Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
J Chromatogr A ; 1716: 464645, 2024 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-38219625

RESUMEN

Alkylphosphonofluoridic Acids (APFA) are the major thermal degradation products of G- and A-series nerve agents and thus play a vital role in the verification analysis of Chemical Weapons Convention. Present study focuses on the development of sample clean-up, derivatization procedures and gas chromatography tandem mass spectrometric analysis of APFA in aqueous samples. APFA were found to be much more delicate than the corresponding alkylphosphonic acids and thus required subtle optimizations. Retention of analytes on silica and polymer-based anion exchangers followed by elution under alkaline conditions yielded best recoveries. Elution under acidic conditions led to partial or complete degradation of the analytes to alkylphosphonic acids. Silylation reactions, particularly with MTBSTFA were found the best in terms of chromatographic responses and resolution of the derivative peaks. Methylations with diazomethane, which requires acidic reaction media, failed to produce desired yields of the derivatives. Under optimized conditions, the analytes produced the recoveries ranging from 76.9 to 94.5% with RSD ≤9.2%. The best LOD's in the tandem mass spectrometric analysis ranged from 13 to 56 ng/ml. The applicability of the method was tested by spiking the analytes in the retained aqueous samples received for the 52nd proficiency test conducted by the Organization for the Prohibition of Chemical Weapons (OPCW).


Asunto(s)
Sustancias para la Guerra Química , Agentes Nerviosos , Agentes Nerviosos/análisis , Cromatografía de Gases y Espectrometría de Masas/métodos , Sustancias para la Guerra Química/análisis , Límite de Detección , Espectrometría de Masas en Tándem , Ácidos , Agua/química
2.
Anal Methods ; 12(48): 5839-5845, 2020 12 23.
Artículo en Inglés | MEDLINE | ID: mdl-33227115

RESUMEN

A novel, simple and efficient analytical method for GC-MS based identification of cyanide has been developed using a single step nucleophilic substitution based derivatization of cyanide in aqueous medium. The nucleophilic substitution reaction of cyanide with S-phenyl benzenethiosulfonate results in the formation of phenyl thiocyanate as a cyanide derivative and it was found that the relative response of the resultant cyanide derivative was much higher than that of the cyanide derivatives resulting from disulfide based derivatizing agents. The sample preparation protocol for the identification of cyanide in aqueous samples was also optimized with the new derivatizing agent. Derivatization followed by liquid-liquid extraction was employed for the preparation of aqueous samples containing cyanide salts. The resultant samples were subjected to GC-MS analysis for the identification of the cyanide derivative. Under optimized conditions, the detection and quantification limits for cyanide aqueous samples were found to be 0.075 µg mL-1 and 0.25 µg mL-1 respectively. The calibration curve had a linear relationship with y = 0.086x - 0.076 and r2 = 0.997 for the working range of 0.25 µg mL-1 to 50 µg mL-1. The intraday RSDs were between 2.24 and 8.17%, and the interday RSDs were between 2.22 and 12.85%. The method can also be successfully employed for the identification of hydrogen cyanide in aqueous medium. The applicability of the present method was demonstrated by analysing a real sample from apple seed extraction.

3.
J Chromatogr A ; 1448: 32-41, 2016 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-27113675

RESUMEN

A simple, sensitive and low temperature sample preparation method is developed for detection and identification of Chemical Warfare Agents (CWAs) and scheduled esters in organic liquid using magnetic dispersive solid phase extraction (MDSPE) followed by gas chromatography-mass spectrometry analysis. The method utilizes Iron oxide@Poly(methacrylic acid-co-ethylene glycol dimethacrylate) resin (Fe2O3@Poly(MAA-co-EGDMA)) as sorbent. Variants of these sorbents were prepared by precipitation polymerization of methacrylic acid-co-ethylene glycol dimethacrylate (MAA-co-EGDMA) onto Fe2O3 nanoparticles. Fe2O3@poly(MAA-co-EGDMA) with 20% MAA showed highest recovery of analytes. Extractions were performed with magnetic microspheres by MDSPE. Parameters affecting the extraction efficiency were studied and optimized. Under the optimized conditions, method showed linearity in the range of 0.1-3.0µgmL(-1) (r(2)=0.9966-0.9987). The repeatability and reproducibility (relative standard deviations (RSDs) %) were in the range of 4.5-7.6% and 3.4-6.2% respectively for organophosphorous esters in dodecane. Limits of detection (S/N=3/1) and limit of quantification (S/N=10/1) were found to be in the range of 0.05-0.1µgmL(-1) and 0.1-0.12µgmL(-1) respectively in SIM mode for selected analytes. The method was successfully validated and applied to the extraction and identification of targeted analytes from three different organic liquids i.e. n-hexane, dodecane and silicon oil. Recoveries ranged from 58.7 to 97.3% and 53.8 to 95.5% at 3µgmL(-1) and 1µgmL(-1) spiking concentrations. Detection of diethyl methylphosphonate (DEMP) and O-Ethyl S-2-diisopropylaminoethyl methylphosphonothiolate (VX) in samples provided by the Organization for Prohibition of Chemical Weapons Proficiency Test (OPCW-PT) proved the utility of the developed method for the off-site analysis of CWC relevant chemicals.


Asunto(s)
Alcanos/química , Sustancias para la Guerra Química/análisis , Hexanos/química , Organofosfonatos/análisis , Compuestos Organotiofosforados/análisis , Aceites de Silicona/química , Compuestos Férricos/química , Cromatografía de Gases y Espectrometría de Masas/instrumentación , Cromatografía de Gases y Espectrometría de Masas/métodos , Magnetismo , Ácidos Polimetacrílicos/química , Reproducibilidad de los Resultados , Extracción en Fase Sólida/métodos
4.
J Chromatogr A ; 1434: 39-49, 2016 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-26814366

RESUMEN

Magnetic hydrophilic-lipophilic balance (MHLB) hybrid resin was prepared by precipitation polymerization using N-vinylpyrrolidone (PVP) and divinylbenzene (DVB) as monomers and Fe2O3 nanoparticles as magnetic material. These resins were successfully applied for the extraction of chemical warfare agents (CWAs) and their markers from water samples through magnetic dispersive solid-phase extraction (MDSPE). By varying the ratios of monomers, resin with desired hydrophilic-lipophilic balance was prepared for the extraction of CWAs and related esters of varying polarities. Amongst different composites Fe2O3 nanoparticles coated with 10% PVP+90% DVB exhibited the best recoveries varying between 70.32 and 97.67%. Parameters affecting the extraction efficiencies, such as extraction time, desorption time, nature and volume of desorption solvent, amount of extraction sorbent and the effect of salts on extraction were investigated. Under the optimized conditions, linearity was obtained in the range of 0.5-500 ng mL(-1) with correlation ranging from 0.9911-0.9980. Limits of detection and limits of quantification were 0.5-1.0 and 3.0-5.0 ng mL(-1) respectively with RSDs varying from 4.88-11.32% for markers of CWAs. Finally, the developed MDSPE method was employed for extraction of analytes from water samples of various sources and the OPCW proficiency test samples.


Asunto(s)
Sustancias para la Guerra Química/aislamiento & purificación , Interacciones Hidrofóbicas e Hidrofílicas , Fenómenos Magnéticos , Extracción en Fase Sólida/métodos , Contaminantes Químicos del Agua/aislamiento & purificación , Sustancias para la Guerra Química/análisis , Compuestos Férricos/química , Cromatografía de Gases y Espectrometría de Masas , Límite de Detección , Pirrolidinonas/química , Contaminantes Químicos del Agua/análisis
5.
J Chromatogr A ; 1426: 16-23, 2015 Dec 24.
Artículo en Inglés | MEDLINE | ID: mdl-26639217

RESUMEN

In this work, a glass capillary based microfluidic electromembrane extraction (µ-EME) was demonstrated for the first time. The device was made by connecting an auxillary borosilicate glass tubing (O.D. 3mm, I.D. 2mm) perpendicular to main borosilicate glass capillary just below one end of the capillary (O.D. 8mm, I.D. 1.2mm). It generated the distorted T-shaped device with inlet '1' and inlet '2' for the introduction of sample and acceptor solutions, respectively. At one end of this device (inlet '2'), a microsyringe containing acceptor solution along with hollow fiber (O.D. 1000µm) was introduced. This configuration creates the micro-channel between inner wall of glass capillary and outer surface of hollow fiber. Sample solution was pumped into the system through another end of glass capillary (inlet '1'), with a micro-syringe pump. The sample was in direct contact with the supported liquid membrane (SLM), consisted of 20% (w/w) di-(2-ethylhexyl)phosphate in 2-nitrophenyl octyl ether immobilized in the pores of the hollow fiber. In the lumen of the hollow fiber, the acceptor phase was present. The driving force for extraction was direct current (DC) electrical potential sustained over the SLM. Highly polar (logP=-2.5 to 1.4) basic degradation products of nitrogen mustard and VX were selected as model analytes. The influence of chemical composition of SLM, extraction time, voltage and pH of donor and acceptor phase were investigated. The model analytes were extracted from 10µL of pure water with recoveries ranging from 15.7 to 99.7% just after 3min of operation time. Under optimized conditions, good limits of detection (2-50ngmL(-1)), linearity (from 5-1000 to 100-1000ngmL(-1)), and repeatability (RSDs below 11.9%, n=3) were achieved. Applicability of the proposed µ-EME was proved by recovering triethanolamine (31.3%) from 10µL of five times diluted original water sample provided by the Organization for the Prohibition of Chemical Weapons during 28th official proficiency test.


Asunto(s)
Mecloretamina/aislamiento & purificación , Microfluídica/instrumentación , Microfluídica/métodos , Compuestos Organotiofosforados/aislamiento & purificación , Agua/química , Electricidad , Éteres/química , Vidrio , Mecloretamina/química , Membranas Artificiales , Organofosfatos/química , Compuestos Organotiofosforados/química
6.
J Chromatogr A ; 1423: 54-62, 2015 Dec 04.
Artículo en Inglés | MEDLINE | ID: mdl-26554296

RESUMEN

Present study aimed at graphene surface modification to achieve selective analyte binding in dispersive solid phase extraction. Magnetic graphene - polystyrene sulfonic acid (MG-PSS) cation exchange nano-composite was prepared by non-covalent wrapping method. Composite was characterized by FT-IR and zeta potential. Material exhibited good dispersion in water and high exchange capacity of 1.97±0.16mMg(-1). Prepared nano-sorbent was then exploited for the cation exchange extraction and gas chromatography mass spectrometric analysis of Chemical Weapons Convention relevant aminoalcohols and ethanolamines from aqueous samples. Extraction parameters such as sorbent amount, extraction time, desorption conditions and sample pH were optimized and effect of common matrix interferences such as polyethylene glycol and metal salts was also studied. Three milligram of sorbent per mL of sample with 20min of extraction time at room temperature afforded 70-81% recoveries of the selected analytes spiked at concentration level of 1µgmL(-1). Method showed good linearity in the studied range with r(2)≥0.993. The limits of detection and limits of quantification ranged from 23 to 54ngmL(-1) and 72 to 147ngmL(-1), respectively. The relative standard deviation for intra- and inter-day precision ranged from 4.6 to 10.2% and 7.4 to 14.8% respectively. Applicability of the method to different environmental samples as well as the proficiency tests conducted by the Organization for the Prohibition of Chemical Weapons (OPCW) was also ascertained.


Asunto(s)
Amino Alcoholes/aislamiento & purificación , Monitoreo del Ambiente/métodos , Etanolaminas/aislamiento & purificación , Grafito/química , Nanocompuestos/química , Poliestirenos/química , Agua/química , Amino Alcoholes/análisis , Etanolaminas/análisis , Cromatografía de Gases y Espectrometría de Masas , Extracción en Fase Sólida , Espectroscopía Infrarroja por Transformada de Fourier , Contaminantes Químicos del Agua/análisis
7.
Anal Chem ; 87(13): 6875-80, 2015 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-26054007

RESUMEN

Sulfur monochloride (S2Cl2) and sulfur dichloride (SCl2) are important precursors of the extremely toxic chemical warfare agent sulfur mustard and classified, respectively, into schedule 3.B.12 and 3.B.13 of the Chemical Weapons Convention (CWC). Hence, their detection and identification is of vital importance for verification of CWC. These chemicals are difficult to detect directly using chromatographic techniques as they decompose and do not elute. Until now, the use of gas chromatographic approaches to follow the derivatized sulfur chlorides is not reported in the literature. The electrophilic addition reaction of sulfur monochloride and sulfur dichloride toward 3-hexyne was explored for the development of a novel derivatization protocol, and the products were subjected to gas chromatography-mass spectrometric (GC-MS) analysis. Among various unsaturated reagents like alkenes and alkynes, symmetrical alkyne 3-hexyne was optimized to be the suitable derivatizing agent for these analytes. Acetonitrile was found to be the suitable solvent for the derivatization reaction. The sample preparation protocol for the identification of these analytes from hexane spiked with petrol matrix was also optimized. Liquid-liquid extraction followed by derivatization was employed for the identification of these analytes from petrol matrix. Under the established conditions, the detection and quantification limits are 2.6 µg/mL, 8.6 µg/mL for S2Cl2 and 2.3 µg/mL, 7.7 µg/mL for SCl2, respectively, in selected ion monitoring (SIM) mode. The calibration curve had a linear relationship with y = 0.022x - 0.331 and r(2) = 0.992 for the working range of 10 to 500 µg/mL for S2Cl2 and y = 0.007x - 0.064 and r(2) = 0.991 for the working range of 10 to 100 µg/mL for SCl2, respectively. The intraday RSDs were between 4.80 to 6.41%, 2.73 to 6.44% and interday RSDs were between 2.20 to 7.25% and 2.34 to 5.95% for S2Cl2 and SCl2, respectively.


Asunto(s)
Sustancias para la Guerra Química/análisis , Compuestos de Azufre/química
8.
J Chromatogr A ; 1395: 48-56, 2015 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-25863924

RESUMEN

A sample preparation method involving extraction, enrichment and derivatization of acidic degradation products of nerve agents was developed using magnetic strong anion exchange resins (MSAX). The method was performed in a single vial involving magnetic dispersive solid phase extraction (MDSPE). Analytes were derivatized with N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA) in the presence of resins. MSAX were custom synthesized using Fe3O4 nanoparticles as core, 4-vinylpyridine-co-divinylbenzene as polymer shell and quaternary pyridinium function as anion-exchanger. Hydroxide ions were the counter-anions of MSAX to effectively capture the acidic alkyl alkylphosphonic acids (AAPAs) and alkylphosphonic acids (APAs). Quantitative measurements of analytes were performed in the selected ion monitoring mode of GC-MS. Full scan mode of analysis was followed for identifications. Under the optimized conditions analytes were recovered in the range of 39.7-98.8% (n=3, relative standard deviations (RSD) from 0.3 to 6.5%). Limits of detection (LODs) were in the range of 0.1-1.1ngmL(-1); and the linear dynamic range was 5-1000ngmL(-1) with r(2) of 0.9977-0.9769. Applicability of the method was tested with rain-, tap-, muddy-water and Organization for Prohibition of Chemical Weapons (OPCW) Proficiency Test samples.


Asunto(s)
Resinas de Intercambio Aniónico/química , Sustancias para la Guerra Química/análisis , Monitoreo del Ambiente/métodos , Fenómenos Magnéticos , Extracción en Fase Sólida/métodos , Compuestos Férricos/química , Cromatografía de Gases y Espectrometría de Masas , Límite de Detección , Nanopartículas del Metal/química , Agua/química
9.
J Chromatogr A ; 1394: 9-17, 2015 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-25828545

RESUMEN

Present study deals with the preparation and evaluation of graphene based magnetic nano-composite for dispersive solid phase extraction of Chemical Weapons Convention (CWC) relevant chemicals from aqueous samples. Nano-composite, Fe3O4@SiO2-G was synthesized by covalently bonding silica coated Fe3O4 onto the graphene sheets. Nerve agents (NA), Sulfur mustard (SM) and their non-toxic environmental markers were the target analytes. Extraction parameters like amount of sorbent, extraction time and desorption conditions were optimized. Dispersion of 20 milligram of sorbent in 200mL of water sample for 20min. followed by methanol/chloroform extraction produced average to good recoveries (27-94%) of targeted analytes. Recoveries of real agents exhibited great dependency upon sample pH and ionic strength. Sarin produced maximum recovery under mild acidic conditions (56% at pH 5) while VX demanded alkaline media (83% at pH 9). Salts presence in the aqueous samples was found to be advantageous, raising the recoveries to as high as 94% for SM. Excellent limits of detection (LOD) for sulphur mustard and VX (0.11ngmL(-1) and 0.19ngmL(-1) respectively) proved the utility of the developed method for the off-site analysis of CWC relevant chemicals.


