Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 61
Filtrar
1.
JACC Clin Electrophysiol ; 9(8 Pt 2): 1475-1486, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37278684

RESUMEN

BACKGROUND: We previously reported feasibility of irrigated needle ablation (INA) with a retractable 27-G end-hole needle catheter to treat nonendocardial ventricular arrhythmia substrate, an important cause of ablation failure. OBJECTIVES: The purpose of this study was to report outcomes and complications in our entire INA-treated population. METHODS: Patients with recurrent sustained monomorphic ventricular tachycardia (VT) or high-density premature ventricular contractions (PVCs) despite radiofrequency ablation were prospectively enrolled at 4 centers. Endpoints included a 70% decrease in VT frequency or PVC burden decrease to <5,000/24 h at 6 months. RESULTS: INA was performed in 111 patients (median: 2 failed prior ablations, 71% nonischemic heart disease, and left ventricular ejection fraction 36% ± 14%). INA acutely abolished targeted PVCs in 33 of 37 patients (89%), and PVCs were reduced to <5,000/day in 29 patients (78%). During 6-month follow-up, freedom from hospitalization was observed in 50 of 72 patients with VT (69%), and improvement or abolition of VT occurred in 47%. All patients received multiple INA applications, with more in the VT group than in the PVC group (median: 12 [IQR: 7-19] vs 7 [5-15]; P < 0.01). After INA, additional endocardial standard radiofrequency ablation was required in 23% of patients. Adverse events included 4 pericardial effusions (3.5%), 3 cases of (anticipated) atrioventricular block (2.6%), and 3 heart failure exacerbations (2.6%). During 6-month follow-up, 5 deaths occurred; none were procedure-related. CONCLUSIONS: INA achieves improved arrhythmia control in 78% of patients with PVCs and avoids hospitalization in 69% of patients with VT refractory to standard ablation at 6-month follow-up. Procedural risks are acceptable. (Intramural Needle Ablation for Ablation of Recurrent Ventricular Tachycardia, NCT01791543; Intramural Needle Ablation for the Treatment of Refractory Ventricular Arrhythmias, NCT03204981).


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Complejos Prematuros Ventriculares , Humanos , Ablación por Catéter/efectos adversos , Volumen Sistólico , Función Ventricular Izquierda
2.
Circ J ; 87(12): 1711-1719, 2023 11 24.
Artículo en Inglés | MEDLINE | ID: mdl-37258224

RESUMEN

BACKGROUND: Pulmonary vein stenosis (PVS) after PV isolation (PVI) for atrial fibrillation (AF) is a severe complication that requires angioplasty. This study aimed to compare the reduction of the cross-sectional PV area (PVA) and the incidence of PVS after cryoballoon (CB)-PVI, hot balloon (HB)-PVI, or laser balloon (LB)-PVI.Methods and Results: A total of 320 patients who underwent an initial catheter ablation procedure for AF using a CB, HB, or LB in 2 hospitals were included. They underwent contrast-enhanced multidetector CT before and 3 months after the procedure. In all 4 PVs, the reduction in PVA was more significant in the LB group than in the CB or HB groups, respectively. Moderate (50-75%) and severe (>75%) PVS were observed in 5.3% and 0.5% of the PVs, respectively. Although moderate PVS was more frequently observed in the LB group than in the CB or HB groups (8.2%, 3.8%, and 5.0%; P=0.03), the incidence of severe PVS was similar in the LB, CB, and HB groups (0.3%, 0.5%, and 1.0%; P=0.46). Symptomatic PVS requiring intervention occurred in 1 (0.3%) patient. CONCLUSIONS: Although the reduction in cross-sectional PVA and the incidence of moderate PVS after LB-PVI was more significant than after CB-PVI or HB-PVI, it rarely led to severe PVS. Symptomatic PVS requiring intervention was rare after the balloon ablation of AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Estenosis de Vena Pulmonar , Humanos , Estenosis de Vena Pulmonar/diagnóstico por imagen , Estenosis de Vena Pulmonar/etiología , Estudios Transversales , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Criocirugía/efectos adversos , Criocirugía/métodos , Resultado del Tratamiento , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Rayos Láser
3.
Heart Vessels ; 38(3): 413-421, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36194289

RESUMEN

The "pre-freezing" technique was a method in which a fully inflated balloon after the start of freezing was pressed against the pulmonary vein (PV) during cryoballoon ablation and has been applied especially in large-size PVs. Of 556 patients who underwent cryoballoon ablation for atrial fibrillation (AF), the pre-freezing technique was applied to 48 patients. The resulting 2:1 propensity score-matched data set included 120 patients. Using the pre-freezing technique, all left-superior PVs, all left-inferior PVs, and 95% of right-superior PVs were successfully isolated. In most right-inferior PVs, complete sealing using the pre-freezing technique was challenging, and this technique was not applied. Procedure time was similar between the two groups. In the pre-freezing group, the percentage of the left atrial posterior wall isolated was larger (47.6 ± 10.3 vs. 42.8 ± 15.7%, P = 0.006), and the postoperative reduction of diaphragmatic compound motor action potentials tended to occur less frequently (2.5 vs. 12.5%, P = 0.07), and the reduction of the cross-sectional LSPV area was smaller (17.5 ± 12.2 vs. 27.2 ± 19.8%, P = 0.03) than the conventional group. The AF-free rate of the two groups was similar between the two groups (P = 0.15). The pre-freezing technique was a simple method that can isolate a wider surface area during cryoballoon PV isolation. While the postoperative AF recurrence was comparable, the postoperative reduction in the cross-sectional PV area was less than that of the conventional method, which may reduce the risk of PV stenosis.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Venas Pulmonares/cirugía , Congelación , Estudios Transversales , Criocirugía/efectos adversos , Criocirugía/métodos , Resultado del Tratamiento
4.
J Cardiovasc Electrophysiol ; 33(9): 2100-2103, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35842800

RESUMEN

INTRODUCTION: Catheter ablation for atrial fibrillation (AF) in patients with tachycardia-bradycardia syndrome (TBS) can be a major therapeutic option to replace permanent pacemaker implantation (PMI). However, the very long-term outcome of more than 15 years in these patients has not been elucidated. METHODS: From 2002 to 2008, 25 consecutive TBS patients (62 ± 7.9 years old, 68% male) with both AF and symptomatic sinus pauses (>3.0 s) were performed radiofrequency AF ablation. These patients were followed for 15 ± 2.7 years. RESULTS: The median longest sinus pause before the ablation procedure was 6.0 s (4.4-8.0). Following 1.6± 0.8 ablation procedures, 18 (72%) patients remained free from AF. Three (12%) patients died due to noncardiovascular causes, and seven (28%) patients underwent PMI due to symptomatic sinus pause after recurrent AF in five patients and progression of sinus node dysfunction in two patients. The median duration from the first AF ablation to PMI was 6.3 years (range: 9 days to 11.0 years). Five and two patients required PMI more than 5 and 10 years after the first ablation procedure, respectively. CONCLUSION: AF ablation prevented PMI in 72% of TBS patients for a 15-year follow-up. However, in consideration of the long duration of PMI, a continuous careful long-term follow-up was warranted.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Bradicardia , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Síndrome del Seno Enfermo/terapia , Taquicardia/diagnóstico , Taquicardia/cirugía , Resultado del Tratamiento
5.
Int J Cardiol Heart Vasc ; 40: 101020, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35434257

RESUMEN

Background: It was previously reported, based on a retrospective study, that preliminary removal of air bubbles in heparinized saline water with extracorporeal balloon inflation reduced the incidence of asymptomatic cerebral embolism (ACE). The present study aims to compare the incidence of ACE between a conventional and pre-inflation method during cryoballoon ablation in a prospective randomized controlled study. Methods: A total of 98 atrial fibrillation patients were enrolled and randomized into conventional and pre-inflation groups. Patients in the pre-inflation group received balloon massaging with preliminary extracorporeal balloon inflation in saline water before the cryoballoon was inserted into the body. Results: The baseline characteristics were similar between the two groups. Post-procedural 3-Tesla MRI revealed CE in 27.6% of patients. Symptomatic CE only occurred in two patients in the pre-inflation group. One patient had transient dysarthria and mild muscle weakness in one hand; the other patient complained of transient left upper limb weakness, left lower limb paresthesia and dysarthria. The incidence of ACE detected by cerebral MRI did not differ between the two groups to a statistically significant extent (conventional vs. pre-inflation; 22.9% vs. 29.2%; P = 0.49). In the multivariable analysis, eGFR was independently associated with the presence of ACE (odds ratio 0.95; 95% confidence interval 0.907-0.995; P = 0.03). Conclusion: In this prospective randomized study, the preliminary removal of air bubbles in heparinized saline water with extracorporeal balloon inflation had no impact on the incidence of ACE.

6.
Circ Arrhythm Electrophysiol ; 15(5): e010020, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35476455

RESUMEN

BACKGROUND: Frequent premature ventricular contractions (PVCs) are often amenable to catheter ablation. However, a deep intramural focus may lead to failure due to inability of standard ablation techniques to penetrate the focus. We sought to assess the efficacy and safety of infusion needle ablation (INA) for PVCs that are refractory to standard radiofrequency ablation. METHODS: Under 2 Food and Drug Administration approved protocols, INA was evaluated in patients with frequent PVCs that were refractory to standard ablation. Initial targets for ablation were selected by standard mapping techniques. INA was performed with a deflectable catheter equipped with an extendable/retractable needle at the tip that can be extended up to 12 mm into the myocardium and is capable of pacing and recording. After contrast injection for location assessment, radiofrequency ablation was performed with the needle tip using a temperature-controlled mode (maximum temperature 60 °C) with saline infusion from the needle. The primary end point was a decrease in PVC burden to <5000/24 hours at 6 months. The primary safety end point was incidence of procedure- or device-related serious adverse events. RESULTS: At 4 centers, 35 patients (age 55.3±16.9 years, 74.2% male) underwent INA. The baseline median PVC burden was 25.4% (interquartile range, 18.4%-33.9%) and mean left ventricular ejection fraction was 37.7±12.3%. Delivering 10.3±8.0 INA lesions/patient (91% had adjunctive standard radiofrequency ablation also) resulted in acute PVC elimination in 71.4%. After a mean follow-up of 156±109 days, the primary efficacy end point was met in 73.3%. The median PVC burden decreased to 0.8% (interquartile range, 0.1%-6.0%; P<0.001). The primary safety end point occurred in 14.3% consisting of 1 (2.9%) heart block, 1 (2.9%) femoral artery dissection, and 3 (8.6%) pericardial effusions (all treated percutaneously). CONCLUSIONS: INA is effective for the elimination of frequent PVCs that are refractory to conventional ablation and is associated with an acceptable safety profile. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT01791543 and NCT03204981.


Asunto(s)
Ablación por Catéter , Complejos Prematuros Ventriculares , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/cirugía
7.
Heart Vessels ; 37(1): 110-114, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34216250

RESUMEN

The temporal changes in ambulatory monitoring findings after cryoballoon (CB) ablation of atrial fibrillation (AF) have not been well elucidated. This study aims to compare the details of ambulatory monitoring after CB and radiofrequency catheter (RFC) ablation for AF. Of 724 consecutive AF patients who underwent initial ablation using a CB or RFC, 508 (254 pairs) were selected using propensity score matching. Ambulatory monitoring was performed at 1, 3, 6, 12, 24 and 36 months after the procedure. After 1, 3 and 6 months, the number of total heart beats (THBs) was larger in the CB group than in the RFC group. It gradually decreased and became significantly similar by 12 months after ablation. THBs significantly increased 1, 3, 6 and 12 months after ablation in both the RFC and CB groups and became statistically similar by 24 months after ablation. The atrial premature contraction burden was higher in the RFC group than in the CB group at 3 months after ablation. THB and APC burden after AF ablation were significantly different between the RF and CB groups. THBs returned to statistically similarity by 2 years after ablation in both groups.


Asunto(s)
Fibrilación Atrial , Complejos Atriales Prematuros , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Complejos Atriales Prematuros/diagnóstico , Criocirugía/efectos adversos , Frecuencia Cardíaca , Humanos , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
8.
Sci Rep ; 11(1): 23591, 2021 12 08.
Artículo en Inglés | MEDLINE | ID: mdl-34880293

RESUMEN

The optimal ablation strategy for persistent atrial fibrillation (PsAF) remains to be defined. We sought to compare very long-term outcomes between linear ablation and electrogram (EGM)-guided ablation for PsAF. In a retrospective analysis, long-term arrhythmia-free survival compared between two propensity-score matched cohorts, one with pulmonary vein isolation (PVI) and linear ablation including roof/mitral isthmus line (LINE-group, n = 52) and one with PVI and EGM-guided ablation (EGM-group; n = 52). Overall, 99% of patients underwent successful PVI. Complete block following linear ablation was achieved for 94% of roof lines and 81% of mitral lines (both lines blocked in 75%). AF termination by EGM-guided ablation was accomplished in 40% of patients. Non-PV foci were targeted in 7 (13%) in the LINE-group and 5 (10%) patients in the EGM-group (p = 0.76). During 100 ± 28 months of follow-up, linear ablation was associated with superior arrhythmia-free survival after the initial and last procedure (1.8 ± 0.9 procedures) compared with EGM-group (Logrank test: p = 0.0001 and p = 0.045, respectively). In multivariable analysis, longer AF duration and EGM-guided ablation remained as independent predictors of atrial arrhythmia recurrence. Linear ablation might be a more effective complementary technique to PVI than EGM-guided ablation for PsAF ablation.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Puntaje de Propensión , Venas Pulmonares/cirugía , Recurrencia , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
10.
Sci Rep ; 11(1): 6226, 2021 03 18.
Artículo en Inglés | MEDLINE | ID: mdl-33737633

RESUMEN

While phrenic nerve palsy (PNP) due to cryoballoon pulmonary vein isolation (PVI) of atrial fibrillation (AF) was transient in most cases, no studies have reported the results of the long-term follow-up of PNP. This study aimed to summarize details and the results of long-term follow-up of PNP after cryoballoon ablation. A total of 511 consecutive AF patients who underwent cryoballoon ablation was included. During right-side PVI, the diaphragmatic compound motor action potential (CMAP) was reduced in 46 (9.0%) patients and PNP occurred in 29 (5.7%) patients (during right-superior PVI in 20 patients and right-inferior PVI in 9 patients). PNP occurred despite the absence of CMAP reduction in 0.6%. The PV anatomy, freezing parameters and the operator's proficiency were not predictors of PNP. While PNP during RSPVI persisted more than 4 years in 3 (0.6%) patients, all PNP occurred during RIPVI recovered until one year after the ablation. However, there was no significant difference in the recovery duration from PNP between PNP during RSPVI and RIPVI. PNP occurred during cryoballoon ablation in 5.7%. While most patients recovered from PNP within one year after the ablation, PNP during RSPVI persisted more than 4 years in 0.6% of patients.


Asunto(s)
Angioplastia de Balón/efectos adversos , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Parálisis/diagnóstico , Traumatismos de los Nervios Periféricos/diagnóstico , Nervio Frénico/lesiones , Anciano , Fibrilación Atrial/patología , Criocirugía/instrumentación , Criocirugía/métodos , Humanos , Masculino , Persona de Mediana Edad , Parálisis/etiología , Parálisis/patología , Traumatismos de los Nervios Periféricos/etiología , Traumatismos de los Nervios Periféricos/patología , Venas Pulmonares/cirugía , Factores de Tiempo , Resultado del Tratamiento
12.
Heart Rhythm ; 17(3): 398-405, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31604127

RESUMEN

BACKGROUND: Intramural substrate causing ventricular tachycardia can be targeted by radiofrequency (RF) infusion-needle catheter ablation. OBJECTIVE: The purpose of the study was to assess fluid distribution within the myocardium after needle-ablation catheter infusion and its evidence to RF lesion creation. METHODS: In 25 patients (21 (84%) male; 67 ± 9 years; 8 (32%) with ischemic cardiomyopathy) intramural ablation of ventricular tachycardia was performed with a needle catheter. Fluoroscopic images of myocardial staining patterns produced by pre-RF saline/contrast infusion were analyzed. Lesion creation was defined as tissue inexcitability to high-output needle pacing. RESULTS: Data from 155 sites were eligible for analysis. Tissue staining was evident in 111 (72%) and absent in 44 (28%). The stain shapes were variable, with average dimensions of 20 ± 10 × 8 ± 4 mm with an area of 68 ± 58 mm2. Round/oval-shaped stains were most common (62 [56%]), while multisegmented (36 [32%]) and long flat (13 [12%]) configurations were less frequent. Evidence of staining was associated with evidence of lesion creation (92/111 (83%) vs 17/44 (39%); P ≤ .0001). Contrast staining around the needle was present in 50%, usually had blurred margins, and was associated with lesion creation. When staining extended well beyond the needle, the margins were often sharp, suggesting dissection through tissue planes, and lesion creation tended to be less effective. CONCLUSION: With infusion-needle ablation, preablation injection of contrast can help confirm an intramural position and predict lesion creation. Tissue diffusion patterns vary markedly, and studies to assess its relation to tissue architecture and ablation lesion geometry warrants further investigation. The findings also have implications for the injection of therapeutic agents into the regions of scar.


Asunto(s)
Ablación por Catéter/instrumentación , Miocardio/patología , Cirugía Asistida por Computador/métodos , Taquicardia Ventricular/cirugía , Anciano , Diseño de Equipo , Femenino , Fluoroscopía , Humanos , Masculino , Agujas , Pronóstico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatología
13.
JACC Clin Electrophysiol ; 5(11): 1303-1315, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31753437

RESUMEN

OBJECTIVES: This study examined the anatomical or procedural factors associated with severe pulmonary vein (PV) stenosis after cryoballoon PV isolation. BACKGROUND: PV stenosis is a complication associated with cryoballoon ablation. METHODS: The study included 170 consecutive patients with paroxysmal atrial fibrillation who underwent cryoballoon ablation. In addition to factors generally considered to be related to the occurrence of PV stenosis (PV size, cryoballoon application number and time, and minimum freezing temperature), we evaluated the following 4 factors: 1) depth of balloon position; 2) the PV angle (internal angle between each PV and horizontal line); 3) noncoaxial balloon placement (hemispherical occlusion); and 4) contact surface area between the cryoballoon and the PV wall (defined as the balloon contact ratio). RESULTS: Severe PV stenosis (≥75% area reduction) was observed in 9 (1.3%) PVs (6 left superior and 3 right superior PVs) in 9 patients. The PV size, cryoballoon application number and time, minimum freezing temperature, and the depth of cryoballoon position were not significantly associated with occurrence of severe PV stenosis, but the PV angle was significantly smaller in PVs with severe stenosis than it was in those without stenosis (25.6 ± 9.7° vs. 34.2 ± 6.4°; p < 0.001). Hemispherical occlusion was more frequently observed and balloon contact ratio was larger in PVs with severe stenosis (55.6% vs. 14.8%; p = 0.049) than in those without stenosis (0.70 ± 0.06 vs. 0.54 ± 0.08; p < 0.001). CONCLUSIONS: A horizontally connecting PV, noncoaxial placement of cryoballoon, and a larger contact surface area of the cryoballoon were predictors of the occurrence of severe PV stenosis after cryoballoon ablation.


Asunto(s)
Fibrilación Atrial/cirugía , Criocirugía/métodos , Complicaciones Posoperatorias/epidemiología , Venas Pulmonares/cirugía , Estenosis de Vena Pulmonar/epidemiología , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Venas Pulmonares/anatomía & histología , Índice de Severidad de la Enfermedad
14.
J Cardiovasc Electrophysiol ; 30(11): 2310-2318, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31452290

RESUMEN

BACKGROUND: The presence of heart failure (HF) has been associated with poorer outcomes in patients undergoing catheter ablation (CA) for atrial fibrillation (AF). However, the effectiveness of CA amongst the subset of patients with tachycardia-induced cardiomyopathy (TIC) remains poorly defined. METHODS AND RESULTS: In a retrospective analysis we compared outcomes of first-time CA for persistent AF in a cohort of patients with previously diagnosed TIC (n = 45; age 58 ± 8 years; 91% male) to those with structurally normal hearts (non-TIC; n = 440; age 55 ± 9 years; 95% male). TIC was defined as an impaired ventricular function (left ventricular ejection function [LVEF] <50%), which was reversed after the treatment of HF. We compared atrial arrhythmias (AAs) recurrence after the CA in the TIC and non-TIC cohorts. In the TIC group, LVEF improved from 35.8% ± 8.1% to 57.5% ± 8.3% after treatment of HF. During 3.3 ± 1.5 years follow-up, AAs-free survival after CA was significantly higher in the TIC group as compared with the non-TIC group (69% vs 42%; P = .001), despite a comparable CA strategy between the two groups. In multivariable analysis, absence of HF with TIC, longer AF duration, and complex fractionated atrial electrogram ablation were independent predictors of arrhythmia recurrence (OR, 1.02; 95% CI, 1.01-1.03; P < .01; OR, 0.40; 95% CI, 0.20-0.79; P < .01 and OR, 2.29; 95%CI; 1.27-4.11; P < .01, respectively). In addition, the outcome after the last procedure was superior in the TIC cohort (89% vs 72%; P = .03) with fewer CA procedures as compared with the non-TIC cohort (1.3 ± 0.5 vs 1.5 ± 0.7; P = .01). CONCLUSIONS: Persistent patients with AF with TIC have a more favorable outcome after the CA as compared with those without.


Asunto(s)
Fibrilación Atrial/cirugía , Cardiomiopatías/etiología , Ablación por Catéter , Potenciales de Acción , Anciano , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/fisiopatología , Ablación por Catéter/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Recuperación de la Función , Recurrencia , Estudios Retrospectivos , Factores de Riesgo , Volumen Sistólico , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Izquierda
15.
PLoS One ; 14(7): e0219269, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31265482

RESUMEN

OBJECTIVES: One of the mechanisms of early recurrence of atrial fibrillation (ERAF) after AF ablation is considered to be the inflammatory reaction of the atrial tissue. The aim of this study is to compare the clinical significance of ERAF at each stage for true AF recurrence between cryoballoon (CB) and radiofrequency (RF) ablation. METHODS: Among 798 paroxysmal AF patients who underwent an initial ablation, 460 patients (CB, n = 230; RF, n = 230) were selected by propensity score matching. Very ERAF (VERAF), ERAF-1M, ERAF-3M and true AF recurrence were defined as AF recurrence at 0-2, 3-30, 31-90 days and more than 90 days after the procedure, respectively. RESULTS: The patient characteristics of the two groups were similar. ERAF was observed 21% and 27% in the CB and RF groups, respectively. In both the CB and RF group, VERAF, ERAF-1M and ERAF-3M were more frequently observed in patients with true AF recurrence than in those without. In a multivariable analysis, ERAF-1M and ERAF-3M were found to be independent predictors of true AF recurrence in both the CB (P = 0.04 and P<0.001, respectively) and RF groups (P = 0.02 and P = 0.001, respectively). However, while VERAF was associated with true AF recurrence after RF ablation (P = 0.03), it was not associated with true AF recurrence after CB ablation (P = 0.19). CONCLUSION: The relationship between ERAF and true AF recurrence differed between the RF and CB ablation groups. While VERAF was associated with true AF recurrence after RF ablation, it was not a predictor of true AF recurrence after CB ablation.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Criocirugía , Puntaje de Propensión , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Recurrencia
16.
J Am Coll Cardiol ; 73(12): 1413-1425, 2019 04 02.
Artículo en Inglés | MEDLINE | ID: mdl-30922472

RESUMEN

BACKGROUND: Catheter ablation is effective for eliminating most drug-refractory ventricular arrhythmias (VA). However, a major reason for procedural failure is arrhythmia originating deep within the myocardium where it is inaccessible to conventional endocardial or epicardial approaches. Affected patients have limited therapeutic options. OBJECTIVES: The objective of this study was to assess the safety and outcome of a novel radiofrequency ablation catheter that used an extendable/retractable 27-g needle capable of targeting deep arrhythmia (intramural) substrate. METHODS: Patients who failed at least one prior catheter ablation procedure for sustained ventricular tachycardia (VT) or nonsustained VA with associated left ventricular dysfunction were enrolled at 3 centers. The target was sustained monomorphic VT in 26 patients, including 8 with recent VT storm or VT requiring intravenous medication, and 5 with incessant VA associated with ventricular dysfunction. RESULTS: Needle ablation was performed in 31 patients (median of 2 failed prior ablation procedures; 71% nonischemic heart disease). After a median of 15 needle lesions/patient, ablation abolished at least 1 inducible VT in 19 of 26 VT patients (73%), and suppressed ambient arrhythmia in 4 of 5 nonsustained arrhythmia patients. At the 6-month follow-up, 48% of patients were free of recurrent arrhythmia and another 19% were improved. Procedure-related complications included a single pericardial effusion treated with percutaneous drainage and a left ventricular pacing lead dislodgement with no deaths. CONCLUSIONS: In patients with recurrent ventricular arrhythmias refractory to medications and conventional catheter ablation, intramural needle radiofrequency ablation offers significant arrhythmia control with an acceptable procedural risk.


Asunto(s)
Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Taquicardia Ventricular , Ablación por Catéter/efectos adversos , Electrocardiografía/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Evaluación de Procesos y Resultados en Atención de Salud , Derrame Pericárdico/etiología , Derrame Pericárdico/terapia , Retratamiento/métodos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/terapia
17.
Heart Rhythm ; 16(7): 1021-1027, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30710740

RESUMEN

BACKGROUND: Catheter ablation for polymorphic ventricular tachycardia and ventricular fibrillation (PMVT/VF) may target triggering premature ventricular contractions (PVCs). Targeting ventricular scar has also been suggested, but data are limited. OBJECTIVE: The purpose of this study was to characterize the electrophysiological findings and ablation outcomes for patients with PMVT/VF and structural heart disease (SHD) compared to those with idiopathic VF. METHODS: Data from 32 consecutive patients (13 idiopathic VF, 19 SHD) with recurrent PMVT/VF who underwent catheter ablation were reviewed. RESULTS: A low-voltage area of myocardial scar was present in 15 of 19 patients with SHD. Sustained monomorphic ventricular tachycardia (SMVT) associated with scar was inducible and targeted in 8, 3 of whom had previous SMVT episodes separate from PMVT/VF episodes and 5 had no history of SMVT. Triggering PVCs were identified in 11 patients and arose from an area of endocardial scar in 6. Only scar ablation was performed in 8 patients who did not have triggering PVCs. All idiopathic VF patients underwent PVC ablation only. During a median of 540 days, 74% of SHD patients and 77% of idiopathic VF patients were free of recurrence, including 75% of those with only PVC ablation, 86% of those with scar plus PVC ablation, and 63% of those with only scar ablation. CONCLUSION: Patients with recurrent PMVT/VF and SHD often have a low-voltage scar associated with PVCs or inducible SMVT, which may also be the substrate for PMVT/VF. When present, substrate ablation targeting scar is a reasonable option for treatment of PMVT/VF even if PVCs are absent.


Asunto(s)
Cardiomiopatías/fisiopatología , Ablación por Catéter/métodos , Cicatriz/fisiopatología , Taquicardia Ventricular/cirugía , Fibrilación Ventricular/cirugía , Complejos Prematuros Ventriculares/cirugía , Cardiomiopatías/diagnóstico por imagen , Cicatriz/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/fisiopatología , Fibrilación Ventricular/diagnóstico por imagen , Fibrilación Ventricular/fisiopatología , Complejos Prematuros Ventriculares/diagnóstico por imagen , Complejos Prematuros Ventriculares/fisiopatología
18.
JACC Cardiovasc Imaging ; 12(7 Pt 1): 1177-1184, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30121262

RESUMEN

OBJECTIVES: The aim of this study was to assess the utility of left ventricular (LV) entropy, a novel measure of myocardial heterogeneity, for predicting cardiovascular events in patients with dilated cardiomyopathy (DCM). BACKGROUND: Current risk stratification for ventricular arrhythmia in patients with DCM is imprecise. LV entropy is a measure of myocardial heterogeneity derived from cardiac magnetic resonance imaging that assesses the probability distribution of pixel signal intensities in the LV myocardium. METHODS: A registry-based cohort of primary prevention implantable cardioverter-defibrillator patients with DCM had their LV entropy, late gadolinium enhancement (LGE) presence, and LGE mass measured on cardiac magnetic resonance imaging. Patients were followed from implantable cardioverter-defibrillator placement for arrhythmic events (appropriate implantable cardioverter-defibrillator therapy, ventricular arrhythmia, or sudden cardiac death), end-stage heart failure events (cardiac death, transplantation, or ventricular assist device placement), and all-cause mortality. RESULTS: One hundred thirty patients (mean age 55 years, 83% men, LV ejection fraction 29%, mean LV entropy 5.58 ± 0.72, LGE present in 57%) were followed for a median of 3.2 years. Eighteen (14.0%) experienced arrhythmic events, 17 (13.1%) experienced end-stage heart failure events, and 7 (5.4%) died. LV entropy provided substantial improvement of predictive ability when added to a model containing clinical variables and LGE mass (hazard ratio: 3.5; 95% confidence interval: 1.42 to 8.82; p = 0.007; net reclassification index = 0.345, p = 0.04). For end-stage heart failure events, LV entropy did not improve the model containing clinical variables and LGE mass (hazard ratio: 2.03; 95% confidence interval: 0.78 to 5.28; p = 0.14). Automated LV entropy measurement has excellent intraobserver (mean difference 0.04) and interobserver (mean difference 0.03) agreement. CONCLUSIONS: Automated LV entropy measurement is a novel marker for risk stratification toward ventricular arrhythmia in patients with DCM.


Asunto(s)
Arritmias Cardíacas/prevención & control , Cardiomiopatía Dilatada/terapia , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Imagen por Resonancia Cinemagnética , Prevención Primaria/instrumentación , Volumen Sistólico , Función Ventricular Izquierda , Adulto , Anciano , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidad , Arritmias Cardíacas/fisiopatología , Cardiomiopatía Dilatada/diagnóstico por imagen , Cardiomiopatía Dilatada/mortalidad , Cardiomiopatía Dilatada/fisiopatología , Muerte Súbita Cardíaca/prevención & control , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Sistema de Registros , Reproducibilidad de los Resultados , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
19.
Circ Arrhythm Electrophysiol ; 11(11): e006714, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30376734

RESUMEN

BACKGROUND: Percutaneous pericardial access for catheter ablation is associated with a bleeding risk. We sought to elucidate the relation of hemorrhagic and thromboembolic events associated with epicardial procedures to anticoagulation strategy. METHODS: Anticoagulation strategy before and during pericardial access for 355 patients (57±14 years old) who had ventricular arrhythmia mapping and ablation were reviewed. Oral anticoagulants were stopped perioperatively and heparin administered before the procedure. Pericardial bleeding >80 mL was considered significant. The patients were divided into 3 groups per the anticoagulation strategy. Group 1: no heparin was administered before pericardial access, group 2: heparin was administered and reversed before pericardial access, and group 3: heparin was administered and not reversed. RESULTS: Significant pericardial bleeding occurred in 46 cases (13%) and did not differ among the groups ( P=0.720). Unintentional cardiac puncture and left ventricular ejection fraction ≤35% were independently associated with pericardial bleeding (odds ratio, 16.4; 95% CI, 7.35-36.40; P<0.001 and odds ratio, 2.28; 95% CI, 1.02-5.10; P=0.044). Of 38 procedures with unintentional cardiac puncture, there was no difference in pericardial bleeding for different anticoagulation strategies. Thromboembolic events occurred in 5 patients; 1 coronary embolism, 1 stroke, 2 deep vein thrombosis with 1 fatal pulmonary embolism, and 1 thrombus on a temporary ventricular assist device. CONCLUSIONS: Bleeding is the major risk related to pericardial access and seems to be more related to unintentional cardiac puncture than to the anticoagulation strategy. Thrombotic complications are infrequent but potentially severe. The major focus for improving safety should be on the prevention of unintentional cardiac puncture.


Asunto(s)
Anticoagulantes/administración & dosificación , Ablación por Catéter/efectos adversos , Hemorragia/prevención & control , Complicaciones Posoperatorias/prevención & control , Taquicardia Ventricular/cirugía , Administración Oral , Anticoagulantes/efectos adversos , Mapeo Epicárdico/métodos , Femenino , Hemorragia/inducido químicamente , Humanos , Masculino , Persona de Mediana Edad , Pericardio/cirugía , Complicaciones Posoperatorias/inducido químicamente , Punciones/efectos adversos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...