Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Plast Aesthet Nurs (Phila) ; 44(3): 213-219, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39028477

RESUMEN

Hyaluronic acid (HA)-based injectables continue to grow in popularity and are used worldwide to improve facial changes associated with aging. Profhilo® Structura (IBSA Farmaceutici Italia, Lodi, Italy) is a novel HA-based product that uses nano hybrid complex of hyaluronic acid (NAHYCO)® technology to create hybrid cooperative complexes consisting of high and low molecular weight HA. Profhilo® Structura's high concentration (45 mg of total HA) and rheological properties (ie, viscosity [resistance to flow] and elasticity [stickiness]) have been specially formulated to restore facial adipose tissue. Because of their early involvement in the facial aging process, the superficial medial and lateral-temporal cheek fat compartments are good candidates for treatment. However, recommendations and guidelines are necessary to ensure that treatment is safe and effective. Three experts were invited to IBSA Farmaceutici Italia Srl to discuss clinical rationale, optimal injection techniques, and clinical outcomes for treating the superficial medial and lateral-temporal cheek fat compartments with Profhilo® Structura. These techniques were developed using patients presenting with either initial hypotrophy of fat compartments within the preauricular area (ie, sinkers) or jowl sagging due to hypotrophy within the preauricular and zygomatic areas (ie, saggers). Targeting these areas using the optimal injection site can maximize product diffusion and minimize the risk for vascular compromise. Targeting these areas also leads to lateral tightening and lipolifting effects due to adipose tissue restoration. The experts agreed that Profhilo® Structura is currently the first and only HA-based injectable treatment that can integrate and restore the adipose tissue in these affected fat compartments.


Asunto(s)
Ácido Hialurónico , Humanos , Ácido Hialurónico/administración & dosificación , Ácido Hialurónico/uso terapéutico , Técnicas Cosméticas , Tejido Adiposo , Envejecimiento de la Piel/efectos de los fármacos , Envejecimiento de la Piel/fisiología , Cara
2.
Philos Ethics Humanit Med ; 19(1): 1, 2024 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-38317236

RESUMEN

This article addresses some critical aspects of the relationship between aesthetic medicine (AM) and ethics and proposes a possible deontological ethical line to pursue based on current practices. The role of AM has always been controversial and suffers from unclear practical and moral boundaries, even within academic settings, since it aims to improve the appearance of individuals, not to cure a disease. Today, it is essential and pertinent to discuss these issues, as AM specialists are dealing with a growing and increasingly demanding patient population that has undergone profound evolution in recent years. Current challenges within the field of AM include a lack of global uniformity concerning the education of AM specialists, an increasing number of physicians practicing AM with diverse training backgrounds, the spread of AM being practiced outside of medical practice or hospital settings, and the influence of social media where the success is modelled and dictated by the identification of a youthful appearance). By the field of action enriched by technologies that aim not only at enhancement per se but also at the preservation and regeneration of tissues, it is necessary to establish an active multidisciplinary discussion on the definition of shared ethical limits. This discussion would allow AM to fully reclaim its identity as a specialty that aims to improve patient well-being whilst maintaining respect for patient aesthetic harmony, the expertise of specialists who practice AM, the essential role of safety, and awareness of the importance of a confidential doctor-patient relationship.


Asunto(s)
Medicina , Médicos , Humanos , Relaciones Médico-Paciente , Estética , Atención Dirigida al Paciente
3.
Clin Cosmet Investig Dermatol ; 14: 1465-1471, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34675583

RESUMEN

OBJECTIVE: To describe the development and validation of the 5-grade photographic IBSA inner upper arm scale. METHODS: From 2 real-life pictures, a scale made up of 5 morphed images showing increasing severity of inner upper arm laxity was created. For validation, a set of 50 images (half of which real and the other morphed) was developed and sent to 5 trained physicians in two rounds 30 days apart. Raters' task was to make a selection of each image according to the given scale. Inter-rater and intra-rater reliability were evaluated in both rounds. RESULTS: As to intra-rater reliability, single-rater kappa scores between 0.74 and 1.00 and a global kappa score of 0.846 were observed, while inter-rater agreement was calculated with intra-class correlation coefficient reporting scores higher than 0.91, which indicate excellent reliability. CONCLUSION: IBSA inner upper arm laxity scale proved to be a validated and reliable tool.

4.
Clin Cosmet Investig Dermatol ; 14: 349-354, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33854352

RESUMEN

OBJECTIVE: To describe the development and validation of the 5-grade photographic IBSA Neck Laxity Scale. METHODS: The scale was developed from 2 real images, which led to the creation of 5 morphed images, representing different degrees of severity of laxity of the neck. For validation, a set of 50 images (25 real and 25 morphed) was created and sent for evaluation to 6 trained raters (physicians) in 2 rounds, 1 month apart. Raters had to assess each image according to the 5-image scale. Inter-rater and intra-rater reliability in both rounds was evaluated. RESULTS: As to intra-rater reliability, single rater kappa scores between 0.69 and 0.87, and a global kappa score of 0.78 were observed. Inter-rater agreement was measured by means of the intra-class correlation coefficient and scores higher than 0.85 were reported, indicating excellent reliability. CONCLUSION: IBSA Neck Laxity Scale is a validated and reliable scale.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA