Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Nucl Med ; 48(4): 501-7, 2007 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-17401085

RESUMEN

UNLABELLED: Medullary thyroid carcinoma (MTC) is a rare endocrine tumor arising from the C-cells of the thyroid gland. Calcitonin is the principal serum tumor marker. A rising calcitonin level after total thyroidectomy for localized disease generally indicates residual, recurrent, or metastatic disease. The role of (18)F-FDG PET in MTC remains somewhat unclear. We reviewed our own experience with (18)F-FDG PET in postthyroidectomy MTC patients with elevated calcitonin. METHODS: From our database, we identified patients with suspected residual, recurrent, or metastatic MTC and elevated calcitonin who had been referred for (18)F-FDG PET between January 2000 and October 2005. (18)F-FDG PET findings were classified as positive or negative on the basis of visual interpretation of the scan. Standardized uptake values (SUVs) were also calculated. The (18)F-FDG PET findings were verified by histopathologic examination, when available, or other imaging studies and clinical follow-up. Any negative (18)F-FDG PET result was considered false-negative. RESULTS: Twenty-eight patients underwent a total of 38 (18)F-FDG PET studies. Calcitonin levels ranged from 106 to 541,000 pg/mL (median, 7,260 pg/mL). There were 23 true-positive, 1 false-positive, and 14 false-negative (18)F-FDG PET scans, yielding an overall sensitivity of 62%. There was no true-positive finding when calcitonin levels were below 509 pg/mL (n = 5). Using an arbitrary cutoff of 1,000 pg/mL, we found that the sensitivity in scans with calcitonin levels greater than 1,000 pg/mL increased to 78% (21/27; 95% confidence interval, 58%-91%). The mean SUV of all lesions with (18)F-FDG uptake was 5.3 +/- 3.2 (range, 2.0-15.9). Among the 14 patients with false-negative (18)F-FDG PET findings, 8 had concurrent anatomic imaging studies and only 2 of these had positive findings. CONCLUSION: (18)F-FDG PET can detect residual, recurrent, or metastatic MTC with a reasonable sensitivity of 78% when the calcitonin level is above 1,000 pg/mL but appears of limited use if the calcitonin level is below 500 pg/mL.


Asunto(s)
Calcitonina/biosíntesis , Carcinoma Medular/diagnóstico , Carcinoma Medular/metabolismo , Fluorodesoxiglucosa F18/farmacocinética , Estadificación de Neoplasias/métodos , Neoplasias de la Tiroides/diagnóstico , Neoplasias de la Tiroides/metabolismo , Anciano , Biomarcadores de Tumor , Reacciones Falso Positivas , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Metástasis de la Neoplasia , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA