object of the current study is to provide a more comprehensive analysis of radiographic outcomes following miDCD. PATIENTS AND METHODS: Thirty-five patients who had undergone miDCD for myelopathy were included. Exclusion criteria included prior cervical spine surgery, prior cervical spine fracture, fusion of the cervical spine during miDCD, and/or acute spinal cord injury. Analysis of x-rays included the following data elements: degrees of flexion, degrees of extension, and total range of motion; C2-C7 angle as a measure of cervical lordosis; C2-C7 sagittal vertical axis; effective lordosis; and C7 slope. Patient reported outcome measures included neck Visual Analog Score (VAS), Neck Disability Index (NDI), SF-12 Physical Component Score (PCS), SF-12 Mental Component Score (MCS), Nurick score, and modified Japanese Orthopedic Association Myelopathy scale (mJOA). RESULTS: Pre-operative to post-operative comparisons of all radiographic parameters - including total range of motion, C2-C7 Cobb angle, C2-C7 sagittal vertical axis, effective lordosis, and C7 slope angle - remained stable. Several clinical outcomes demonstrated statistical improvement, namely neck VAS, Nurick score, mJOA, NDI, and SF-12 PCS. CONCLUSIONS: miDCD can maintain cervical range of motion and alignment better than traditional laminectomy or laminoplasty techniques.


Asunto(s)
Vértebras Cervicales/cirugía , Descompresión Quirúrgica , Rango del Movimiento Articular/fisiología , Enfermedades de la Médula Espinal/cirugía , Anciano , Vértebras Cervicales/diagnóstico por imagen , Vértebras Cervicales/fisiopatología , Evaluación de la Discapacidad , Femenino , Humanos , Laminectomía/métodos , Laminoplastia/métodos , Masculino , Persona de Mediana Edad , Enfermedades de la Médula Espinal/diagnóstico por imagen , Enfermedades de la Médula Espinal/fisiopatología , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
6.
J Neurosurg Pediatr ; : 1-6, 2020 Jan 31.
Artículo en Inglés | MEDLINE | ID: mdl-32005019

RESUMEN

Small-bowel obstruction (SBO) and volvulus as a result of ventriculoperitoneal shunting are a rare phenomenon, especially when resulting in bowel necrosis. The authors report the rare event of SBO, bowel strangulation, and necrosis in a pediatric patient after the abdominal catheter became knotted around his small bowel, and they provide a comprehensive review of the literature. The authors argue that shunt configuration is an important consideration for a patient presenting with SBO, and that symptomatic shunt knotting is a reason for surgical correction.

7.
J Clin Neurosci ; 62: 88-93, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30660480

RESUMEN

Patient-reported outcome measures are increasingly used to access pain, disability, physical function, and mental status to quantify effectiveness of surgical intervention in cervical myelopathy, yet each score has little meaning without established thresholds linked to clinical benefit. We set out to develop thresholds for substantial clinical benefit (SCB) in patients undergoing surgery for cervical myelopathy and to evaluate the effect of length of follow-up on SCB thresholds. Thirty-five patients undergoing spinal surgery for progressive cervical myelopathy were tracked from 2005 to 2015. Observations were categorized into three groups: short-term, intermediate, and long-term, corresponding to average follow-up intervals of 3.8, 9.2, and 29.0 months. SCB thresholds were calculated for neck visual analog score (VAS), Neck Disability Index (NDI), Short Form-12 physical (PCS), SF-12 mental component scores (MCS), and modified Japanese Orthopedic Association score (mJOA) using receiver operating curve analysis with a 5-level patient satisfaction index as the anchor. SCB thresholds for each outcome measure were obtained with a range of areas under the curve indicating varying degrees of discriminatory ability, reported with increasing length of follow-up. NDI and PCS were most discriminatory of SCB at any time period. Stratification of thresholds by length of time revealed a significant effect of follow-up time with NDI but not PCS. NDI and PCS thresholds have significantly strong discriminatory value in identifying patients receiving substantial clinical benefit with regard to cervical myelopathy. When NDI is used to predict outcome, choosing thresholds calibrated for follow-up time is recommended to maximize predictive power.


Asunto(s)
Evaluación de la Discapacidad , Medición de Resultados Informados por el Paciente , Enfermedades de la Médula Espinal/cirugía , Adulto , Anciano , Vértebras Cervicales , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Dimensión del Dolor , Satisfacción del Paciente , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento
9.
Neurosurg Focus ; 40(6): E7, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27246490

RESUMEN

OBJECTIVE Minimally invasive posterior cervical decompression (miPCD) has been described in several case series with promising preliminary results. The object of the current study was to compare the clinical outcomes between patients undergoing miPCD with anterior cervical discectomy and instrumented fusion (ACDFi). METHODS A retrospective study of 74 patients undergoing surgery (45 using miPCD and 29 using ACDFi) for myelopathy was performed. Outcomes were categorized into short-term, intermediate, and long-term follow-up, corresponding to averages of 1.7, 7.7, and 30.9 months, respectively. Mean scores for the Neck Disability Index (NDI), neck visual analog scale (VAS) score, SF-12 Physical Component Summary (PCS), and SF-12 Mental Component Summary (MCS) were compared for each follow-up period. The percentage of patients meeting substantial clinical benefit (SCB) was also compared for each outcome measure. RESULTS Baseline patient characteristics were well-matched, with the exception that patients undergoing miPCD were older (mean age 57.6 ± 10.0 years [miPCD] vs 51.1 ± 9.2 years [ACDFi]; p = 0.006) and underwent surgery at more levels (mean 2.8 ± 0.9 levels [miPCD] vs 1.5 ± 0.7 levels [ACDFi]; p < 0.0001) while the ACDFi patients reported higher preoperative neck VAS scores (mean 3.8 ± 3.0 [miPCD] vs 5.4 ± 2.6 [ACDFi]; p = 0.047). The mean PCS, NDI, neck VAS, and MCS scores were not significantly different with the exception of the MCS score at the short-term follow-up period (mean 46.8 ± 10.6 [miPCD] vs 41.3 ± 10.7 [ACDFi]; p = 0.033). The percentage of patients reporting SCB based on thresholds derived for PCS, NDI, neck VAS, and MCS scores were not significantly different, with the exception of the PCS score at the intermediate follow-up period (52% [miPCD] vs 80% [ACDFi]; p = 0.011). CONCLUSIONS The current report suggests that the optimal surgical strategy in patients requiring dorsal surgery may be enhanced by the adoption of a minimally invasive surgical approach that appears to result in similar clinical outcomes when compared with a well-accepted strategy of ventral decompression and instrumented fusion. The current results suggest that future comparative effectiveness studies are warranted as the miPCD technique avoids instrumented fusion.


Asunto(s)
Vértebras Cervicales/cirugía , Descompresión Quirúrgica/métodos , Enfermedades de la Columna Vertebral/cirugía , Fusión Vertebral/métodos , Adulto , Anciano , Vértebras Cervicales/diagnóstico por imagen , Bases de Datos Factuales/estadística & datos numéricos , Evaluación de la Discapacidad , Femenino , Estudios de Seguimiento , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Curva ROC , Estudios Retrospectivos , Enfermedades de la Columna Vertebral/diagnóstico por imagen , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...