Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
2.
J Cardiovasc Magn Reson ; 25(1): 39, 2023 07 03.
Artículo en Inglés | MEDLINE | ID: mdl-37400886

RESUMEN

BACKGROUND: Multiple right ventricular (RV) metrics have prognostic value in pulmonary hypertension (PH). A cardiac magnetic resonance imaging (CMR) derived global ventricular function index (GFI) provided improved prediction of composite adverse outcome (CAO) in adults with atherosclerosis. GFI has not yet been explored in a PH population. We explored the feasibility of GFI as a predictor of CAO in a pediatric PH population. METHODS: Two center retrospective chart review identified pediatric PH patients undergoing CMR from Jan 2005-June 2021. GFI, defined as the ratio of the stroke volume to the sum of mean ventricular cavity and myocardial volume, was calculated for each patient. CAO was defined as death, lung transplant, Potts shunt, or parenteral prostacyclin initiation after CMR. Cox proportional hazards regression was used to estimate associations and assess model performance between CMR parameters and CAO. RESULTS: The cohort comprised 89 patients (54% female, 84% World Health Organization (WHO) Group 1; 70% WHO-FC ≤ 2; and 27% on parenteral prostacyclin). Median age at CMR was 12 years (IQR 8.1-17). Twenty-one (24%) patients experienced CAO during median follow up of 1.5 years. CAO cohort had higher indexed RV volumes (end systolic-145 vs 99 mL/m2, p = 0.003; end diastolic-89 vs 46 mL/m2, p = 0.004) and mass (37 vs 24 gm/m2, p = 0.003), but lower ejection fraction (EF) (42 vs 51%, p < 0.001) and GFI (40 vs 52%, p < 0.001). Higher indexed RV volumes (hazard ratios [HR] 1.01, CI 1.01-1.02), lower RV EF (HR 1.09, CI 1.05-1.12) and lower RV GFI (HR 1.09, CI 1.05-1.11) were associated with increased risk of CAO. In survival analysis, patients with RV GFI < 43% demonstrated decreased event-free survival and increased hazard of CAO compared to those with RV GFI ≥ 43%. In multivariable models, inclusion of GFI provided improved prediction of CAO compared to models incorporating ventricular volumes, mass or EF. CONCLUSIONS: RV GFI was associated with CAO in this cohort, and inclusion in multivariable models had increased predictive value compared to RVEF. GFI uses readily available CMR data without additional post-processing and may provide additional prognostic value in pediatric PH patients beyond traditional CMR markers.


Asunto(s)
Hipertensión Pulmonar , Disfunción Ventricular Derecha , Adulto , Humanos , Femenino , Niño , Adolescente , Masculino , Estudios Retrospectivos , Factores de Riesgo , Valor Predictivo de las Pruebas , Volumen Sistólico , Función Ventricular Derecha
3.
Pediatr Cardiol ; 42(5): 1102-1110, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33774693

RESUMEN

BACKGROUND: Non-invasive imaging markers in patients with repaired tetralogy of Fallot (rTOF) are still being investigated to inform clinical decision making. Atrial function is a prognostic indicator in many acquired and congenital heart diseases. We sought to examine the relationship between cardiac MRI (CMR)-derived indices of left atrial (LA) function, native left ventricular (LV) T1 values, biventricular systolic function, and exercise capacity in rTOF. METHODS: Sixty-six patients with rTOF without prior pulmonary valve replacement who underwent CMR (median age 18.5 years) were identified. Twenty-one adult rTOF patients (age range 19-32 years) were compared with 20 age-matched healthy volunteers (age range 19-34 years). LA reservoir, conduit, and pump global longitudinal strain (GLS) and strain rate (SR) were determined by tissue tracking. Native LV T1 values were measured on rTOF patients. Pearson correlations were performed to determine bivariate associations. RESULTS: Adult rTOF patients had higher pump GLS, pump:conduit, and pump:reservoir GLS ratios, and lower conduit:reservoir GLS ratio, LV ejection fraction (EF), and right ventricular EF compared to controls (p < 0.001 for each comparison). LA conduit:reservoir GLS and pump:reservoir GLS had correlations to native LV T1 (ρ = 0.26, p = 0.03 and ρ = - 0.26, p = 0.03, respectively). LA reservoir SR had positive correlation to RV EF (ρ = 0.27, p = 0.03). There were no statistically significant correlations between LA function and exercise capacity. CONCLUSIONS: LA function is altered in adolescent and young adult patients with rTOF indicating worse diastolic function and relates to increasing native LV T1 values. Future studies are indicated to investigate the progression of adverse atrial-ventricular interactions and poor outcomes in this population.


Asunto(s)
Función del Atrio Izquierdo , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Ventrículos Cardíacos/fisiopatología , Tetralogía de Fallot/cirugía , Adolescente , Adulto , Estudios de Casos y Controles , Ejercicio Físico , Prueba de Esfuerzo , Femenino , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/fisiopatología , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Estudios Retrospectivos , Volumen Sistólico , Adulto Joven
4.
J Am Heart Assoc ; 9(14): e016308, 2020 07 21.
Artículo en Inglés | MEDLINE | ID: mdl-32633206

RESUMEN

Background Cardiac MRI (CMR) derived ventricular global function index (GFI), a ratio of stroke volume to the sum of mean ventricular cavity and myocardial volumes, has demonstrated improved prediction of clinical outcomes in adults with atherosclerotic disease over ejection fraction. We sought to assess CMR derived GFI and a novel modification that accounts for unique loading conditions in patients with repaired tetralogy of Fallot (rTOF) and determine its correlation with exercise performance. Methods and Results Seventy-five patients with rTOF who underwent CMR were identified. Clinical variables were recorded and biventricular GFI calculated. A right ventricular (RV) effective GFI (eGFI) was derived by incorporating effective stroke volume. Thirty-five pediatric patients were matched with 29 age-matched healthy controls. Twenty-five patients completed cardiopulmonary exercise tests within 6 months of CMR. Stepwise regression models were used to determine univariate and multivariable predictors of indexed and percent predicted peak VO2. Median age at CMR was 20 years (interquartile range, 13-28). Pediatric rTOF patients had lower RV eGFI (P < 0.001), RV ejection fraction (P=0.002), but higher indexed RV end-diastolic and end-systolic volumes (P < 0.001, P < 0.001) compared with controls. Univariate analysis demonstrated a correlation between indexed peak VO2 with RV eGFI (R2=0.32, P=0.004), but with neither RVGFI, RV ejection fraction, indexed RV volumes nor RV mass. RV eGFI remained significantly associated with indexed peak VO2 during multivariable modeling. Conclusions Reduced RV eGFI was associated with reduced exercise capacity in rTOF patients, while RV GFI, RV ejection fraction, indexed RV volumes and mass were not. Our modification of the GFI, RV eGFI, may be a valuable non-invasive marker of cardiac function in rTOF.


Asunto(s)
Técnicas de Imagen Cardíaca/métodos , Tolerancia al Ejercicio , Imagen por Resonancia Magnética/métodos , Tetralogía de Fallot/fisiopatología , Función Ventricular , Adolescente , Adulto , Técnicas de Imagen Cardíaca/estadística & datos numéricos , Estudios de Casos y Controles , Femenino , Humanos , Lactante , Imagen por Resonancia Magnética/estadística & datos numéricos , Masculino , Tetralogía de Fallot/cirugía , Adulto Joven
5.
Pediatr Cardiol ; 41(4): 654-668, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32342149

RESUMEN

Diastolic dysfunction has correlated with adverse outcomes in various forms of unrepaired and repaired or palliated congenital heart disease (CHD). The non-invasive assessment of diastolic function in pediatric and adult patients with CHD remains challenging. Atrial size has a pivotal role in the evaluation of diastolic function; however, a growing body of evidence supports the additional role of atrial function as a more sensitive parameter of ventricular diastolic dysfunction. While the importance of atrial function is becoming clearer in adult acquired heart disease, it remains ambiguous in those with CHD. In this review we set the stage with the current understanding of diastolic function assessment in CHD, followed by insight into atrial form and function including its non-invasive assessment, and conclude with the current knowledge of atrial function in CHD. A general pattern of decrease in reservoir and conduit function with compensatory increase followed by decompensatory decrease in contractile function seems to be the common pathway of atrial dysfunction in most forms of CHD.


Asunto(s)
Función Atrial , Cardiopatías Congénitas/fisiopatología , Diástole , Ecocardiografía Doppler , Femenino , Atrios Cardíacos/fisiopatología , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino
6.
Clin Anat ; 32(8): 1107-1117, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31444826

RESUMEN

We aimed to assess the relationship of the rotational position of the aortic root to its underlying ventricular support, and to the position of the inferior margin of the membranous septum, which serves as a surrogate of the atrioventricular conduction axis. We analyzed 40 normal heart specimens (19 children, 21 adults). The inferior margin of the membranous septum was measured relative to the virtual basal ring. The rotational position of the aortic root was determined by assessing the relationship of the aortic leaflet of the mitral valve to the interleaflet triangle between the non- and left coronary leaflets. The extent of supporting fibrous versus myocardial tissues was measured. We also performed a similar investigation of 30 adult computed tomographic data sets. The median age was 0.25 years (44% male) for children, and 64 years (33% male) for adults. The aortic root was positioned centrally in 22 specimens (55%), rotated counterclockwise in 6 (15%), and clockwise in 12 (30%). In the setting of counterclockwise rotation, 53.4% (median) of the supporting circumference was myocardial, as opposed to 41.4% (median) in those with centrally positioned roots, and 31.9% (median) in those with clockwise rotation (P < 0.0001). The position of the inferior margin of the membranous septum was not associated with the rotational position. Analysis of the 30 adult computed tomographic data sets (median age 66.5 years, 57% male) confirmed the positive relationship between clockwise rotation of the aortic root and an increase in the extent of fibrous as opposed to myocardial support. The rotational position of the aortic root correlates with variation in the extent of its fibrous as opposed to myocardial ventricular support, but not with the position of the inferior margin of the membranous septum relative to the virtual basal ring. Clin. Anat. 32:1107-1117, 2019. © 2019 Wiley Periodicals, Inc.


Asunto(s)
Aorta/anatomía & histología , Corazón/anatomía & histología , Adulto , Anciano , Anciano de 80 o más Años , Aorta/diagnóstico por imagen , Niño , Preescolar , Femenino , Corazón/diagnóstico por imagen , Humanos , Lactante , Recién Nacido , Masculino , Persona de Mediana Edad , Valores de Referencia , Rotación , Adulto Joven
7.
Appl Opt ; 42(16): 3234-40, 2003 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-12790474

RESUMEN

We describe a new and unique method for simultaneous determination of the groove depth and duty cycle of binary diffraction gratings. For a near-normal angle of incidence, the +1 and -1 diffracted orders will behave nearly the same as the duty cycle is varied for a fixed grating depth. The difference in their behavior, quantified as the ratio of their respective diffraction efficiencies, is compared to a look-up table generated by rigorous coupled-wave theory, and the duty cycle of the grating is thus obtained as a function of grating depth. Performing the same analysis for the orthogonal probe-light polarization results in a different functional dependence of the duty cycle on the grating depth. By use of both TE and TM polarizations, the depth and duty cycle for the grating are obtained by the intersection of the functions generated by the individual polarizations. These measurements can also be used to assess qualitatively both the uniformity of the grating and the symmetry of the grating profile. Comparison with scanning electron microscope images shows excellent agreement. This method is advantageous since it can be carried out rapidly, is accurate and repeatable, does not damage the sample, and uses low-cost, commonly available equipment. Since this method consists of only four fixed simple measurements, it is highly suitable for quality control in a manufacturing environment.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...