Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38817687

RESUMEN

Objective: A newly launched endoscopy system (EVIS X1, CV-1500; Olympus) is equipped with texture and color enhancement imaging (TXI). We aimed to investigate the efficacy of TXI for the visibility and diagnostic accuracy of non-polypoid colorectal lesions. Methods: We examined 100 non-polypoid lesions in 42 patients from the same position, angle, and distance of the view in three modes: white light imaging (WLI), narrow-band imaging (NBI), and TXI. The primary outcome was to compare polyp visibility in the three modes using subjective polyp visibility score and objective color difference values. The secondary outcome was to compare the diagnostic accuracy without magnification. Results: Overall, the visibility score of TXI was significantly higher than that of WLI (3.7 ± 1.1 vs. 3.6 ± 1.1; p = 0.008) and lower than that of NBI (3.7 ± 1.1 vs. 3.8 ± 1.1; p = 0.013). Color difference values of TXI were higher than those of WLI (11.5 ± 6.9 vs. 9.1 ± 5.4; p < 0.001) and lower than those of NBI (11.5 ± 6.9 vs. 13.1 ± 7.7; p = 0.002). No significant differences in TXI and NBI (visibility score: 3.7 ± 1.0 vs. 3.8 ± 1.1; p = 0.833, color difference values: 11.6 ± 7.1 vs. 12.9 ± 8.3; p = 0.099) were observed for neoplastic lesions. Moreover, the diagnostic accuracy of TXI was significantly higher than that of NBI (65.5% vs. 57.6%, p = 0.012) for neoplastic lesions. Conclusions: TXI demonstrated higher visibility than that of WLI and lower than that of NBI. Further investigations are warranted to validate the performance of the TXI mode comprehensively.

2.
Artículo en Inglés | MEDLINE | ID: mdl-38740465

RESUMEN

BACKGROUND AND AIM: Hot snare excision using electrocautery is widely used for large colorectal polyps (>10 mm); however, adverse events occur due to deep thermal injury. Colorectal polyps measuring 10-14 mm rarely include invasive cancer. Therefore, less invasive therapeutic options for this size category are demanding. We have developed hot snare polypectomy with low-power pure-cut current (LPPC HSP), which is expected to contribute to less deep thermal damage and lower risk of adverse events. This study aimed to evaluate the efficacy and safety of LPPC HSP for 10-14 mm colorectal polyps, compared with conventional endoscopic mucosal resection (EMR). METHODS: In this multicenter, retrospective, observational study, clinical outcomes of EMR and LPPC HSP for 10-14 mm nonpedunculated colorectal polyps between January 2021 and March 2022 were compared using propensity score matching. RESULTS: We identified 203 EMR and 208 LPPC HSP cases. After propensity score matching, the baseline characteristics between the groups were comparable, with 120 pairs. The en bloc and R0 resection rates were not significantly different between EMR and LPPC HSP groups (95.8% vs 97.5%, P = 0.72; 90.0% vs 91.7%, P = 0.82). The rates of delayed bleeding and perforation did not differ between the groups. CONCLUSIONS: Compared with conventional EMR, LPPC HSP showed a similar resection ability without an increase in adverse events. These results suggest that LPPC HSP is a safe and effective treatment for 10-14 mm nonpedunculated colorectal polyps.

3.
Dig Endosc ; 2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38775419

RESUMEN

OBJECTIVES: Endoscopic hand suturing (EHS) is a novel technique for closing a mucosal defect after endoscopic submucosal dissection (ESD). We investigated the technical feasibility of colorectal EHS using a modified flexible through-the-scope needle holder. METHODS: This was a prospective multicenter study conducted at two referral centers between June 2022 and April 2023. This study included colorectal neoplasms 20-50 mm in size located in the sigmoid colon or rectum. A modified flexible through-the-scope needle holder, with an increased jaw width to facilitate needle grasping, was used for colorectal EHS. The primary end-points were sustained closure rate on second-look endoscopy (SLE) performed on postoperative days 3-4 and suturing time for colorectal EHS. Secondary end-points included complete closure rate and delayed adverse events. RESULTS: We enrolled 20 colorectal neoplasms in 20 patients, including four patients receiving antithrombotic agents. The tumor location was as follows: lower rectum (n = 8), upper rectum (n = 2), rectosigmoid colon (n = 4), and sigmoid colon (n = 6), and the median mucosal defect size was 37 mm (range, 21-65 mm). The complete closure rate was 90% (18/20 [95% confidence interval (CI) 68.3-98.8%]), and the median suturing time was 49 min (range, 23-92 min [95% CI 35-68 min]). Sustained closure rate on SLE was 85% (17/20 [95% CI 62.1-96.8%]). No delayed adverse events were observed. CONCLUSION: EHS demonstrated a high sustained closure rate. Given the long suturing time and technical difficulty, EHS should be reserved for cases with a high risk of delayed adverse events.

5.
Artículo en Inglés | MEDLINE | ID: mdl-38646886

RESUMEN

BACKGROUND AND AIM: Tip-in endoscopic mucosal resection (EMR) has a high en bloc resection rate for large colorectal neoplasms. However, non-experts' performance in Tip-in EMR has not been investigated. We investigated whether Tip-in EMR can be achieved effectively and safely even by non-experts. METHODS: This retrospective study included consecutive patients who underwent Tip-in EMR for 15-25 mm colorectal nonpedunculated neoplasms at a Japanese tertiary cancer center between January 2014 and December 2020. Baseline characteristics, treatment outcomes, learning curve of non-experts, and risk factors of failing self-achieved en bloc resection were analyzed. RESULTS: A total of 597 lesions were analyzed (438 by experts and 159 by non-experts). The self-achieved en bloc resection (69.8% vs 88.6%, P < 0.001) and self-achieved R0 resection (58.3% vs 76.5%, P < 0.001) rates were significantly lower in non-experts with <10 cases of experience than in experts, but not in non-experts with >10 cases. Adverse event (P = 0.165) and local recurrence (P = 0.892) rates were not significantly different between experts and non-experts. Risk factors of failing self-achieved en bloc resection were non-polypoid morphology (OR 3.4, 95% CI 1.6-7.3, P = 0.001), lesions with an underlying semilunar fold (OR 3.6, 95% CI 1.6-7.3, P < 0.001), positive non-lifting sign (OR 3.1, 95% CI 1.2-8.0, P = 0.023), and non-experts with an experience of ≤10 cases (OR 3.6, 95% CI 2.1-6.3, P < 0.001). CONCLUSION: The clinical outcomes of Tip-in EMR for 15-25 mm lesions performed by non-experts were favorable.

6.
Dig Endosc ; 2024 Mar 03.
Artículo en Inglés | MEDLINE | ID: mdl-38433322

RESUMEN

OBJECTIVES: There are several types of colorectal cancer (CRC) according to the detection methods and intervals, including interval CRC (iCRC) and postcolonoscopy CRC (PCCRC). We aimed to examine their proportions and characteristics. METHODS: We conducted a multicenter prospective study using questionnaires in Japan ("C-DETECT study"), in which differences in CRC characteristics according to detection methods and intervals were examined from consecutive adult patients. Because the annual fecal immunochemical test (FIT) was used in population-based screening, the annual FIT-iCRC was assessed. RESULTS: In total, 1241 CRC patients (1064 with invasive CRC) were included. Annual FIT-iCRC (a), 3-year PCCRC (b), and CRC detected within 1 year after a positive FIT with noncompliance to colonoscopy (c) accounted for 4.5%, 7.0%, and 3.9% of all CRCs, respectively, and for 3.9%, 5.4%, and 4.3% of invasive CRCs, respectively. The comparison among these (a, b, c) and other CRCs (d) demonstrated differences in the proportions of ≥T2 invasion ([a] 58.9%, [b] 44.8%, [c] 87.5%, [d] 73.0%), metastasis ([a] 33.9%, [b] 21.8%, [c] 54.2%, [d] 43.9%), right-sided CRC ([a] 42.9%, [b] 40.2%, [c] 18.8%, [d] 28.6%), and female sex ([a] 53.6%, [b] 49.4%, [c] 27.1%, [d] 41.6%). In metastatic CRC, (a) and (b) showed a higher proportions of BRAF mutations ([a] [b] 12.0%, [c] [d] 3.1%). CONCLUSIONS: Annual FIT-iCRC and 3-year PCCRC existed in nonnegligible proportions. They were characterized by higher proportions of right-sided tumors, female sex, and BRAF mutations. These findings suggest that annual FIT-iCRC and 3-year PCCRC may have biological features different from those of other CRCs.

7.
BMC Gastroenterol ; 24(1): 61, 2024 Feb 03.
Artículo en Inglés | MEDLINE | ID: mdl-38310266

RESUMEN

BACKGROUND: Sodium picosulfate (SP)/magnesium citrate (MC) and polyethylene glycol (PEG) plus ascorbic acid are recommended by Western guidelines as laxative solutions for bowel preparation. Clinically, SP/MC has a slower post-dose defaecation response than PEG and is perceived as less cleansing; therefore, it is not currently used for major bowel cancer screening preparation. The standard formulation for bowel preparation is PEG; however, a large dose is required, and it has a distinctive flavour that is considered unpleasant. SP/MC requires a small dose and ensures fluid intake because it is administered in another beverage. Therefore, clinical trials have shown that SP/MC is superior to PEG in terms of acceptability. We aim to compare the novel bowel cleansing method (test group) comprising SP/MC with elobixibat hydrate and the standard bowel cleansing method comprising PEG plus ascorbic acid (standard group) for patients preparing for outpatient colonoscopy. METHODS: This phase III, multicentre, single-blind, noninferiority, randomised, controlled, trial has not yet been completed. Patients aged 40-69 years will be included as participants. Patients with a history of abdominal or pelvic surgery, constipation, inflammatory bowel disease, or severe organ dysfunction will be excluded. The target number of research participants is 540 (standard group, 270 cases; test group, 270 cases). The primary endpoint is the degree of bowel cleansing (Boston Bowel Preparation Scale [BBPS] score ≥ 6). The secondary endpoints are patient acceptability, adverse events, polyp/adenoma detection rate, number of polyps/adenomas detected, degree of bowel cleansing according to the BBPS (BBPS score ≥ 8), degree of bowel cleansing according to the Aronchik scale, and bowel cleansing time. DISCUSSION: This trial aims to develop a "patient-first" colon cleansing regimen without the risk of inadequate bowel preparation by using both elobixibat hydrate and SP/MC. TRIAL REGISTRATION: Japan Registry of Clinical Trials (jRCT; no. s041210067; 9 September 2021; https://jrct.niph.go.jp/ ), protocol version 1.5 (May 1, 2023).


Asunto(s)
Citratos , Ácido Cítrico , Dipéptidos , Compuestos Organometálicos , Picolinas , Polietilenglicoles , Pólipos , Tiazepinas , Humanos , Catárticos , Pacientes Ambulatorios , Ácido Ascórbico/efectos adversos , Método Simple Ciego , Colonoscopía/métodos , Ensayos Clínicos Controlados Aleatorios como Asunto , Estudios Multicéntricos como Asunto , Ensayos Clínicos Fase III como Asunto
8.
BMC Gastroenterol ; 24(1): 69, 2024 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-38331727

RESUMEN

BACKGROUND: Endoscopic resection is widely accepted as a local treatment for rectal neuroendocrine tumors sized ≤ 10 mm. However, there is no consensus on the best method for the endoscopic resection of rectal neuroendocrine tumors. As a simplified endoscopic procedure, endoscopic submucosal resection with a ligation device (ESMR-L) indicates a histologically complete resection rate comparable to that of endoscopic submucosal dissection (ESD). We hypothesized that ESMR-L than ESD would be preferred for rectal neuroendocrine tumors. Hence, this trial aimed to verify whether ESMR-L is non-inferior to ESD in terms of histologically complete resection rate. METHODS: This is a prospective, open-label, multicenter, non-inferiority, randomized controlled trial of two parallel groups, conducted at the Shizuoka Cancer Center and 31 other institutions in Japan. Patients with a lesion endoscopically diagnosed as a rectal neuroendocrine tumor ≤ 10 mm are eligible for inclusion. A total of 266 patients will be recruited and randomized to undergo either ESD or ESMR-L. The primary endpoint is the rate of en bloc resection with histologically tumor-free margins (R0 resection). Secondary endpoints include en bloc resection rate, procedure time, adverse events, hospitalization days, total devices and agents cost, adverse event rate between groups with and without resection site closure, outcomes between expert and non-expert endoscopists, and factors associated with R0 resection failure. The sample size is determined based on the assumption that the R0 resection rate will be 95.2% in the ESD group and 95.3% in the ESMR-L group, with a non-inferiority margin of 8%. With a one-sided significance level of 0.05 and a power of 80%, 226 participants are required. Assuming a dropout rate of 15%, 266 patients will be included in this study. DISCUSSION: This is the first multicenter randomized controlled trial comparing ESD and ESMR-L for the R0 resection of rectal neuroendocrine tumors ≤ 10 mm. This will provide valuable information for standardizing endoscopic resection methods for rectal neuroendocrine tumors. TRIAL REGISTRATION: Japan Registry of Clinical Trials, jRCTs042210124. Registered on Jan 6, 2022.


Asunto(s)
Resección Endoscópica de la Mucosa , Tumores Neuroendocrinos , Neoplasias del Recto , Humanos , Tumores Neuroendocrinos/cirugía , Tumores Neuroendocrinos/patología , Estudios Prospectivos , Estudios Retrospectivos , Ligadura , Neoplasias del Recto/cirugía , Neoplasias del Recto/patología , Resección Endoscópica de la Mucosa/métodos , Resultado del Tratamiento , Ensayos Clínicos Controlados Aleatorios como Asunto , Estudios Multicéntricos como Asunto
9.
J Gastroenterol Hepatol ; 39(5): 927-934, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38273460

RESUMEN

BACKGROUND AND AIM: Computer-aided detection (CADe) systems can efficiently detect polyps during colonoscopy. However, false-positive (FP) activation is a major limitation of CADe. We aimed to compare the rate and causes of FP using CADe before and after an update designed to reduce FP. METHODS: We analyzed CADe-assisted colonoscopy videos recorded between July 2022 and October 2022. The number and causes of FPs and excessive time spent by the endoscopist on FP (ET) were compared pre- and post-update using 1:1 propensity score matching. RESULTS: During the study period, 191 colonoscopy videos (94 and 97 in the pre- and post-update groups, respectively) were recorded. Propensity score matching resulted in 146 videos (73 in each group). The mean number of FPs and median ET per colonoscopy were significantly lower in the post-update group than those in the pre-update group (4.2 ± 3.7 vs 18.1 ± 11.1; P < 0.001 and 0 vs 16 s; P < 0.001, respectively). Mucosal tags, bubbles, and folds had the strongest association with decreased FP post-update (pre-update vs post-update: 4.3 ± 3.6 vs 0.4 ± 0.8, 0.32 ± 0.70 vs 0.04 ± 0.20, and 8.6 ± 6.7 vs 1.6 ± 1.7, respectively). There was no significant decrease in the true positive rate (post-update vs pre-update: 95.0% vs 99.2%; P = 0.09) or the adenoma detection rate (post-update vs pre-update: 52.1% vs 49.3%; P = 0.87). CONCLUSIONS: The updated CADe can reduce FP without impairing polyp detection. A reduction in FP may help relieve the burden on endoscopists.


Asunto(s)
Pólipos del Colon , Colonoscopía , Diagnóstico por Computador , Humanos , Colonoscopía/métodos , Diagnóstico por Computador/métodos , Reacciones Falso Positivas , Masculino , Femenino , Persona de Mediana Edad , Pólipos del Colon/diagnóstico , Pólipos del Colon/diagnóstico por imagen , Anciano , Grabación en Video , Puntaje de Propensión , Factores de Tiempo
10.
Clin Gastroenterol Hepatol ; 22(2): 271-282.e3, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-37743040

RESUMEN

BACKGROUND & AIMS: Reported rates of delayed bleeding (DB) after endoscopic resection using direct oral anticoagulants (DOACs) are high and heterogeneous. This large-scale multicenter study analyzed cases of DB after colorectal endoscopic submucosal dissection related to various types of DOACs in Japan (the ABCD-J study) with those associated with warfarin. METHODS: We retrospectively reviewed 1019 lesions in patients treated with DOACs and 459 lesions in patients treated with warfarin among 34,455 endoscopic submucosal dissection cases from 47 Japanese institutions between 2012 and 2021. The DB rate (DBR) with each DOAC was compared with that with warfarin. Risk factors for DB in patients treated with DOACs or warfarin were also investigated. RESULTS: The mean tumor sizes in the DOAC and warfarin groups were 29.6 ± 14.0 and 30.3 ± 16.4 mm, respectively. In the DOAC group, the DBR with dabigatran (18.26%) was significantly higher than that with apixaban (10.08%, P = .029), edoxaban (7.73%, P = .001), and rivaroxaban (7.21%, P < .001). Only rivaroxaban showed a significantly lower DBR than warfarin (11.76%, P = .033). In the multivariate analysis, heparin bridging therapy (odds ratio [OR], 2.18; 95% confidence interval [CI], 1.27-3.73, P = .005), rectal location (2.01, 1.28-3.16, P = .002), and procedure time ≥55 minutes (2.43, 1.49-3.95, P < .001) were significant risk factors for DB in the DOAC group. The DB risk in the DOAC group (OR, (95% CI)) was 2.13 (1.30-3.50) and 4.53 (2.52-8.15) for 1 and 2 significant risk factors, respectively. CONCLUSIONS: Dabigatran was associated with a higher DBR than other DOACs, and only rivaroxaban was associated with a significantly lower DBR than warfarin.


Asunto(s)
Fibrilación Atrial , Neoplasias Colorrectales , Resección Endoscópica de la Mucosa , Humanos , Warfarina , Rivaroxabán/efectos adversos , Dabigatrán/efectos adversos , Japón , Resección Endoscópica de la Mucosa/efectos adversos , Estudios Retrospectivos , Hemorragia/inducido químicamente , Anticoagulantes , Neoplasias Colorrectales/cirugía , Neoplasias Colorrectales/complicaciones , Administración Oral , Fibrilación Atrial/complicaciones
14.
Ann Surg Oncol ; 31(2): 762-771, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37925659

RESUMEN

BACKGROUND: Colorectal cancer (CRC) is the most common cancer that coincides with gastric cancer (GC). Although the usefulness of total colonoscopy (TCS) as a CRC screening tool has been reported in preoperative patients with GC, the long-term outcome of patients with synchronous CRC (SCRC) remains unclear. This study aims to clarify the significance of preoperative screening TCS for GC in terms of survival outcomes. PATIENTS AND METHODS: We included 796 patients who underwent preoperative screening TCS for GC. The risk factors, clinicopathological features, and survival outcome of SCRC were examined. Furthermore, the cost-effectiveness was evaluated from the perspective of improving the rates of mortality caused by CRC. RESULTS: SCRC was observed in 43 patients (5.4%). Endoscopic treatment for SCRC was performed on 30 patients. In total, 15 patients underwent surgical resection, including 2 patients requiring additional surgery after endoscopic treatment. Regarding pathological stages, 25 patients had stage 0, 12 patients had stage I, 5 patients had stage II, and 1 patient had stage IIIB disease. The cumulative mortality rates were as follows: GC-related deaths, 12.6%; deaths from cancers other than CRC, 1%; deaths from other causes, 5.5%. No deaths were attributed to SCRC. Comparing the patients who did not undergo TCS, an incremental cost-effectiveness ratio analysis suggested that a screening cost of 5.86 million yen was required to prevent one CRC death. CONCLUSIONS: Curative treatment was possible in all patients with SCRC. No deaths were attributed to SCRC, suggesting that screening TCS for GC is effective.


Asunto(s)
Neoplasias Colorrectales , Neoplasias Gástricas , Humanos , Neoplasias Gástricas/diagnóstico , Neoplasias Gástricas/cirugía , Neoplasias Gástricas/patología , Estudios Retrospectivos , Detección Precoz del Cáncer , Colonoscopía , Factores de Riesgo , Neoplasias Colorrectales/diagnóstico , Neoplasias Colorrectales/cirugía , Neoplasias Colorrectales/patología , Análisis Costo-Beneficio , Tamizaje Masivo
15.
J Gastroenterol Hepatol ; 39(4): 667-673, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38149747

RESUMEN

BACKGROUND AND AIM: Hot snare polypectomy using blend or coagulation current is widely used; however, it causes deeper tissue heat injury, leading to adverse events. We hypothesized that hot polypectomy using low-power pure cut current (PureCut, effect 1 10 W) could reduce deeper tissue heat injury. We conducted animal experiments to evaluate the deeper tissue heat injury and conducted a prospective clinical study to examine its cutting ability. METHODS: In a porcine rectum, hot polypectomy using Blend current (EndoCut, effect 3 40 W) and low-power pure cut current was performed. The deepest part of heat destruction and thickness of the non-burned submucosal layer were evaluated histologically. Based on the results, we performed low-power pure cut current hot polypectomy for 10-14 mm adenoma. The primary endpoint was complete resection defined as one-piece resection with negative for adenoma in quadrant biopsies from the defect margin. RESULTS: In experiments, all low-power pure-cut resections were limited within the submucosal layer whereas blend current resections coagulated the muscular layer in 13% (3/23). The remaining submucosal layer was thicker in low-power pure cut current than in blend current resections. In the clinical study, low-power pure-cut hot polypectomy removed all 100 enrolled polyps. For 98 pathologically neoplastic polyps, complete resection was achieved in 84 (85.7%, 95% confidence interval, 77-92%). The lower limit of the 95% confidence interval was not more than 15% below the pre-defined threshold of 86.6%. No severe adverse events occurred. CONCLUSIONS: A novel low-power pure-cut hot polypectomy may be feasible for adenoma measuring 10-14 mm. (UMIN000037678).


Asunto(s)
Adenoma , Pólipos del Colon , Neoplasias Colorrectales , Humanos , Pólipos del Colon/cirugía , Pólipos del Colon/patología , Colonoscopía/métodos , Estudios Prospectivos , Estudios de Factibilidad , Neoplasias Colorrectales/cirugía , Neoplasias Colorrectales/patología , Adenoma/cirugía , Adenoma/patología
17.
J Anus Rectum Colon ; 7(4): 241-249, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37900694

RESUMEN

Early-onset colorectal cancer (CRC), which refers to CRC diagnosed in individuals below the age of 50 years, is a growing health concern that presents unique challenges in diagnosis, treatment, and long-term outcomes. Although approximately 70% of early-onset CRC cases are sporadic, with no apparent family history, approximately 25% have a familial component, and up to 20% may be associated with germline mutations, indicating a higher prevalence compared with the general population. Despite the progress in identifying the environmental, molecular, and genetic risk factors of early-onset CRC, the underlying causes for the global increase in its incidence remain unclear. This comprehensive review aims to provide a thorough analysis of early-onset CRC by examining the trends associated with its incidence, clinical and pathological characteristics, risk factors, molecular and genetic profiles, prognosis and screening strategies. By deepening our understanding of early-onset CRC, significant advances related to improving the outcomes and alleviating the burden of this disease on individuals, families, and healthcare systems can be achieved.

19.
Hum Pathol ; 141: 149-157, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37633534

RESUMEN

Tumor depth evaluation is essential for pathological tumor staging because it affects clinical management as an independent risk factor for lymph node metastasis in colorectal cancers. However, poor interobserver variability of invasion depth has been reported. This study aimed to clarify the effectiveness of desmin immunostaining in the histological diagnosis of colorectal cancer. Overall, 63 sets of slides of colorectal cancer stained with hematoxylin and eosin (H&E) and desmin were prepared and independently reviewed by four examiners. After reviewing the desmin-stained slides, the interobserver variability of H&E slides alone was significantly improved for all examiners. For the assessment of Tis vs. T1, the sensitivity and accuracy were significantly improved for all examiners by combining H&E and desmin immunostaining. For the diagnosis of T1b vs. Tis or T1a, specificity and accuracy were significantly improved by adding desmin immunostaining. Ancillary desmin staining to assess submucosal invasion in colorectal cancers significantly improved interobserver agreement, led to efficient screening of T1 cancers, and reduced excessive T1b diagnoses. The combination of desmin immunostaining and H&E staining is highly recommended for diagnosing invasive colorectal cancer.


Asunto(s)
Neoplasias Colorrectales , Desmina , Coloración y Etiquetado , Neoplasias Colorrectales/diagnóstico , Neoplasias Colorrectales/patología , Coloración y Etiquetado/métodos , Humanos , Variaciones Dependientes del Observador
20.
J Gastroenterol Hepatol ; 38(10): 1802-1807, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37519057

RESUMEN

BACKGROUND AND AIM: It is unclear whether additional treatment should be considered given the recurrence risk after endoscopic submucosal dissection (ESD) for esophageal squamous cell carcinoma (ESCC) when the vertical margin is positive or unclear (VM1/VMX) due to intralesional damage. This study aimed to elucidate the local recurrence risk of ESCC caused by intralesional damage during ESD. METHODS: Among consecutive patients with pT1a ESCCs initially treated by ESD at our institution between January 2006 and December 2018, ESCCs diagnosed as VM1/VMX were retrospectively reviewed. Exclusion criteria were piecemeal resection and any additional treatment after ESD. Intralesional damage included the following three types: a macroscopic hole inside the lesion, an incision from the lateral margin of the specimen into the lesion, and crushing injury or burn effect into the deepest area of the lesion without an obvious hole. The local recurrence rate after ESD was primarily analyzed. RESULTS: Of 1174 pT1a ESCCs initially treated using ESD, 22 lesions were histopathologically diagnosed as VM1/VMX due to intralesional damage (1.9%; 95% confidence interval [CI], 1.2-2.8%). At a median follow-up period of 60.0 (interquartile range, 15.0-84.0) months, no local recurrence was observed (0.0%; 95% CI, 0.0-13.3%) among 21 lesions finally evaluated. CONCLUSIONS: The impact of intralesional damage during ESD for ESCC on local recurrence might be negligible. Follow-up without additional treatment may be acceptable even if intralesional damage occurs and results in VM1/VMX after ESD for pT1a ESCCs.


Asunto(s)
Resección Endoscópica de la Mucosa , Neoplasias Esofágicas , Carcinoma de Células Escamosas de Esófago , Humanos , Carcinoma de Células Escamosas de Esófago/cirugía , Carcinoma de Células Escamosas de Esófago/etiología , Neoplasias Esofágicas/patología , Resección Endoscópica de la Mucosa/efectos adversos , Resección Endoscópica de la Mucosa/métodos , Estudios Retrospectivos , Recurrencia Local de Neoplasia/patología , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...