1.
Adv Biol (Weinh) ; 7(7): e2300051, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37102630

RESUMEN

Lowering intraocular pressure (IOP) by placement of a glaucoma shunt is an effective treatment for glaucoma. However, fibrosis of the outflow site can hamper surgical outcome. In this study, the antifibrotic effect of adding an endplate (with or without microstructured surface topographies) to a microshunt made of poly(styrene-block-isobutylene-block-styrene) is investigated. New Zealand white rabbits are implanted with a control implant (without endplate) and modified implants. Afterward, bleb morphology and IOP is recorded for 30 days. After killing of the animals, eyes are collected for histology, Addition of an endplate extended bleb survival, Topography-990 has the longest recorded bleb-survival time. Histology reveals that the addition of an endplate increases the presence of myofibroblasts, macrophages, polymorphonuclear cells, and foreign body giant cells compared to the control. However, an increased capsule thickness and inflammatory response are observed in the groups with surface topographies, The addition of an endplate results in prolonged bleb survival, demonstrating that engineering of the shape of glaucoma implants could prolong bleb functionality. Future research should further elaborate the effect of surface topographies on long-term bleb survival, since an increased presence of pro-fibrotic cells and increased capsule thickness are observed compared to the control.


Asunto(s)
Implantes de Drenaje de Glaucoma , Glaucoma , Animales , Conejos , Implantes de Drenaje de Glaucoma/efectos adversos , Glaucoma/cirugía , Presión Intraocular , Ojo , Fibrosis , Estirenos
2.
Nanoscale ; 14(6): 2266-2276, 2022 Feb 10.
Artículo en Inglés | MEDLINE | ID: mdl-35080562

RESUMEN

The fabrication of a flexible supercapacitor with state-of-the-art performance is described, based on a facile and low-cost fabrication method that encompasses aligned carbon nanotube arrays (ACNTA)-polyaniline/polydimethylsiloxane electrodes (ACNTA-PANI/PDMS). The ACNTA were partially embedded in PDMS to ensure excellent adhesion and integration whilst PANI was electrodeposited on its surface to improve energy storage properties. The supercapacitor structure and morphology were investigated by Raman spectroscopy and scanning electron microscopy (SEM), respectively. The energy storage properties of the electrodes were evaluated in two and three-electrode configurations. The maximum value of specific capacitance was 408 mF cm-2 (265 F g-1) at 1 mA cm-2, and a high energy density of 20 µW h cm-2 (25.5 W h kg-1) was achieved at a power density of 100 µW cm-2 (126.6 W kg-1) for a symmetric two-electrode device. The device showed a good capacitance retention of 76% after 5000 cycles and was able to maintain 80% of its electrochemical properties while being measured at different bending angles, demonstrating excellent mechanical agility performance under extreme conditions and some of the highest carbon-based energy storage properties.

3.
Sci Rep ; 10(1): 21457, 2020 12 08.
Artículo en Inglés | MEDLINE | ID: mdl-33293628

RESUMEN

In recent years, organic electronic materials have been shown to be a promising tool, even transplanted in vivo, for transducing light stimuli to non-functioning retinas. Here we developed a bio-hybrid optoelectronic device consisting of patterned organic polymer semiconductors interfaced with an electrolyte solution in a closed sandwich architecture in order to study the photo-response of photosensitive semiconducting layers or patterns in an environment imitating biological extracellular fluids. We demonstrate an artificial retina model composed of on an array of 42,100 pixels made of three different conjugated polymers via inkjet printing with 110 pixels/mm2 packing density. Photo-sensing through three-colour pixelation allows to resolve incoming light spectrally and spatially. The compact colour sensitive optoelectronic device represents an easy-to-handle photosensitive platform for the study of the photo response of artificial retina systems.

4.
ACS Appl Mater Interfaces ; 12(10): 11898-11906, 2020 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-32058686

RESUMEN

Research into carbon nanotubes (CNTs) has been a hot topic for almost 3 decades, and it is now that we are beginning to observe the impact of advanced applictions of this nanomaterial in areas such as electronics. Currently, in order to mass produce CNT devices, either large-scale synthesis, followed by numerous energy-intensive processing steps or photolithography processes, including several sputter-deposition steps, are required to pattern this material to fabricate functional devices. In the work reported here, through the utilization of a universal catalyst precursor (cyclopentadienyl iron dicarbonyl dimer) and the optimization of solution parameters, patterned high-quality vertically aligned arrays of single- and few-walled CNTs have been synthesized via various inexpensive, commercially scalable methods such as inkjet printing, stamp printing, spray painting, and even handwriting. The two-step process of precursor printing, followed immediately by CNT growth, results in CNTs with a Raman ID/IG ratio of 0.073, demonstrating very high-quality nanotubes. This process eliminates time-consuming and costly CNT post processing techniques or the deposition of numerous substrate barrier and catalyst layers to achieve device manufacturing. As a result, this method has the potential to provide a route for the large-scale synthesis of high-quality single- and few-walled CNTs that can be applied in industrial settings.

5.
ACS Appl Mater Interfaces ; 12(7): 8456-8465, 2020 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-31985204

RESUMEN

Rapid growth of the internet of things and health monitoring systems have stimulated the development of flexible, wearable, and conformal embedded electronics with the unprecedented need for energy storage systems fully adaptable to diverse form factors. Conventional fabrication methods, such as photolithography for electronics and electrode winding/stacking for energy storage systems, struggle as fabrication strategies to produce devices with three-dimensional, stretchable, and conformal form factors. In this study, we demonstrate the fabrication of supercapacitors on 3D objects through inkjet and water-transfer printing. The devices are initially printed on a water-soluble substrate, which is then placed on the surface of water. Once the substrate is dissolved, the level of water is lowered until the devices are transferred on to the submerged 3D object. As a proof of concept, planar supercapacitors constituted of a silver nanoparticle-based current collector, nickel(II) oxide (NiO) nanoparticle-based active electrodes, and ultraviolet-cured triacrylate polymer-based solid-state electrolyte were used as model materials. The conformal supercapacitors showed a maximum areal capacitance of 87.2 mF·cm-2 at a voltage window of 0-1.5 V. Moreover, the concept of water transfer was further explored with a particular focus on wearable applications by transferring the supercapacitors onto the skin of a human subject to realize epidermal energy storage. This new class of conformal electrochemical energy storage offers a new alternative approach toward monolithically integrated/object-tailored energy storage systems that are essential for complex-shaped devices for internet of things and flexible/on-skin electronic applications.

6.
ACS Appl Mater Interfaces ; 11(43): 39560-39573, 2019 Oct 30.
Artículo en Inglés | MEDLINE | ID: mdl-31552734

RESUMEN

Recent interest in the fields of human motion monitoring, electronic skin, and human-machine interface technology demands strain sensors with high stretchability/compressibility (ε > 50%), high sensitivity (or gauge factor (GF > 100)), and long-lasting electromechanical compliance. However, current metal- and semiconductor-based strain sensors have very low (ε < 5%) stretchability or low sensitivity (GF < 2), typically sacrificing the stretchability for high sensitivity. Composite elastomer sensors are a solution where the challenge is to improve the sensitivity to GF > 100. We propose a simple, low-cost fabrication of mechanically compliant, physically robust metallic carbon nanotube (CNT)-polydimethylsiloxane (PDMS) strain sensors. The process allows the alignment of CNTs within the PDMS elastomer, permitting directional sensing. Aligning CNTs horizontally (HA-CNTs) on the substrate before embedding in the PDMS reduces the number of CNT junctions and introduces scale-like features on the CNT film perpendicular to the tensile strain direction, resulting in improved sensitivity compared to vertically-aligned CNT-(VA-CNT)-PDMS strain sensors under tension. The CNT alignment and the scale-like features modulate the electron conduction pathway, affecting the electrical sensitivity. Resulting GF values are 594 at 15% and 65 at 50% strains for HA-CNT-PDMS and 326 at 25% and 52 at 50% strains for VA-CNT-PDMS sensors. Under compression, VA-CNT-PDMS sensors show more sensitivity to small-scale deformation than HA-CNT-PDMS sensors due to the CNT orientation and the continuous morphology of the film, demonstrating that the sensing ability can be improved by aligning the CNTs in certain directions. Furthermore, mechanical robustness and electromechanical durability are tested for over 6000 cycles up to 50% tensile and compressive strains, with good frequency responses with negligible hysteresis. Finally, both types of sensors are shown to detect small-scale human motions, successfully distinguishing various human motions with reaction and recovery times of as low as 130 ms and 0.5 s, respectively.


Asunto(s)
Dimetilpolisiloxanos/química , Membranas Artificiales , Nanotubos de Carbono/química , Dispositivos Electrónicos Vestibles , Conductividad Eléctrica , Humanos