Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 290
Filtrar
1.
Dig Endosc ; 2023 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-37702082

RESUMEN

OBJECTIVES: Narrow-band imaging (NBI) contributes to real-time optical diagnosis and classification of colorectal lesions. The Japan NBI Expert Team (JNET) was introduced in 2011. The aim of this study was to explore the diagnostic accuracy of JNET when applied by European and Japanese endoscopists not familiar with this classification. METHODS: This study was conducted by 36 European Society of Gastrointestinal Endoscopy (ESGE) and 49 Japan Gastroenterological Endoscopy Society (JGES) non-JNET endoscopists using still images of 150 lesions. For each lesion, nonmagnified white-light, nonmagnified NBI, and magnified NBI images were presented. In the magnified NBI, the evaluation area was designated by region of interest (ROI). The endoscopists scored histological prediction for each lesion. RESULTS: In ESGE members, the sensitivity, specificity, and accuracy were respectively 73.3%, 94.7%, and 93.0% for JNET Type 1; 53.0%, 64.9%, and 62.1% for Type 2A; 43.9%, 67.7%, and 55.1% for Type 2B; and 38.1%, 93.7%, and 85.1% for Type 3. When Type 2B and 3 were considered as one category of cancer, the sensitivity, specificity, and accuracy for differentiating high-grade dysplasia and cancer from the others were 59.9%, 72.5%, and 63.8%, respectively. These trends were the same for JGES endoscopists. CONCLUSION: The diagnostic accuracy of the JNET classification was similar between ESGE and JGES and considered to be sufficient for JNET Type 1. On the other hand, the accuracy for Types 2 and 3 is not sufficient; however, JNET 2B lesions should be resected en bloc due to the risk of cancers and JNET 3 can be treated by surgery due to its high specificity.

2.
J Gastroenterol ; 58(10): 1003-1014, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37479808

RESUMEN

BACKGROUND: Evidence of small-bowel capsule endoscopy (SBCE) for evaluating lesions in Crohn's disease (CD) is lacking. We aimed to clarify the effectiveness and safety of SBCE in a large sample of patients with CD. METHODS: This multicenter prospective registration study recorded the clinical information and SBCE results of patients with definitive CD (d-CD) or suspected CD (s-CD). The primary outcomes were the rates of successful assessment of disease activity using SBCE, definitive diagnosis of CD, and adverse events. Secondary outcomes were the assessment of SBCE findings in patients with d-CD and s-CD and factors affecting SBCE incompletion and retention; and tertiary outcomes included the association between clinical disease activity or blood examination, endoscopic disease activity, ileal CD, and the questionnaire assessment of patient acceptance of SBCE. RESULTS: Of 544 patients analyzed, 541 underwent SBCE with 7 (1.3%) retention cases. Of 468 patients with d-CD, 97.6% could be evaluated for endoscopic activity. Of 76 patients with s-CD, 15.8% were diagnosed with 'confirmed CD'. CD lesions were more frequently observed in the ileum and were only seen in the jejunum in 3.4% of the patients. Male sex and stenosis were risk factors for incomplete SBCE, and high C-reactive protein levels and stenosis were risk factors for capsule retention. In L1 (Montreal classification) patients, clinical remission was associated with endoscopic remission but showed low specificity and accuracy. The answers to the acceptability questionnaire showed the minimal invasiveness and tolerability of SBCE. CONCLUSION: SBCE is practical and safe in patients with CD.


Asunto(s)
Endoscopía Capsular , Enfermedad de Crohn , Humanos , Masculino , Enfermedad de Crohn/diagnóstico , Constricción Patológica , Japón , Endoscopía Capsular/efectos adversos , Estudios Prospectivos
3.
Dig Endosc ; 35(4): 422-429, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36749036

RESUMEN

The number of artificial intelligence (AI) tools for colonoscopy on the market is increasing with supporting clinical evidence. Nevertheless, their implementation is not going smoothly for a variety of reasons, including lack of data on clinical benefits and cost-effectiveness, lack of trustworthy guidelines, uncertain indications, and cost for implementation. To address this issue and better guide practitioners, the World Endoscopy Organization (WEO) has provided its perspective about the status of AI in colonoscopy as the position statement. WEO Position Statement: Statement 1.1: Computer-aided detection (CADe) for colorectal polyps is likely to improve colonoscopy effectiveness by reducing adenoma miss rates and thus increase adenoma detection; Statement 1.2: In the short term, use of CADe is likely to increase health-care costs by detecting more adenomas; Statement 1.3: In the long term, the increased cost by CADe could be balanced by savings in costs related to cancer treatment (surgery, chemotherapy, palliative care) due to CADe-related cancer prevention; Statement 1.4: Health-care delivery systems and authorities should evaluate the cost-effectiveness of CADe to support its use in clinical practice; Statement 2.1: Computer-aided diagnosis (CADx) for diminutive polyps (≤5 mm), when it has sufficient accuracy, is expected to reduce health-care costs by reducing polypectomies, pathological examinations, or both; Statement 2.2: Health-care delivery systems and authorities should evaluate the cost-effectiveness of CADx to support its use in clinical practice; Statement 3: We recommend that a broad range of high-quality cost-effectiveness research should be undertaken to understand whether AI implementation benefits populations and societies in different health-care systems.


Asunto(s)
Pólipos del Colon , Neoplasias Colorrectales , Humanos , Inteligencia Artificial , Colonoscopía , Endoscopía Gastrointestinal , Diagnóstico por Computador , Pólipos del Colon/diagnóstico , Neoplasias Colorrectales/diagnóstico , Neoplasias Colorrectales/prevención & control
4.
Am J Gastroenterol ; 118(2): 276-283, 2023 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-36449784

RESUMEN

INTRODUCTION: To compare the effectiveness of the novel hemostatic peptide, TDM-621, with that of conventional hemostatic methods in treating intraoperative blood oozing during endoscopic submucosal dissection (ESD). METHODS: This multicenter, open-label, randomized controlled trial involved 227 patients with gastric and rectal epithelial tumors in whom ESD was indicated. Patients in whom the source of blood oozing was difficult to identify with waterjet washing during the procedure and required hemostasis with hemostatic forceps were randomly assigned to the TDM-621 and control groups. The TDM-621 group (in which hemostasis was achieved with TDM-621, followed by coagulation hemostasis with hemostatic forceps, as needed) was compared with the control group (in which hemostasis was achieved with hemostatic forceps). The primary end point was the mean number of coagulations with hemostatic forceps, determined by a blinded independent review committee. The secondary end points were the rate of achievement of hemostasis with only TDM-621, the dosage of TDM-621, and adverse events in the TDM-621 group. RESULTS: The mean number of coagulations with hemostatic forceps was significantly reduced in the TDM-621 group (1.0 ± 1.4) compared with that in the control group (4.9 ± 5.2) ( P < 0.001). The rate of hemostasis achievement with only TDM-621 was 62.2%; the mean dosage of TDM-621 was 1.75 ± 2.14 mL. The rates of grade ≥3 adverse events were 6.2% and 5.0% in the TDM-621 and control groups, respectively. DISCUSSION: TDM-621 is a useful, easily operable hemostatic peptide for treatment of blood oozing during gastric and rectal ESD, with no serious safety concerns.


Asunto(s)
Resección Endoscópica de la Mucosa , Hemostáticos , Humanos , Resección Endoscópica de la Mucosa/efectos adversos , Hemostáticos/uso terapéutico , Resultado del Tratamiento , Hemostasis , Péptidos
5.
Gut ; 72(3): 493-500, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36522150

RESUMEN

BACKGROUND AND AIMS: Greenhouse gases (GHGs) that trap heat in the atmosphere are composed of carbon dioxide (CO2), methane, nitrous oxide and fluorinated gases (synthetic hydrofluorocarbons, perfluorocarbons and nitrogen trifluoride). In the USA, the health sector accounts for 8.5% of total GHG emissions. The primary objective of this systematic review was to critically analyse the carbon emissions data from GI endoscopic activity. DESIGN: The GI endoscopy carbon cycle was evaluated at preprocedural, intraprocedural and postprocedural levels. We performed a systematic literature search of articles published on these issues until 30 June 2022 and discussed these available data on endoscopy unit GHG carbon cycle, barriers to reduce GHG emissions and potential solutions. The inclusion criteria were any full-text articles (observational, clinical trials, brief communications, case series and editorials) reporting waste generation from GI endoscopy. Abstracts, news articles and conference proceedings were excluded. RESULTS: Our search yielded 393 records in PubMed, 1708 in Embase and 24 in Google Scholar. After application of inclusion and exclusion factors, we focused on 9 fulllength articles in detail, only 3 of them were cross-sectional studies (all from the USA), the others reviews or position statements. Therefore, the quality of the studies could not be assessed due to heterogeneity in definitions and amount of emissions. CONCLUSIONS: Recognition of carbon emissions generated by GI endoscopy activity is critical. Although multiple limitations exists for quantification of these emission, there is an urgent need for collecting proper data as well as examining novel methods for reduction of these emissions for a sustainable endoscopic practices in the future.


Asunto(s)
Gases de Efecto Invernadero , Humanos , Gases de Efecto Invernadero/análisis , Efecto Invernadero , Gases/análisis , Óxido Nitroso/análisis , Dióxido de Carbono , Endoscopía
6.
Dig Endosc ; 35(4): 483-491, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36239483

RESUMEN

OBJECTIVES: Endoscopists' abilities to diagnose early gastric cancers (EGCs) vary, especially between specialists and nonspecialists. We developed an artificial intelligence (AI)-based diagnostic support tool "Tango" to differentiate EGCs and compared its performance with that of endoscopists. METHODS: The diagnostic performances of Tango and endoscopists (34 specialists, 42 nonspecialists) were compared using still images of 150 neoplastic and 165 non-neoplastic lesions. Neoplastic lesions included EGCs and adenomas. The primary outcome was to show the noninferiority of Tango (based on sensitivity) over specialists. The secondary outcomes were the noninferiority of Tango (based on accuracy) over specialists and the superiority of Tango (based on sensitivity and accuracy) over nonspecialists. The lower limit of the 95% confidence interval (CI) of the difference between Tango and the specialists for sensitivity was calculated, with >-10% defined as noninferiority and >0% defined as superiority in the primary outcome. The comparable differences between Tango and the endoscopists for each performance were calculated, with >10% defined as superiority and >0% defined as noninferiority in the secondary outcomes. RESULTS: Tango achieved superiority over the specialists based on sensitivity (84.7% vs. 65.8%, difference 18.9%, 95% CI 12.3-25.3%) and demonstrated noninferiority based on accuracy (70.8% vs. 67.4%). Tango achieved superiority over the nonspecialists based on sensitivity (84.7% vs. 51.0%) and accuracy (70.8% vs. 58.4%). CONCLUSIONS: The AI-based diagnostic support tool for EGCs demonstrated a robust performance and may be useful to reduce misdiagnosis.


Asunto(s)
Inteligencia Artificial , Neoplasias Gástricas , Humanos , Estudios Retrospectivos , Neoplasias Gástricas/diagnóstico
7.
Gut ; 71(8): 1488-1514, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35725291

RESUMEN

OBJECTIVE: An international meeting was organised to develop consensus on (1) the landmarks to define the gastro-oesophageal junction (GOJ), (2) the occurrence and pathophysiological significance of the cardiac gland, (3) the definition of the gastro-oesophageal junctional zone (GOJZ) and (4) the causes of inflammation, metaplasia and neoplasia occurring in the GOJZ. DESIGN: Clinical questions relevant to the afore-mentioned major issues were drafted for which expert panels formulated relevant statements and textural explanations.A Delphi method using an anonymous system was employed to develop the consensus, the level of which was predefined as ≥80% of agreement. Two rounds of voting and amendments were completed before the meeting at which clinical questions and consensus were finalised. RESULTS: Twenty eight clinical questions and statements were finalised after extensive amendments. Critical consensus was achieved: (1) definition for the GOJ, (2) definition of the GOJZ spanning 1 cm proximal and distal to the GOJ as defined by the end of palisade vessels was accepted based on the anatomical distribution of cardiac type gland, (3) chemical and bacterial (Helicobacter pylori) factors as the primary causes of inflammation, metaplasia and neoplasia occurring in the GOJZ, (4) a new definition of Barrett's oesophagus (BO). CONCLUSIONS: This international consensus on the new definitions of BO, GOJ and the GOJZ will be instrumental in future studies aiming to resolve many issues on this important anatomic area and hopefully will lead to better classification and management of the diseases surrounding the GOJ.


Asunto(s)
Esófago de Barrett , Reflujo Gastroesofágico , Esófago de Barrett/diagnóstico , Esófago de Barrett/epidemiología , Esófago de Barrett/etiología , Consenso , Unión Esofagogástrica , Humanos , Inflamación , Metaplasia
8.
Dig Endosc ; 34(1): 144-152, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33774877

RESUMEN

OBJECTIVES: The Japan Endoscopy Database Project was initiated to develop the world's largest endoscopy data repository. This study describes the first phase of the colonoscopy project in Japan. METHODS: Data were aggregated offline by integrating information from the endoscopy database software from January 2015 through March 2017. The study population included all patients who underwent colonoscopy at eight centers. RESULTS: A total of 31,395 patients who underwent 38,497 colonoscopy procedures were registered. The majority of procedures were performed for screening (n = 14,156), followed by fecal immunochemical test positivity (n = 3960), abdominal symptoms (n = 3864), post-colorectal surgery surveillance (n = 3431), post-endoscopic treatment surveillance (n = 3757), thorough pre-treatment examination (n = 2822), and therapeutic purposes (n = 6507). In the screening group, advanced cancers, early cancers, and adenomas were diagnosed endoscopically in 2.1%, 1.3%, and 28.7% of cases, respectively, while in the fecal immunochemical test-positive group, they were diagnosed in 2.5%, 1.9%, and 41.6% of cases, respectively. The incidence of complications was 0.177% and 0.152% in the screening and fecal immunochemical test-positive groups, respectively. The therapeutic procedures included 1446 cold forceps polypectomy procedures, 4770 cold snare polypectomy procedures, 368 hot biopsies, 2998 hot snare polypectomy procedures, 9775 endoscopic or piecemeal endoscopic mucosal resections, and 1660 endoscopic submucosal dissections. A total of 173 procedure-related complications (0.82%) occurred in 21,017 therapeutic procedures performed in 15,744 patients. CONCLUSIONS: The first phase of the Japan Endoscopy Database Project established the proportions of the diagnostic and therapeutic colonoscopy procedures, and complication rates in real-world settings.


Asunto(s)
Adenoma , Pólipos del Colon , Neoplasias Colorrectales , Colonoscopía , Humanos , Japón/epidemiología , Sangre Oculta
9.
Dig Endosc ; 34(3): 543-552, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34379849

RESUMEN

BACKGROUND AND AIM: We retrospectively determined the safety and efficacy of the endoscopic delivery (ED) of capsule endoscopes. METHODS: We enrolled 10,156 patients who underwent small bowel capsule endoscopy (SBCE), 3182 who underwent patency capsule (PC), and 1367 who underwent colon capsule endoscopy (CCE), at 11 gastroenterological and nine pediatric centers. RESULTS: Small bowel capsule endoscopies, PCs, and CCEs were endoscopically delivered to 546 (5.4%), 214 (6.7%), and 14 (1.0%) patients, respectively. Only mild complications occurred for 21.6% (167/774), including uneventful mucosal damage, bleeding, and abdominal pain. Successful ED of SBCE to the duodenum or jejunum occurred in 91.8% and 90.7% of patients aged <16 years and ≥16 years, respectively (P = 0.6661), but the total enteroscopy rate was higher in the first group (91.7%) than in the second (76.2%, P < 0.0001), for whom impossible ingestion (87.3%) was significantly more common than prolonged lodging in the stomach (64.2%, P = 0.0010). Successful PC and CCE delivery to the duodenum occurred in 84.1% and 28.6%, thereafter the patency confirmation rate and total colonoscopy rate was 100% and 61.5%, respectively. The height, weight, and age cutoff points in predicting spontaneous ingestion were 132 cm, 24.8 kg, and 9 years 2 months, respectively, in patients aged <16 years. Patients aged ≥16 years could not swallow the SBCEs mainly due to dysphagia (75.0%); those who retained it in the esophagus due to cardiac disease (28.6%), etc. and in the stomach due to diabetes mellitus (15.7%), etc. CONCLUSIONS: This large-scale study supports the safety and efficacy of ED in adult and pediatric patients. UMIN000042020.


Asunto(s)
Endoscopios en Cápsulas , Endoscopía Capsular , Adolescente , Adulto , Endoscopía Capsular/efectos adversos , Niño , Humanos , Intestino Delgado , Japón , Estudios Retrospectivos
10.
13.
Dig Endosc ; 33(7): 1131-1138, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33476415

RESUMEN

OBJECTIVES: To compare the efficacy and safety of oral sulfate solution administered using the same-day dose and the split-dose regimens with those of polyethylene glycol plus ascorbate solution, used for bowel preparation in Japanese patients undergoing colonoscopy. METHODS: This multicenter (n = 13), randomized, active-controlled, colonoscopist- and image evaluator-blinded, noninferiority study with parallel-group comparison recruited 632 patients from December 2018 to June 2019. Of these, 602 patients were divided into the oral sulfate solution same-day dose group (n = 200); oral sulfate solution split-dose group (n = 202); and polyethylene glycol plus ascorbate same-day dose group (n = 200). Differences in the efficacy rates between the polyethylene glycol plus ascorbate group and each oral sulfate solution group were calculated using the asymptotic method. The safety of the oral sulfate solution was evaluated, based on the occurrence of adverse events and reactions. RESULTS: Both oral sulfate solution protocols were confirmed as noninferior to the polyethylene glycol plus ascorbate protocol for bowel-cleansing. The occurrence of adverse reactions was significantly lower in the oral sulfate solution same-day dose group than in the polyethylene glycol plus ascorbate group (P = 0.010). The occurrence of adverse reactions was not significantly different between the oral sulfate solution split-dose and the polyethylene glycol plus ascorbate group. CONCLUSIONS: Oral sulfate solution is not only safe and efficacious but also not inferior to polyethylene glycol plus ascorbate solution (active control). It could be used for bowel preparation in Japanese patients scheduled for colonoscopy (Clinical trial registration number: NCT03794310).


Asunto(s)
Catárticos , Colonoscopía , Catárticos/efectos adversos , Humanos , Japón , Polietilenglicoles/efectos adversos , Sulfatos
14.
Dig Endosc ; 33(1): 151-161, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32215959

RESUMEN

STUDY AIMS: The PillCam patency capsule (PPC) is an Agile tag-less patency capsule used to evaluate gastrointestinal (GI) patency. We determined the appropriate use of PPC to preclude subsequent small bowel capsule endoscopy (SBCE) retention. METHODS: This prospective multicenter study consecutively enrolled patients indicated for SBCE with suspected or established small bowel stenosis. Excretion of an intact PPC or its radiologic visualization in the large bowel was considered GI patency. Primary and secondary study endpoints were SBCE retention rates in patients with confirmed patency and identification of factors associated with patency and SBCE retention, respectively. RESULTS: Of 1096 patients enrolled in the study, patency was confirmed in 976 (89.1%). PPC excretion occurred in 579 patients. Of the remaining 517 patients, patency was confirmed using imaging modalities in 401 (77.5%). SBCE retention occurred in five (0.51%) of 963 patients who underwent SBCE: 1.0% in established Crohn's disease (CD) patients, 0% in suspected CD, 0% in tumors, and 1.6% in patients with obscure GI bleeding, for which PPC localization had been radiographically misinterpreted. The non-confirmation of patency was associated with established CD, stenosis identified using imaging modalities, abdominal fullness, serum albumin levels <4.0 g/dL, and previous small bowel obstruction (adjusted odds ratios: 4.21, 2.60, 2.47, 2.12, and 2.00; 95% confidence intervals: 2.62-6.78, 1.62-4.17, 1.43-4.27, 1.32-3.40, and 1.15-3.47, respectively). CONCLUSIONS: The PillCam™ patency capsule helped preclude SBCE retention in most patients, but its accurate localization was essential for cases without excretion (Study registered the University Hospital Medical Information Network, #UMIN000010513).


Asunto(s)
Endoscopía Capsular , Obstrucción Intestinal , Constricción Patológica , Humanos , Obstrucción Intestinal/diagnóstico por imagen , Japón/epidemiología , Estudios Prospectivos
16.
Dig Endosc ; 32(6): 844-850, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32569438

RESUMEN

Severe Acute Respiratory Syndrome Corona Virus 2 (SARS-CoV-2) is the etiologic agent causing the disease Corona Virus Disease 19 (COVID-19), resulting in a worldwide pandemic. Non-emergent endoscopy services have been disrupted as incidence and hospitalizations were rising. It is anticipated that the peak incidence may be leveling off in many parts of the world, but there is a concern for resurgence of the virus activity. Thus, it is important for endoscopy units to have plans in place during peak times of the epidemic and when resuming endoscopic services as the pandemic wanes. The global endoscopy community is faced with the challenge of providing care during this time. The WEO-COVID guidance task force has provided this resource document based on the current evidence and consensus opinion. These World Endoscopy Organization (WEO) recommendations are meant to guide endoscopists worldwide, should be interpreted in light of specific clinical conditions and resource availability and may not apply in all situations. This guidance document does not supersede the need to check for all local regulations and legislations.


Asunto(s)
COVID-19 , Endoscopía Gastrointestinal/normas , Control de Infecciones/normas , Humanos , Pandemias , Equipo de Protección Personal/normas , SARS-CoV-2
18.
Gastroenterol Res Pract ; 2020: 2417841, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32454813

RESUMEN

BACKGROUND: We developed a novel oblique-tip papillotome (OT-papillotome) to facilitate biliary cannulation during endoscopic retrograde cholangiopancreatography (ERCP). This study was performed to evaluate the utility of the OT-papillotome for contrast-guided cannulation (CGC) and wire-guided cannulation (WGC) during ERCP, compared with standard cannulation by WGC using a standard-tip papillotome (ST-papillotome). METHODS: A prospective study was performed at two centers. CGC with the OT-papillotome (OT-CGC group) was performed at Jikei University Hospital, while WGC was done with the OT-papillotome and ST-papillotome (OT-WGC and ST-WGC groups, respectively) at the University of Malaya Medical Centre. The results of the OT-CGC and OT-WGC groups were compared with those of the ST-WGC group after performing coarsened exact matching (CEM) to reduce bias due to nonrandomized and center-based patient allocation. RESULTS: Eighty patients were enrolled in each of the OT-CGC, OT-WGC, and ST-WGC groups. After CEM, the successful biliary cannulation rate was significantly higher in the OT-CGC and OT-WGC groups than in the ST-WGC group, while rescue cannulation was reduced. The mean number of unintended pancreatic access events in the OT-WGC and OT-CGC groups was similar to the ST-WGC group. However, it was significantly lower in the OT-WGC group than in the OT-CGC group. Multivariate analysis revealed that the OT-papillotome was independently associated with less frequent rescue cannulation and a higher successful biliary cannulation rate. CONCLUSIONS: Although use of the OT-papillotome in biliary cannulation did not reduce unintended pancreatic access events or PEP compared to the ST-papillotome, the OT-papillotome increased the successful biliary cannulation rate, while reducing the frequency of rescue cannulation procedures. Combining the OT-papillotome with WGC might be the best cannulation technique for minimizing unintended pancreatic access.

19.
Dig Endosc ; 32(5): 651-657, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32470171

RESUMEN

Some situations may require endoscopy during the COVID-19 (Coronavirus Disease 2019) pandemic. Here, we describe the necessary precautions in the form of clinical questions and answers (Q&A) regarding the safe deployment of gastrointestinal endoscopy in such situations while protecting endoscopy staff and patients from infection. Non-urgent endoscopy should be postponed. The risk of infection in patients should be evaluated in advance by questionnaire and body temperature. The health of staff must be checked every day. Decisions to employ endoscopy should be based on the institutional conditions and aims of endoscopy. All endoscopic staff need to wear appropriate personal protective equipment (PPE). The endoscope and other devices should be cleaned and disinfected after procedures in accordance with the relevant guidelines. Optimal management of the endoscopy unit is required. Endoscopy for infected patients or those with suspected infection demands exceptional caution. When a patient who undergoes endoscopy is later found to have COVID-19, the members of staff involved are considered exposed to the virus and must not work for at least 14 days if their PPE is considered insufficient. When PPE resources are limited, some equipment may be used continuously throughout a shift as long as it is not contaminated. Details of the aforementioned protective measures are described.


Asunto(s)
Infecciones por Coronavirus/prevención & control , Endoscopía Gastrointestinal/métodos , Transmisión de Enfermedad Infecciosa de Paciente a Profesional/prevención & control , Pandemias/prevención & control , Equipo de Protección Personal/estadística & datos numéricos , Neumonía Viral/prevención & control , COVID-19 , Infecciones por Coronavirus/epidemiología , Endoscopía Gastrointestinal/efectos adversos , Femenino , Humanos , Control de Infecciones/métodos , Masculino , Salud Laboral , Pandemias/estadística & datos numéricos , Neumonía Viral/epidemiología , Administración de la Seguridad , Encuestas y Cuestionarios
20.
Dig Endosc ; 32(5): 648-650, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32335946

RESUMEN

All gastrointestinal endoscopic procedures have a high risk of aerosol contamination of the coronavirus disease 2019 (COVID-19) to endoscopists, nurses, and healthcare assistants. Given the current pandemic situation of COVID-19, the Japan Gastroenterological Endoscopy Society issued the recommendation for gastrointestinal (GI) endoscopy based on the status of COVID-19 as of April 9, 2020, in Japan: (i) indications for GI endoscopy in the pandemic of COVID-19; (ii) practical protective equipment for medical personnel depending on the risk for COVID-19; (iii) preprocedural management, such as pharyngeal local anesthesia using lidocaine spray which has a potential to generate the aerosols; (iv) ideal settings of the endoscopy room including the numbers of the staff and the patients; (v) postprocedural management, such as undressing and follow-up of the patients, as well as the involved staff, were documented to fit the practical scenarios in GI endoscopy, with the available data in Japan and the world. We believe that certain measures will prevent further spread of COVID-19.


Asunto(s)
Infecciones por Coronavirus/prevención & control , Endoscopía Gastrointestinal/normas , Transmisión de Enfermedad Infecciosa de Paciente a Profesional/prevención & control , Pandemias/prevención & control , Equipo de Protección Personal/estadística & datos numéricos , Neumonía Viral/prevención & control , Guías de Práctica Clínica como Asunto , COVID-19 , Femenino , Humanos , Control de Infecciones/métodos , Japón , Masculino , Salud Laboral , Sociedades Médicas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...