Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
1.
Proc Natl Acad Sci U S A ; 121(22): e2322617121, 2024 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-38771873

RESUMEN

Optimal decision-making balances exploration for new information against exploitation of known rewards, a process mediated by the locus coeruleus and its norepinephrine projections. We predicted that an exploitation-bias that emerges in older adulthood would be associated with lower microstructural integrity of the locus coeruleus. Leveraging in vivo histological methods from quantitative MRI-magnetic transfer saturation-we provide evidence that older age is associated with lower locus coeruleus integrity. Critically, we demonstrate that an exploitation bias in older adulthood, assessed with a foraging task, is sensitive and specific to lower locus coeruleus integrity. Because the locus coeruleus is uniquely vulnerable to Alzheimer's disease pathology, our findings suggest that aging, and a presymptomatic trajectory of Alzheimer's related decline, may fundamentally alter decision-making abilities in later life.


Asunto(s)
Envejecimiento , Toma de Decisiones , Locus Coeruleus , Imagen por Resonancia Magnética , Locus Coeruleus/diagnóstico por imagen , Locus Coeruleus/fisiología , Humanos , Toma de Decisiones/fisiología , Anciano , Masculino , Femenino , Envejecimiento/fisiología , Enfermedad de Alzheimer/diagnóstico por imagen , Enfermedad de Alzheimer/patología , Persona de Mediana Edad , Anciano de 80 o más Años , Recompensa
2.
Magn Reson Med ; 2024 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-38703017

RESUMEN

PURPOSE: Magnetization transfer saturation (MTsat) mapping is commonly used to examine the macromolecular content of brain tissue. This study compared variable flip angle (VFA) T1 mapping against compressed-sensing MP2RAGE (csMP2RAGE) T1 mapping for accelerating MTsat imaging. METHODS: VFA, MP2RAGE, and csMP2RAGE were compared against inversion-recovery T1 in an aqueous phantom at 3 T. The same 1-mm VFA, MP2RAGE, and csMP2RAGE protocols were acquired in 4 healthy subjects to compare T1 and MTsat. Bloch-McConnell simulations were used to investigate differences between the phantom and in vivo T1 results. Ten healthy controls were imaged twice with the csMP2RAGE MTsat protocol to quantify repeatability. RESULTS: The MP2RAGE and csMP2RAGE protocols were 13.7% and 32.4% faster than the VFA protocol, respectively. At these scan times, all approaches provided strong repeatability and accurate T1 times (< 5% difference) in the phantom, but T1 accuracy was more impacted by T2 for VFA than for MP2RAGE. In vivo, VFA estimated longer T1 times than MP2RAGE and csMP2RAGE. Simulations suggest that the differences in the T1 measured using VFA, MP2RAGE, and inversion recovery could be explained by the magnetization-transfer effects. In the test-retest experiment, we found that the csMP2RAGE has a minimum detectable change of 2.3% for T1 mapping and 7.8% for MTsat imaging. CONCLUSIONS: We demonstrated that MP2RAGE can be used in place of VFA T1 mapping in an MTsat protocol. Furthermore, a shorter scan time and high repeatability can be achieved using the csMP2RAGE sequence.

3.
J Neurosci ; 44(19)2024 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-38388425

RESUMEN

Elevated iron deposition in the brain has been observed in older adult humans and persons with Alzheimer's disease (AD), and has been associated with lower cognitive performance. We investigated the impact of iron deposition, and its topographical distribution across hippocampal subfields and segments (anterior, posterior) measured along its longitudinal axis, on episodic memory in a sample of cognitively unimpaired older adults at elevated familial risk for AD (N = 172, 120 females, 52 males; mean age = 68.8 ± 5.4 years). MRI-based quantitative susceptibility maps were acquired to derive estimates of hippocampal iron deposition. The Mnemonic Similarity Task was used to measure pattern separation and pattern completion, two hippocampally mediated episodic memory processes. Greater hippocampal iron load was associated with lower pattern separation and higher pattern completion scores, both indicators of poorer episodic memory. Examination of iron levels within hippocampal subfields across its long axis revealed topographic specificity. Among the subfields and segments investigated here, iron deposition in the posterior hippocampal CA1 was the most robustly and negatively associated with the fidelity memory representations. This association remained after controlling for hippocampal volume and was observed in the context of normal performance on standard neuropsychological memory measures. These findings reveal that the impact of iron load on episodic memory performance is not uniform across the hippocampus. Both iron deposition levels as well as its spatial distribution, must be taken into account when examining the relationship between hippocampal iron and episodic memory in older adults at elevated risk for AD.


Asunto(s)
Enfermedad de Alzheimer , Hipocampo , Hierro , Imagen por Resonancia Magnética , Memoria Episódica , Humanos , Femenino , Masculino , Enfermedad de Alzheimer/metabolismo , Enfermedad de Alzheimer/diagnóstico por imagen , Enfermedad de Alzheimer/patología , Enfermedad de Alzheimer/psicología , Anciano , Hipocampo/metabolismo , Hipocampo/diagnóstico por imagen , Hipocampo/patología , Hierro/metabolismo , Persona de Mediana Edad
4.
MAGMA ; 37(2): 169-183, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38197908

RESUMEN

OBJECTIVE: To assess the possible influence of third-order shim coils on the behavior of the gradient field and in gradient-magnet interactions at 7 T and above. MATERIALS AND METHODS: Gradient impulse response function measurements were performed at 5 sites spanning field strengths from 7 to 11.7 T, all of them sharing the same exact whole-body gradient coil design. Mechanical fixation and boundary conditions of the gradient coil were altered in several ways at one site to study the impact of mechanical coupling with the magnet on the field perturbations. Vibrations, power deposition in the He bath, and field dynamics were characterized at 11.7 T with the third-order shim coils connected and disconnected inside the Faraday cage. RESULTS: For the same whole-body gradient coil design, all measurements differed greatly based on the third-order shim coil configuration (connected or not). Vibrations and gradient transfer function peaks could be affected by a factor of 2 or more, depending on the resonances. Disconnecting the third-order shim coils at 11.7 T also suppressed almost completely power deposition peaks at some frequencies. DISCUSSION: Third-order shim coil configurations can have major impact in gradient-magnet interactions with consequences on potential hardware damage, magnet heating, and image quality going beyond EPI acquisitions.


Asunto(s)
Imagen por Resonancia Magnética , Imanes , Imagen por Resonancia Magnética/métodos
5.
Hum Brain Mapp ; 45(4): e26539, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38124341

RESUMEN

Decreased long-range temporal correlations (LRTC) in brain signals can be used to measure cognitive effort during task execution. Here, we examined how learning a motor sequence affects long-range temporal memory within resting-state functional magnetic resonance imaging signal. Using the Hurst exponent (HE), we estimated voxel-wise LRTC and assessed changes over 5 consecutive days of training, followed by a retention scan 12 days later. The experimental group learned a complex visuomotor sequence while a complementary control group performed tightly matched movements. An interaction analysis revealed that HE decreases were specific to the complex sequence and occurred in well-known motor sequence learning associated regions including left supplementary motor area, left premotor cortex, left M1, left pars opercularis, bilateral thalamus, and right striatum. Five regions exhibited moderate to strong negative correlations with overall behavioral performance improvements. Following learning, HE values returned to pretraining levels in some regions, whereas in others, they remained decreased even 2 weeks after training. Our study presents new evidence of HE's possible relevance for functional plasticity during the resting-state and suggests that a cortical subset of sequence-specific regions may continue to represent a functional signature of learning reflected in decreased long-range temporal dependence after a period of inactivity.


Asunto(s)
Aprendizaje , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen , Mapeo Encefálico , Oxígeno
6.
Netw Neurosci ; 7(4): 1363-1388, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38144691

RESUMEN

A central goal in neuroscience is the development of a comprehensive mapping between structural and functional brain features, which facilitates mechanistic interpretation of brain function. However, the interpretability of structure-function brain models remains limited by a lack of biological detail. Here, we characterize human structural brain networks weighted by multiple white matter microstructural features including total intra-axonal cross-sectional area and myelin content. We report edge-weight-dependent spatial distributions, variance, small-worldness, rich club, hubs, as well as relationships with function, edge length, and myelin. Contrasting networks weighted by the total intra-axonal cross-sectional area and myelin content of white matter tracts, we find opposite relationships with functional connectivity, an edge-length-independent inverse relationship with each other, and the lack of a canonical rich club in myelin-weighted networks. When controlling for edge length, networks weighted by either fractional anisotropy, radial diffusivity, or neurite density show no relationship with whole-brain functional connectivity. We conclude that the co-utilization of structural networks weighted by total intra-axonal cross-sectional area and myelin content could improve our understanding of the mechanisms mediating the structure-function brain relationship.

7.
Brain Commun ; 5(6): fcad279, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37953840

RESUMEN

White matter hyperintensities are radiological abnormalities reflecting cerebrovascular dysfunction detectable using MRI. White matter hyperintensities are often present in individuals at the later stages of the lifespan and in prodromal stages in the Alzheimer's disease spectrum. Tissue alterations underlying white matter hyperintensities may include demyelination, inflammation and oedema, but these are highly variable by neuroanatomical location and between individuals. There is a crucial need to characterize these white matter hyperintensity tissue alterations in vivo to improve prognosis and, potentially, treatment outcomes. How different MRI measure(s) of tissue microstructure capture clinically-relevant white matter hyperintensity tissue damage is currently unknown. Here, we compared six MRI signal measures sampled within white matter hyperintensities and their associations with multiple clinically-relevant outcomes, consisting of global and cortical brain morphometry, cognitive function, diagnostic and demographic differences and cardiovascular risk factors. We used cross-sectional data from 118 participants: healthy controls (n = 30), individuals at high risk for Alzheimer's disease due to familial history (n = 47), mild cognitive impairment (n = 32) and clinical Alzheimer's disease dementia (n = 9). We sampled the median signal within white matter hyperintensities on weighted MRI images [T1-weighted (T1w), T2-weighted (T2w), T1w/T2w ratio, fluid-attenuated inversion recovery (FLAIR)] as well as the relaxation times from quantitative T1 (qT1) and T2* (qT2*) images. qT2* and fluid-attenuated inversion recovery signals within white matter hyperintensities displayed different age- and disease-related trends compared to normal-appearing white matter signals, suggesting sensitivity to white matter hyperintensity-specific tissue deterioration. Further, white matter hyperintensity qT2*, particularly in periventricular and occipital white matter regions, was consistently associated with all types of clinically-relevant outcomes in both univariate and multivariate analyses and across two parcellation schemes. qT1 and fluid-attenuated inversion recovery measures showed consistent clinical relationships in multivariate but not univariate analyses, while T1w, T2w and T1w/T2w ratio measures were not consistently associated with clinical variables. We observed that the qT2* signal was sensitive to clinically-relevant microstructural tissue alterations specific to white matter hyperintensities. Our results suggest that combining volumetric and signal measures of white matter hyperintensity should be considered to fully characterize the severity of white matter hyperintensities in vivo. These findings may have implications in determining the reversibility of white matter hyperintensities and the potential efficacy of cardio- and cerebrovascular treatments.

8.
Hum Brain Mapp ; 44(14): 4938-4955, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-37498014

RESUMEN

Resting-state (rs) functional magnetic resonance imaging (fMRI) is used to detect low-frequency fluctuations in the blood oxygen-level dependent (BOLD) signal across brain regions. Correlations between temporal BOLD signal fluctuations are commonly used to infer functional connectivity. However, because BOLD is based on the dilution of deoxyhemoglobin, it is sensitive to veins of all sizes, and its amplitude is biased by draining veins. These biases affect local BOLD signal location and amplitude, and may also influence BOLD-derived connectivity measures, but the magnitude of this venous bias and its relation to vein size and proximity is unknown. Here, veins were identified using high-resolution quantitative susceptibility maps and utilized in a biophysical model to investigate systematic venous biases on common local rsfMRI-derived measures. Specifically, we studied the impact of vein diameter and distance to veins on the amplitude of low-frequency fluctuations (ALFF), fractional ALFF (fALFF), Hurst exponent (HE), regional homogeneity (ReHo), and eigenvector centrality values in the grey matter. Values were higher across all distances in smaller veins, and decreased with increasing vein diameter. Additionally, rsfMRI values associated with larger veins decrease with increasing distance from the veins. ALFF and ReHo were the most biased by veins, while HE and fALFF exhibited the smallest bias. Across all metrics, the amplitude of the bias was limited in voxel-wise data, confirming that venous structure is not the dominant source of contrast in these rsfMRI metrics. Finally, the models presented can be used to correct this venous bias in rsfMRI metrics.


Asunto(s)
Benchmarking , Mapeo Encefálico , Humanos , Mapeo Encefálico/métodos , Encéfalo/diagnóstico por imagen , Corteza Cerebral , Imagen por Resonancia Magnética/métodos
9.
Magn Reson Med ; 90(5): 1762-1775, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37332194

RESUMEN

PURPOSE: Imaging biomarkers with increased myelin specificity are needed to better understand the complex progression of neurological disorders. Inhomogeneous magnetization transfer (ihMT) imaging is an emergent technique that has a high degree of specificity for myelin content but suffers from low signal to-noise ratio (SNR). This study used simulations to determine optimal sequence parameters for ihMT imaging for use in high-resolution cortical mapping. METHODS: MT-weighted cortical image intensity and ihMT SNR were simulated using modified Bloch equations for a range of sequence parameters. The acquisition time was limited to 4.5 min/volume. A custom MT-weighted RAGE sequence with center-out k-space encoding was used to enhance SNR at 3 T. Pulsed MT imaging was studied over a range of saturation parameters, and the impact of the turbo factor on the effective ihMT resolution was investigated. 1 mm isotropic ihMTsat maps were generated in 25 healthy adults. RESULTS: Greater SNR was observed for larger number of bursts consisting of 6-8 saturation pulses each, combined with a high readout turbo factor. However, that protocol suffered from a point spread function that was more than twice the nominal resolution. For high-resolution cortical imaging, we selected a protocol with a higher effective resolution at the cost of a lower SNR. We present the first group-average ihMTsat whole-brain map at 1 mm isotropic resolution. CONCLUSION: This study presents the impact of saturation and excitation parameters on ihMTsat SNR and resolution. We demonstrate the feasibility of high-resolution cortical myelin imaging using ihMTsat in less than 20 min.


Asunto(s)
Encéfalo , Imagen por Resonancia Magnética , Adulto , Humanos , Imagen por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen , Vaina de Mielina , Relación Señal-Ruido , Biomarcadores
10.
Neuroimage ; 274: 120159, 2023 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-37150332

RESUMEN

Diffusion MRI (dMRI) is a valuable imaging technique to study the connectivity and microstructure of the brain in vivo. However, the resolution of dMRI is limited by the low signal-to-noise ratio (SNR) of this technique. Various multi-shot acquisition strategies have been developed to achieve sub-millimeter resolution, but they require long scan times which can be restricting for patient scans. Alternatively, the SNR of single-shot acquisitions can be increased by using a spiral readout trajectory to minimize the sequence echo time. Imaging at ultra-high fields (UHF) could further increase the SNR of single-shot dMRI; however, the shorter T2* of brain tissue and the greater field non-uniformities at UHFs will degrade image quality, causing image blurring, distortions, and signal loss. In this study, we investigated the trade-off between the SNR and resolution of different k-space trajectories, including echo planar imaging (EPI), partial Fourier EPI, and spiral trajectories, over a range of dMRI resolutions at 7T. The effective resolution, spatial specificity and sharpening effect were measured from the point spread function (PSF) of the simulated diffusion sequences for a nominal resolution range of 0.6-1.8 mm. In-vivo partial brain scans at a nominal resolution of 1.5 mm isotropic were acquired using the three readout trajectories to validate the simulation results. Field probes were used to measure dynamic magnetic fields offline up to the 3rd order of spherical harmonics. Image reconstruction was performed using static ΔB0 field maps and the measured trajectories to correct image distortions and artifacts, leaving T2* effects as the primary source of blurring. The effective resolution was examined in fractional anisotropy (FA) maps calculated from a multi-shell dataset with b-values of 300, 1000, and 2000 s/mm2 in 5, 16, and 48 directions, respectively. In-vivo scans at nominal resolutions of 1, 1.2, and 1.5 mm were acquired and the SNR of the different trajectories calculated using the multiple replica method to investigate the SNR. Finally, in-vivo whole brain scans with an effective resolution of 1.5 mm isotropic were acquired to explore the SNR and efficiency of different trajectories at a matching effective resolution. FA and intra-cellular volume fraction (ICVF) maps calculated using neurite orientation dispersion and density imaging (NODDI) were used for the comparison. The simulations and in vivo imaging results showed that for matching nominal resolutions, EPI trajectories had the highest specificity and effective resolution with maximum image sharpening effect. However, spirals have a significantly higher SNR, in particular at higher resolutions and even when the effective image resolutions are matched. Overall, this work shows that the higher SNR of single-shot spiral trajectories at 7T allows us to achieve higher effective resolutions compared to EPI and PF-EPI to map the microstructure and connectivity of small brain structures.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Procesamiento de Imagen Asistido por Computador , Humanos , Relación Señal-Ruido , Imagen de Difusión por Resonancia Magnética/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Encéfalo/diagnóstico por imagen , Imagen Eco-Planar/métodos
11.
Hum Brain Mapp ; 44(9): 3913-3925, 2023 06 15.
Artículo en Inglés | MEDLINE | ID: mdl-37126580

RESUMEN

Following the development of magnetic resonance imaging (MRI) methods to assay the integrity of catecholamine nuclei, including the locus coeruleus (LC), there has been an effort to develop automated methods that can accurately segment this small structure in an automated manner to promote its widespread use and overcome limitations of manual segmentation. Here we characterize an automated LC segmentation approach (referred to as the funnel-tip [FT] method) in healthy individuals and individuals with LC degeneration in the context of Alzheimer's disease (AD, confirmed with tau-PET imaging using [18F]MK6240). The first sample included n = 190 individuals across the AD spectrum from cognitively normal to moderate AD. LC signal assayed with FT segmentation showed excellent agreement with manual segmentation (intraclass correlation coefficient [ICC] = 0.91). Compared to other methods, the FT method showed numerically higher correlation to AD status (defined by presence of tau: Cohen's d = 0.64) and AD severity (Braak stage: Pearson R = -.35, cognitive function: R = .25). In a separate sample of n = 12 control participants, the FT method showed excellent scan-rescan reliability (ICC = 0.82). In another sample of n = 30 control participants, we found that the structure of the LC defined by FT segmentation approximated its expected shape as a contiguous line: <5% of LC voxels strayed >1 voxel (0.69 mm) from this line. The FT LC segmentation shows high agreement with manual segmentation and captures LC degeneration in AD. This practical method may facilitate larger research studies of the human LC-norepinephrine system and has potential to support future use of neuromelanin-sensitive MRI as a clinical biomarker.


Asunto(s)
Enfermedad de Alzheimer , Locus Coeruleus , Humanos , Locus Coeruleus/diagnóstico por imagen , Reproducibilidad de los Resultados , Enfermedad de Alzheimer/diagnóstico por imagen , Enfermedad de Alzheimer/patología , Imagen por Resonancia Magnética/métodos , Norepinefrina
12.
BMJ Open ; 13(4): e073063, 2023 04 13.
Artículo en Inglés | MEDLINE | ID: mdl-37055215

RESUMEN

INTRODUCTION: Therapeutic hypothermia (TH) became the standard of care treatment for neonates with moderate and severe neonatal encephalopathy (NE) in most industrialized countries about 10 years ago. Although TH is effective in reducing mortality and the incidence of severe developmental disabilities, the recent literature converges in reporting frequent cognitive and behavioural difficulties at school entry in children with NE-TH. Although these challenges are deemed minor compared with cerebral palsy and intellectual disability, their impacts on a child's self-determination and family's well-being are quite significant. Therefore, the nature and extent of these difficulties need to be comprehensively described so that appropriate care can be offered. METHODS AND ANALYSIS: The current study will be the largest follow-up study of neonates with NE treated with TH to characterize their developmental outcomes and associated brain structural profiles at 9 years of age. Specifically, we will compare executive function, attention, social cognition, behaviour, anxiety, self-esteem, peer problems, brain volume, cortical features, white matter microstructure and myelination between children with NE-TH and matched peers without NE. Associations of perinatal risk factors and structural brain integrity with cognitive, behavioural and psycho-emotional deficits will be evaluated to inform about the potential aggravating and protective factors associated with function. ETHICS AND DISSEMINATION: This study is supported by the Canadian Institute of Health Research (202203PJT-480065-CHI-CFAC-168509), and received approval from the Pediatric Ethical Review Board of the McGill University Health Center (MP-37-2023-9320). The study findings will be disseminated in scientific journals and conferences and presented to parental associations and healthcare providers to inform best practices. TRIAL REGISTRATION NUMBER: NCT05756296.


Asunto(s)
Encefalopatías , Parálisis Cerebral , Hipotermia Inducida , Hipotermia , Enfermedades del Recién Nacido , Recién Nacido , Embarazo , Femenino , Niño , Humanos , Estudios de Seguimiento , Canadá
13.
Hum Brain Mapp ; 44(8): 3023-3044, 2023 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-36896711

RESUMEN

Statistical effects of cortical metrics derived from standard T1- and T2-weighted magnetic resonance imaging (MRI) images, such as gray-white matter contrast (GWC), boundary sharpness coefficient (BSC), T1-weighted/T2-weighted ratio (T1w/T2w), and cortical thickness (CT), are often interpreted as representing or being influenced by intracortical myelin content with little empirical evidence to justify these interpretations. We first examined spatial correspondence with more biologically specific microstructural measures, and second compared between-marker age-related trends with the underlying hypothesis that different measures primarily driven by similar changes in myelo- and microstructural underpinnings should be highly related. Cortical MRI markers were derived from MRI images of 127 healthy subjects, aged 18-81, using cortical surfaces that were generated with the CIVET 2.1.0 pipeline. Their gross spatial distributions were compared with gene expression-derived cell-type densities, histology-derived cytoarchitecture, and quantitative R1 maps acquired on a subset of participants. We then compared between-marker age-related trends in their shape, direction, and spatial distribution of the linear age effect. The gross anatomical distributions of cortical MRI markers were, in general, more related to myelin and glial cells than neuronal indicators. Comparing MRI markers, our results revealed generally high overlap in spatial distribution (i.e., group means), but mostly divergent age trajectories in the shape, direction, and spatial distribution of the linear age effect. We conclude that the microstructural properties at the source of spatial distributions of MRI cortical markers can be different from microstructural changes that affect these markers in aging.


Asunto(s)
Vaina de Mielina , Sustancia Blanca , Humanos , Vaina de Mielina/fisiología , Imagen por Resonancia Magnética/métodos , Sustancia Gris , Envejecimiento
14.
Cereb Cortex ; 33(12): 7468-7476, 2023 06 08.
Artículo en Inglés | MEDLINE | ID: mdl-36879454

RESUMEN

Age-related changes of intracortical myelin in bipolar disorder (BD) have been observed to deviate from the quadratic age curve observed in healthy controls (HC), but it is unclear if this holds at varying cortical depths. From BD (n = 44; age range = 17.6-45.5 years) and HC (n = 60; age range = 17.1-45.8 years) participants, we collected 3T T1-weighted (T1w) images with strong intracortical contrast. Signal values were sampled from 3 equivolume cortical depths. Linear mixed models were used to compare age-related changes in the T1w signal between depths and between groups at each depth. In HC, the age-related changes were significantly different between the superficial one-fourth depth and the deeper depths in the right ventral somatosensory (t = -4.63; FDRp = 0.00025), left dorsomedial somatosensory (t = -3.16; FDRp = 0.028), left rostral ventral premotor (t = -3.16; FDRp = 0.028), and right ventral inferior parietal cortex (t = -3.29; FDRp = 0.028). BD participants exhibited no differences in the age-related T1w signal between depths. Illness duration was negatively correlated with the T1w signal at the one-fourth depth in the right anterior cingulate cortex (rACC; rho = -0.50; FDRp = 0.029). Physiological age-related and depth-specific variation in the T1w signal were not observed in BD. The T1w signal in the rACC may reflect lifetime disease burden in the disorder.


Asunto(s)
Trastorno Bipolar , Vaina de Mielina , Humanos , Adolescente , Adulto Joven , Adulto , Persona de Mediana Edad , Trastorno Bipolar/diagnóstico por imagen , Giro del Cíngulo , Lóbulo Parietal , Cabeza , Imagen por Resonancia Magnética/métodos
15.
Naunyn Schmiedebergs Arch Pharmacol ; 396(9): 2095-2103, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-36928556

RESUMEN

JNJ-42491293 is a metabotropic glutamate 2 (mGlu2) positive allosteric modulator (PAM) that was radiolabelled with [11C]- to serve as a positron emission tomography (PET) ligand. Indeed, in vitro, the molecule displays high selectivity at mGlu2 receptors. However, PET experiments performed in rats, macaques and humans, have suggested that [11C]-JNJ-42491293 could interact with an unidentified, non-mGlu2 receptor binding site. The brain distribution of [11C]-JNJ-42491293 has not been determined in the brain of the common marmoset, a small non-human primate increasingly used in neuroscience research. Here, we investigated the distribution of [11C]-JNJ-42491293 in the marmoset brain. Three marmosets underwent brain magnetic resonance imaging (MRI) and 90-min dynamic PET scans with [11C]-JNJ-42491293 in combination with vehicle or the mGlu2 PAM AZD8529 (0.1, 1 and 10 mg/kg). In the scans in which [11C]-JNJ-42491293 was co-administered with vehicle, the brain areas with the highest standardised uptake values (SUVs) were the midbrain, cerebellum and thalamus, while the lowest SUVs were found in the pons. The addition of AZD8529 (0.1, 1 and 10 mg/kg) to [11C]-JNJ-42491293 did not modify the SUVs obtained with [11C]-JNJ-42491293 alone, and ex vivo blocking autoradiography with PAM AZD8529 (10, 100, 300 µM) on marmoset brain sections showed increased signals in the blocking conditions compared to vehicle, suggesting that no competition occurred between the 2 ligands. The results we obtained here do not suggest that [11C]-JNJ-42491293 interacts selectively, or even at all, with mGlu2 receptors in the marmoset, in agreement with findings previously reported in macaque and human.


Asunto(s)
Callithrix , Tomografía de Emisión de Positrones , Ratas , Animales , Tomografía de Emisión de Positrones/métodos , Encéfalo/diagnóstico por imagen , Encéfalo/metabolismo , Sitios de Unión , Unión Proteica
16.
J Magn Reson Imaging ; 58(1): 294-300, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36373996

RESUMEN

BACKGROUND: The integrity and function of catecholamine neurotransmitter systems can be assessed using neuromelanin-sensitive MRI (NM-MRI). The relevance of this method to neurodegenerative and psychiatric disorders is becoming increasingly evident, and it has potential as a clinical biomarker. PURPOSE: To support future application of NM-MRI as a clinical biomarker by defining the normative range of NM-MRI signal and volume metrics in cognitively normal older adults. STUDY TYPE: Prospective. POPULATION: A total of 152 cognitively normal older adults aged 53-86 years old, including 41 participants who had follow-up NM-MRI data collected 9-16 months later. FIELD STRENGTH/SEQUENCE: A 3.0 T; NM-MRI turbo spin echo and T1-weighted magnetization-prepared rapid acquisition with gradient echo sequences. ASSESSMENT: NM-MRI images were processed to yield summary measures of volume and signal (contrast-to-noise ratio, CNR) for the substantia nigra (SN) and locus coeruleus (LC) using a recently developed software employing a fully automated algorithm. Change in these metrics over time was also assessed. STATISTICAL TESTS: Mean and standard deviation of NM-MRI metrics were calculated; change over time was tested for significance using 1-sample t-tests. P values < 0.05 were considered statistically significant. RESULTS: At baseline SN signal (CNR) was 10.02% (left) and 10.28% (right) and LC signal was 24.71% (left) and 20.42% (right). Baseline SN volume was 576 mm3 (left) and 540 mm3 (right) and LC volume was 6.31 mm3 (left) and 6.30 mm3 (right). The only NM-MRI metric showing significant change was a decrease in left SN volume (t40  = -2.57, P = 0.014). DATA CONCLUSION: We report normative values for NM-MRI signal and volume in the SN and LC of cognitively normal older adults and explore their change over time. These values may help future efforts to use NM-MRI as a clinical biomarker by facilitating identification of patients with extreme NM-MRI values. TECHNICAL EFFICACY STAGE: 1.


Asunto(s)
Enfermedad de Parkinson , Humanos , Anciano , Persona de Mediana Edad , Anciano de 80 o más Años , Estudios Prospectivos , Imagen por Resonancia Magnética/métodos , Sustancia Negra/diagnóstico por imagen , Biomarcadores
17.
Neuroimage ; 263: 119612, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36070839

RESUMEN

Multimodal magnetic resonance imaging (MRI) has accelerated human neuroscience by fostering the analysis of brain microstructure, geometry, function, and connectivity across multiple scales and in living brains. The richness and complexity of multimodal neuroimaging, however, demands processing methods to integrate information across modalities and to consolidate findings across different spatial scales. Here, we present micapipe, an open processing pipeline for multimodal MRI datasets. Based on BIDS-conform input data, micapipe can generate i) structural connectomes derived from diffusion tractography, ii) functional connectomes derived from resting-state signal correlations, iii) geodesic distance matrices that quantify cortico-cortical proximity, and iv) microstructural profile covariance matrices that assess inter-regional similarity in cortical myelin proxies. The above matrices can be automatically generated across established 18 cortical parcellations (100-1000 parcels), in addition to subcortical and cerebellar parcellations, allowing researchers to replicate findings easily across different spatial scales. Results are represented on three different surface spaces (native, conte69, fsaverage5), and outputs are BIDS-conform. Processed outputs can be quality controlled at the individual and group level. micapipe was tested on several datasets and is available at https://github.com/MICA-MNI/micapipe, documented at https://micapipe.readthedocs.io/, and containerized as a BIDS App http://bids-apps.neuroimaging.io/apps/. We hope that micapipe will foster robust and integrative studies of human brain microstructure, morphology, function, cand connectivity.


Asunto(s)
Conectoma , Procesamiento Automatizado de Datos , Neuroimagen , Programas Informáticos , Humanos , Encéfalo/diagnóstico por imagen , Encéfalo/anatomía & histología , Conectoma/métodos , Imagen de Difusión Tensora , Imagen por Resonancia Magnética/métodos , Neuroimagen/métodos , Programas Informáticos/normas , Procesamiento Automatizado de Datos/métodos , Procesamiento Automatizado de Datos/normas
18.
Neuropsychopharmacology ; 47(5): 1128-1136, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35177805

RESUMEN

The clinical and pathophysiological correlates of locus coeruleus (LC) degeneration in Alzheimer's disease (AD) could be clarified using a method to index LC integrity in vivo, neuromelanin-sensitive MRI (NM-MRI). We examined whether integrity of the LC-norepinephrine system, assessed with NM-MRI, is associated with stage of AD and with neuropsychiatric symptoms (NPS), independent of cortical pathophysiology (amyloid-ß and tau burden). Cognitively normal older adults (n = 118), and individuals with mild cognitive impairment (MCI, n = 44), and AD (n = 28) underwent MR imaging and tau and amyloid-ß positron emission tomography (with [18F]MK6240 and [18F]AZD4694, respectively). Integrity of the LC-norepinephrine system was assessed based on contrast-to-noise ratio of the LC on NM-MRI images. Braak stage of AD was derived from regional binding of [18F]MK6240. NPS were assessed with the Mild Behavioral Impairment Checklist (MBI-C). LC signal contrast was decreased in tau-positive participants (t186 = -4.00, p = 0.0001) and negatively correlated to Braak stage (Spearman ρ = -0.31, p = 0.00006). In tau-positive participants (n = 51), higher LC signal predicted NPS severity (ρ = 0.35, p = 0.019) independently of tau burden, amyloid-ß burden, and cortical gray matter volume. This relationship appeared to be driven by the impulse dyscontrol domain of NPS, which was highly correlated to LC signal (ρ = 0.44, p = 0.0027). NM-MRI reveals loss of LC integrity that correlates to severity of AD. However, LC preservation in AD may also have negative consequences by conferring risk for impulse control symptoms. NM-MRI shows promise as a practical biomarker that could have utility in predicting the risk of NPS or guiding their treatment in AD.


Asunto(s)
Enfermedad de Alzheimer , Anciano , Enfermedad de Alzheimer/diagnóstico por imagen , Enfermedad de Alzheimer/metabolismo , Péptidos beta-Amiloides/metabolismo , Humanos , Locus Coeruleus/diagnóstico por imagen , Locus Coeruleus/metabolismo , Norepinefrina/metabolismo , Tomografía de Emisión de Positrones , Proteínas tau/metabolismo
19.
Brain Struct Funct ; 227(3): 793-807, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34704176

RESUMEN

In motor learning, sequence specificity, i.e. the learning of specific sequential associations, has predominantly been studied using task-based fMRI paradigms. However, offline changes in resting state functional connectivity after sequence-specific motor learning are less well understood. Previous research has established that plastic changes following motor learning can be divided into stages including fast learning, slow learning and retention. A description of how resting state functional connectivity after sequence-specific motor sequence learning (MSL) develops across these stages is missing. This study aimed to identify plastic alterations in whole-brain functional connectivity after learning a complex motor sequence by contrasting an active group who learned a complex sequence with a control group who performed a control task matched for motor execution. Resting state fMRI and behavioural performance were collected in both groups over the course of 5 consecutive training days and at follow-up after 12 days to encompass fast learning, slow learning, overall learning and retention. Between-group interaction analyses showed sequence-specific decreases in functional connectivity during overall learning in the right supplementary motor area (SMA). We found that connectivity changes in a key region of the motor network, the superior parietal cortex (SPC) were not a result of sequence-specific learning but were instead linked to motor execution. Our study confirms the sequence-specific role of SMA that has previously been identified in online task-based learning studies, and extends it to resting state network changes after sequence-specific MSL.


Asunto(s)
Mapeo Encefálico , Corteza Motora , Aprendizaje , Imagen por Resonancia Magnética , Corteza Motora/diagnóstico por imagen , Descanso
20.
Neuroscience ; 480: 143-154, 2022 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-34774970

RESUMEN

The common marmoset has emerged as a popular model in neuroscience research, in part due to its reproductive efficiency, genetic and neuroanatomical similarities to humans and the successful generation of transgenic lines. Stereotaxic procedures in marmosets are guided by 2D stereotaxic atlases, which are constructed with a limited number of animals and fail to account for inter-individual variability in skull and brain size. Here, we developed a frameless imaging-guided stereotaxic system that improves upon traditional approaches by using subject-specific registration of computed tomography (CT), magnetic resonance imaging (MRI) and positron emission tomography (PET) data to identify a surgical target, namely the putamen, in two marmosets. The skull surface was laser-scanned to create a point cloud that was registered to the 3D reconstruction of the skull from CT. Reconstruction of the skull, as well as of the brain from MR images, was crucial for surgical planning. Localisation and injection into the putamen was done using a 6-axis robotic arm controlled by a surgical navigation software (Brainsight™). Integration of subject-specific registration and frameless stereotaxic navigation allowed target localisation specific to each animal. Injection of alpha-synuclein fibrils into the putamen triggered progressive neurodegeneration of the nigro-striatal system, a key feature of Parkinson's disease. Four months post-surgery, a PET scan found evidence of nigro-striatal denervation, supporting accurate targeting of the putamen during co-registration and subsequent surgery. Our results suggest that this approach, coupled with frameless stereotaxic neuronavigation, is accurate in localising surgical targets and can be used to assess endpoints for longitudinal studies.


Asunto(s)
Neuronavegación , Procedimientos Quirúrgicos Robotizados , Animales , Callithrix , Imagen por Resonancia Magnética , Tomografía de Emisión de Positrones , Técnicas Estereotáxicas , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...