Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-37561371

RESUMEN

The subclavian vein is typically used in cardiovascular implantable electronic device (CIED) implantations. External stress on the subclavian vein can lead to lead-related complications. There are several causes of this stress, such as frequent upper extremity movements or external injury. Venous thoracic outlet syndrome (TOS) can also become the cause of external lead stress. However, the diagnosis of venous TOS can be challenging because subclavian venography can appear normal at first glance. We present a unique case of a device infection in a patient with venous TOS. A careful observation of the imaging studies is vital for diagnosing venous TOS and a leadless pacemaker implantation could be an alternative therapeutic option.

2.
Int J Cardiovasc Imaging ; 37(10): 2839-2847, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34236570

RESUMEN

We aimed to evaluate the diagnostic agreement between radiofrequency (RF) intravascular ultrasound (IVUS) and optical coherence tomography (OCT) for thin-cap fibroatheroma (TCFA) in non-infarct-related coronary arteries (non-IRA) in patients with ST-segment elevation myocardial infarction (STEMI). In the Integrated Biomarker Imaging Study (IBIS-4), 103 STEMI patients underwent OCT and RF-IVUS imaging of non-IRA after successful primary percutaneous coronary intervention and at 13-month follow-up. A coronary lesion was defined as a segment with ≥ 3 consecutive frames (≈1.2 mm) with plaque burden ≥ 40% as assessed by grayscale IVUS. RF-IVUS-derived TCFA was defined as a lesion with > 10% confluent necrotic core abutting to the lumen in > 10% of the circumference. OCT-TCFA was defined by a minimum cap thickness < 65 µm. The two modalities were matched based on anatomical landmarks using a dedicated matching software. Using grayscale IVUS, we identified 276 lesions at baseline (N = 146) and follow-up (N = 130). Using RF-IVUS, 208 lesions (75.4%) were classified as TCFA. Among them, OCT identified 14 (6.7%) TCFA, 60 (28.8%) thick-cap fibroatheroma (ThCFA), and 134 (64.4%) non-fibroatheroma. All OCT-TCFA (n = 14) were confirmed as RF-TCFA. The concordance rate between RF-IVUS and OCT for TCFA diagnosis was 29.7%. The reasons for discordance were: OCT-ThCFA (25.8%); OCT-fibrous plaque (34.0%); attenuation due to calcium (23.2%); attenuation due to macrophage (10.3%); no significant attenuation (6.7%). There was a notable discordance in the diagnostic assessment of TCFA between RF-IVUS and OCT. The majority of RF-derived TCFA were not categorized as fibroatheroma using OCT, while all OCT-TCFA were classified as TCFA by RF-IVUS.ClinicalTrials.gov Identifier NCT00962416.


Asunto(s)
Enfermedad de la Arteria Coronaria , Infarto del Miocardio , Placa Aterosclerótica , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Humanos , Valor Predictivo de las Pruebas , Tomografía de Coherencia Óptica , Ultrasonografía Intervencional
3.
Eur Heart J Cardiovasc Imaging ; 22(9): 1054-1062, 2021 08 14.
Artículo en Inglés | MEDLINE | ID: mdl-32929461

RESUMEN

AIMS: Arterial remodelling is an important determinant of coronary atherosclerosis. Assessment of the remodelling index, comparing a lesion to a local reference site, is a suboptimal correlate of serial vascular changes. We assessed a novel approach which, unlike the local-reference approach, uses the entire artery's global remodelling as reference. METHODS AND RESULTS: Serial (baseline and 13 months) intravascular ultrasound was performed in 146 non-infarct-related arteries of 82 patients treated with high-intensity statin. Arteries were divided into 3-mm segments (n = 1479), and focal remodelling was characterized in individual segments at both timepoints applying the global arterial reference approach. First, we compared preceding vascular changes in relation to follow-up remodelling. Second, we examined whether baseline remodelling predicts subsequent plaque progression/regression. At follow-up, segments with constrictive vs. compensatory or expansive remodelling had greater preceding reduction of vessel area (-0.67 vs. -0.38 vs. -0.002 mm2; P < 0.001) and lumen area (-0.82 vs. -0.09 vs. 0.40 mm2; P < 0.001). Overall, we found significant regression in percent atheroma volume (PAV) [-0.80% (-1.41 to -0.19)]. Segments with constrictive remodelling at baseline had greater subsequent PAV regression vs. modest regression in the compensatory, and PAV progression in the expansive remodelling group (-6.14% vs. -0.71% vs. 2.26%; P < 0.001). Lesion-level analyses (n = 118) showed no differences when remodelling was defined by the local reference approach at baseline or follow-up. CONCLUSION: Remodelling assessment using a global arterial reference approach, but not the commonly used, local reference site approach, correlated reasonably well with serial changes in arterial dimensions and identified arterial segments with subsequent PAV progression despite intensive statin treatment and overall atheroma regression.


Asunto(s)
Enfermedad de la Arteria Coronaria , Placa Aterosclerótica , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Progresión de la Enfermedad , Humanos , Placa Aterosclerótica/diagnóstico por imagen , Placa Aterosclerótica/tratamiento farmacológico , Ultrasonografía , Ultrasonografía Intervencional
4.
JACC Cardiovasc Imaging ; 13(4): 1021-1032, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31202749

RESUMEN

OBJECTIVES: This study sought to examine the utility of multimodality intravascular imaging and of the endothelial shear stress (ESS) distribution to predict atherosclerotic evolution. BACKGROUND: There is robust evidence that intravascular ultrasound (IVUS)-derived plaque characteristics and ESS distribution can predict, with however limited accuracy, atherosclerotic evolution; nevertheless, it is yet unclear whether multimodality imaging and ESS mapping enable more accurate prediction of coronary plaque progression. METHODS: A total of 44 patients admitted with a myocardial infarction that had successful revascularization and 3-vessel IVUS and optical coherence tomography (OCT) imaging at baseline and 13-month follow-up were included in the study. The IVUS data acquired at baseline in the nonculprit vessels were fused with x-ray angiography to reconstruct coronary anatomy and in the obtained models blood flow simulation was performed and the ESS was estimated. The baseline plaque characteristics and ESS distribution were used to identify predictors of disease progression: defined as a lumen reduction and an increase in plaque burden at follow-up. RESULTS: Seventy-three vessels were included in the final analysis. Baseline ESS and the IVUS-derived but not the OCT-derived plaque characteristics were independently associated with a decrease in lumen area and an increase in plaque burden. Low ESS (odds ratio: 0.45; 95% confidence interval: 0.28 to 0.71; p < 0.001) and plaque burden (odds ratio: 0.73; 95% confidence interval: 0.54 to 0.97; p = 0.030) were the only independent predictors of disease progression at follow-up. The accuracy of the IVUS-derived plaque characteristics in predicting disease progression did not improve when ESS (AUC: 0.824 vs. 0.847; p = 0.127) or when OCT variables and ESS (AUC: 0.842; p = 0.611) were added into the model. CONCLUSIONS: ESS and OCT-derived variables did not improve the efficacy of IVUS in predicting disease progression. Further research is required to investigate whether multimodality imaging combined with ESS mapping will allow more reliable vulnerable plaque detection. (Comparison of Biomatrix Versus Gazelle in ST-Elevation Myocardial Infarction [STEMI] [COMFORTABLE]; NCT00962416).


Asunto(s)
Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Circulación Coronaria , Vasos Coronarios/diagnóstico por imagen , Hemodinámica , Imagen Multimodal , Placa Aterosclerótica , Tomografía de Coherencia Óptica , Ultrasonografía Intervencional , Anciano , Enfermedad de la Arteria Coronaria/fisiopatología , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/fisiopatología , Progresión de la Enfermedad , Femenino , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Factores de Tiempo
5.
Clin Chim Acta ; 500: 20-27, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31606399

RESUMEN

BACKGROUND: Although we previously reported the fasting 13C-glucose breath test (FGBT) was useful for the diagnosis of hepatic insulin resistance (IR), there has been no report in an actual clinical setting. We therefore performed the FGBT in patients with heart disease to assess the difference in the diagnostic ability of HIR between the FGBT and HOMA-IR; we also assessed the relationship between the FGBT and known cardiovascular risk factors. METHODS: Two hundred patients (100 with ischemic heart disease [IHD], 50 with non-ischemic heart disease [NIHD], and 50 with non-cardiac lifestyle-related disease [NCD]) participated in this study. The data of 40 healthy volunteers [HV] was obtained in our previous study. We evaluated the 13C excretion rate at 120 min (C120) as the indicator of hepatic IR in the FGBT. RESULTS: The value of C120 in each disease group was significantly lower than in HV, but the HOMA-IR in the IHD and NCD groups was not significantly different from that in HV. The value of C120 significantly correlated with known cardiovascular risk factors. CONCLUSIONS: These results indicated the FGBT is more sensitive than HOMA-IR for evaluating hepatic IR as a cardiovascular risk factor and is likely useful for managing patients to prevent cardiovascular disease.


Asunto(s)
Pruebas Respiratorias/métodos , Enfermedades Cardiovasculares/diagnóstico , Ayuno , Glucosa/análisis , Resistencia a la Insulina , Hígado/metabolismo , Relación Señal-Ruido , Anciano , Isótopos de Carbono/química , Enfermedades Cardiovasculares/metabolismo , Femenino , Glucosa/química , Glucosa/metabolismo , Humanos , Masculino , Factores de Riesgo
6.
J Cardiol ; 74(5): 412-417, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31272834

RESUMEN

BACKGROUND: Although standard treatment for heart failure (HF) has been established, it remains difficult to relieve HF-associated symptoms in some patients. Kampo medicines have been used to treat various diseases; however, it remains unclear whether they are effective in HF patients. We therefore performed a prospective, randomized, controlled trial to investigate whether Mokuboito, a Kampo medicine, affected symptoms and other parameters in hospitalized patients with acute decompensated HF (ADHF), as compared to standard therapy alone. METHODS: Forty patients were allocated randomly to Group S (standard therapy alone) or Group M (oral administration of Mokuboito plus standard therapy). The primary outcome was changes in global clinical status based on a visual analog scale (VAS) from baseline at day 10 or discharge if earlier. RESULTS: The decrease in VAS score was significantly greater in Group M than Group S (p=0.001). Although there were no differences between the groups in changes in the secondary endpoints of body weight, peripheral edema, biochemical and echocardiographic parameters, left ventricular end-diastolic diameter, and serum total bilirubin levels were significantly reduced in Group M (p=0.038; 0.002, respectively) but not in Group S, implying that Mokuboito might attenuate organ congestion and cardiac preload. CONCLUSIONS: Oral administration of Mokuboito significantly improved ADHF-related symptoms. Our observations might provide the basis for a novel therapeutic strategy in hospitalized patients with ADHF.


Asunto(s)
Insuficiencia Cardíaca/tratamiento farmacológico , Medicina Kampo/métodos , Extractos Vegetales/uso terapéutico , Enfermedad Aguda , Anciano , Femenino , Insuficiencia Cardíaca/fisiopatología , Humanos , Japón , Masculino , Persona de Mediana Edad , Alta del Paciente , Proyectos Piloto , Estudios Prospectivos , Resultado del Tratamiento
7.
Eur Heart J ; 40(24): 1909-1919, 2019 06 21.
Artículo en Inglés | MEDLINE | ID: mdl-30851032

RESUMEN

AIMS: The long-term outcomes of biolimus-eluting stents (BESs) with biodegradable polymer as compared with bare-metal stent (BMS) in patients with ST-segment elevation myocardial infarction (STEMI) remain unknown. METHODS AND RESULTS: We performed a 5-year clinical follow-up of 1157 patients (BES: N = 575 and BMS: N = 582) included in the randomized COMFORTABLE AMI trial. Serial intracoronary imaging of stented segments using both intravascular ultrasound (IVUS) and optical coherence tomography performed at baseline and 13 months follow-up were analysed in 103 patients. At 5 years, BES reduced the risk of major adverse cardiac events [MACE; hazard ratio (HR) 0.56, 95% confidence interval (CI): 0.39-0.79, P = 0.001], driven by lower risks for target vessel-related reinfarction (HR 0.44, 95% CI: 0.22-0.87, P = 0.02) and ischaemia-driven target lesion revascularization (HR 0.41, 95% CI: 0.25-0.66, P < 0.001). Definite stent thrombosis (ST) was recorded in 2.2% and 3.9% (HR 0.57, 95% CI: 0.28-1.16, P = 0.12) with no differences in rates of very late definite ST (1.3% vs. 1.6%, P = 0.77). Optical coherence tomography showed no difference in the frequency of malapposed stent struts at follow-up (BES 0.08% vs. BMS 0.02%, P = 0.10). Uncovered stent struts were rarely observed but more frequent in BES (2.1% vs. 0.15%, P < 0.001). In the IVUS analysis, there was no positive remodelling in either group (external elastic membrane area change BES: -0.63 mm2, 95% CI: -1.44 to 0.39 vs. BMS -1.11 mm2, 95% CI: -2.27 to 0.04, P = 0.07). CONCLUSION: Compared with BMS, the implantation of biodegradable polymer-coated BES resulted in a lower 5-year rate of MACE in patients with STEMI undergoing primary percutaneous coronary intervention. At 13 months, vascular healing in treated culprit lesions was almost complete irrespective of stent type. CLINICAL TRIAL REGISTRATION: http://www.clinicaltrials.gov. Unique identifier: NCT00962416.


Asunto(s)
Stents Liberadores de Fármacos/efectos adversos , Infarto del Miocardio con Elevación del ST/cirugía , Stents/efectos adversos , Implantes Absorbibles , Enfermedad Aguda , Reestenosis Coronaria/epidemiología , Reestenosis Coronaria/etiología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Metales , Intervención Coronaria Percutánea/métodos , Polímeros , Diseño de Prótesis , Infarto del Miocardio con Elevación del ST/fisiopatología , Sirolimus/análogos & derivados , Stents/tendencias , Trombosis/epidemiología , Trombosis/etiología , Tomografía de Coherencia Óptica/métodos , Resultado del Tratamiento , Ultrasonografía Intervencional/métodos
8.
Heart ; 105(14): 1078-1086, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30877239

RESUMEN

AIM: To examine the effect of endothelial shear stress (ESS) on the dynamic changes in plaque phenotype. METHODS: Patients with myocardial infarction that had intravascular ultrasound-virtual histology (IVUS-VH) and optical coherence tomography (OCT) at baseline and 13-month follow-up were studied. The IVUS-VH data were used to reconstruct the nonculprit vessels, and in the obtained models the ESS was estimated in 3 mm segments. Plaque morphology was derived in each segment from IVUS-VH and OCT. Disease progression was defined as the presence of ≥2 out of the following criteria: reduction in lumen area, increase in plaque burden and change of plaque morphology to a more vulnerable phenotype. Linear mixed effects models were used to assess the effect of ESS in different phenotypes. RESULTS: Sixty-eight vessels were included in the analysis. Low ESS was associated with plaque progression in all phenotypes. The effect of ESS on plaque burden (p for interaction=0.467) and phenotype (p for interaction=0.188) was similar in all plaque types, whereas the effect of ESS on the changes in lumen dimensions was more prominent in disease-free (ß=0.70, p<0.001) than fibrotic/fibrocalcific (ß=0.28, p<0.001) or lipid-rich plaques (ß=0.15, p=0.015). Standalone IVUS-VH misclassified plaque morphology in one-third of the cases leading to erroneous estimations about the effect of ESS on plaque evolution in different phenotypes. CONCLUSIONS: The effect of ESS on plaque progression is similar in all phenotypes and cannot be accurately assessed by standalone IVUS-VH which often misclassifies plaque morphology. Therefore, multimodality imaging should be considered to examine the implications of ESS on plaque evolution. CLINICAL TRIAL REGISTRATION: NCT00962416; Post-results.


Asunto(s)
Vasos Coronarios , Endotelio Vascular , Infarto del Miocardio , Placa Aterosclerótica , Flujo Sanguíneo Regional , Tomografía de Coherencia Óptica/métodos , Ultrasonografía Intervencional/métodos , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/fisiopatología , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/fisiopatología , Precisión de la Medición Dimensional , Progresión de la Enfermedad , Endotelio Vascular/patología , Endotelio Vascular/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Imagen Multimodal , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/etiología , Infarto del Miocardio/cirugía , Intervención Coronaria Percutánea/instrumentación , Intervención Coronaria Percutánea/métodos , Placa Aterosclerótica/complicaciones , Placa Aterosclerótica/diagnóstico por imagen , Placa Aterosclerótica/fisiopatología , Resistencia al Corte/fisiología
9.
JACC Cardiovasc Imaging ; 12(8 Pt 1): 1518-1528, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-30553686

RESUMEN

OBJECTIVES: This study assessed changes in optical coherence tomography (OCT)-defined plaque composition in patients with ST-elevation myocardial infarction (STEMI) receiving high-intensity statin treatment. BACKGROUND: OCT is a high-resolution modality capable of measuring plaque characteristics including fibrous cap thickness (FCT) and macrophage infiltration. There is limited in vivo evidence regarding the effects of statins on OCT-defined coronary atheroma composition and no evidence in the context of STEMI. METHODS: In the IBIS-4 (Integrated Biomarker Imaging Study-4), 103 patients underwent intravascular ultrasonography and OCT of 2 noninfarct-related coronary arteries in the acute phase of STEMI. Patients were treated with high-dose rosuvastatin for 13 months. Serial OCT imaging was available in 153 arteries from 83 patients. We measured FCT by using a semi-automated method. Co-primary endpoints consisted of the change in minimum FCT (measured in fibroatheromas) and change in macrophage line arc. RESULTS: At 13 months, median low-density lipoprotein cholesterol had decreased from 128 mg/dl to 73.6 mg/dl. Minimum FCT, measured in 31 lesions from 27 patients, increased from 64.9 ± 19.9 µm to 87.9 ± 38.1 µm (p = 0.008). Macrophage line arc decreased from 9.6° ± 12.8° to 6.4° ± 9.6° (p < 0.0001). The secondary endpoint, mean lipid arc, decreased from 55.9° ± 37° to 43.5° ± 33.5°. In lesion-level analyses (n = 191), 9 of 13 thin-cap fibroatheromata (TCFAs) at baseline (69.2%) regressed to non-TCFA morphology, whereas 2 of 178 non-TCFA lesions (1.1%) progressed to TCFAs. CONCLUSIONS: In this observational study, we found significant increase in minimum FCT, reduction in macrophage accumulation, and frequent regression of TCFAs to other plaque phenotypes in nonculprit lesions of patients with STEMI treated with high-intensity statin therapy.


Asunto(s)
Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Vasos Coronarios/efectos de los fármacos , Inhibidores de Hidroximetilglutaril-CoA Reductasas/administración & dosificación , Placa Aterosclerótica , Rosuvastatina Cálcica/administración & dosificación , Infarto del Miocardio con Elevación del ST/tratamiento farmacológico , Tomografía de Coherencia Óptica , Anciano , Biomarcadores/sangre , LDL-Colesterol/sangre , Enfermedad de la Arteria Coronaria/sangre , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/patología , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/metabolismo , Vasos Coronarios/patología , Femenino , Fibrosis , Humanos , Inhibidores de Hidroximetilglutaril-CoA Reductasas/efectos adversos , Macrófagos/efectos de los fármacos , Macrófagos/patología , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/instrumentación , Valor Predictivo de las Pruebas , Estudios Prospectivos , Rosuvastatina Cálcica/efectos adversos , Infarto del Miocardio con Elevación del ST/sangre , Infarto del Miocardio con Elevación del ST/diagnóstico por imagen , Infarto del Miocardio con Elevación del ST/patología , Stents , Factores de Tiempo , Resultado del Tratamiento
10.
Am J Cardiol ; 119(4): 501-507, 2017 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-27923461

RESUMEN

Long-term clinical outcomes of new-generation drug-eluting stents in complex anatomic and clinical settings are not well defined. This study assessed the impact of patient and lesion complexity on 2-year outcomes after coronary revascularization with ultrathin strut biodegradable-polymer (BP) sirolimus-eluting stents (SES) versus durable-polymer (DP) everolimus-eluting stents (EES). In a prespecified analysis of the BIOSCIENCE randomized trial (NCT01443104), complex patients (911 of 2,119; 43%) were defined by the presence of acute ST-elevation myocardial infarction (MI); left ventricular ejection fraction ≤30%; renal dysfunction; insulin-treated diabetes; treatment of ostial lesion, bypass graft, unprotected left main lesion; or 3-vessel intervention. The primary end point was target lesion failure (TLF), a composite of cardiac death, target vessel MI, and clinically indicated target lesion revascularization. At 2 years, complex compared with simple patients had a greater risk of TLF (14.5% vs 7.4%, risk ratio 2.05, 95% confidence interval 1.56 to 2.69; p <0.001). The difference was sustained beyond 1 year on landmark analysis. Complex patients had higher rates of the patient-oriented composite end point of death, any MI, or any revascularization (23% vs 14.4%; p <0.001) as well as definite stent thrombosis (1.6% vs 0.4%, p = 0.006). There were no differences in TLF and patient-oriented composite end point between the BP-SES versus DP-EES, consistently among simple and complex patients. In conclusion, patient and lesion complexity had a durable adverse impact on clinical outcomes throughout 2 years of follow-up in this all-comers randomized trial. Safety and efficacy of new-generation BP-SES and DP-EES were comparable, irrespective of complexity status.


Asunto(s)
Implantes Absorbibles , Enfermedad de la Arteria Coronaria/cirugía , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Polímeros , Infarto del Miocardio con Elevación del ST/cirugía , Anciano , Antibióticos Antineoplásicos/administración & dosificación , Comorbilidad , Enfermedad de la Arteria Coronaria/epidemiología , Enfermedad de la Arteria Coronaria/fisiopatología , Diabetes Mellitus/tratamiento farmacológico , Diabetes Mellitus/epidemiología , Femenino , Estudios de Seguimiento , Humanos , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Prospectivos , Diseño de Prótesis , Ensayos Clínicos Controlados Aleatorios como Asunto , Insuficiencia Renal Crónica/epidemiología , Infarto del Miocardio con Elevación del ST/epidemiología , Infarto del Miocardio con Elevación del ST/fisiopatología , Índice de Severidad de la Enfermedad , Sirolimus/administración & dosificación , Volumen Sistólico , Resultado del Tratamiento , Disfunción Ventricular Izquierda/epidemiología , Disfunción Ventricular Izquierda/fisiopatología
11.
EuroIntervention ; 12(8): e987-e997, 2016 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-27721214

RESUMEN

AIMS: The minimum fibrous cap thickness (FCT) is considered a major criterion of coronary plaque vulnerability according to autopsy studies. We aimed to assess the reproducibility in the measurement of the optical coherence tomography (OCT)-detected minimum FCT and the agreement in the classification of thin-cap fibroatheroma (TCFA), by a software-based semi-automatic method compared with the manual method. METHODS AND RESULTS: A total of 50 frames with fibroatheromas (FA) were randomly selected from the Integrated Biomarker Imaging Study-4 (IBIS-4). Two experienced OCT analysts independently measured the minimum FCT at two different time points, manually and by three different semi-automatic software-based algorithms, based on the assessment of light intensity along the axial scan line. A TCFA was defined as an FA with minimum FCT <65 µm. The inter- and intra-observer reproducibility of the manual measurement of the minimum FCT was moderate with an intra-class correlation coefficient (ICC) of 0.71 and 0.79, respectively. The corresponding ICCs by either one of the three semi-automatic algorithms were 0.99. When categorising FA according to the minimum FCT based on the manual assessment, the inter- and intra-observer agreement was poor (κ=0.23) and moderate (κ=0.50), respectively. In contrast, the semi-automatic assessment showed perfect agreement for both inter- and intra-observer assessments (κ=0.90-1.00 and 1.00, respectively). CONCLUSIONS: While semi-automatic assessment of FCT and TCFA classification was associated with excellent reproducibility and agreement, manual measurements were associated with a moderate reproducibility and agreement in the quantification of FCT and classification of TCFA.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Placa Aterosclerótica/diagnóstico por imagen , Humanos , Variaciones Dependientes del Observador , Estudios Prospectivos , Reproducibilidad de los Resultados , Tomografía de Coherencia Óptica
12.
EuroIntervention ; 12(5): e595-604, 2016 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-27497359

RESUMEN

AIMS: We sought to assess the performance of drug-eluting stents combining an ultrathin cobalt-chromium platform with a biodegradable polymer across categories of increasing SYNTAX score (SS). METHODS AND RESULTS: Patients included in the BIOSCIENCE trial and randomly allocated to treatment with biodegradable polymer sirolimus-eluting stents (BP-SES) or durable polymer everolimus-eluting stents (DP-EES) were categorised according to SS tertiles (low <8, medium 8-15, high >15). The primary endpoint, target lesion failure (TLF), was defined as a composite of cardiac death, target vessel myocardial infarction and clinically indicated target lesion revascularisation. The patient-oriented endpoint (POCE) included death, myocardial infarction, or any repeat revascularisation. The SS was available in 2,041 out of 2,119 patients (96.3%). At two-year follow-up, patients with an SS >15 experienced higher rates of both TLF and POCE as compared to patients with medium and low SS (14.5% vs. 8.1% and vs. 5.9%, p<0.001; 22.7% vs. 14.9% and vs. 12.4%; p<0.001), respectively. Comparable rates of the composite endpoints were documented for both stent types in each category of SS. CONCLUSIONS: Increasing lesion complexity as assessed by SS was associated with higher rates of TLF and POCE in a contemporary PCI population with minimal exclusion criteria. BP-SES and DP-EES showed comparable performance across the entire spectrum of CAD severity.


Asunto(s)
Implantes Absorbibles , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Everolimus/uso terapéutico , Infarto del Miocardio/terapia , Sirolimus/uso terapéutico , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/métodos , Sirolimus/administración & dosificación , Resultado del Tratamiento
13.
Atherosclerosis ; 247: 154-60, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26921743

RESUMEN

OBJECTIVES: Levels of inflammatory biomarkers associate with changes of coronary atheroma burden in statin-treated patients with stable coronary artery disease. This study sought to determine changes of plaque composition in vivo in relation to high-sensitivity C-reactive protein (hs-CRP) levels in patients with ST-elevation myocardial infarction (STEMI) receiving high-intensity statin therapy. METHODS: The IBIS-4 study performed serial (baseline and 13-month), 2-vessel intravascular ultrasound (IVUS) and radiofrequency-IVUS of the non-infarct-related arteries in patients with STEMI treated with high-intensity statin therapy. The present analysis included 44 patients (80 arteries) with serial measurements of hs-CRP. RESULTS: At follow-up, median low-density lipoprotein cholesterol (LDL-C) levels decreased from 126 to 77 mg/dl, HDL-C increased from 44 to 47 mg/dl, and hs-CRP decreased from 1.6 to 0.7 mg/L. Regression of percent atheroma volume (-0.99%, 95% CI -1.84 to -0.14, p = 0.024) was accompanied by reduction of percent fibro-fatty (p = 0.04) and fibrous tissue (p < 0.001), and increase in percent necrotic core (p = 0.006) and dense calcium (p < 0.001). Follow-up levels of hs-CRP, but not LDL-C, correlated with changes in percent necrotic core (p = 0.001) and inversely with percent fibrous tissue volume (p = 0.008). Similarly, baseline-to-follow-up change of hs-CRP correlated with the change in percent necrotic core volume (p = 0.02). CONCLUSIONS: In STEMI patients receiving high-intensity statin therapy, stabilization of VH-IVUS-defined necrotic core was confined to patients with lowest on-treatment levels and greatest reduction of hs-CRP. Elevated CRP levels at follow-up may identify progression of high-risk coronary plaque composition despite intensive statin therapy and overall regression of atheroma volume.


Asunto(s)
Antiinflamatorios/uso terapéutico , Proteína C-Reactiva/metabolismo , Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Vasos Coronarios/efectos de los fármacos , Inhibidores de Hidroximetilglutaril-CoA Reductasas/uso terapéutico , Mediadores de Inflamación/sangre , Infarto del Miocardio/tratamiento farmacológico , Placa Aterosclerótica , Anciano , Biomarcadores/sangre , HDL-Colesterol/sangre , LDL-Colesterol/sangre , Enfermedad de la Arteria Coronaria/sangre , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Femenino , Fibrosis , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/sangre , Infarto del Miocardio/diagnóstico por imagen , Necrosis , Estudios Prospectivos , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía Intervencional
14.
Circulation ; 133(7): 650-60, 2016 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-26762519

RESUMEN

BACKGROUND: The pathomechanisms underlying very late stent thrombosis (VLST) after implantation of drug-eluting stents (DES) are incompletely understood. Using optical coherence tomography, we investigated potential causes of this adverse event. METHODS AND RESULTS: Between August 2010 and December 2014, 64 patients were investigated at the time point of VLST as part of an international optical coherence tomography registry. Optical coherence tomography pullbacks were performed after restoration of flow and analyzed at 0.4 mm. A total of 38 early- and 20 newer-generation drug-eluting stents were suitable for analysis. VLST occurred at a median of 4.7 years (interquartile range, 3.1-7.5 years). An underlying putative cause by optical coherence tomography was identified in 98% of cases. The most frequent findings were strut malapposition (34.5%), neoatherosclerosis (27.6%), uncovered struts (12.1%), and stent underexpansion (6.9%). Uncovered and malapposed struts were more frequent in thrombosed compared with nonthrombosed regions (ratio of percentages, 8.26; 95% confidence interval, 6.82-10.04; P<0.001 and 13.03; 95% confidence interval, 10.13-16.93; P<0.001, respectively). The maximal length of malapposed or uncovered struts (3.40 mm; 95% confidence interval, 2.55-4.25; versus 1.29 mm; 95% confidence interval, 0.81-1.77; P<0.001), but not the maximal or average axial malapposition distance, was greater in thrombosed compared with nonthrombosed segments. The associations of both uncovered and malapposed struts with thrombus were consistent among early- and newer-generation drug-eluting stents. CONCLUSIONS: The leading associated findings in VLST patients in descending order were malapposition, neoatherosclerosis, uncovered struts, and stent underexpansion without differences between patients treated with early- and new-generation drug-eluting stents. The longitudinal extension of malapposed and uncovered stent was the most important correlate of thrombus formation in VLST.


Asunto(s)
Vasos Coronarios/patología , Stents Liberadores de Fármacos/efectos adversos , Stents Liberadores de Fármacos/tendencias , Trombosis/diagnóstico , Trombosis/etiología , Tomografía de Coherencia Óptica/métodos , Anciano , Vasos Coronarios/cirugía , Estudios Transversales , Stents Liberadores de Fármacos/normas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Falla de Prótesis , Factores de Tiempo
15.
JACC Cardiovasc Imaging ; 9(2): 163-72, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26777223

RESUMEN

OBJECTIVES: This study sought to evaluate the diagnostic performance of optical frequency domain imaging (OFDI) for recognition of coronary plaque morphologies and to assess additive values of integrated backscatter intravascular ultrasound (IB-IVUS) in detection of vulnerable plaque. BACKGROUND: Precise diagnosis of coronary lesions susceptible to plaque rupture and thrombosis may serve to stratify the risk of future coronary events and to make decisions for appropriate treatment of choice. METHODS: Twenty-seven coronary arteries from 14 human autopsy hearts were interrogated ex vivo by OFDI and IB-IVUS. Imaged segments were sectioned at 3 mm intervals where a total of 360 pairs of cross-sectional images coregistered to histology were investigated. RESULTS: Overall, OFDI could depict various plaque components and structures such as fibrous tissue, sheet and nodular calcification, lipid, cholesterol crystals, and healed plaque rupture. OFDI could detect 14 of 18 thin-cap fibroatheroma (TCFA), however, the diagnostic accuracy was not high (positive predictive value [PPV] = 60.9%, κ = 0.664; area under the curve [AUC]: 0.88) mainly because of signal interference from macrophages. Further, we defined IB-IVUS-derived TCFA by recursive partitioning analysis as: 1) cross-sectional % lipid area >65.1%; 2) % lipid area >32.3 but <65.1% with plaque area >10.5 mm(2), where TCFA detection by IB-IVUS alone was marginal (PPV = 50.0%, κ = 0.545; AUC: 0.82). However, when IB-IVUS was combined with OFDI, all pseudo OFDI-derived TCFA (non-TCFA on histology) were excluded. Accordingly, PPV of TCFAs diagnosed by both OFDI and IB-IVUS was improved to 100.0% (κ = 0.704; AUC: 0.93). CONCLUSIONS: OFDI could recognize detailed morphologies of human coronary plaque. However, diagnostic accuracy of both OFDI alone and IB-IVUS alone to identify TCFA is limited. Combination of IB-IVUS with OFDI improved the accuracy for TCFA detection, suggesting hybrid imaging or further development of novel devices will be required to identify coronary lesions responsible for future events.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología , Imagen Óptica/métodos , Placa Aterosclerótica , Ultrasonografía Intervencional , Adulto , Área Bajo la Curva , Autopsia , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/patología , Trombosis Coronaria/diagnóstico , Trombosis Coronaria/etiología , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Pronóstico , Curva ROC , Reproducibilidad de los Resultados , Rotura Espontánea , Dispersión de Radiación
16.
EuroIntervention ; 12(11): e1343-e1354, 2016 Dec 10.
Artículo en Inglés | MEDLINE | ID: mdl-26690319

RESUMEN

AIMS: Our aim was to compare the safety and efficacy of a novel, ultrathin strut, biodegradable polymer sirolimus-eluting stent (BP-SES) with a thin strut, durable polymer everolimus-eluting stent (DP-EES) in a pre-specified subgroup of patients with acute ST-segment elevation myocardial infarction (STEMI) enrolled in the BIOSCIENCE trial. METHODS AND RESULTS: The BIOSCIENCE trial is an investigator-initiated, single-blind, multicentre, randomised non-inferiority trial (NCT01443104). Randomisation was stratified according to the presence or absence of STEMI. The primary endpoint, target lesion failure (TLF), is a composite of cardiac death, target vessel myocardial infarction, and clinically indicated target lesion revascularisation within 12 months. Between February 2012 and May 2013, 407 STEMI patients were randomly assigned to treatment with BP-SES or DP-EES. At one year, TLF occurred in seven (3.4%) patients treated with BP-SES and 17 (8.8%) patients treated with DP-EES (RR 0.38, 95% CI: 0.16-0.91, p=0.024). Rates of cardiac death were 1.5% in the BP-SES group and 4.7% in the DP-EES group (RR 0.31, 95% CI: 0.08-1.14, p=0.062); rates of target vessel myocardial infarction were 0.5% and 2.6% (RR 0.18, 95% CI: 0.02-1.57, p=0.082), respectively, and rates of clinically indicated target lesion revascularisation were 1.5% in the BP-SES group versus 2.1% in the DP-EES group (RR 0.69, 95% CI: 0.16-3.10, p=0.631). There was no difference in the risk of definite stent thrombosis. CONCLUSIONS: In this pre-specified subgroup analysis, BP-SES was associated with a lower rate of target lesion failure at one year compared to DP-EES in STEMI patients. These findings require confirmation in a dedicated STEMI trial.


Asunto(s)
Stents Liberadores de Fármacos , Everolimus/uso terapéutico , Infarto del Miocardio/terapia , Intervención Coronaria Percutánea , Sirolimus/uso terapéutico , Anciano , Fármacos Cardiovasculares/uso terapéutico , Trombosis Coronaria/etiología , Trombosis Coronaria/terapia , Femenino , Humanos , Masculino , Persona de Mediana Edad , Método Simple Ciego , Resultado del Tratamiento
17.
J Am Coll Cardiol ; 66(17): 1901-14, 2015 Oct 27.
Artículo en Inglés | MEDLINE | ID: mdl-26493663

RESUMEN

BACKGROUND: Bioresorbable scaffolds provide transient lumen support followed by complete resorption. OBJECTIVES: This study examined whether very late scaffold thrombosis (VLScT) occurs when resorption is presumed to be nearly complete. METHODS: Patients with VLScT at 3 tertiary care centers underwent thrombus aspiration followed by optical coherence tomography (OCT). Thrombus aspirates were analyzed by histopathological and spectroscopic examination. RESULTS: Between March 2014 and February 2015, 4 patients presented with VLScT at 44 (case 1), 19 (cases 2 and 4), and 21 (case 3) months, respectively, after implantation of an Absorb Bioresorbable Vascular Scaffold 1.1 (Abbott Laboratories, Abbott Park, Illinois). At the time of VLScT, all patients were taking low-dose aspirin, and 2 patients were also taking prasugrel. OCT showed malapposed scaffold struts surrounded by thrombus in 7.1%, 9.0%, and 8.9% of struts in cases 1, 2, and 4, respectively. Scaffold discontinuity with struts in the lumen center was the cause of malapposition in cases 2 and 4. Uncovered scaffold struts with superimposed thrombus were the predominant findings in case 3. OCT percent area stenosis at the time of VLScT was high in case 1 (74.8%) and case 2 (70.9%) without evidence of excessive neointimal hyperplasia. Spectroscopic thrombus aspirate analysis showed persistence of intracoronary polymer fragments in case 1. CONCLUSIONS: VLScT may occur at advanced stages of scaffold resorption. Potential mechanisms specific for VLScT include scaffold discontinuity and restenosis during the resorption process, which appear delayed in humans; these findings suggest an extended period of vulnerability for thrombotic events.


Asunto(s)
Trombosis/etiología , Andamios del Tejido , Anciano , Enfermedad de la Arteria Coronaria/terapia , Femenino , Humanos , Masculino , Persona de Mediana Edad , Trombosis/diagnóstico , Factores de Tiempo , Andamios del Tejido/efectos adversos , Tomografía de Coherencia Óptica
18.
Eur Heart J ; 36(32): 2167-76, 2015 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-26040806

RESUMEN

AIMS: The purpose of the present study was to investigate the relationship between in-stent neoatherosclerosis (NA) and native atherosclerosis progression of untreated coronary segments. METHODS AND RESULTS: In-stent NA was assessed by optical coherence tomography (OCT) among patients included in the SIRTAX-LATE OCT study 5 years after drug-eluting stent (DES) (sirolimus-eluting and paclitaxel-eluting stents) implantation. Neoatherosclerosis was defined as the presence of fibroatheroma or fibrocalcific plaque within the neointima of stented segments with a longitudinal extension >1.0 mm. Atherosclerosis progression in untreated native coronary segments was evaluated by serial quantitative coronary angiography (QCA). The change in minimal lumen diameter (MLD) was serially assessed within matched segments at baseline and 5-year angiographic follow-up. The key clinical endpoint was non-target lesion (non-TL) revascularization throughout 5 years. A total of 88 patients with 88 lesions were available for OCT analysis 5 years after DES implantation. In-stent NA was observed in 16% of lesions with the majority of plaques being fibroatheromas (11.4%) followed by fibrocalcific plaques (5.7%). A total of 704 non-TL segments were serially evaluated by QCA. Between baseline and 5-year follow-up, the reduction in MLD was significantly more pronounced in patients with NA (-0.25 mm, 95% CI -0.36 to -0.17 mm) when compared with patients without NA (-0.13 mm, 95% CI -0.17 to -0.10 mm, P = 0.002). Similarly, non-TL revascularization was more frequent in patients with NA (78.6%) when compared with patients without NA (44.6%, P = 0.028) throughout 5 years. CONCLUSIONS: In-stent NA is more common among patients with angiographic and clinical evidence of native atherosclerosis progression suggesting similar pathophysiological mechanisms.SIRTAX trial is registered at http://www.clinicaltrials.gov/ct2/show/NCT00617084.


Asunto(s)
Estenosis Coronaria/patología , Stents Liberadores de Fármacos , Oclusión de Injerto Vascular/patología , Paclitaxel , Anciano , Angiografía Coronaria , Reestenosis Coronaria/patología , Estenosis Coronaria/cirugía , Progresión de la Enfermedad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Neointima/patología , Paclitaxel/administración & dosificación , Falla de Prótesis , Sirolimus/administración & dosificación , Tomografía de Coherencia Óptica/métodos , Moduladores de Tubulina/administración & dosificación
19.
Int J Cardiol ; 186: 178-85, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25828109

RESUMEN

BACKGROUND: Numerous studies have demonstrated an association between endothelial shear stress (ESS) and neointimal formation after stent implantation. However, the role of ESS on the composition of neointima and underlying plaque remains unclear. METHODS: Patients recruited in the Comfortable AMI-IBIS 4 study implanted with bare metal stents (BMS) or biolimus eluting stents (BES) that had biplane coronary angiography at 13 month follow-up were included in the analysis. The intravascular ultrasound virtual-histology (IVUS-VH) and the angiographic data were used to reconstruct the luminal surface, and the stent in the stented segments. Blood flow simulation was performed in the stent surface, which was assumed to represent the luminal surface at baseline, to assess the association between ESS and neointima thickness. The predominant ESS was estimated in 3-mm segments and was correlated with the amount of neointima, neointimal tissue composition, and with the changes in the underlying plaque burden and composition. RESULTS: Forty three patients (18 implanted with BMS and 25 with BES) were studied. In both stent groups negative correlations were noted between ESS and neointima thickness in BMS (P < 0.001) and BES (P = 0.002). In BMS there was a negative correlation between predominant ESS and the percentage of the neointimal necrotic core component (P = 0.015). In BES group, the limited neointima formation did not allow evaluation of the effect of ESS on its tissue characteristics. ESS did not affect vessel wall remodeling and the plaque burden and composition behind BMS (P > 0.10) and BES (P > 0.45). CONCLUSIONS: ESS determines neointimal formation in both BMS and BES and affects the composition of the neointima in BMS. Conversely, ESS does not impact the plaque behind struts irrespective of stent type throughout 13 months of follow-up.


Asunto(s)
Stents Liberadores de Fármacos , Endotelio Vascular/fisiopatología , Infarto del Miocardio/cirugía , Neointima/fisiopatología , Stents , Estrés Mecánico , Anciano , Implantación de Prótesis Vascular/instrumentación , Angiografía Coronaria , Método Doble Ciego , Electrocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad
20.
Int J Cardiovasc Imaging ; 31(5): 915-26, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25721728

RESUMEN

We assessed the feasibility and the procedural and long-term safety of intracoronary (i.c) imaging for documentary purposes with optical coherence tomography (OCT) and intravascular ultrasound (IVUS) in patients with acute ST-elevation myocardial infarction (STEMI) undergoing primary PCI in the setting of IBIS-4 study. IBIS4 (NCT00962416) is a prospective cohort study conducted at five European centers including 103 STEMI patients who underwent serial three-vessel coronary imaging during primary PCI and at 13 months. The feasibility parameter was successful imaging, defined as the number of pullbacks suitable for analysis. Safety parameters included the frequency of peri-procedural complications, and major adverse cardiac events (MACE), a composite of cardiac death, myocardial infarction (MI) and any clinically-indicated revascularization at 2 years. Clinical outcomes were compared with the results from a cohort of 485 STEMI patients undergoing primary PCI without additional imaging. Imaging of the infarct-related artery at baseline (and follow-up) was successful in 92.2% (96.6%) of patients using OCT and in 93.2% (95.5%) using IVUS. Imaging of the non-infarct-related vessels was successful in 88.7% (95.6%) using OCT and in 90.5% (93.3%) using IVUS. Periprocedural complications occurred <2.0% of OCT and none during IVUS. There were no differences throughout 2 years between the imaging and control group in terms of MACE (16.7 vs. 13.3%, adjusted HR1.40, 95% CI 0.77-2.52, p = 0.27). Multi-modality three-vessel i.c. imaging in STEMI patients undergoing primary PCI is consistent a high degree of success and can be performed safely without impact on cardiovascular events at long-term follow-up.


Asunto(s)
Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología , Imagen Multimodal/métodos , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/terapia , Intervención Coronaria Percutánea , Tomografía de Coherencia Óptica , Ultrasonografía Intervencional , Anciano , Fármacos Cardiovasculares/administración & dosificación , Stents Liberadores de Fármacos , Europa (Continente) , Estudios de Factibilidad , Femenino , Humanos , Masculino , Metales , Persona de Mediana Edad , Imagen Multimodal/efectos adversos , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/mortalidad , Infarto del Miocardio/patología , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/instrumentación , Intervención Coronaria Percutánea/mortalidad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Sirolimus/administración & dosificación , Sirolimus/análogos & derivados , Factores de Tiempo , Tomografía de Coherencia Óptica/efectos adversos , Resultado del Tratamiento , Ultrasonografía Intervencional/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...