Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
J Clin Endocrinol Metab ; 100(6): 2261-7, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25867812

RESUMEN

CONTEXT: Relatively low radioiodine uptake (RAIU) represents a common obstacle for radioiodine ((131)I) therapy in patients with multinodular goiter complicated by hyperthyroidism. OBJECTIVE: To evaluate whether thiamazole (MTZ) pretreatment can increase (131)I therapeutic efficacy. DESIGN AND SETTING: Twenty-two patients with multinodular goiter, subclinical hyperthyroidism, and RAIU < 50% were randomized to receive either a low-iodine diet (LID; n = 10) or MTZ 30 mg/d (n = 12) for 42 days. Thyroid function and 24-hour RAIU were measured before and after treatment. Thyroid volume was evaluated by either magnetic resonance imaging or single photon emission computed tomography. RESULTS: Mean 24-hour RAIU increased significantly from 32 ± 10% to 63 ± 18% in the MTZ group (P < .001). Consequently, there was a 31% decrease in the calculated median therapeutic (131)I activity after MTZ (P < .05). No significant changes in 24-hour RAIU were observed after diet. In the MTZ group, median serum TSH levels increased significantly by 9% and mean serum free T4 and free T3 concentrations decreased by 22% and 15%, respectively, whereas no changes in thyroid function were observed in the LID group. Thyroid volume did not significantly change in either of the two groups. At 12 months after radioiodine treatment, median serum TSH was within the normal range in both groups. CONCLUSIONS: MTZ treatment before (131)I therapy resulted in an average 2-fold increase in thyroid RAIU and enhanced the efficiency of radioiodine therapy assessed at 12 months. MTZ pretreatment is therefore a safe, easily accessible alternative to recombinant human TSH stimulation and a more effective option than LID.


Asunto(s)
Antitiroideos/administración & dosificación , Bocio Nodular/tratamiento farmacológico , Bocio Nodular/radioterapia , Hipertiroidismo/tratamiento farmacológico , Hipertiroidismo/radioterapia , Radioisótopos de Yodo/administración & dosificación , Metimazol/administración & dosificación , Anciano , Anciano de 80 o más Años , Estudios de Casos y Controles , Terapia Combinada , Esquema de Medicación , Femenino , Bocio Nodular/complicaciones , Humanos , Hipertiroidismo/complicaciones , Masculino , Persona de Mediana Edad , Tamaño de los Órganos/efectos de los fármacos , Tamaño de los Órganos/efectos de la radiación , Dosificación Radioterapéutica , Pruebas de Función de la Tiroides , Glándula Tiroides/efectos de los fármacos , Glándula Tiroides/patología , Glándula Tiroides/efectos de la radiación
2.
Radiother Oncol ; 89(3): 270-7, 2008 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-18768229

RESUMEN

PURPOSE: Since 11C-methionine (MET) heavily accumulates in brain tumors, PET with MET (MET-PET) is proposed for the image-guided planning of their targeted therapy. Determination of bulk tumor limits is therefore a crucial component of MET-PET image analysis. We aimed at validating a Gaussian model of tumor delineation on MET-PET. We choose MET-PET and MRI data obtained in brain metastases to adjust the model. Indeed, MRI limits of these non-infiltrative hypermetabolic brain lesions are efficiently used for their curative treatment. METHODS AND MATERIALS: We developed a three-dimensional (3D) Gaussian model that relates the tumor-limit-defining threshold to maximum and mean count values in the defined tumor volume and to mean count values in a reference region. To adjust the model to experimental data, we selected 25 brain metastases following these criteria: (i) no surgery or classical radiotherapy within 6 months, (ii) no previous radiosurgery, (iii) MET-PET and MRI acquired within a 48-h interval, (vi) necrosis representing less than 25% of tumor volume on MRI. We applied a progressive thresholding procedure on MET-PET so as to match tumor limits on contrast-enhanced co-registered MRI. RESULTS: In 22 tumors, a match could be reached between tumor margins on MET-PET and MRI. The relation between mean, maximum and threshold values closely fits the 3D-Gaussian model function. We found a quadratic relation between the mean-to-threshold ratio and the maximum-to-cerebellum activity ratio. CONCLUSIONS: A 3D-Gaussian model may describe the limits of MET uptake distribution within brain metastases, providing a simple method for metabolic tumor delineation.


Asunto(s)
Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/secundario , Radioisótopos de Carbono , Tomografía de Emisión de Positrones , Imagen por Resonancia Magnética , Metionina , Distribución Normal
3.
Contrast Media Mol Imaging ; 3(4): 157-63, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18781582

RESUMEN

OBJECTIVE: The pre-operative technique most routinely used to localize pathological parathyroid glands (PPG), prior to minimal access surgery (MAS), relies on 99mTc-sestamibi (MIBI) scintigraphy. Positron emission tomography (PET) using the radiolabelled amino acid 11C-methionine as the tracer agent offers a technological alternative to localize PPG. In this study we evaluated the sensitivity of 11C-methionine PET/CT (MET-PET/CT) for PPG detection and the extent to which MET-PET/CT images may contribute to the planning of surgical procedures. DESIGN: Thirty patients were included, 22 with primary hyperparathyroidism and eight with secondary hyperparathyroidism. Patients suspected of suffering from parathyroid hyperplasia underwent a complete surgical exploration of the neck region. In those suspected of parathyroid adenoma, surgery was limited to the presumed localization described by MET-PET/CT. To specifically address the additional benefit of the MET-PET/CT in terms of surgical planning and procedure, the surgeon classified the patients into two categories depending on the type of benefit, or the reason for the absence of benefit, occurring in each case. We also compared the sensitivity of MET-PET/CT and MIBI scintigraphy. RESULTS: The total number of lesions removed was 46 (24 adenomatous and 22 hyperplastic). Globally, MET-PET/CT provided additional benefit to surgery in 15 out of 30 cases (50%). The sensitivity of 11C-methionine PET/CT and MIBI scintigraphy was respectively 92% and 95% for adenoma, and 68% and 59% for hyperplasia, on the basis of available resected lesions. CONCLUSION: MET-PET/CT appears a reliable technique to guide MAS of parathyroid glands.


Asunto(s)
Metionina , Glándulas Paratiroides/patología , Tomografía de Emisión de Positrones/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Radioisótopos de Carbono , Humanos , Persona de Mediana Edad , Glándulas Paratiroides/diagnóstico por imagen , Cuidados Preoperatorios/instrumentación , Cuidados Preoperatorios/métodos , Radiofármacos , Reproducibilidad de los Resultados
4.
J Clin Endocrinol Metab ; 92(12): 4719-24, 2007 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-17925341

RESUMEN

CONTEXT: The clinical evolution of autonomous thyroid nodules (ATN) is unpredictable, and thyrotoxicosis is observed at variable nodule size. In vitro data suggest that hydrogen peroxide production is decreased in ATN, indicating intranodular iodide organification impairment. OBJECTIVE: We aimed to determine iodide organification efficiency in ATN and its relationship with thyroid status in patients. DESIGN: Forty-six patients with a single ATN on the 123I thyroid scan were included in the study. Biological evaluation and iodine perchlorate (I-ClO4) discharge test were carried out in all subjects. SETTING: The study took place at an academic hospital. RESULTS: Among the 46 patients, 28 patients (61%) had a positive I-ClO4 discharge test with a mean +/- sd value of discharge of 42 +/- 13%, and 18 (39%) had a negative discharge test with mean +/- sd of 5 +/- 9%. In the group of patients with a negative discharge test but not in the group with a positive test, serum-free T3 and free T4 concentrations were significantly correlated with the 123I uptake. The severity of hyperthyroidism was not different between both groups. CONCLUSIONS: Intranodular iodide organification was impaired in most patients with ATN. Whether differences in organification capability could predict the risk for evolution to overt hyperthyroidism in patients with ATN remains to be established.


Asunto(s)
Yodo/metabolismo , Nódulo Tiroideo/metabolismo , Anciano , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Yoduro Peroxidasa/metabolismo , Radioisótopos de Yodo , Masculino , Persona de Mediana Edad , Percloratos , Cintigrafía , Nódulo Tiroideo/diagnóstico por imagen , Tirotropina/sangre , Tiroxina/sangre , Triyodotironina/sangre
7.
J Magn Reson Imaging ; 24(5): 989-94, 2006 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-17031832

RESUMEN

PURPOSE: To evaluate in brain gliomas the relationship between tumor vascularity measured by MR-based maximum regional cerebral blood volume (rCBV) and tumor amino-acid metabolism based on maximum carbon-11 methionine (MET) uptake on positron emission tomography (PET). MATERIALS AND METHODS: Eighteen patients with histologically proven primary brain gliomas were included in the study. In addition to conventional MR sequences, dynamic MR images, including a first-pass gadopentetate dimeglumine T2*-weighted echo-planar perfusion sequence and a PET study using MET, were acquired. Eleven patients had low-grade gliomas, and seven had high-grade gliomas. rCBV ratios and MET uptake ratios normalized to the contralateral white matter (WM) corresponding values were measured in each tumor. Both maximum rCBV ratios and maximum MET uptake ratios were correlated to histopathology. The maximum rCBV ratios were correlated to the maximum MET uptake ratios. RESULTS: Both the maximum rCBV ratios and maximum MET uptake ratios of high-grade gliomas were significantly higher than those of low-grade gliomas (P<0.05). There was a significant positive correlation between maximum rCBV ratios and maximum MET uptake ratios (Spearman: r=0.89, P<0.00001). CONCLUSION: The maximum rCBV ratio and maximum MET uptake ratio are significantly correlated in gliomas, reflecting a close link between amino acid uptake and vascularity in these tumors.


Asunto(s)
Neoplasias Encefálicas/irrigación sanguínea , Neoplasias Encefálicas/metabolismo , Glioma/irrigación sanguínea , Glioma/metabolismo , Imagen por Resonancia Magnética/métodos , Metionina/análogos & derivados , Tomografía de Emisión de Positrones/métodos , Adulto , Anciano , Neoplasias Encefálicas/diagnóstico , Circulación Cerebrovascular , Medios de Contraste , Femenino , Glioma/diagnóstico , Humanos , Masculino , Metionina/farmacocinética , Persona de Mediana Edad , Proyectos Piloto , Radiofármacos/farmacocinética , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Estadística como Asunto
8.
J Neurooncol ; 71(2): 161-8, 2005 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-15690133

RESUMEN

UNLABELLED: 11C-Methionine (MET) is a useful positron emission tomography (PET) tracer for the evaluation of low-grade gliomas. Among these tumors, a high percentage of low-grade oligodendrogliomas (ODG) are sensitive to chemotherapy with procarbazine, CCNU, and vincristine (PCV). We aimed at: (1) objectively assessing ODG response to PCV by a metabolic index (the Activity Volume Index or AVI) generated from an automated semi-quantification of PET with MET (PET-MET); (2) comparing AVI and quantitative magnetic resonance imaging (MRI) measurements of response to PCV. METHODS: seven patients with ODG were followed for a period of 19.9+/-6.6 months after the completion of PCV chemotherapy. Regions of interest (ROI) were generated by covering all voxels with count values above a threshold level set at 120% of the mean cerebellar activity. On each slice, ROI volume and mean count values were calculated. AVI was calculated as the sum over all ROI of tumor volumex(tumor mean count/cerebellum count). Tumor volume measurements on MRI, were based on signal abnormalities visually detected on fluid-attenuated inversion recovery (FLAIR) sequences. RESULTS: PCV therapy was associated with a drastic decrease in AVI (mean+/-SD, cm3): AVI post-PCV=0.80+/-1.45 vs. AVI prior PCV=12.94+/-11.46 (P=0.03). Likewise, we observed a decrease in tumor volume estimated from the FLAIR signal (31.37+/-11.99 post-PCV vs. 67.95+/-39.96 prior PCV, P=0.03) although AVI decrease after PCV was significantly more pronounced (P=0.015). CONCLUSION: This study, based on limited number of patients and follow-up period indicates that AVI may be a sensitive and observer-independent method applicable to the assessment of ODG responsiveness to PCV treatment and may offer a major added value to both clinical assessment and MRI evaluation of chemotherapeutic outcomes.


Asunto(s)
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Neoplasias Encefálicas/tratamiento farmacológico , Lomustina/uso terapéutico , Imagen por Resonancia Magnética , Metionina/farmacocinética , Oligodendroglioma/tratamiento farmacológico , Tomografía de Emisión de Positrones , Procarbazina/uso terapéutico , Vincristina/uso terapéutico , Adulto , Anciano , Neoplasias Encefálicas/diagnóstico , Neoplasias Encefálicas/metabolismo , Neoplasias Encefálicas/patología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Oligodendroglioma/diagnóstico , Oligodendroglioma/metabolismo , Oligodendroglioma/patología , Resultado del Tratamiento
9.
Eur J Nucl Med Mol Imaging ; 31(11): 1487-94, 2004 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-15232656

RESUMEN

PURPOSE: Accurate diagnosis of Alzheimer's disease (AD), the most common form of dementia, remains difficult. In order to assess whether fully automated stereotactic surface projection (3D-SSP) presentation contributes to the diagnosis of AD by single-photon emission computed tomography (SPECT), we investigated the diagnostic accuracy of transaxial display with and without 3D-SSP analysis as well as the correlation between cerebral perfusion in different cortical areas and the mini mental score (MMS). METHODS: Seventy-two patients referred because of cognitive impairment were included in the study. According to the National Institute of Neurological and Communicative Disorders and Stroke (NINCDS) and the Alzheimer's disease and Related Disorders Association (ADRDA) criteria, 27 patients were diagnosed as having probable AD while 45 were classified as non-AD patients. 3D-SSP was used to quantify the regional cerebral blood flow (rCBF) acquired from SPECT imaging. RESULTS: Compared with the transaxial section presentation alone, 3D-SSP presentation improved the area under the receiver operating curve (p<0.05) as well as intra-observer (k=0.73 vs 0.88) and inter-observer (k=0.50 vs 0.84) reproducibility. Upon normalisation of regional to thalamic activity, multiple regression analysis revealed a strong correlation between the MMS and rCBF in the right parietal cortex (p=0.002). CONCLUSION: Addition of 3D-SSP to the transaxial section display of ECD-SPECT studies improves the reproducibility and the diagnostic performance in respect of AD in patients with cognitive impairment and provides a valid tool for assessment of the severity of cortical perfusion abnormalities in such patients.


Asunto(s)
Enfermedad de Alzheimer/diagnóstico por imagen , Enfermedad de Alzheimer/fisiopatología , Encéfalo/irrigación sanguínea , Encéfalo/diagnóstico por imagen , Circulación Cerebrovascular , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Enfermedad de Alzheimer/clasificación , Inteligencia Artificial , Velocidad del Flujo Sanguíneo , Mapeo Encefálico/métodos , Femenino , Humanos , Aumento de la Imagen/métodos , Masculino , Persona de Mediana Edad , Cintigrafía , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA