Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Arthrosc Sports Med Rehabil ; 6(3): 100930, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-39006778

RESUMEN

Purpose: To report the clinical outcomes and reoperation rates of arthroscopic and endoscopic iliopsoas release at short-term follow-up after ipsilateral total hip arthroplasty (THA) at 2 separate medical institutions and to evaluate whether demographic and radiographic parameters are associated with postoperative patient-reported outcomes (PROs). Methods: Patients with iliopsoas tendinitis in the setting of prior THA who underwent arthroscopic iliopsoas fractional lengthening from 1988 to 2023 at 2 academic institutions were reviewed. Patients were included if they had 12 months of follow-up and underwent evaluation of preoperative anterior acetabular component overhang, surgery satisfaction, postoperative subjective hip flexion strength and anterior groin pain improvement, modified Harris Hip Score, Single Assessment Numeric Evaluation score, Tegner activity scale score, visual analog scale (VAS) score, and revision hip arthroplasty. Results: Sixty hips in 58 patients (19 male and 39 female patients) were followed up for a mean of 39.3 months (range, 12.0-105.9 months) postoperatively. Of the patients, 77% reported feeling "much better" or "slightly better," 75% reported improved anterior groin pain, and 60% reported improved subjective hip flexion strength. The surgery satisfaction rating was 7.2 ± 3.3 (scale of 0 to 10). The mean postoperative modified Harris Hip Score, VAS score for pain at rest, VAS score for pain with use, and Single Assessment Numeric Evaluation score were 73.9 ± 19.4, 1.3 ± 2.4, 3.8 ± 2.9, and 71.9 ± 21.9, respectively. Preoperative anterior acetabular component overhang was 3.3 ± 6.5 mm and did not significantly correlate with postoperative PROs (P ≥ .45). The Tegner score improved from 2.5 ± 1.7 preoperatively to 2.9 ± 1.4 postoperatively (P = .0253). Three patients underwent revision arthroplasty at a mean of 25.3 months (range, 11.6-40.4 months) postoperatively, with an acetabular component revision rate of 3.3%. Conclusions: Satisfactory outcomes and low revision arthroplasty rates were observed in patients undergoing arthroscopic iliopsoas lengthening after THA. There was no statistically significant relation between anterior acetabular component overhang and final PROs. Level of Evidence: Level IV, therapeutic case series.

2.
Arthroplast Today ; 27: 101396, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-39071822

RESUMEN

Hip and knee arthroplasty are high-volume procedures undergoing rapid growth. The large volume of procedures generates a vast amount of data available for next-generation analytics. Techniques in the field of artificial intelligence (AI) can assist in large-scale pattern recognition and lead to clinical insights. AI methodologies have become more prevalent in orthopaedic research. This review will first describe an overview of AI in the medical field, followed by a description of the 3 arthroplasty research areas in which AI is commonly used (risk modeling, automated radiographic measurements, arthroplasty registry construction). Finally, we will discuss the next frontier of AI research focusing on model deployment and uncertainty quantification.

3.
J Clin Anesth ; 97: 111534, 2024 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-38943851

RESUMEN

STUDY OBJECTIVE: Describe dosing of local anesthetic when both a periarticular injection (PAI) and peripheral nerve block (PNB) are utilized for knee arthroplasty analgesia, and compare the dosing of local to suggested maximum dosing, and look for evidence of local anesthetic systemic toxicity (LAST). DESIGN: A single center retrospective cohort study between May 2018 and November 2022. SETTING: A major academic hospital. PATIENTS: Patients who had both a PAI and PNB while undergoing primary, revision, total, partial, unilateral, or bilateral knee arthroplasty. INTERVENTIONS: None. MEASUREMENTS: Calculate the dose of local anesthetic given via PAI, PNB, and both routes combined as based on lean body weight and compare that to the suggested maximum dosing. Look for medications, clinical interventions, and critical event notes suggestive of a LAST event. MAIN RESULTS: There were 4527 knee arthroplasties where both a PAI and PNB were performed during the study period. When combining PAI and PNB doses, >75% of patients received more than the suggested maximum dose of 3 mg/kg lean body weight. The median local anesthetic dosing over the study period, 4.4 mg/kg (IQR 3.5,5.9), was 147% of the suggested maximum dose (IQR 117,197). There was no conclusive evidence of LAST among any of the patients in the study. CONCLUSIONS: Over the course of our study, we had 4527 knee arthroplasties with a median PAI and PNB local anesthetic dose that was 147% of the suggested maximum without any clear clinical evidence of a LAST event.

4.
Artículo en Inglés | MEDLINE | ID: mdl-38874764

RESUMEN

BACKGROUND: Achieving adequate alignment has traditionally been an important goal in total knee arthroplasty to achieve long-term implant survival. While accelerometer-based hand-held navigation systems (ABN) has been introduced as a way to achieve alignment, there is a limited body of evidence on its accuracy, especially in patients under 65 years with differing etiologies for knee arthritis. This study aimed to assess the precision of a specific ABN system in restoring the mechanical axis and report surgical variables and complications, with particular attention to younger patients. METHODS: We conducted a retrospective review of 310 primary TKA performed with ABN from May 2016 to February 2021. The mean patient age was 67.4 (SD 8.9) years, with 43% under 65 years and mean body mass index of 33.2 (SD 6.8). The average surgical time was 96.8 min (57-171) and the average follow-up was 3.3 years (1.9-6.7). Data regarding length of stay, pain, range of motion (ROM), complications, and reinterventions were collected from the institutional joint arthroplasty registry and the medical records. Preoperative mechanical axis measurements and postoperative radiological data, including mechanical axis, component alignment and mechanical alignment outliers were analyzed. RESULTS: The mean preoperative mechanical axis was 175.4° (SD 7.6), with 248 knees (80%) in preoperative varus. The mean postoperative mechanical axis was 179.5° (SD 1.96) with 98% of knees falling within ± 3° of the neutral mechanical axis. Only 6 knees (2 varus, 4 valgus) fell outside the ± 3° range. And 3 knees (1 varus, 2 valgus) fell outside the ± 5° range. In the sagittal plane, 296 knees (95.5%) knees were within ± 3° of goal of 3 degrees of femoral flexion and 302 (97.4%) knees were within ± 2° of goal 1° of slope for tibial component. Far outliers (alignment outside ± 5° of targeted position) were found in 3 knees. Factors such as posttraumatic arthrosis, previous surgery, presence of retained hardware, and age below 65 years were not associated with increase in alignment outliers and far outliers. No complications related to the navigation system were observed. There were 22 complications and 20 reoperations, including 2 revisions for periprosthetic joint infection and 1 revision for flexion instability. Patients that required knee manipulation achieved an ultimate flexion of 110° (SD 14.1). CONCLUSIONS: The ABN system proved to be user-friendly and accurate in reducing alignment outliers in both coronal and sagittal planes in all patient populations. It offers a straightforward navigation solution while preserving surgeon autonomy and the use of traditional surgical tools. These findings advocate for the integration of this navigation system as a valuable tool to enhance the precision of TKA surgery in all patient groups.

5.
J Bone Joint Surg Am ; 2024 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-38875316

RESUMEN

BACKGROUND: Porous metaphyseal cones are frequently utilized during revision total knee arthroplasty (TKA) procedures. The purpose of the present study was to evaluate 3D-printed metaphyseal cones used for revision TKA, with specific emphasis on implant survivorship, radiographic appearance, and clinical outcomes after short-term follow-up. METHODS: We identified 740 cones (498 tibial, 242 femoral) that had been inserted during 533 revision TKA procedures that had been performed at a single tertiary care academic institution. Aseptic loosening (n = 199), periprosthetic joint infection (PJI) (n = 183), and instability (n = 84) were the most common reasons for the index revision. Type-2B or 3 bone loss was present in 67% of the knees. The mean age was 66 years, the mean body mass index was 34 kg/m 2 , and 55% of the patients were female. Serial radiographs were reviewed. The mean duration of follow-up was 4 years. RESULTS: The 5-year cumulative incidence of cone revision for aseptic loosening was 1% (95% confidence interval [CI], 0% to 3%). The 5-year cumulative incidence of any cone revision or removal was 6% (95% CI, 4% to 9%). In total, 37 cones (19 femoral, 18 tibial) were revised, with PJI (n = 23; 14 recurrent), periprosthetic femoral fracture (n = 3), arthrofibrosis (n = 3), and aseptic loosening of the femoral component and femoral cone (n = 3) as the most common reasons for cone revision. The 5-year cumulative incidence of any TKA re-revision was 14% (95% CI, 11% to 18%). There were a total of 67 re-revisions, with PJI (n = 38), persistent drainage (n = 6), and extensor mechanism disruption (n = 3) being the most common reasons. Radiographically, 2 unrevised femoral cones and 1 unrevised tibial cone appeared to be possibly loose; all 3 cones were in knees with distal femoral replacements or hinged constructs. CONCLUSIONS: This large series showed that 3D-printed titanium metaphyseal cones were very durable at short-term follow-up, with a 5-year cumulative incidence of cone revision for aseptic loosening of 1%. PJI was the most common reason for cone revision and any revision. LEVEL OF EVIDENCE: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.

7.
J Arthroplasty ; 39(9S1): S97-S100, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38735544

RESUMEN

BACKGROUND: Our previously reported randomized clinical trial of direct anterior approach (DAA) versus mini-posterior approach (MPA) total hip arthroplasty showed slightly faster initial recovery for patients who had a DAA and no differences in complications or clinical or radiographic outcomes beyond 8 weeks. The aims of the current study were to determine if early advantages of DAA led to meaningful clinical differences beyond 5 years and to identify differences in midterm complications. METHODS: Of the 101 original patients, 93 were eligible for follow-up at a mean of 7.5 years (range, 2.1 to 10). Clinical outcomes were compared with Harris Hip, 12-Item Short Form Health Survey, and Hip Disability and Osteoarthritis Outcomes Scores (HOOS) scores and subscores, complications, reoperations, and revisions. RESULTS: Harris Hip scores were similar (95.3 ± 6.0 versus 93.5 ± 10.3 for DAA and MPA, respectively, P = .79). The 12-Item Short Form Health Survey physical and mental scores were similar (46.2 ± 9.3 versus 46.2 ± 10.6, P = .79, and 52.3 ± 7.1 versus 55.2 ± 4.5, P = .07 in the DAA and MPA groups, respectively). The HOOS scores were similar (97.4 ± 7.9 versus 96.3 ± 6.7 for DAA and MPA, respectively, P = .07). The HOOS quality of life subscores were 96.9 ± 10.8 versus 92.3 ± 16.0 for DAA and MPA, respectively (P = .046). No clinical outcome met the minimally clinically important difference. There were 4 surgical complications in the DAA group (1 femoral loosening requiring revision, 1 dislocation treated closed, and 2 wound dehiscences requiring debridement), and 6 surgical complications in the MPA group (3 dislocations, 2 treated closed, and 1 revised to dual mobility; 2 intraoperative fractures treated with a cable; and 1 wound dehiscence treated nonoperatively). CONCLUSIONS: At a mean of 7.5 years, this randomized clinical trial demonstrated no clinically meaningful differences in outcomes, complications, reoperations, or revisions between DAA and MPA total hip arthroplasty. LEVEL OF EVIDENCE: IV.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Osteoartritis de la Cadera , Reoperación , Humanos , Artroplastia de Reemplazo de Cadera/métodos , Femenino , Masculino , Persona de Mediana Edad , Anciano , Resultado del Tratamiento , Osteoartritis de la Cadera/cirugía , Reoperación/estadística & datos numéricos , Estudios de Seguimiento , Complicaciones Posoperatorias/etiología , Articulación de la Cadera/cirugía , Articulación de la Cadera/diagnóstico por imagen , Recuperación de la Función
8.
Bone Joint J ; 106-B(5 Supple B): 98-104, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38688511

RESUMEN

Aims: Dual-mobility (DM) components are increasingly used to prevent and treat dislocation after total hip arthroplasty (THA). Intraprosthetic dissociation (IPD) is a rare complication of DM that is believed to have decreased with contemporary implants. This study aimed to report incidence, treatment, and outcomes of contemporary DM IPD. Methods: A total of 1,453 DM components were implanted at a single academic institution between January 2010 and December 2021: 695 in primary and 758 in revision THA. Of these, 49 presented with a dislocation of the large DM head and five presented with an IPD. At the time of closed reduction of the large DM dislocation, six additional IPDs occurred. The mean age was 64 years (SD 9.6), 54.5% were female (n = 6), and mean follow-up was 4.2 years (SD 1.8). Of the 11 IPDs, seven had a history of instability, five had abductor insufficiency, four had prior lumbar fusion, and two were conversions for failed fracture management. Results: The incidence of IPD was 0.76%. Of the 11 IPDs, ten were missed either at presentation or after attempted reduction. All ten patients with a missed IPD were discharged with a presumed reduction. The mean time from IPD to surgical treatment was three weeks (0 to 23). One patient died after IPD prior to revision. Of the ten remaining hips with IPD, the DM head was exchanged in two, four underwent acetabular revision with DM exchange, and four were revised to a constrained liner. Of these, five (50%) underwent reoperation at a mean 1.8 years (SD 0.73), including one additional acetabular revision. No patients who underwent initial acetabular revision for IPD treatment required subsequent reoperation. Conclusion: The overall rate of IPD was low at 0.76%. It is essential to identify an IPD on radiographs as the majority were missed at presentation or after iatrogenic dissociation. Surgeons should consider acetabular revision for IPD to allow conversion to a larger DM head, and take care to remove impinging structures that may increase the risk of subsequent failure.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Falla de Prótesis , Reoperación , Humanos , Femenino , Persona de Mediana Edad , Artroplastia de Reemplazo de Cadera/métodos , Masculino , Incidencia , Reoperación/estadística & datos numéricos , Anciano , Diseño de Prótesis , Estudios Retrospectivos , Complicaciones Posoperatorias/epidemiología , Luxación de la Cadera/cirugía , Luxación de la Cadera/etiología , Resultado del Tratamiento
10.
J Arthroplasty ; 2024 Mar 26.
Artículo en Inglés | MEDLINE | ID: mdl-38548235

RESUMEN

BACKGROUND: Previous studies have suggested that wound complications may differ by surgical approach after total hip arthroplasty (THA), with particular attention toward the direct anterior approach (DAA). However, there is a paucity of data documenting wound complication rates by surgical approach and the impact of concomitant patient factors, namely body mass index (BMI). This investigation sought to determine the rates of wound complications by surgical approach and identify BMI thresholds that portend differential risk. METHODS: This multicenter study retrospectively evaluated all primary THA patients from 2010 to 2023. Patients were classified by skin incision as having a laterally based approach (posterior or lateral approach) or DAA (longitudinal incision). We identified 17,111 patients who had 11,585 laterally based (68%) and 5,526 (32%) DAA THAs. The mean age was 65 years (range, 18 to 100), 8,945 patients (52%) were women, and the mean BMI was 30 (range, 14 to 79). Logistic regression and cut-point analyses were performed to identify an optimal BMI cutoff, overall and by approach, with respect to the risk of wound complications at 90 days. RESULTS: The 90-day risk of wound complications was higher in the DAA group versus the laterally based group, with an absolute risk of 3.6% versus 2.6% and a multivariable adjusted odds ratio of 1.5 (P < .001). Cut-point analyses demonstrated that the risk of wound complications increased steadily for both approaches, but most markedly above a BMI of 33. CONCLUSIONS: Wound complications were higher after longitudinal incision DAA THA compared to laterally based approaches, with a 1% higher absolute risk and an adjusted odds ratio of 1.5. Furthermore, BMI was an independent risk factor for wound complications regardless of surgical approach, with an optimal cut-point BMI of 33 for both approaches. These data can be used by surgeons to help consider the risks and benefits of approach selection. LEVEL OF EVIDENCE: Level III.

11.
J Arthroplasty ; 39(9S1): S3-S8, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38479635

RESUMEN

BACKGROUND: Intraprosthetic dissociation (IPD) is a complication unique to dual mobility (DM) implants where the outer polyethylene head dissociates from the inner femoral head. Increasing reports of IPD at the time of closed reduction of large head DM dislocations prompted this biomechanical study evaluating the assembly and dissociation forces of DM heads. METHODS: We tested 17 polyethylene DM heads from 5 vendors. Of the heads, 12 were highly cross-linked polyethylene (4 vendors) and 5 were infused with vitamin E (2 vendors). Heads were between 46 and 47 mm in diameter, accepting a 28 mm-inner ceramic head. Implants were assembled and disassembled using a servohydraulic machine that recorded the forces and torques applied during testing. Dissociation was tested via both axial pull-out and lever-out techniques, where lever-out simulated stem-on-acetabular component impingement. RESULTS: The initial maximum assembly force was significantly different between all vendors (P < .01) and decreased for all implants with subsequent assembly. Vendor 4-E (Link with vitamin E) heads required the highest assembly force (1,831.9 ± 81.95 N), followed by Vendor 3 (Smith & Nephew), Vendor 5 (DePuy Synthes), Vendor 1-E (Zimmer Biomet with vitamin E), Vendor 2 (Stryker), and Vendor 1 (Zimmer Biomet Arcom). Vendor 4-E implants showed the greatest dissociation resistance in both pull-out (2,059.89 N, n = 1) and lever-out (38.95 ± 2.79 Nm) tests. Vendor 1-E implants with vitamin E required higher assembly force, dissociation force, and energy than Vendor 1 heads without vitamin E. CONCLUSIONS: There were notable differences in DM assembly and dissociation forces between implants. Diminishing force was required for assembly with each additional trial across vendors. Vendor 4-E DM heads required the highest assembly and dissociation forces. Vitamin E appeared to increase the assembly and dissociation forces. Based on these results, DM polyethylene heads should not be reimplanted after dissociation, and there may be a role for establishing a minimum dissociation energy standard to minimize IPD risk.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Ensayo de Materiales , Diseño de Prótesis , Falla de Prótesis , Fenómenos Biomecánicos , Humanos , Artroplastia de Reemplazo de Cadera/instrumentación , Polietileno/química , Distinciones y Premios , Cabeza Femoral , Vitamina E
12.
Int Orthop ; 48(4): 997-1010, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38224400

RESUMEN

PURPOSE: The purpose of this review is to evaluate the current status of research on the application of artificial intelligence (AI)-based three-dimensional (3D) templating in preoperative planning of total joint arthroplasty. METHODS: This scoping review followed the PRISMA, PRISMA-ScR guidelines, and five stage methodological framework for scoping reviews. Studies of patients undergoing primary or revision joint arthroplasty surgery that utilised AI-based 3D templating for surgical planning were included. Outcome measures included dataset and model development characteristics, AI performance metrics, and time performance. After AI-based 3D planning, the accuracy of component size and placement estimation and postoperative outcome data were collected. RESULTS: Nine studies satisfied inclusion criteria including a focus on computed tomography (CT) or magnetic resonance imaging (MRI)-based AI templating for use in hip or knee arthroplasty. AI-based 3D templating systems reduced surgical planning time and improved implant size/position and imaging feature estimation compared to conventional radiographic templating. Several components of data processing and model development and testing were insufficiently covered in the studies included in this scoping review. CONCLUSIONS: AI-based 3D templating systems have the potential to improve preoperative planning for joint arthroplasty surgery. This technology offers more accurate and personalized preoperative planning, which has potential to improve functional outcomes for patients. However, deficiencies in several key areas, including data handling, model development, and testing, can potentially hinder the reproducibility and reliability of the methods proposed. As such, further research is needed to definitively evaluate the efficacy and feasibility of these systems.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Rodilla , Inteligencia Artificial , Imagenología Tridimensional , Humanos , Imagenología Tridimensional/métodos , Artroplastia de Reemplazo de Cadera/métodos , Artroplastia de Reemplazo de Rodilla/métodos , Tomografía Computarizada por Rayos X/métodos , Imagen por Resonancia Magnética/métodos , Cirugía Asistida por Computador/métodos , Cuidados Preoperatorios/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA