Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
BMC Pulm Med ; 22(1): 464, 2022 Dec 05.
Artículo en Inglés | MEDLINE | ID: mdl-36471325

RESUMEN

OBJECTIVES: Fibrinolytic therapy can be effective for management of complex pleural effusions. Tissue plasminogen activator (tPA, 10 mg) and deoxyribonuclease (DNAse) every 12 h with a dwell time of one hour is a common strategy based on published data. We used a simpler protocol of tPA (4 mg) without DNAse but with a longer dwell time of 12 h, repeated daily. We reviewed our results. METHODS: Charts were reviewed and demographics, clinical data and treatment information were abstracted. Outcomes were assessed based on radiographic findings and need for surgery. RESULTS: Two hundred and fifteen effusions in 207 patients (8 bilateral) were identified. 85% were either infectious or malignant. Two hundred and forty nine chest tubes were used: 84% were 10 Fr or 12 Fr and 7% were PleurX®. Five hundred and thirty one doses of tPA were given. The median number of doses per effusion was 2 (range 1-10), and 84% of effusions were treated with three or fewer doses. There were no significant bleeding complications. Median time to chest tube removal was 6 days (range 1 to 98, IQR 4 to 10). Drainage was considered complete for 78% of effusions, while 6% required decortication. CONCLUSIONS: Low dose tPA daily with a 12 h dwell time may be as effective as the standard regimen of tPA and DNAse twice daily with one hour dwell. For most patients only three doses were required, and small pigtail catheters were sufficient. This regimen uses less medication and is logistically much easier than the current standard.


Asunto(s)
Empiema Pleural , Activador de Tejido Plasminógeno , Humanos , Desoxirribonucleasas/administración & dosificación , Desoxirribonucleasas/uso terapéutico , Empiema Pleural/tratamiento farmacológico , Fibrinolíticos/uso terapéutico , Estudios Retrospectivos , Activador de Tejido Plasminógeno/administración & dosificación , Activador de Tejido Plasminógeno/uso terapéutico , Esquema de Medicación
2.
Semin Thorac Cardiovasc Surg ; 25(3): 218-27, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24331144

RESUMEN

Accurate mediastinal staging is essential to determining the optimal therapeutic strategy for many patients with lung cancer. Computed tomography and positron emission tomography are first steps, but frequently tissue sampling is recommended to confirm the radiographic findings. Mediastinoscopy has been the gold standard for thirty years, but the new technologies of esophageal endoscopic ultrasound and endobronchial ultrasound provide a less invasive method for biopsy. These techniques enable needle aspiration sampling of nearly all mediastinal and hilar lymph nodes, and experience with them is now sufficiently mature to conclude that they can be equivalent if not preferable to mediastinoscopy. The keys to achieving accurate results are skillful execution combined with sound clinical judgment regarding when to use which techniques. Patients with lung cancer are best served by clinicians experienced with all three methods for invasive mediastinal staging.


Asunto(s)
Broncoscopía , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico , Endosonografía , Neoplasias Pulmonares/patología , Ganglios Linfáticos/patología , Mediastinoscopía , Humanos , Metástasis Linfática , Estadificación de Neoplasias , Valor Predictivo de las Pruebas
3.
Innovations (Phila) ; 4(4): 221-4, 2009 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22437124

RESUMEN

A 90-year-old woman with two previous mitral valve replacements, presented with pulmonary edema due to mitral regurgitation from degeneration of her bioprosthetic mitral valve. A minimally invasive approach was used to replace the bioprosthetic mitral valve. During surgery, the bioprosthetic valve was noted to be too adherent to the endocardium of the left atrium, making removal of the prosthesis not only difficult, but also potentially harmful. The new bioprosthetic valve was instead placed using a valve-in-valve approach.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...