Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Biomed Mater Res B Appl Biomater ; 110(7): 1615-1623, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35099112

RESUMEN

A combination product of human mesenchymal stem/stromal cells (MSCs) embedded in an extracellular matrix scaffold and preconditioned with hypoxia and the beta-adrenergic receptor antagonist, timolol, combined with sustained timolol application post implantation, has shown promising results for improving wound healing in a diabetic mouse model. In the present study, we extend those findings to the more translatable large animal porcine wound model and show that the combined treatment promotes wound reepithelialization in these excisional wounds by 40.2% and increases the CD31 immunostaining marker of angiogenesis compared with the matrix control, while maintaining an accumulated timolol plasma concentration below the clinically safe level of 0.3 ng/mL after the 15-day course of topical application. Human GAPDH was not elevated in the day 15 wounds treated with MSC-containing device relative to wounds treated with matrix alone, indicating that the xenografted human MSCs in the treatment do not persist in these immune-competent animals after 15 days. The work demonstrates the efficacy and safety of the combined treatment for improving healing in the clinically relevant porcine wound model.


Asunto(s)
Trasplante de Células Madre Mesenquimatosas , Células Madre Mesenquimatosas , Animales , Modelos Animales de Enfermedad , Matriz Extracelular , Humanos , Trasplante de Células Madre Mesenquimatosas/métodos , Ratones , Porcinos , Timolol/farmacología , Cicatrización de Heridas
2.
Lab Anim ; 55(2): 170-176, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33108940

RESUMEN

Q fever is a worldwide zoonosis caused by Coxiella burnetii that can lead to abortion, endocarditis, and death in humans. Researchers utilizing parturient domestic ruminants, including sheep, have an increased risk of occupational exposure. This study evaluated the effectiveness of our screening protocol in eliminating C. burnetii-positive sheep from our facility. From August 2010 to May 2018, all ewes (N = 306) and select lambs (N = 272; ovis aries) were screened twice for C. burnetii utilizing a serum Phase I and Phase II antibody immunofluorescence assay (IFA). The first screen was performed by the vendor prior to breeding, and the second screen was performed on arrival to the research facility. Ewes that were positive on arrival screening were quarantined and retested using repeat IFA serology, enzyme-linked immunosorbent assay, buffy coat polymerase chain reaction (PCR), and amniotic fluid PCR. The overall individual seroprevalence of C. burnetii in the flocks tested by the vendor was 14.2%. Ewes with negative Phase I and Phase II IFA results were selected for transport to the research facility. Upon arrival to the facility, two (0.7%) ewes had positive Phase I IFA results. Repeat testing demonstrated seropositivity in one of these two ewes, though amniotic fluid PCR was negative in both. The repeat seropositive ewe was euthanized prior to use in a research protocol. No Q fever was reported among husbandry, laboratory or veterinary staff during the study period. Serologic testing for C. burnetii with IFA prior to transport and following arrival to a research facility limits potential exposure to research staff.


Asunto(s)
Monitoreo Epidemiológico/veterinaria , Tamizaje Masivo/veterinaria , Enfermedades Profesionales/prevención & control , Fiebre Q/prevención & control , Enfermedades de las Ovejas/epidemiología , Animales , California/epidemiología , Ensayo de Inmunoadsorción Enzimática/veterinaria , Técnica del Anticuerpo Fluorescente/veterinaria , Humanos , Tamizaje Masivo/estadística & datos numéricos , Reacción en Cadena de la Polimerasa/veterinaria , Vigilancia de la Población/métodos , Prevalencia , Medición de Riesgo/métodos , Estudios Seroepidemiológicos , Ovinos , Oveja Doméstica
3.
Circ Arrhythm Electrophysiol ; 11(2): e005852, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29437761

RESUMEN

BACKGROUND: Electrophysiological remodeling and increased susceptibility for cardiac arrhythmias are hallmarks of heart failure (HF). Ventricular action potential duration (APD) is typically prolonged in HF, with reduced repolarization reserve. However, underlying K+ current changes are often measured in nonphysiological conditions (voltage clamp, low pacing rates, cytosolic Ca2+ buffers). METHODS AND RESULTS: We measured the major K+ currents (IKr, IKs, and IK1) and their Ca2+- and ß-adrenergic dependence in rabbit ventricular myocytes in chronic pressure/volume overload-induced HF (versus age-matched controls). APD was significantly prolonged only at lower pacing rates (0.2-1 Hz) in HF under physiological ionic conditions and temperature. However, when cytosolic Ca2+ was buffered, APD prolongation in HF was also significant at higher pacing rates. Beat-to-beat variability of APD was also significantly increased in HF. Both IKr and IKs were significantly upregulated in HF under action potential clamp, but only when cytosolic Ca2+ was not buffered. CaMKII (Ca2+/calmodulin-dependent protein kinase II) inhibition abolished IKs upregulation in HF, but it did not affect IKr. IKs response to ß-adrenergic stimulation was also significantly diminished in HF. IK1 was also decreased in HF regardless of Ca2+ buffering, CaMKII inhibition, or ß-adrenergic stimulation. CONCLUSIONS: At baseline Ca2+-dependent upregulation of IKr and IKs in HF counterbalances the reduced IK1, maintaining repolarization reserve (especially at higher heart rates) in physiological conditions, unlike conditions of strong cytosolic Ca2+ buffering. However, under ß-adrenergic stimulation, reduced IKs responsiveness severely limits integrated repolarizing K+ current and repolarization reserve in HF. This would increase arrhythmia propensity in HF, especially during adrenergic stress.


Asunto(s)
Potenciales de Acción/fisiología , Agonistas Adrenérgicos beta/farmacología , Calcio/metabolismo , Insuficiencia Cardíaca/metabolismo , Ventrículos Cardíacos/metabolismo , Miocitos Cardíacos/metabolismo , Potasio/farmacocinética , Animales , Modelos Animales de Enfermedad , Insuficiencia Cardíaca/patología , Insuficiencia Cardíaca/fisiopatología , Ventrículos Cardíacos/efectos de los fármacos , Ventrículos Cardíacos/patología , Masculino , Miocitos Cardíacos/efectos de los fármacos , Miocitos Cardíacos/patología , Potasio/metabolismo , Conejos
4.
ASAIO J ; 61(4): 443-7, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25794246

RESUMEN

Durable mechanical support in situations of physiologic single ventricle has been met with little success so far, particularly in small children. We created an animal model to investigate whether pulsatile or continuous flow would be superior. Three 1 month old sheep (10-16 kg) were instrumented. Via sternotomy and with cardiopulmonary bypass, a large ventricular septal defect and atrial septal defect were created. The left ventricle was cannulated using a Berlin Heart inflow cannula. This was connected sequentially to a continuous flow device (Thoratec HeartMate X, Pleasanton, CA) and to a pulsatile device (Berlin Heart Excor, The Woodlands, TX). Outflow was via a Y-graft to both aorta and pulmonary artery, striving for equal flow to both. Atrial filling pressures were controlled with volume infusions over a wide range. Under comparable loading conditions, significantly higher maximum flow was obtained by HeartMate X than by Excor (4.95 ± 1.27 L/min [range, 3.84-6.34 L/min] for HeartMate X vs. 1.80 ± 0.85 L/min [range, 1.01-2.7 L/min] for Excor; p < 0.05). Judging from this limited animal study, in single ventricle scenarios, continuous flow devices may achieve higher pump flows than pulsatile devices when provided with similar filling pressures. Their clinical use should be investigated. More extensive experimental studies are needed.


Asunto(s)
Cardiopatías Congénitas/complicaciones , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar , Flujo Pulsátil/fisiología , Animales , Modelos Animales de Enfermedad , Proyectos Piloto , Oveja Doméstica
5.
ASAIO J ; 61(3): 332-8, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25635937

RESUMEN

Telemetric physiological monitoring systems (TPMS) have enabled accurate continuous measurement of animal blood pressures and flows. However, few studies describe approaches for use of TPMS in the great vessels or inside the heart. We describe our initial experiences using two types of TPMSs. Twelve lambs (20-37 kg) underwent sternotomy. Two lambs were not instrumented and were killed at 14 days to confirm normal sternal wound healing (sham group, n = 2). Ten lambs underwent placement of either standard indwelling pressure-monitoring catheter and perivascular-flow-probe (CFP group, n = 3) or TPMS implantation (TPMS group, n = 7). The TPMS used were EG1-V3S2T-M2 (EG1, n = 5; Transonic Endogear Inc.) and Physio Tel Digital L21 (PTD, n = 2; Data Sciences Inc.). Two deaths because of respiratory problems occurred in TPMS group, attributed to lung compression by the implanted device. In TPMS group, more consistent trends of blood pressures and flows were recorded, and management of animals was easier and less labor-intensive. Comparing the two TPMSs, the initiation and renewal costs for each case was $28 K vs. $20 K and $1,700 vs. $0, (PTD versus EG1, respectively). In conclusion, TPMS implantation was feasible via median sternotomy in lambs. Telemetric physiological monitoring systems significantly improve reliability of hemodynamic monitoring in chronic survival animal study. EG1 was less costly than PTD.


Asunto(s)
Modelos Animales de Enfermedad , Hemodinámica/fisiología , Monitoreo Fisiológico/métodos , Telemetría/métodos , Animales , Ovinos , Esternotomía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...