Asunto(s)
Sustancias para la Guerra Química/aislamiento & purificación , Compuestos Férricos , Grafito , Nanocompuestos , Dióxido de Silicio , Extracción en Fase Sólida/métodos , Contaminantes Químicos del Agua/aislamiento & purificación , Concentración de Iones de Hidrógeno , Límite de Detección , Gas Mostaza/aislamiento & purificación , Compuestos Organofosforados/aislamiento & purificación , Concentración Osmolar , Agua/química
10.
J Chromatogr A ; 1370: 80-92, 2014 Nov 28.
Artículo en Inglés | MEDLINE | ID: mdl-25454132

RESUMEN

Environmental markers of chemical warfare agents (CWAs) comprise millions of chemical structures. The simultaneous detection and identification of these environmental markers poses difficulty due to their diverse chemical properties. In this work, by using ultra-high performance liquid chromatography-quadrupole time-of-flight mass spectrometry (UHPLC-QTOF), a generic analytical method for the detection and identification of wide range of environmental markers of CWAs (including precursors, degradation and co-products of nerve agents and sesqui-mustards) in drinking water, was developed. The chromatographic analysis of 55 environmental markers of CWAs including isomeric and isobaric compounds was accomplished within 20 min, using 1.8 µm particle size column. Subsequent identification of the compounds was achieved by the accurate mass measurement of either protonated molecule [M+H](+) or ammonium adduct [M+NH4](+) and fragment ions. Isomeric and isobaric compounds were distinguished by chromatographic retention time, characteristic fragment ions generated by both in-source collision induced dissociation (CID) and CID in the collision cell by MS/MS experiments. The exact mass measurement errors for all ions were observed less than 3 ppm with internal calibration. The method limits of detection (LODs) and limits of quantification (LOQs) were determined in drinking water and found to be 1-50 ng mL(-1) and 5-125 ng mL(-1), respectively. Applicability of the proposed method was proved by determining the environmental markers of CWAs in aqueous samples provided by Organization for the Prohibition of Chemical Weapons during 34th official proficiency test.


Asunto(s)
Sustancias para la Guerra Química/análisis , Cromatografía Líquida de Alta Presión/métodos , Agua Potable/química , Profármacos/análisis , Espectrometría de Masas en Tándem/métodos , Contaminantes Químicos del Agua/análisis , Sustancias para la Guerra Química/química , Límite de Detección , Profármacos/química , Contaminantes Químicos del Agua/química
11.
Chem Commun (Camb) ; 50(82): 12363-6, 2014 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-25186207

RESUMEN

A new chemodosimetric protocol based on a tandem S-alkylation followed by desulfurisation reaction of rhodamine-thioamide with mustard gas is reported. The chemodosimeter is highly selective for potential DNA alkylating agents like sulfur mustard, over other simple alkyl halides with the limit of detection of 4.75 µM.

12.
J Chromatogr A ; 1359: 325-9, 2014 Sep 12.
Artículo en Inglés | MEDLINE | ID: mdl-25103280

RESUMEN

This study deals with the solid supported in situ derivatization extraction of acidic degradation products of nerve agents present in aqueous samples. Target analytes were alkyl alkylphosphonic acids and alkylphosphonic acids, which are important environmental signatures of nerve agents. The method involved tert-butyldimethylchlorosilane mediated in situ silylation of analytes on commercially available diatomaceous solid phase extraction cartridges. Various parameters such as derivatizing reagent, its concentration, reaction time, temperature and eluting solvent were optimized. Recoveries of the analytes were determined by GC-MS which ranged from 60% to 86%. The limits of detection (LOD) and limit of quantification (LOQ) with selected analytes were achieved down to 78 and 213ngmL(-1) respectively, in selected ion monitoring mode. The successful applicability of method was also demonstrated on samples of biological origin such as plasma and to the samples received in 34th official proficiency test conducted by the Organization for Prohibition the of Chemical Weapons.


Asunto(s)
Sustancias para la Guerra Química/análisis , Sustancias para la Guerra Química/aislamiento & purificación , Cromatografía de Gases y Espectrometría de Masas/métodos , Extracción en Fase Sólida/métodos , Contaminantes Químicos del Agua/análisis , Contaminantes Químicos del Agua/aislamiento & purificación , Animales , Límite de Detección , Ratones , Plasma/química
13.
J Chromatogr A ; 1329: 10-6, 2014 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-24418235

RESUMEN

Analysis and identification of nitrogen containing aminoalcohols is an integral part of the verification analysis of chemical weapons convention (CWC). This study was aimed to develop extraction and derivatization of aminoalcohols of CWC relevance by using magnetic dispersive solid-phase extraction (MDSPE) in combination with on-resin derivatization (ORD). For this purpose, sulfonated magnetic cation-exchange resins (SMRs) were prepared using magnetite nanoparticles as core, styrene and divinylbenzene as polymer coat and sulfonic acid as acidic cation exchanger. SMRs were successfully employed as extractant for targeted basic analytes. Adsorbed analytes were derivatized with hexamethyldisilazane (HMDS) on the surface of extractant. Derivatized (silylated) compounds were analyzed by GC-MS in SIM and full scan mode. The linearity of the method ranged from 5 to 200ngmL(-1). The LOD and LOQ ranged from 2 to 6ngmL(-1) and 5 to 19ngmL(-1) respectively. The relative standard deviation for intra-day repeatability and inter-day intermediate precision ranged from 5.1% to 6.6% and 0.2% to 7.6% respectively. Recoveries of analytes from spiked water samples from different sources varied from 28.4% to 89.3%.


Asunto(s)
Amino Alcoholes/aislamiento & purificación , Adsorción , Resinas de Intercambio de Catión/química , Cationes/química , Cromatografía de Gases y Espectrometría de Masas/métodos , Magnetismo , Microscopía Electrónica de Rastreo , Extracción en Fase Sólida/métodos , Espectroscopía Infrarroja por Transformada de Fourier
14.
Analyst ; 137(23): 5648-53, 2012 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-23086107

RESUMEN

Conventional methods of detection of chemical warfare agents (CWAs) based on chromogenic reactions are time and solvent intensive. The development of cost, time and solvent effective microfluidic paper based analytical devices (µ-PADs) for the detection of nerve and vesicant agents is described. The detection of analytes was based upon their reactions with rhodamine hydroxamate and para-nitrobenzyl pyridine, producing red and blue colours respectively. Reactions were optimized on the µ-PADs to produce the limits of detection (LODs) as low as 100 µM for sulfur mustard in aqueous samples. Results were quantified with the help of a simple desktop scanner and Photoshop software. Sarin achieved a linear response in the two concentration ranges of 20-100 mM and 100-500 mM, whereas the response of sulfur mustard was found to be linear in the concentration range of 10-75 mM. Results were precise enough to establish the µ-PADs as a valuable tool for security personnel fighting against chemical terrorism.


Asunto(s)
Sustancias para la Guerra Química/análisis , Técnicas Analíticas Microfluídicas/instrumentación , Rodaminas/química , Compuestos Cromogénicos , Límite de Detección , Gas Mostaza/análisis , Papel , Piridinas/química , Sarín/análisis
15.
Anal Chim Acta ; 751: 71-8, 2012 Nov 02.
Artículo en Inglés | MEDLINE | ID: mdl-23084054

RESUMEN

A coupling of novel liquid-liquid-solid microextraction (LLSME) technique based on porous hydrophobic membrane and Fourier-transform infrared spectroscopy has been presented for the detection, identification and quantification of markers and simulants of nerve agents. Two isomers O,O'-dihexyl methylphosphonate (DHMP) and O,O'-dipentyl isopropylphosphonate (DPIPP) were chosen as model analytes for the study. In the present technique, organic phase was immobilised within the pores of membrane after fixing it in an assembly, which was then immersed into aqueous sample of target analytes for extraction. The analytes were directly determined on the surface of membrane by FTIR spectroscopy without elution. On comparison with solid phase microextraction (SPME), LLSME was found to be much more efficient. The method was optimised and quantitative analyses were performed using calibration curves obtained via Beer's law and employing processing of spectra obtained, via a multivariate calibration technique partial least square (PLS). Relative standard deviations (RSDs) for intraday repeatability and interday reproducibility were found to be in the range of 0.20-0.50% and 0.20-0.60%, respectively. Limit of detection (LOD) was achieved up to 15 ng mL(-1). Applicability of the method was tested with an unknown real sample obtained in an international official proficiency test (OPT).


Asunto(s)
Sustancias para la Guerra Química/análisis , Microextracción en Fase Líquida/instrumentación , Compuestos Organofosforados/análisis , Espectroscopía Infrarroja por Transformada de Fourier/instrumentación , Agua/análisis , Sustancias para la Guerra Química/aislamiento & purificación , Diseño de Equipo , Límite de Detección , Membranas Artificiales , Compuestos Organofosforados/aislamiento & purificación , Reproducibilidad de los Resultados
16.
Rapid Commun Mass Spectrom ; 26(22): 2637-48, 2012 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-23059880

RESUMEN

A new analytical method based on liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) is proposed and validated for the identification and quantification of alkyl alkylphosphonic acids (AAPAs) in aqueous matrices. Retrospective detection and identification of degradation products of chemical warfare agents is important as an indicator of possible use of chemical warfare agents or of environmental contamination. A commercially available solution of 1,9-nonanediyl-bis-(3-methylimidazolium)bisfluoride (NBMI) allowed detection of AAPAs by positive mode electrospray ionization mass spectrometry by forming an adduct with AAPAs. MS/MS experiments using an ion trap analyzer were carried out for unambiguous identification of AAPAs. Different parameters were optimized in order to obtain both an adequate chromatographic separation and a high sensitivity using experimental design methodology. Quantification was done with matrix-matched calibration standards of AAPAs. The method was validated in terms of linearity (r(2) >0.982), intra- and inter-day precisions (RSD below 15%), and robustness. The method is sensitive enough for the determination of AAPAs in aqueous matrices, with limits of detection in the 1-5 ng mL(-1) range and limits of quantification in the 5-20 ng mL(-1) range. Finally, the method was successfully applied to determine these AAPAs in aqueous samples provided by the Organization for the Prohibition of Chemical Weapons during 26(th) and 29(th) official proficiency tests. The added advantage of this method is identification of low mass range analyte at high mass range, which obviates the background noise at low mass range.

17.
J Chromatogr A ; 1218(52): 9307-13, 2011 Dec 30.
Artículo en Inglés | MEDLINE | ID: mdl-22119612

RESUMEN

Extraction, enrichment and gas chromatography mass spectrometric analysis of degradation products of nerve agents from water is of significant importance for verification of Chemical Weapons Convention (CWC) and gathering forensic evidence of use of nerve agents. Multi-walled carbon nanotubes (MWCNTs) were non-covalently functionalized with poly(diallyldimethylammonium chloride) (PDDA) to afford the cationic functionalized nano-tubes, which were used as solid-phase anionic-exchanger sorbents to extract the acidic degradation products of nerve agents from water. Extraction efficiencies of MWCNTs-PDDA were compared with those of mixed mode anion-exchange (HLB) and silica based strong anion-exchange (Si-SAX) cartridges. Optimized extraction parameters included MWCNTs-PDDA 12 mg, washing solvent 5 mL water and eluting solvent 3 mL of 0.1M aqueous HCl followed by 3 mL methanol. At 1 ng mL(-1) spiking concentration of mono- and di-basic phosphonic acids, MWCNTs-PDDA exhibited higher extraction efficiencies in comparison to Si-SAX and HLB. The limits of detection were achieved down to 0.05 and 0.11 ng mL(-1) in selected ion and full scan monitoring mode respectively; and limits of quantification in selected ion monitoring mode were achieved down to 0.21 ng mL(-1).


Asunto(s)
Sustancias para la Guerra Química/química , Electrólitos/química , Nanotubos de Carbono/química , Organofosfonatos/química , Extracción en Fase Sólida/métodos , Adsorción , Aminopiridinas/química , Sustancias para la Guerra Química/aislamiento & purificación , Cromatografía por Intercambio Iónico , Cromatografía de Gases y Espectrometría de Masas , Iones/química , Límite de Detección , Organofosfonatos/aislamiento & purificación , Polietilenos/química , Compuestos de Amonio Cuaternario/química , Sulfonamidas/química , Agua
18.
Rapid Commun Mass Spectrom ; 25(22): 3411-6, 2011 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-22002694

RESUMEN

The retrospective detection and identification of degradation products of chemical warfare agents are of immense importance in order to prove their spillage and use. A highly sensitive liquid chromatography/electrospray ionization tandem mass spectrometric (LC/ESI-MS/MS) method--using an imidazolium-based tricationic reagent--was developed for the detection and identification of the anionic degradation products of nerve agents. A commercially available solution of 1,3-imidazolium-bis-(1-hexylbenzylimidazolium) trifluoride (IBHBI) formed adducts with alkylphosphonic acids (APAs), allowing detection of the APAs by positive mode ESI-MS. Tandem mass spectrometry was used for the unambiguous identification of the APAs. Parameters influencing the formation and stability of these adduct during mass spectrometric analysis, such as solvent composition, concentration of IBHBI, effect of pH and interferences by salts, were optimized. The absolute limits of detection (0.1 ng) for achieved for the APAs were better than those previously reported, and linear dynamic ranges of 10-2000 ng mL(-1) were achieved. The method was repeatable with a relative standard deviation ≤7.3%. APAs present in aqueous samples provided by the Organization for the Prohibition of Chemical Weapons during the 22(nd) and 24(th) Official Proficiency tests were detected and identified as IBHBI adducts. The added advantage of this method is that low-mass analytes are detected at higher mass, thus obviating the problem with background noise at low mass.


Asunto(s)
Sustancias para la Guerra Química/análisis , Imidazoles/química , Compuestos Organofosforados/análisis , Espectrometría de Masa por Ionización de Electrospray/métodos , Espectrometría de Masas en Tándem/métodos , Sustancias para la Guerra Química/química , Fluoruros/química , Concentración de Iones de Hidrógeno , Organofosfonatos/análisis , Organofosfonatos/química , Compuestos Organofosforados/química , Compuestos de Amonio Cuaternario , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
19.
J Chromatogr A ; 1218(38): 6612-20, 2011 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-21862029

RESUMEN

Selective extraction and enrichment of nerve agent degradation products has been achieved using zirconia based commercial solid-phase extraction cartridges. Target analytes were O-alkyl alkylphosphonic acids and alkylphosphonic acids, the environmental markers of nerve agents such as sarin, soman and VX. Critical extraction parameters such as modifier concentration, nature and volume of washing and eluting solvents were investigated. Amongst other anionic compounds, selectivity in extraction was observed for organophosphorus compounds. Recoveries of analytes were determined by GC-MS which ranged from 80% to 115%. Comparison of zirconia based solid-phase extraction method with anion-exchange solid-phase extraction revealed its selectivity towards phosphonic acids. The limits of detection (LOD) and limit of quantification (LOQ) with selected analytes were achieved down to 4.3 and 8.5 ng mL(-1), respectively, in selected ion monitoring mode.


Asunto(s)
Sustancias para la Guerra Química/aislamiento & purificación , Neurotransmisores/aislamiento & purificación , Compuestos Organofosforados/aislamiento & purificación , Extracción en Fase Sólida/métodos , Circonio/química , Adsorción , Sustancias para la Guerra Química/química , Neurotransmisores/química , Compuestos Organofosforados/química , Sarín/química , Sarín/aislamiento & purificación , Sensibilidad y Especificidad , Extracción en Fase Sólida/instrumentación , Soman/química , Soman/aislamiento & purificación
20.
Artículo en Inglés | MEDLINE | ID: mdl-21625030

RESUMEN

Gas chromatography-mass spectrometry (GC-MS) analysis of O,O'-dialkyl methylphosphonites (DAMPs) was carried out with a view to developing a database and understanding the mechanism of fragmentation. DAMPs are included in the list of schedule 2B4 chemicals of the Chemical Weapons Convention. GC-MS analysis of DAMPs and their deuterated analogs revealed that their fragmentations were dominated by α-cleavages, alkenyl radical loss and hydrogen rearrangements. Based on fragment ions of deuterated analogs and density functional theory calculations, the fragmentation routes were rationalized.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...