Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Front Immunol ; 13: 945197, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36211435

RESUMEN

Background: Duodenal histology remains the diagnostic reference standard in celiac disease. However, traditional methods have suboptimal sensitivity and reproducibility for early mucosal changes and research purposes. We validated a recently introduced micro-CT imaging method for an accurate digital evaluation of duodenal histomorphometry and mucosal surface areas. Methods: Endoscopic biopsies from 58 individuals were utilized for the micro-CT imaging, selecting histological changes ranging from normal to severely damaged mucosa. The imaging protocol was optimized for practicability and resolution. The Bland-Altman method was applied to test intra- and interobserver variations in the blinded measurements. Results: The 3D micro-CT reconstructions enabled easy and precise digital cutting with optimal orientation and computer-assisted measurement of the surface area. Intraobserver analysis of morphological measurements showed a mean difference of 0.011 with limits of agreement (LA) from -0.397 to 0.375 and a standard deviation (SD) of 0.197. The corresponding figures for interobserver analysis were 0.080, from -0.719 to 0.537 and 0.320, respectively. The intraclass correlation coefficients (ICC) for the intraobserver and interobserver variations were 0.981 and 0.954, respectively. Intraobserver surface area analysis yielded a mean difference of 0.010, LA from -0.764 to 0.785 and an SD of 0.395, and an interobserver analysis mean difference of 0.028, LA from -0.642 to 0.698 and SD of 0.342. The respective ICCs for the intra- and interobserver variations were 0.963 and 0.972. Conclusions: Micro-CT showed excellent accuracy and reproducibility in the evaluation of mucosal morphometry and surface areas. The improved sensitivity for histological changes is a powerful tool for the diagnosis of celiac disease and for clinical and pharmacological studies.


Asunto(s)
Enfermedad Celíaca , Enfermedad Celíaca/diagnóstico por imagen , Enfermedad Celíaca/patología , Duodeno/diagnóstico por imagen , Humanos , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Microtomografía por Rayos X
2.
Commun Biol ; 3(1): 548, 2020 10 02.
Artículo en Inglés | MEDLINE | ID: mdl-33009501

RESUMEN

Development and study of cell-cultured constructs, such as tissue-engineering scaffolds or organ-on-a-chip platforms require a comprehensive, representative view on the cells inside the used materials. However, common characteristics of biomedical materials, for example, in porous, fibrous, rough-surfaced, and composite materials, can severely disturb low-energy imaging. In order to image and quantify cell structures in optically challenging samples, we combined labeling, 3D X-ray imaging, and in silico processing into a methodological pipeline. Cell-structure images were acquired by a tube-source X-ray microtomography device and compared to optical references for assessing the visual and quantitative accuracy. The spatial coverage of the X-ray imaging was demonstrated by investigating stem-cell nuclei inside clinically relevant-sized tissue-engineering scaffolds (5x13 mm) that were difficult to examine with the optical methods. Our results highlight the potential of the readily available X-ray microtomography devices that can be used to thoroughly study relative large cell-cultured samples with microscopic 3D accuracy.


Asunto(s)
Células Cultivadas/ultraestructura , Imagenología Tridimensional/métodos , Células Madre/ultraestructura , Microtomografía por Rayos X/métodos , Núcleo Celular/ultraestructura , Femenino , Humanos , Células Madre Mesenquimatosas/ultraestructura , Microscopía , Microscopía Fluorescente , Persona de Mediana Edad , Andamios del Tejido
3.
Sci Rep ; 10(1): 13164, 2020 08 04.
Artículo en Inglés | MEDLINE | ID: mdl-32753621

RESUMEN

The often poorly orientated small-bowel mucosal biopsies taken for the diagnostics of celiac disease and other intestinal disorders are prone to misinterpretation. Furthermore, conventional histopathology has suboptimal sensitivity for early histopathological changes observed in short-term challenge studies. X-ray microtomography (micro-CT) is a promising new method for accurate imaging of human-derived biological samples. Here, we report that micro-CT could be utilized to create virtual reconstructions of endoscopically obtained intestinal biopsies. The formed digital 3D images enabled selection of always optimal cutting angles for accurate measurement of the mucosal damage and revealed diagnostic lesions in cases interpreted as normal with conventional histomorphometry. We also demonstrate that computer-assisted point cloud analysis can be used to calculate biologically meaningful surface areas of the biopsies in different stages of mucosal damage with excellent replicability and correlation with other disease parameters. We expect the improved diagnostic accuracy and capability to measure the surface areas to provide a powerful tool for the diagnostics of intestinal diseases and for future clinical and pharmaceutical trials.


Asunto(s)
Enfermedad Celíaca/diagnóstico por imagen , Imagenología Tridimensional/métodos , Intestino Delgado/patología , Microtomografía por Rayos X/métodos , Adulto , Anciano , Biopsia , Estudios de Casos y Controles , Enfermedad Celíaca/patología , Endoscopía Gastrointestinal , Femenino , Humanos , Intestino Delgado/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Interpretación de Imagen Radiográfica Asistida por Computador , Sensibilidad y Especificidad
4.
Stem Cells Int ; 2018: 5928935, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29853915

RESUMEN

Polybutylene succinate (PBS) is a biodegradable polyester with better processability and different mechanical properties compared to polylactides (PLAs), the most commonly used synthetic polymers in tissue engineering (TE). Since only few studies have evaluated PBS-containing materials for bone TE, we prepared PLA-PBS blends and analyzed material properties as well as cell attachment, proliferation, and osteogenic differentiation of human mesenchymal stem cells (hMSCs) on scaffolds. In addition to PLA, PBS, and PLA-PBS blends, PLA-polycaprolactone and PLA-poly(trimethylene carbonate) blends were evaluated. Polymer fibers were prepared using melt spinning. Pure PBS was observed to have the highest crystallinity and strain at break compared to the tougher PLA and PLA blends. No degradation occurred during the 4-week hydrolysis in either of the materials. Knitted and rolled scaffolds were manufactured, seeded with hMSCs, and cultured for 27 days. Human MSC viability was good on all the materials, but cell spreading along the fibers was only detected in PBS-containing scaffolds. They also induced the strongest proliferative response and osteogenic differentiation, which diminished with decreasing PBS content. Based on these results, PBS is superior to PLA with respect to hMSC attachment, proliferation, and osteogenesis. This encourages utilizing PBS-based biomaterials more widely in bone TE applications.

5.
Annu Int Conf IEEE Eng Med Biol Soc ; 2015: 5626-9, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26737568

RESUMEN

Methods to image and assess the microstructure of polymer based biomaterials in liquid phase, for example cell culture medium, are well warranted. X-ray microtomography could provide a mean to visualize and analyze such structures. However, the density of such polymers is close to that of water and hence the X-ray contrast is poor. Moreover, if the biomaterials contain cells and are dried, the cell morphology may be distorted. In this paper we test phosphotungstic acid (PTA) staining to improve the contrast. We imaged collagen and PLA samples with µCT in air, water and alcohol. The methods were compared visually and with contrast to noise ratio calculated from the images. Our results demonstrate that with alcohol the PLA can be imaged also in liquid phase. PTA staining seems to be a good method to increase the contrast for collagen in µCT imaging.


Asunto(s)
Microtomografía por Rayos X , Materiales Biocompatibles , Colágeno , Poliésteres
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...