1.
Yakugaku Zasshi ; 144(5): 577-584, 2024.
Artículo en Japonés | MEDLINE | ID: mdl-38692934

RESUMEN

We conducted a multicenter survey of emergency room nurses to obtain information that would be useful for the establishment of pharmacist services in emergency rooms. Notably, 199 valid responses were obtained from 12 hospitals. The most common expectation from pharmacists in the emergency room was "drug management" (70.9%), followed by "providing information to physicians regarding the patient's medication history" (59.3%), and "auditing of dosage and interaction" (57.3%). The working arrangements that the survey respondents wanted regarding pharmacists in emergency rooms were: 24 h pharmacist (41.7% wanted this arrangement), day-shift pharmacist (24.6% wanted this arrangement), 24 h on-call (17.1% wanted this arrangement), day-shift on-call (5.0% wanted this arrangement), telephone support (11.1% wanted this arrangement), and 0.5% said that there was no need for pharmacists. In the analysis of factors affecting nurse satisfaction, day-shift pharmacist was a significant factor. We hope that the results of this survey will be used as a guide for the development of emergency room pharmacist services tailored to the unique characteristics and actual working conditions of each hospital.


Asunto(s)
Servicio de Urgencia en Hospital , Farmacéuticos , Servicio de Farmacia en Hospital , Encuestas y Cuestionarios , Humanos , Japón , Enfermeras y Enfermeros , Adulto , Femenino , Masculino , Rol Profesional , Persona de Mediana Edad
2.
Int J Cardiol ; 400: 131805, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38272132

RESUMEN

BACKGROUND: The geographical disparity in the pathophysiological pattern of coronary artery disease (CAD) among patients undergoing percutaneous coronary intervention (PCI) is unknown. OBJECTIVES: To elucidate the geographical variance in the pathophysiological characteristics of CAD. METHODS: Physiological indices derived from angiography-based fractional flow reserve pullbacks from patients with chronic coronary syndrome enrolled in the ASET Japan (n = 206) and ASET Brazil (n = 201) studies, which shared the same eligibility criteria, were analysed. The pathophysiological patterns of CAD were characterised using Murray law-based quantitative flow ratio (µQFR)-derived indices acquired from pre-PCI angiograms. The diffuseness of CAD was defined by the µQFR pullback pressure gradient index. RESULTS: Significant functional stenoses pre-PCI (µQFR ≤0.80) were more frequent in ASET Japan compared to ASET Brazil (89.9% vs. 67.5%, p < 0.001), as were rates of a post-PCI µQFR <0.91 (22.1% vs. 12.9%, p = 0.013). In the multivariable analysis, pre-procedural µQFR and diffuse disease were independent factors for predicting a post-PCI µQFR <0.91, which contributed to the different rates of post-PCI µQFR ≥0.91 between the studies. Among vessels with a post-PCI µQFR <0.91, a consistent diffuse pattern of CAD pre- and post-PCI occurred in 78.3% and 76.7% of patients in ASET Japan and Brazil, respectively; only 6.3% (Japan) and 10.0% (Brazil) of vessels had a major residual gradient. Independent risk factors for diffuse disease were diabetes mellitus in ASET Japan, and age and male gender in Brazil. CONCLUSIONS: There was geographic disparity in pre-procedural angiography-based pathophysiological characteristics. The combined pre-procedural physiological assessment of vessel µQFR and diffuseness of CAD may potentially identify patients who will benefit most from PCI.


Asunto(s)
Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Intervención Coronaria Percutánea , Humanos , Masculino , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/epidemiología , Intervención Coronaria Percutánea/efectos adversos , Reserva del Flujo Fraccional Miocárdico/fisiología , Angiografía Coronaria , Resultado del Tratamiento , Vasos Coronarios , Valor Predictivo de las Pruebas
3.
EuroIntervention ; 19(11): e891-e902, 2023 Dec 18.
Artículo en Inglés | MEDLINE | ID: mdl-37960875

RESUMEN

BACKGROUND: Even with intracoronary imaging-guided stent optimisation, suboptimal haemodynamic outcomes post-percutaneous coronary intervention (PCI) can be related to residual lesions in non-stented segments. Preprocedural assessment of pathophysiological coronary artery disease (CAD) patterns could help predict the physiological response to PCI. AIMS: The aim of this study was to assess the relationship between preprocedural pathophysiological haemodynamic patterns and intracoronary imaging findings, as well as their association with physiological outcomes immediately post-PCI. METHODS: Data from 206 patients with chronic coronary syndrome enrolled in the ASET-JAPAN study were analysed. Pathophysiological CAD patterns were characterised using Murray law-based quantitative flow ratio (µQFR)-derived indices acquired from pre-PCI angiograms. The diffuseness of CAD was defined by the pullback pressure gradient (PPG) index. Intracoronary imaging in stented segments after stent optimisation was also analysed. RESULTS: In the multivariable analysis, diffuse disease - defined by the pre-PCI µQFR-PPG index - was an independent factor for predicting a post-PCI µQFR <0.91 (per 0.1 decrease of PPG index, odds ratio 1.57, 95% confidence interval: 1.07-2.34; p=0.022), whereas the stent expansion index (EI) was not associated with a suboptimal post-PCI µQFR. Among vessels with an EI ≥80% and post-PCI µQFR <0.91, 84.0% of those vessels had a diffuse pattern preprocedure. There was no significant difference in EI between vessels with diffuse disease and those with focal disease. The average plaque burden in the stented segment was significantly larger in vessels with a preprocedural diffuse CAD pattern. CONCLUSIONS: A physiological diffuse pattern preprocedure was an independent factor in predicting unfavourable immediate haemodynamic outcomes post-PCI, even after stent optimisation using intracoronary imaging. Preprocedural assessment of CAD patterns could identify patients who are likely to exhibit superior immediate haemodynamic outcomes following PCI.


Asunto(s)
Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Intervención Coronaria Percutánea , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Angiografía Coronaria/métodos , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Vasos Coronarios/patología , Resultado del Tratamiento , Hemodinámica , Valor Predictivo de las Pruebas
4.
Front Cardiovasc Med ; 10: 1161779, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37529710

RESUMEN

Paravalvular leak (PVL) is a shortcoming that can erode the clinical benefits of transcatheter valve replacement (TAVR) and therefore a readily applicable method (aortography) to quantitate PVL objectively and accurately in the interventional suite is appealing to all operators. The ratio between the areas of the time-density curves in the aorta and left ventricular outflow tract (LVOT-AR) defines the regurgitation fraction (RF). This technique has been validated in a mock circulation; a single injection in diastole was further tested in porcine and ovine models. In the clinical setting, LVOT-AR was compared with trans-thoracic and trans-oesophageal echocardiography and cardiac magnetic resonance imaging. LVOT-AR > 17% discriminates mild from moderate aortic regurgitation on echocardiography and confers a poor prognosis in multiple registries, and justifies balloon post-dilatation. The LVOT-AR differentiates the individual performances of many old and novel devices and is being used in ongoing randomized trials and registries.

5.
Circ J ; 87(6): 857-865, 2023 05 25.
Artículo en Inglés | MEDLINE | ID: mdl-36908118

RESUMEN

BACKGROUND: P2Y12 inhibitor monotherapy without aspirin immediately after percutaneous coronary intervention (PCI) has not been tested in East Asian patients, so in this study we aimed to assess the safety and feasibility of reduced dose (3.75 mg/day) prasugrel monotherapy in Japanese patients presenting with chronic coronary syndrome (CCS).Methods and Results: ASET-JAPAN is a prospective, multicenter, single-arm pilot study that completed enrolment of 206 patients from 12 Japanese centers in September 2022. Patients with native de-novo coronary lesions and a SYNTAX score <23 were treated exclusively with biodegradable-polymer platinum-chromium everolimus-eluting stent(s). Patients were loaded with standard dual antiplatelet therapy (DAPT) and following successful PCI and optimal stent deployment, they received low-dose prasugrel (3.75 mg/day) monotherapy for 3 months. The primary ischemic endpoint was a composite of cardiac death, spontaneous target-vessel myocardial infarction, or definite stent thrombosis. The primary bleeding endpoint was Bleeding Academic Research Consortium (BARC) type 3 or 5. At 3-month follow-up, there were no primary bleeding or ischemic events, or any stent thrombosis. CONCLUSIONS: This pilot study showed the safety and feasibility of prasugrel monotherapy in selected low-risk Japanese patients with CCS. This "aspirin-free" strategy may be a safe alternative to traditional DAPT following PCI.


Asunto(s)
Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Clorhidrato de Prasugrel , Humanos , Aspirina , Pueblos del Este de Asia , Everolimus , Hemorragia , Japón , Intervención Coronaria Percutánea/métodos , Proyectos Piloto , Platino (Metal) , Polímeros , Clorhidrato de Prasugrel/uso terapéutico , Estudios Prospectivos
6.
AsiaIntervention ; 9(1): 39-48, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36936091

RESUMEN

The Acetyl Salicylic Elimination Trial (ASET) Japan pilot study is a multicentre, single-arm, open-label, proof-of-concept study with a stopping rule based on the occurrence of definite stent thrombosis. This study aims to demonstrate the feasibility and safety of low-dose prasugrel monotherapy following percutaneous coronary intervention (PCI) in Japanese patients presenting with chronic coronary syndromes (CCS) or non-ST-elevation acute coronary syndromes (NSTE-ACS). Four hundred patients with a SYNTAX score <23 requiring PCI due to CCS or NSTE-ACS will be screened and considered eligible for the study. The enrolment is planned in two phases: 1) 200 patients presenting with CCS, followed by 2) 200 patients presenting with NSTE-ACS. After optimal PCI with implantation of a SYNERGY (Boston Scientific) stent, patients will be enrolled and loaded with prasugrel 20 mg, followed by a maintenance dose of prasugrel 3.75 mg once daily without aspirin continued for 3 months in Phase 1 (CCS patients), and for 12 months in Phase 2 (NSTE-ACS patients). After these follow-up periods, prasugrel will be replaced by standard antiplatelet therapy according to local practice. The primary endpoint is a composite of cardiac death, target vessel myocardial infarction, or definite stent thrombosis after the index procedure. The primary bleeding endpoint is any Bleeding Academic Research Consortium type 3 or 5 bleeding occurring within 3 months of the index PCI for CCS patients, or 12 months for NSTE-ACS patients. The ASET Japan study is designed to demonstrate the feasibility and safety of reduced-dose prasugrel monotherapy after PCI in East Asian patients with acute and chronic coronary syndromes.

7.
PLoS One ; 17(2): e0263246, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35104282

RESUMEN

AIM: To investigate the characteristics of coronary artery bifurcation type (parallel or perpendicular type) using three-dimensional (3D) optical coherence tomography (OCT), and determine the feasibility, reproducibility, assessment time and correlation with bifurcation angles measured by 3D quantitative coronary angiography (QCA). METHODS AND RESULTS: We evaluated 60 lesions at the coronary bifurcation that were treated by main vessel (MV) stenting with kissing balloon inflation (KBI) under OCT/optical frequency domain imaging (OFDI) guidance. Inter- and intra-observer agreement regarding the assessment of 3D bifurcation types were 0.88 and 0.94, respectively. The assessment times of 3D-OCT bifurcation type with OCT and OFDI were within about 30 seconds. 3D-OCT bifurcation types showed the greatest correlation with the distal bifurcation angle assessed by 3D-QCA among the three bifurcation angles (distal bifurcation angle, proximal bifurcation angle and main vessel angle), and the optimal cut-off distal bifurcation angle to predict a perpendicular type bifurcation, as determined by ROC analysis, was 51.0° (AUC 0.773, sensitivity 0.80, specificity 0.67). Based on this cut-off value for the distal bifurcation angle (51°), the diagnostic accuracy for perpendicular type bifurcation in cases with a BA ≥ 51° (n = 34) was 70.6% (24/34) and that of the parallel type bifurcation in cases of BA < 51° (n = 26) was 76.9% (20/26). CONCLUSION: Performing 3D-OCT for assessment of coronary artery bifurcation type is feasible and simple, and can be done in a short time with high reproducibility.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Tomografía de Coherencia Óptica/métodos , Anciano , Angioplastia Coronaria con Balón , Área Bajo la Curva , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Estudios de Factibilidad , Femenino , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Curva ROC , Reproducibilidad de los Resultados , Stents
8.
Circ J ; 86(11): 1748-1755, 2022 10 25.
Artículo en Inglés | MEDLINE | ID: mdl-35135943

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is increasingly being performed in very elderly patients, although its efficacy and validity remain unclear. This study evaluated real-world TAVI outcomes in Japanese nonagenarians with severe aortic stenosis.Methods and Results: This single-center study retrospectively assessed the early and long-term clinical outcomes of TAVI in nonagenarians (n=35) and in patients aged <90 years (group Y; n=171). There were no in-hospital deaths in either group. The device success rate and early safety were comparable between the 2 groups. The 5-year rates of freedom from cardiac events and deaths were equivalent in both groups. The cumulative survival rate at 5 years was non-significantly lower in nonagenarians (32.6% in nonagenarians vs. 57.5% in patients aged <90 years, P=0.49). There were no differences in the 5-year survival between nonagenarians after TAVI and the sex- and age-matched populations (P=0.18). The Cox regression model revealed that lower hemoglobin levels were associated with all-cause mortality (P=0.02), and age ≥90 years was not associated with all-cause mortality. CONCLUSIONS: The early and long-term clinical outcomes of TAVI for selected Japanese nonagenarians were comparable to those in patients aged <90 years. Nonagenarians who underwent TAVI achieved an acceptable prognosis compared to the sex- and age-matched population; thus, TAVI appears to be effective for treating aortic stenosis in Japanese nonagenarians.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Humanos , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Hemoglobinas , Japón , Nonagenarios , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
9.
Heart Vessels ; 37(3): 363-373, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34417846

RESUMEN

A beneficial surrogate marker for evaluating the effect of medical therapy is warranted to avoid deferred lesion revascularization. Similar to coronary artery imaging for monitoring the effects of medical therapy by analyzing plaque regression and stabilization, we hypothesized that evaluation of serial changes in the quantitative flow ratio (QFR) would serve as a surrogate marker of the effects of medical therapy against deferred lesion revascularization. Here, we investigated serial changes in QFR over time after percutaneous coronary intervention in patients who underwent medical therapy as a secondary prevention. Patients with intermediate stenosis in an untreated vessel observed at the baseline (BL) coronary angiography and follow-up (FU) coronary angiography performed 6-18 months after BL angiography were screened in 2 centers. A total of 52 patients were able to analyze both BL and FU QFR. The median QFR was 0.83 (IQR, 0.69, 0.89) at BL and 0.80 (IQR, 0.70, 0.86) at FU. The number of positive ΔQFR and negative ΔQFR were 21 and 31, respectively. The median ΔQFR was 0.05 (IQR, 0.03, 0.09) in positive ΔQFR and - 0.05 (IQR, - 0.07, - 0.03) in negative ΔQFR (p < 0.0001). Univariate and multivariate analyses revealed that LDL-C at FU predicted improvement in the QFR (OR 0.95, 95% confidence interval [0.91, 0.98], P = 0.001). Assessment of serial changes in the QFR may serve as a surrogate marker for the effects of medical therapy in patients with residual intermediate coronary stenosis.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Intervención Coronaria Percutánea , Constricción Patológica , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/cirugía , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Humanos , Intervención Coronaria Percutánea/efectos adversos , Valor Predictivo de las Pruebas
10.
J Pharm Health Care Sci ; 7(1): 39, 2021 Nov 03.
Artículo en Inglés | MEDLINE | ID: mdl-34727989

RESUMEN

BACKGROUND: Bucolome is a non-steroidal anti-inflammatory drug and uricosuric agent, currently used only in Japan. It is known to induce drug interactions by inhibiting cytochrome P450 (CYP) 2C9. It is often used to enhance the anticoagulant effect of warfarin by utilizing its drug interactions. There are only a few reports on drug interactions of bucolome and the mechanism remain poorly understood. CASE PRESENTATION: An 81-year-old woman with a history of type 2 diabetes mellitus was taking glimepiride 2 mg/day and voglibose 0.6 mg/day. After hospitalization, the patient underwent surgical aortic valve replacement surgery (day 0). Glimepiride and voglibose were resumed on the second postoperative day (day 2), and warfarin was started to prevent thromboembolism. Since the prothrombin time-international normalized ratio on day 9 was low at 1.24, 300 mg/day of bucolome was added to enhance the effect of warfarin. A gradual decrease in blood glucose levels was observed from the day after bucolome administration was initiated. Hypoglycemia in the 56-57 mg/dL range occurred before lunch and dinner on the 6th day (day 14) of bucolome administration, due to which voglibose was discontinued. Hypoglycemia below 70 mg/dL was not observed thereafter, and the general condition of the patient was stable. CONCLUSIONS: Based on the clinical course and literature review, we believe that hypoglycemia in the present case was due to a drug interaction, caused by inhibition of CYP2C9 by bucolome and competitive inhibition of CYP2C9 by warfarin, which affected the pharmacokinetics of glimepiride. The possibility of hypoglycemia due to drug interactions should be considered by physicians, when bucolome is included to enhance the effect of warfarin, in patients taking glimepiride.

11.
JACC Cardiovasc Interv ; 13(11): 1303-1311, 2020 06 08.
Artículo en Inglés | MEDLINE | ID: mdl-32499020

RESUMEN

OBJECTIVES: The aim of this study was to assess acute regurgitation following transcatheter aortic valve replacement, comparing different implanted transcatheter heart valves. BACKGROUND: Regurgitation following transcatheter aortic valve replacement influences all-cause mortality. Thus far, no quantitative comparison of regurgitation among multiple commercially available transcatheter heart valves has been performed. METHODS: Aortograms from a multicenter cohort of consecutive 3,976 transcatheter aortic valve replacements were evaluated in this pooled analysis. A total of 2,258 (58.3%) were considered analyzable by an independent academic core laboratory using video densitometry. Results of quantitative regurgitation are shown as percentages. The valves evaluated were the ACURATE (n = 115), Centera (n = 11), CoreValve (n = 532), Direct Flow Medical (n = 21), Evolut PRO (n = 95), Evolut R (n = 295), Inovare (n = 4), Lotus (n = 546), Lotus Edge (n = 3), SAPIEN XT (n = 239), and SAPIEN 3 (n = 397). For the main analysis, only valves with more than 50 procedures (7 types) were used. RESULTS: The Lotus valve had the lowest mean regurgitation (3.5 ± 4.4%), followed by Evolut PRO (7.4 ± 6.5%), SAPIEN 3 (7.6 ± 7.1%), Evolut R (7.9 ± 7.4%), SAPIEN XT (8.8 ± 7.5%), ACURATE (9.6 ± 9.2%) and CoreValve (13.7 ± 10.7%) (analysis of variance p < 0.001). The only valves that statistically differed from all their counterparts were Lotus (as the lowest regurgitation) and CoreValve (the highest). The proportion of patients presenting with moderate or severe regurgitation followed the same ranking order: Lotus (2.2%), Evolut PRO (5.3%), SAPIEN 3 (8.3%), Evolut R (8.8%), SAPIEN XT (10.9%), ACURATE (11.3%), and CoreValve (30.1%) (chi-square p < 0.001). CONCLUSIONS: In this pooled analysis stemming from daily clinical practice, the Lotus valve was shown to have the best immediate sealing. This analysis reflects the objective evaluation of regurgitation by an academic core laboratory (nonsponsored) in a real-world cohort of patients using a quantitative technique.


Asunto(s)
Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Estudios de Factibilidad , Humanos , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
13.
Cardiovasc Interv Ther ; 35(4): 336-342, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31707692

RESUMEN

The three-dimensional reconstruction of optical coherence tomography and optical frequency domain imaging (3D-OCT/OFDI) helps optimize bifurcation percutaneous coronary interventions (PCIs) with side branch (SB) dilatation by identifying the optimal rewiring position. 3D-OCT/OFDI's diagnostic performance for assessing the rewiring position into a jailed SB is unknown. We retrospectively evaluated the diagnostic performances of a conventional (ver. 1.1) and a new (ver. 1.2) online 3D-OFDI reconstruction system based on an offline 3D reconstruction system's performance. We analyzed 45 patients' 52 OFDI pullbacks with main vessel stenting followed by rewiring into a jailed SB for coronary bifurcation lesions. We counted the undetected stent struts in the polygon of confluence as the stent detection performance. We assessed the diagnostic agreement regarding the rewiring position into a jailed SB by the three 3D reconstruction systems. The percentage of undetected struts and the diagnostic agreement of ver.1.2 were significantly better than those of ver.1.1 [5.1 ± 5.1% vs. 30.2 ± 14.2%; p < 0.0001, and 94.2% (49/52) vs. 76.9% (40/52); p = 0.0120]. The new online 3D-OFDI reconstruction system provides better diagnostic performance than the conventional online system for assessing the rewiring position into a jailed SB.


Asunto(s)
Angioplastia Coronaria con Balón/métodos , Enfermedad de la Arteria Coronaria/terapia , Imagenología Tridimensional , Programas Informáticos , Stents , Tomografía de Coherencia Óptica , Anciano , Anciano de 80 o más Años , Angioplastia Coronaria con Balón/instrumentación , Enfermedad de la Arteria Coronaria/cirugía , Femenino , Humanos , Imagenología Tridimensional/métodos , Internet , Masculino , Persona de Mediana Edad , Sistemas en Línea , Intervención Coronaria Percutánea/instrumentación , Intervención Coronaria Percutánea/métodos , Estudios Retrospectivos , Tomografía de Coherencia Óptica/métodos
14.
EuroIntervention ; 15(5): 420-426, 2019 Aug 29.
Artículo en Inglés | MEDLINE | ID: mdl-31147307

RESUMEN

AIMS: Quantitative aortography using videodensitometry is a valuable tool for quantifying paravalvular regurgitation after TAVI, especially in the minimalist approach - without general anaesthesia. However, retrospective assessment of aortograms showed moderate feasibility of assessment. We sought to determine the prospective feasibility of quantitative aortography after a protocol of acquisition. METHODS AND RESULTS: This was a multicentre registry in Japan, Canada, the Netherlands and Germany including consecutive patients with Heart Team indication to undergo TAVI over a median period of 12 months. Operators performed final aortograms according to a pre-planned projection (either by CT or visually - Teng's rule). An independent core laboratory (Cardialysis) analysed all images for feasibility and for regurgitation assessment. From the four centres included in the present analysis, a total of 354 patients underwent TAVI following the acquisition protocol and all the aortograms were analysed by the core lab. The analyses were feasible in 95.5% (95% confidence interval [CI]: 93.2% to 97.5%) of the cases. This rate of analysable assessment was significantly higher than the feasibility in previous validation studies, such as in the RESPOND population (95.5% vs. 57.5%, p<0.0001). No differences were observed among different planning strategies (CT 96.5% vs. Teng's rule 93%, p=0.159; or Circle 98.5% vs. 3mensio 95.8% vs. Teng's rule 93%, p=0.247). CONCLUSIONS: ASSESS-REGURGE showed a high feasibility of assessment of regurgitation with quantitative aortography with protocoled acquisition. This may be of great importance for quantifying regurgitation in TAVI procedures (optimisation, guidance of post-dilatation), and in future clinical trials, in order to address sealing features of novel devices for TAVI objectively. ClinicalTrials.gov Identifier: NCT03644784.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica , Insuficiencia de la Válvula Aórtica/cirugía , Aortografía , Humanos , Valor Predictivo de las Pruebas , Estudios Prospectivos , Sistema de Registros , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
15.
Cardiology ; 142(4): 195-202, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31137022

RESUMEN

BACKGROUND: Tachycardia worsens cardiac performance in acute decompensated heart failure (ADHF). We investigated whether heart rate (HR) optimization by landiolol, an ultra-short-acting ß1-selective blocker, in combination with milrinone improved cardiac function in patients with ADHF and rapid atrial fibrillation (AF). METHODS AND RESULTS: We enrolled9 ADHF patients (New York Heart Association classification IV; HR, 138 ± 18 bpm; left ventricular [LV] ejection fraction, 28 ± 8%; cardiac index [CI], 2.1 ± 0.3 L/min-1/m-2; pulmonary capillary wedge pressure [PCWP], 24 ± 3 mm Hg), whose HRs could not be reduced using standard treatments, including diuretics, vasodilators, and milrinone. Landiolol (1.5-6.0 µg/kg-1/min-1, intravenous) was added to milrinone treatment to study its effect on hemodynamics. The addition of landiolol (1.5 µg/kg-1/min-1) significantly reduced HR by 11% without changing systolic blood pressure (BP) and resulted in a significant decrease in PCWP and a significant increase in stroke volume index (SVI), suggesting that HR reduction restores incomplete LV relaxation. Administration of more than 3.0 µg/kg-1/min-1 of landiolol decreased BP, CI, and SVI. CONCLUSION: The addition of landiolol at doses of <3.0 µg/kg/min to milrinone improved cardiac function in decompensated chronic heart failure with rapid atrial fibrillation by selectively reducing HR.


Asunto(s)
Antagonistas Adrenérgicos beta/uso terapéutico , Fibrilación Atrial/tratamiento farmacológico , Cardiotónicos/uso terapéutico , Insuficiencia Cardíaca/tratamiento farmacológico , Milrinona/uso terapéutico , Morfolinas/uso terapéutico , Urea/análogos & derivados , Anciano , Anciano de 80 o más Años , Relación Dosis-Respuesta a Droga , Quimioterapia Combinada , Femenino , Hemodinámica/efectos de los fármacos , Humanos , Japón , Masculino , Estudios Prospectivos , Taquicardia , Resultado del Tratamiento , Urea/uso terapéutico
16.
Arq Bras Cardiol ; 111(2): 193-202, 2018 Aug.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-30183986

RESUMEN

BACKGROUND: Balloon post-dilatation (BPD) is often needed for optimizing transcatheter heart valve (THV) implantation, since paravalvular leak (PVL) after transcatheter aortic valve implantation is associated with poor outcome and mortality. Quantitative assessment of PVL severity before and after BPD is mandatory to properly assess PVL, thus improving implantation results and outcomes. OBJECTIVE: To investigate a quantitative angiographic assessment of aortic regurgitation (AR) by videodensitometry before and after BPD. METHODS: Videodensitometric-AR assessments (VD-AR) before and after BPD were analysed in 61 cases. RESULTS: VD-AR decreased significantly from 24.0[18.0-30.5]% to 12.0[5.5-19.0]% (p < 0.001, a two-tailed p < 0.05 defined the statistical significance). The relative delta of VD-AR after BPD ranged from -100% (improvement) to +40% (deterioration) and its median value was -46.2%. The frequency of improvement, no change, and deterioration were 70% (n = 43), 25% (n = 15) and 5% (n = 3), respectively. Significant AR (VD-AR > 17%) was observed in 47 patients (77%) before and in 19 patients (31%) after BPD. CONCLUSIONS: VD-AR after THV implantation provides a quantitative assessment of post-TAVI regurgitation and can help in the decision-making process on performing BPD and in determining its efficacy.


Asunto(s)
Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano de 80 o más Años , Aortografía , Densitometría , Femenino , Humanos , Masculino , Complicaciones Posoperatorias/diagnóstico por imagen , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Grabación en Video
17.
Catheter. cardiovasc. interv ; 92(5): 945-953, Nov. 2018. tab, ilus
Artículo en Inglés | Sec. Est. Saúde SP, CONASS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1223467

RESUMEN

OBJECTIVES: To explore the rate, the determinants of success, and the hemodynamic impact of balloon postdilatation (BPD) of self-expanding transcatheter heart valves (SE-THVs) Background: BPD is commonly used to optimize valve expansion and reduce paravalvular leakage (PVL) after transcatheter aortic valve implantation (TAVI) without clearly knowing its hemodynamic benefits. METHODS: Patients (n 5 307) who received a SE-THV were stratified according to whether a BPD was performed or not. Patients who received BPD were stratified according to the severity of PVL remaining after BPD into two groups: Successful BPD ( mild PVL 1 BPD) and Failed BPD (moderate-severe PVL 1 BPD). RESULTS: BPD was performed in 121 patients (39.4%) and was successful in 106 patients (87.6% of attempts). A ratio of the postdilatation balloon diameter to the annulus diameter 0.95 was an independent predictor of BPD failure (OR: 10.72 [2.02-56.76], P 5 .005). Peak transvalvular pressure gradient (PG) was lower in the Successful BPD group (14[12-22] mm Hg) than in the Failed BPD group (18[16-23] mm Hg, P 5 .029), and did not rise in either group during follow-up (median [IQR], 364[161-739] days). CONCLUSION: BPD was performed in 39% of patients who received a SE-THV, and was successful in the majority of attempts. BPD failure was more likely in patients with a small postdilatation balloon-to-annulus diameter ratio. Effective BPD improved THV hemodynamic performance, and this was maintained in the intermediate-term post-TAVI.


Asunto(s)
Reemplazo de la Válvula Aórtica Transcatéter , Hemodinámica , Válvula Aórtica
18.
Arq. bras. cardiol ; 111(2): 193-202, Aug. 2018. tab, graf
Artículo en Inglés, Portugués | LILACS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-950218

RESUMEN

Abstract Background: Balloon post-dilatation (BPD) is often needed for optimizing transcatheter heart valve (THV) implantation, since paravalvular leak (PVL) after transcatheter aortic valve implantation is associated with poor outcome and mortality. Quantitative assessment of PVL severity before and after BPD is mandatory to properly assess PVL, thus improving implantation results and outcomes. Objective: To investigate a quantitative angiographic assessment of aortic regurgitation (AR) by videodensitometry before and after BPD. Methods: Videodensitometric-AR assessments (VD-AR) before and after BPD were analysed in 61 cases. Results: VD-AR decreased significantly from 24.0[18.0-30.5]% to 12.0[5.5-19.0]% (p < 0.001, a two-tailed p < 0.05 defined the statistical significance). The relative delta of VD-AR after BPD ranged from -100% (improvement) to +40% (deterioration) and its median value was -46.2%. The frequency of improvement, no change, and deterioration were 70% (n = 43), 25% (n = 15) and 5% (n = 3), respectively. Significant AR (VD-AR > 17%) was observed in 47 patients (77%) before and in 19 patients (31%) after BPD. Conclusions: VD-AR after THV implantation provides a quantitative assessment of post-TAVI regurgitation and can help in the decision-making process on performing BPD and in determining its efficacy.


Resumo Fundamento: A pós-dilatação com balão (PDB) é normalmente necessária para otimização do implante da válvula cardíaca transcateter (THV), uma vez que o "escape" ou leak paravalvar (PVL) após implante de valva aórtica transcateter está associada com desfecho ruim e mortalidade. A avaliação quantitativa da gravidade do PVL antes e após a PDB é mandatória para se avaliar adequadamente o PVL e, assim, melhorar os resultados e os desfechos do implante. Objetivo: Investigar uma avalição angiográfica quantitativa da regurgitação aórtica (RA) por videodensitometria (VD-RA) antes e após a PDB. Métodos: Resultados da VD-RA antes e após a PDB foram analisados em 61 casos. Resultados Houve diminuição significativa da VD-RA de 24,0(18,0-30,5)% para 12,0(5,5-19,0)% (p < 0,001; p < 0,05 bilateral foi definido como significância estatística). O delta relativo de VD-RA após a PDB variou de -100% (melhora) a +40% (piora) e o valor mediano foi -46,2%. As frequências de melhora, ausência de mudança, e piora foram 70% (n = 43), 25% (n = 15) e 5% (n = 3), respectivamente. Observou-se RA significativo (VD-RA > 17%) em 47 pacientes (77%) antes e em 19 pacientes (31%) após a PDB. Conclusões: A VD-RA após o implante de THV possibilita a avaliação quantitativa da regurgitação pós-TAVI, e pode auxiliar na tomada de decisão quanto à realização ou não da PDB, bem como na avaliação de sua eficácia.


Asunto(s)
Humanos , Masculino , Femenino , Anciano de 80 o más Años , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Reemplazo de la Válvula Aórtica Transcatéter , Complicaciones Posoperatorias/diagnóstico por imagen , Grabación en Video , Índice de Severidad de la Enfermedad , Aortografía , Densitometría , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
19.
Circ J ; 82(9): 2317-2325, 2018 08 24.
Artículo en Inglés | MEDLINE | ID: mdl-29973472

RESUMEN

BACKGROUND: We investigated the relationship between intraprocedural angiographic and echocardiographic AR severity after TAVI, and the clinical robustness of angiographic assessment. Methods and Results: In 74 consecutive patients, the echocardiographic circumferential extent (CE) of the paravalvular regurgitant jet was retrospectively measured and graded based on the VARC-2 cut-points; and angiographic post-TAVI AR was retrospectively quantified using contrast videodensitometry (VD) software that calculates the ratio of the contrast time-density integral in the LV outflow tract to that in the ascending aorta (LVOT-AR). Seventy-four echocardiograms immediately after TAVI were analyzable, while 51 aortograms were analyzable for VD. These 51 echocardiograms and VD were evaluated. Median LVOT-AR across the echocardiographic AR grades was as follows: none-trace, 0.07 (IQR, 0.05-0.11); mild, 0.12 (IQR, 0.09-0.15); and moderate, 0.17 (IQR, 0.15-0.22; P<0.05 for none-trace vs. mild, and mild vs. moderate). LVOT-AR strongly correlated with %CE (r=0.72, P<0.0001). At 1 year, the rate of the composite end-point of all-cause death or HF re-hospitalization was significantly higher in >mild AR patients compared with no-mild AR on intra-procedural echocardiography (41.5% vs. 12.4%, P=0.03) as well as in patients with LVOT-AR >0.17 compared with LVOT-AR ≤0.17 (59.5% vs. 16.6%, P=0.03). CONCLUSIONS: VD (LVOT-AR) has good intra-procedural inter-technique consistency and clinical robustness. Greater than mild post-TAVI AR, but not mild post-TAVI AR, is associated with late mortality.


Asunto(s)
Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Aortografía/métodos , Ecocardiografía Transesofágica/métodos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano de 80 o más Años , Insuficiencia de la Válvula Aórtica/mortalidad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Readmisión del Paciente , Pronóstico , Curva ROC , Reproducibilidad de los Resultados , Estudios Retrospectivos
20.
Circ J ; 82(7): 1943-1950, 2018 06 25.
Artículo en Inglés | MEDLINE | ID: mdl-29760325

RESUMEN

BACKGROUND: The clinical robustness of contrast-videodensitometric (VD) assessment of aortic regurgitation (AR) after transcatheter aortic valve implantation (TAVI) has been demonstrated. Correct acquisition of aortic root angiography for VD assessment, however, is hampered by the opacified descending aorta and by individual anatomic peculiarities. The aim of this study was to use preprocedural multi-slice computed tomography (MSCT) to optimize the angiographic projection in order to improve the feasibility of VD assessment.Methods and Results:In 92 consecutive patients, post-TAVI AR (i.e., left ventricular outflow tract [LVOT] AR) was assessed on aortic root angiograms using VD software. The patients were divided into 2 groups: The first group of 54 patients was investigated prior to the introduction of the standardized acquisition protocol; the second group of 38 consecutive patients after implementation of the standardized acquisition protocol, involving MSCT planning of the optimal angiographic projection. Optimal projection planning has dramatically improved the feasibility of VD assessment from 57.4% prior to the standardized acquisition protocol, to 100% after the protocol was implemented. In 69 analyzable aortograms (69/92; 75%), LVOT-AR ranged from 3% to 28% with a median of 12%. Inter-observer agreement was high (mean difference±SD, 1±2%), and the 2 observers' measurements were highly correlated (r=0.94, P<0.0001). CONCLUSIONS: Introduction of computed tomography-guided angiographic image acquisition has significantly improved the analyzability of the angiographic VD assessment of post-TAVI AR.


Asunto(s)
Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Aortografía/métodos , Tomografía Computarizada por Rayos X/métodos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Insuficiencia de la Válvula Aórtica/diagnóstico , Humanos , Variaciones Dependientes del Observador , Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...