Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Biomimetics (Basel) ; 9(5)2024 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-38786493

RESUMEN

The set-covering problem aims to find the smallest possible set of subsets that cover all the elements of a larger set. The difficulty of solving the set-covering problem increases as the number of elements and sets grows, making it a complex problem for which traditional integer programming solutions may become inefficient in real-life instances. Given this complexity, various metaheuristics have been successfully applied to solve the set-covering problem and related issues. This study introduces, implements, and analyzes a novel metaheuristic inspired by the well-established Growth Optimizer algorithm. Drawing insights from human behavioral patterns, this approach has shown promise in optimizing complex problems in continuous domains, where experimental results demonstrate the effectiveness and competitiveness of the metaheuristic compared to other strategies. The Growth Optimizer algorithm is modified and adapted to the realm of binary optimization for solving the set-covering problem, resulting in the creation of the Binary Growth Optimizer algorithm. Upon the implementation and analysis of its outcomes, the findings illustrate its capability to achieve competitive and efficient solutions in terms of resolution time and result quality.

2.
Heliyon ; 9(9): e19509, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37681134

RESUMEN

Purpose: Optimization studies in digital radiology help to reduce the radiological risk to patients and maximize the benefits associated with their clinical purpose. The aim of this study was to assess the optimization of lateral lumbar spine projection via a combination of exposure parameters adjustments and additional filtration using a sectional anthropomorphic phantom. Materials and methods: We evaluated the effects of peak voltage, tube loading, and low-cost filters made of copper, titanium, brass, and nickel on both the perceived and physical quality of 125 radiographs obtained in a computer radiography system. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) with their Figure of Merit (FOM), based on the entrance surface air kerma with backscatter (ESAK), was used to assess physical image quality. Results: The standard image had a perceived image quality, SNR, FOMSNR, CNR, FOMCNR and ESAK of 3.4, 22.3, 386.4, 23.6, 433.7 and 1.28 mGy, respectively. Copper (90.3% purity) and titanium (95.0% purity) filters reduced ESAK by an average of 60% without compromising diagnostic quality, while brass and nickel filters increased dose under the conditions of the study. Conclusions: Our findings show that optimizing lumbar spine projection can reduce radiation dose without compromising image quality. Low-cost copper and titanium filters can be valuable in resource-limited settings. Further research can explore additional strategies for radiological optimization.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...