Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 14(1): 12773, 2024 06 04.
Artículo en Inglés | MEDLINE | ID: mdl-38834636

RESUMEN

The use of fibrin glue for inguinal hernia mesh fixation has been suggested to be effective in preventing hematomas and reducing postoperative pain compared to tacks and sutures.. The effect of fibrin glue can vary significantly based on the device used. This study assessed the efficacy of fibrin glue based on the type of devices used in an ex vivo system. The rabbit's abdominal wall was trimmed to a size of 3.0 × 6.0 cm and was secured at the edges with metal fixtures. To measure the maximum tensile strength at the point of adhesion failure, the hernia mesh was fixed to the rabbit's abdominal wall using fibrin glue in a 2 cm square area, left for 3 min, and then pulled at a speed of 50 cm/min. The test was conducted 10 times for each group. The median (minimum-maximum) tensile strength values using the spraying, two-liquid mixing, and sequential layering methods were 3.58 (1.99-4.95), 0.51 (0.27-1.89), and 1.32 (0.63-1.66) N, respectively. The spraying method had predominantly higher tensile strength values than the two-liquid mixing and sequential layering methods (P < 0.01). In conclusion, in hernia mesh fixation, the spraying method can be adopted to achieve appropriate adhesive effects.


Asunto(s)
Adhesivo de Tejido de Fibrina , Hernia Inguinal , Herniorrafia , Mallas Quirúrgicas , Resistencia a la Tracción , Hernia Inguinal/cirugía , Animales , Conejos , Herniorrafia/métodos , Herniorrafia/instrumentación , Adhesivos Tisulares/farmacología , Pared Abdominal/cirugía
2.
J Cardiothorac Surg ; 19(1): 149, 2024 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-38515189

RESUMEN

OBJECTIVE: Our previous study revealed that the viscosity of fibrinogen could influence the effectiveness of ventilation and anchoring (V/A) methods for controlling air leakages. Here, we examined the association between the viscosity of fibrinogen and effectiveness using an ex vivo pig model. METHODS: The fibrin glue used in this study was BOLHEAL® (KM Biologics Co., Ltd., Kumamoto, Japan). We prepared three types of fibrinogen with different viscosities (higher and lower than normal), including one without additives. Using an ex vivo pig model, a pleural defect was made, and the defect was repaired using three different viscosities of fibrinogen through the V/A method. We measured the rupture pressure at the repair site (N = 10) and histologically evaluated the depth of fibrin infiltration into the lung parenchyma at the repair sites. RESULTS: The median rupture pressure was 51.5 (40-73) cmH2O in Group 1 (lower viscosity), 47.0 (47-88) cmH2O in Group 2 (no change in viscosity), and 35.5 (25-61) cmH2O in Group 3 (higher viscosity). There was no statistically significant difference between Groups 1 and 2 (p = 0.819), but the rupture pressure was significantly higher in Group 2 than in Group 3 (p = 0.0136). Histological evaluation revealed deep infiltration of fibrin into the lung parenchyma in Groups 1 and 2, but no such infiltration was observed in the higher-viscosity group. CONCLUSIONS: The results of this experiment suggested that the V/A method using fibrin glue containing low-viscosity fibrinogen was more effective in controlling air leakage due to pleural defects.


Asunto(s)
Adhesivo de Tejido de Fibrina , Hemostáticos , Animales , Porcinos , Adhesivo de Tejido de Fibrina/farmacología , Adhesivo de Tejido de Fibrina/uso terapéutico , Viscosidad , Fibrinógeno/uso terapéutico , Pulmón/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA