1.
Pacing Clin Electrophysiol ; 47(5): 595-602, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38523591

RESUMEN

BACKGROUND: Data are lacking on patient-reported outcomes (PRO) following cryoballoon ablation (CBA) versus radiofrequency ablation (RFA). We sought to evaluate QoL and clinical outcomes of cryoballoon pulmonary vein isolation only (CRYO-PVI-ONLY) versus RFA with PVI and posterior wall isolation (RF-PVI+PWI) in a large prospective PRO registry. METHODS: Patients who underwent AF ablation (2013-2016) at our institution were enrolled in an automated, prospectively maintained PRO registry. CRYO-PVI-ONLY patients were matched (1:1) with RF-PVI+PWI patients based on age, gender, and type of AF (paroxysmal vs. persistent). QoL and clinical outcomes were assessed using PRO surveys at baseline and at 1-year. The atrial fibrillation symptom severity scale (AFSSS) was the measure for QoL. Additionally, we assessed patient-reported clinical improvement, arrhythmia recurrence, and AF burden (as indicated by AF frequency and duration scores). RESULTS: A total of 296 patients were included (148 in each group, 72% paroxysmal). By PRO, a significant improvement in QoL was observed in the overall study population and was comparable between CRYO-PVI-ONLY and RF-PVI+PWI (baseline median AFSSS of 11.5 and 11; reduced to 2 and 4 at 1 year, respectively; p = 0.44). Similarly, the proportion of patients who reported improvement in their overall QoL and AF related symptoms was high and similar between the study groups [92% (CRYO-PVI-ONLY) vs. 92.8% (RF-PVI+PWI); p = 0.88]. Arrhythmia recurrence was significantly more common in the CRYO-PVI-ONLY group (39.7%) compared to RF-PVI+PWI (27.7 %); p = 0.03. Comparable results were observed in paroxysmal and persistent AF. CONCLUSION: CRYO-PVI-ONLY and RF-PVI+PWI resulted in comparable improvements in patient reported outcomes including QoL and AF burden; with RF-PVI+PWI being more effective at reducing recurrences.


Asunto(s)
Fibrilación Atrial , Criocirugía , Medición de Resultados Informados por el Paciente , Venas Pulmonares , Humanos , Venas Pulmonares/cirugía , Masculino , Femenino , Criocirugía/métodos , Fibrilación Atrial/cirugía , Persona de Mediana Edad , Estudios Prospectivos , Atrios Cardíacos/cirugía , Ablación por Catéter/métodos , Sistema de Registros , Calidad de Vida , Anciano , Ablación por Radiofrecuencia/métodos
2.
J Cardiovasc Electrophysiol ; 35(3): 583-591, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37811553

RESUMEN

BACKGROUND: Height, left ventricular (LV) size, and sex were proposed as additional criteria for patient selection for cardiac resynchronization therapy (CRT) but their connections with the QRS complex in left bundle branch block (LBBB) are little investigated. We evaluated these. METHODS: Among patients with "true" LBBB, QRS duration (QRSd) and amplitude, and LV hypertrophy indices, were correlated with patient's height and LV mass, and compared between sexes. RESULTS: In this study cohort (n = 220; 60 ± 12 years; left ventricular ejection fraction [LVEF] 21 ± 7%; mostly New York Heart Association II-III, QRSd 165 ± 19 ms; 57% female; 70% responders [LVEF increased ≥5%]), LV mass was increased in all patients. QRS amplitude did not correlate with LV mass or height in any individual lead or with Sokolow-Lyon or Cornell-Lyon indices. QRSd did not correlate with height. In contrast, QRSd correlated strongly with LV mass (r = .51). CRT response rate was greater in women versus men (84% vs. 58%, p < .001) despite shorter QRSd [7% shorter (p < .0001)]. QRSd normalized for height resulted in a 2.7% and for LV mass 24% greater index in women. CONCLUSION: True LBBB criteria do not exclude HF patients with increased LV mass. QRS amplitudes do not correlate with height or LV mass. Height does not affect QRSd. However, QRSd correlates with LV size. QRSd normalized for LV mass results in 24% greater value in women in the direction of sex-specific responses. LV mass may be a significant nonelectrical modifier of QRSd for CRT.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Masculino , Humanos , Femenino , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/terapia , Volumen Sistólico/fisiología , Función Ventricular Izquierda/fisiología , Resultado del Tratamiento , Electrocardiografía , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Terapia de Resincronización Cardíaca/métodos
3.
Circ Arrhythm Electrophysiol ; 16(6): e011565, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37183675

RESUMEN

BACKGROUND: Ablation is used for both rhythm control and improved quality of life (QoL) in atrial fibrillation (AF). It has been suggested that young adults may experience high recurrence rates after ablation and data remain lacking regarding QoL benefits. We aimed to investigate AF ablation outcomes and QoL benefits in young adults undergoing AF ablation using a large prospectively maintained registry and automated patient-reported outcomes (PRO). METHODS: All patients undergoing AF ablation (2013-2016) at our center were prospectively enrolled. Patients aged 50 years or younger were included. For PROs, QoL measures and symptoms were assessed at baseline, 3 months after ablation, and every 6 months thereafter. The AF severity score served as the main assessment of QoL. RESULTS: A total of 241 young adults (age, 16-50 years) were included (17% female, 40.3% persistent AF). In all, 77.2% of patients remained arrhythmia-free during the first year of follow-up (80% in nonstructural AF and 66% in structural AF). Using PROs, 90% of patients reported improvement in QoL throughout all survey time points up to 5 years postablation (P<0.0001). The baseline median AF severity score was 14 and improved to between 2 and 4 on all follow-up after ablation (P<0.0001). Patients also reported fewer and shorter AF episodes, fewer emergency room visits secondary to AF, and fewer hospitalizations (P<0.0001). CONCLUSIONS: Ablation remains an effective rhythm-control strategy in young adults with AF. Young adults also experience significant improvement in QoL with reduction of the frequency and duration of AF episodes and AF-related healthcare utilization.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Femenino , Adulto Joven , Adolescente , Adulto , Persona de Mediana Edad , Masculino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Calidad de Vida , Resultado del Tratamiento , Ablación por Catéter/efectos adversos , Recurrencia
4.
Circ Arrhythm Electrophysiol ; 16(5): e011771, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37082968

RESUMEN

BACKGROUND: Confirming the presence and participation of concealed nodo-ventricular (cNV) or concealed His-ventricular (cHV) pathways in tachyarrhythmias is challenging. We describe novel observations to aid in diagnosing cNV or cHV pathways. METHODS: We present 7 cases of cNV and cHV pathway-mediated arrhythmias and focus on several laboratory observations: (1) differential ventricular overdrive pacing (VOD) from the base versus apex, (2) response to His refractory premature ventricular complexes, (3) paradoxical atriohisian response (shorter atriohisian interval during tachycardia than that during sinus rhythm) in long RP tachycardia, and (4) the role of adenosine to aid in the diagnosis. RESULTS: Three cases underwent differential VOD during tachycardia. All demonstrated a shorter postpacing interval minus tachycardia cycle length during basal pacing than apical pacing with one case exhibiting apical VOD results compatible with atrioventricular nodal reentrant tachycardia. Basal VOD was useful for localizing the ventricular connection in a case with cHV pathway. In 3 cases, His refractory premature ventricular complexes reset the tachycardia without conduction to the atrium, which excluded the involvement of an atrioventricular pathway or atrial tachycardia, or atrioventricular nodal reentrant tachycardia alone. One case had His refractory premature ventricular complexes followed by subsequent constant AA interval and then tachycardia termination, suggesting a bystander cNV pathway involvement. Two cNV pathway cases presented with long RP tachycardia had paradoxical atriohisian shortening of >15 ms, suggesting parallel activation of the atrium and the atrioventricular node. Adenosine terminated the tachycardia with retrograde block in 2 cases with cNV pathways but had no response on a cHV pathway. CONCLUSIONS: cNV and cHV pathways mediated tachyarrhythmias can present with variable clinical presentations. We emphasize the important role of differential VOD sites, His refractory premature ventricular complexes that reset or terminate the tachycardia without conduction to the atrium, paradoxical atriohisian response in long RP tachycardia, and the use of adenosine for diagnosing cNV and cHV pathways.


Asunto(s)
Taquicardia por Reentrada en el Nodo Atrioventricular , Taquicardia Supraventricular , Complejos Prematuros Ventriculares , Humanos , Nodo Atrioventricular , Taquicardia , Adenosina , Electrocardiografía , Complejos Prematuros Ventriculares/diagnóstico , Estimulación Cardíaca Artificial/métodos
5.
J Interv Card Electrophysiol ; 66(9): 2041-2046, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37014480

RESUMEN

BACKGROUND: Left bundle branch area pacing (LBBAP) is a newer technique to deliver more synchronous left ventricular activation. Several criteria have been proposed, but not fully validated, to confirm LBBAP during implantation of the pacing lead. Spectral analysis has been used to characterize the frequency components of the clinical QRS utilizing the Fourier transform algorithm. We hypothesized that higher frequency content of the paced QRS complex may show predictive value of successful LBBAP. METHODS: We evaluated 84 patients with ejection fraction > 50%, who underwent LBB lead placement (n = 42) using ≥ 1 current criteria and right ventricular midseptal (RVsp) lead placement (n = 42) from 2000 to 2022. Time frequency analysis (Matlab) was used to determine the frequency content of the paced QRS complex. The centroid frequency (CF), which is the weighted average QRS frequency, was calculated. RESULTS: Patients in RVsp group had a longer paced QRS duration (155.6 ± 28.0 vs 127.1 ± 17.2, p < 0.002) compared to the LBBAP group. Of all standard ECG leads, the paced QRS in V2 gave the greatest difference of the CF of the LBBAP group at 8.8 ± 1.6 Hz versus 5.7 ± 0.7 Hz of the RVsp group. This difference was significant by both univariate (p < 0.003) and multivariate (p < 0.010) analysis. Predictive value of the CF for successful LBB pacing in lead V2 was highest with an AUC of 0.98. The sensitivity and specificity were 88.1% and 97.6%, respectively. CONCLUSION: Spectral analysis predicts successful LBBAP with higher frequency content when compared to RVsp pacing. Given the limitations to the current criteria to confirm LBBAP, intraprocedural use of frequency content analysis of the paced QRS complex in patients may prove useful at verifying LBB capture if verified by prospective clinical trials.


Asunto(s)
Terapia de Resincronización Cardíaca , Tabique Interventricular , Humanos , Estimulación Cardíaca Artificial/métodos , Estudios Prospectivos , Resultado del Tratamiento , Sistema de Conducción Cardíaco , Terapia de Resincronización Cardíaca/métodos , Electrocardiografía/métodos , Fascículo Atrioventricular
7.
JACC Clin Electrophysiol ; 9(3): 425-441, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36990601

RESUMEN

Junctional tachycardia (JT) is typically considered to have an automatic mechanism originating from the distal atrioventricular node. When there is 1:1 retrograde conduction via the fast pathway, JT would resemble the typical form of atrioventricular nodal re-entrant tachycardia (AVNRT). Atrial pacing maneuvers have been proposed to exclude AVNRT and suggest a diagnosis of JT. However, after excluding AVNRT, one should consider the possibility of an infra-atrial narrow QRS re-entrant tachycardia, which can exhibit features that resemble AVNRT as well as JT. Pacing maneuvers and mapping techniques should be performed to assess for infra-atrial re-entrant tachycardia before concluding that JT is the mechanism of a narrow QRS tachycardia. Distinguishing JT from typical AVNRT or infra-atrial re-entrant tachycardia has notable implications regarding the approach to ablation of the tachycardia. Ultimately, a contemporary review of the evidence on JT raises some questions as to the mechanism and source of what has traditionally been considered JT.


Asunto(s)
Fibrilación Atrial , Taquicardia por Reentrada en el Nodo Atrioventricular , Taquicardia Ectópica de Unión , Taquicardia Supraventricular , Humanos , Técnicas Electrofisiológicas Cardíacas/métodos , Taquicardia Ectópica de Unión/diagnóstico , Nodo Atrioventricular , Fascículo Atrioventricular , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía
8.
J Cardiovasc Electrophysiol ; 34(1): 54-61, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36259719

RESUMEN

INTRODUCTION: Catheter ablation for atrial fibrillation (AF) is frequently used for the purpose of rhythm control and improved quality of life (QoL). Although success rates are high, a significant proportion of patients require redo ablation. Data are scarce on patient-centered outcomes and QoL in patients undergoing redo AF ablation. We aimed to assess QoL and clinical outcomes using a large prospectively maintained patient-reported outcomes (PRO) registry. METHODS: All patients undergoing redo AF ablation (2013-2016) at our center were enrolled in a prospective registry for outcomes and assessed for QoL using automated PRO surveys (baseline, 3 and 6 months after ablation, every 6 months thereafter). Data were collected over 3 years of follow-up. The atrial fibrillation symptom severity scale (AFSSS) was used as the main measure for QoL. Additional variables included patient-reported improvement, AF burden, and AF-related healthcare utilization including emergency room (ER) visits and hospitalizations. RESULTS: A total of 848 patients were included (28% females, mean age 63.8, 51% persistent AF). By automated PRO, significant improvement in QoL was noted (baseline median AFSSS of 12 [5-18] and ranged between 2 and 4 on subsequent assessments; p < .0001), with ≥70%of patients reported remarkable improvement in their AF-related symptoms. The proportion of patients in AF at the time of baseline survey was 36%, and this decreased to <8% across all time points during follow-up (p < .0001). AF burden was significantly reduced (including frequency and duration of episodes; p < .0001), with an associated decrease in healthcare utilization after 6 months from the time of ablation (including ER visits and hospitalizations; p < .0001). The proportion of patients on anticoagulants or antiarrhythmics decreased on follow-up across all time points (p < .0001 for all variables). CONCLUSION: Most patients derive significant QoL benefit from redo AF ablation; with reduction of both AF burden and healthcare utilization.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Femenino , Humanos , Persona de Mediana Edad , Masculino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Calidad de Vida , Resultado del Tratamiento , Antiarrítmicos/uso terapéutico , Ablación por Catéter/efectos adversos , Medición de Resultados Informados por el Paciente
10.
JACC Clin Electrophysiol ; 8(4): 498-510, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35450605

RESUMEN

OBJECTIVES: This study sought to examine the effect of the return electrode's surface area on bipolar RFA lesion size. BACKGROUND: Bipolar radiofrequency ablation (RFA) is typically performed between 2 3.5-mm tip catheters serving as active and return electrodes. We hypothesized that increasing the surface area of the return electrode would increase lesion dimensions by reducing the circuit impedance, thus increasing the current into a larger tissue volume enclosed between the electrodes. METHODS: In step 1, ex vivo bipolar RFA was performed between 3.5-mm and custom-made return electrodes with increasing surface areas (20, 80, 180 mm2). In step 2, ex vivo bipolar RFA was performed between 3.5-mm and 3.5-mm or 8-mm electrode catheters positioned perpendicular or parallel to the tissue. In step 3, in vivo bipolar RFA was performed between 3.5-mm and either 3.5-mm or 8-mm parallel electrode at the: 1) left ventricular summit; 2) interventricular septum; and 3) healed anterior infarction. RESULTS: In step 1, increasing the surface area of the return electrode resulted in lower circuit impedance (R = -0.65; P < 0.001), higher current (R = +0.80; P < 0.001), and larger lesion volume (R = +0.88; P < 0.001). In step 2, an 8-mm return electrode parallel to tissue produced larger and deeper lesions compared with a 3.5-mm return electrode (P = 0.014 and P = 0.02). Similarly, in step 3, compared with a 3.5-mm, bipolar RFA with an 8-mm return electrode produced larger (volume: 1,525 ± 871 mm3 vs 306 ± 310 mm3, respectively; P < 0.001) and more transmural lesions (88% vs 0%; P < 0.001). CONCLUSIONS: Bipolar RFA using an 8-mm return electrode positioned parallel to the tissue produces larger lesions in comparison with a 3.5-mm return electrode.


Asunto(s)
Ablación por Catéter , Ablación por Catéter/métodos , Electrodos , Diseño de Equipo , Ventrículos Cardíacos/cirugía , Humanos
12.
J Cardiovasc Electrophysiol ; 33(6): 1177-1182, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35348267

RESUMEN

INTRODUCTION: The surface electrocardiography of typical atrioventricular nodal reentrant tachycardia (AVNRT) shows simultaneous ventricular-atrial (RP) activation with pseudo R' in V1 and typical heart rates ranging from 150 to 220/min. Slower rates are suspicious for junctional tachycardia (JT). However, occasionally we encounter typical AVNRT with slow ventricular rates. We describe a series of typical AVNRT cases with heart rates under 110/min. METHODS: A total of 1972 patients with AVNRT who underwent slow pathway ablation were analyzed. Typical AVNRT was diagnosed when; (1) evidence of dual atrioventricular nodal conduction, (2) tachycardia initiation by atrial drive train with atrial-His-atrial response, (3) short septal ventriculoatrial time, and (4) ventricular-atrial-ventricular (V-A-V) response to ventricular overdrive (VOD) pacing with corrected post pacing interval-tachycardia cycle length (cPPI-TCL) > 110 ms. JT was excluded by either termination or advancement of tachycardia by atrial extrastimuli (AES) or atrial overdrive (AOD) pacing. RESULTS: We found 11 patients (age 20-78 years old, six female) who met the above-mentioned criteria. The TCL ranged from 560 to 782 ms. Except for one patient showing tachycardia termination, all patients demonstrated a V-A-V response and cPPI-TCL over 110 ms with VOD. AES or AOD pacing successfully excluded JT by either advancing the tachycardia in 10 patients or by tachycardia termination in one patient. Slow pathway was successfully ablated, and tachycardia was not inducible in all patients. CONCLUSIONS: This case series describes patients with typical AVNRT with slow ventricular rate (less than 110/min) who may mimic JT. We emphasize the importance of using pacing maneuvers to exclude JT.


Asunto(s)
Taquicardia por Reentrada en el Nodo Atrioventricular , Adulto , Anciano , Fascículo Atrioventricular , Estimulación Cardíaca Artificial , Diagnóstico Diferencial , Electrocardiografía , Femenino , Humanos , Persona de Mediana Edad , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Adulto Joven
13.
J Cardiovasc Electrophysiol ; 33(2): 234-240, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34911148

RESUMEN

OBJECTIVE: To test whether a high defibrillation threshold (DFT) marks patients with poor outcomes which are improved when DFT is decreased by system modification (subcutaneous coil implant; SM). BACKGROUND: The electrical substrate generating fast ventricular arrhythmias may generate poor outcomes among patients treated with implantable cardioverter-defibrillators (ICDs), even when arrhythmias are treated successfully. Since patients with high DFTs have increased mortality, we contrasted survival among patients with high DFT treated with and without SM. METHODS: We studied consecutive patients undergoing ICD implantation and DFT testing at Cleveland Clinic over a 14-year period. High DFT was defined as successful defibrillation by shock strength >25 J or ≤10 J of maximal device output. Mortality was recorded using the Social Security Death Index. Survival was compared among those high DFT patients receiving SM versus the remainder. RESULTS: Out of 6353 patients tested, 191 (3%) had high DFT (32.1 ± 3.7 J) versus 13.9 ± 4.9 J in the remainder ("acceptable DFT," p < .001). One hundred twenty-one high DFT patients (63%; 33.3 ± 3.4 J) underwent SM, which significantly decreased DFT (24.8 ± 5.9 J; p < .001). Seventy patients (37%; 30.3 ± 3.3 J) did not undergo SM. During follow-up, 38% (2363/6162; 7.8 yrs) patients with acceptable DFT died versus 48% high DFT patients (91/191; 5.6 yrs.; p < .001). Concomitantly, 48% patients with SM (58/121) died, as compared to 47% patients (33/70) without SM (p = .91); median follow-up 4.9 yrs). CONCLUSION: Patients with high DFT have a higher mortality than those with acceptable DFT. The additional subcutaneous coil implant decreases DFT to an acceptable range but does not appear to improve survival. The electrical substrate underlying high DFT appears to determine survival.


Asunto(s)
Desfibriladores Implantables , Cardioversión Eléctrica , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiología , Arritmias Cardíacas/terapia , Desfibriladores Implantables/efectos adversos , Cardioversión Eléctrica/efectos adversos , Humanos , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/etiología , Fibrilación Ventricular/terapia
15.
J Innov Card Rhythm Manag ; 12(9): 4657-4669, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34595049

RESUMEN

The Rhythmia™ system (Boston Scientific, Natick, MA, USA) facilitates the rapid acquisition of high-resolution electroanatomical and activation maps. However, there are limited data on its efficacy and safety in pediatric and adult congenital heart disease (CHD) patients. In a retrospective, observational cohort study, adult CHD and pediatric patients followed by pediatric cardiology underwent electrophysiologic study using the Rhythmia™ electroanatomic mapping system. Variables examined included the number of electroanatomical maps required, acquisition time, procedure time, fluoroscopy time, radiation dosage, and rate of recurrent arrhythmia. Twelve consecutive patients, including six male patients (50%), were included with an average age of 27.7 years (range: 11-64 years). Seven (58%) of these patients had a diagnosis of CHD [moderate complexity in two (17%) and great complexity in five patients (42%)] and 10 (83%) patients underwent ablation. A total of 37 high-density maps were created in 12 procedures, with a median of 8,140 mapping points, taking a median of 631 seconds. The median procedure time was 189.5 minutes. The median fluoroscopy time was 0.9 minutes, with eight (67%) patients receiving no fluoroscopy at all. Recurrence occurred in one patient (8%) over a median follow-up duration of 16 months (interquartile range: 12.8-17.3 months). No adverse periprocedural events were recorded. This study suggests the use of high-density electroanatomic mapping in adult CHD patients showed potential for rapid acquisition of highly detailed maps with minimal fluoroscopy time or risk of periprocedural events in the studied population.

16.
JACC Clin Electrophysiol ; 7(12): 1588-1599, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34332874

RESUMEN

OBJECTIVES: This study sought to describe the electrophysiologic characteristics, diagnostic maneuvers, and treatment of a series of arrhythmias using concealed nodoventricular (cNV) or His-ventricular (cHV) pathways. BACKGROUND: Confirming the presence and participation of cNV or cHV pathways in tachyarrhythmias is challenging. METHODS: We present 4 cases of tachycardias with a participatory cNV or cHV pathway. RESULTS: The first patient had a narrow complex tachycardia with ventriculoatrial dissociation. Findings of an entrainment pacing from the right ventricle and fused premature ventricular complexes suggested cNV pathway involvement. The second patient had nonsustained narrow complex tachycardia with more ventricular than atrial complexes. The tachycardia exhibited an anterograde His-right bundle (RB) activation sequence and normal His-ventricular (HV) interval and consistently terminated with fused ventricular extra stimuli, suggesting cNV pathway participation. The third patient had a wide complex tachycardia (WCT) with either a right or left bundle branch block pattern. The WCT showed an eccentric His-RB activation sequence and short HV interval and terminated with fused premature ventricular complexes, suggesting a cHV (or concealed fasciculoventricular) pathway involvement. The fourth patient had a WCT with alternating bundle branch block morphologies with a short HV interval. Entrainment from the basal right ventricle demonstrated fusion and a short postpacing interval, suggesting cHV (or fasciculoventricular) pathway involvement. Ablation at the proximal RB rendered the tachycardia noninducible. CONCLUSIONS: A structured approach can help diagnose and treat cNV or cHV pathways. We emphasize the importance of evaluating both the His-RB activation pattern and HV interval during sinus rhythm and tachycardia as well as the ventricular pacing study.


Asunto(s)
Fascículo Atrioventricular Accesorio , Ventrículos Cardíacos , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/terapia , Electrocardiografía , Sistema de Conducción Cardíaco , Ventrículos Cardíacos/diagnóstico por imagen , Humanos
19.
J Cardiovasc Electrophysiol ; 32(7): 1909-1917, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33955116

RESUMEN

BACKGROUND: Activation maps of scar-related atrial tachycardias (AT) can be challenging to interpret due to difficulty in inaccurate annotation of electrograms, and an arbitrarily predefined mapping window. A novel mapping software integrating vector data and applying an algorithmic solution taking into consideration global activation pattern has been recently described (Coherent™, Biosense Webster "Investigational"). OBJECTIVE: We aimed to assess the investigational algorithm to determine the mechanism of AT compared with the standard algorithm. METHODS: This study included patients who underwent ablation of scar-related AT using the Carto 3 and the standard activation algorithm. The mapping data were analyzed retrospectively using the investigational algorithm, and the mechanisms were evaluated by two independent electrophysiologists. RESULTS: A total of 77 scar-related AT activation maps were analyzed (89.6% left atrium, median tachycardia cycle length of 273 ms). Of those, 67 cases with a confirmed mechanism of arrhythmia were used to compare the activation software. The actual mechanism of the arrhythmia was more likely to be identified with the investigational algorithm (67.2% vs. 44.8%, p = .009). In five patients with dual-loop circuits, 3/5 (60%) were correctly identified by the investigational algorithm compared to 0/5 (0%) with the standard software. The reduced atrial voltage was prone to lead to less capable identification of mechanism (p for trend: .05). The investigational algorithm showed higher inter-reviewer agreement (Cohen's kappa .62 vs. .47). CONCLUSIONS: In patients with scar-related ATs, activation mapping algorithms integrating vector data and "best-fit" propagation solution may help in identifying the mechanism and the successful site of termination.


Asunto(s)
Ablación por Catéter , Cicatriz , Algoritmos , Cicatriz/diagnóstico , Técnicas Electrofisiológicas Cardíacas , Humanos , Estudios Prospectivos , Estudios Retrospectivos , Taquicardia
20.
BMC Med Imaging ; 21(1): 45, 2021 03 09.
Artículo en Inglés | MEDLINE | ID: mdl-33750343

RESUMEN

OBJECTIVE: To investigate left atrial shape differences on CT scans of atrial fibrillation (AF) patients with (AF+) versus without (AF-) post-ablation recurrence and whether these shape differences predict AF recurrence. METHODS: This retrospective study included 68 AF patients who had pre-catheter ablation cardiac CT scans with contrast. AF recurrence was defined at 1 year, excluding a 3-month post-ablation blanking period. After creating atlases of atrial models from segmented AF+ and AF- CT images, an atlas-based implicit shape differentiation method was used to identify surface of interest (SOI). After registering the SOI to each patient model, statistics of the deformation on the SOI were used to create shape descriptors. The performance in predicting AF recurrence using shape features at and outside the SOI and eight clinical factors (age, sex, left atrial volume, left ventricular ejection fraction, body mass index, sinus rhythm, and AF type [persistent vs paroxysmal], catheter-ablation type [Cryoablation vs Irrigated RF]) were compared using 100 runs of fivefold cross validation. RESULTS: Differences in atrial shape were found surrounding the pulmonary vein ostia and the base of the left atrial appendage. In the prediction of AF recurrence, the area under the receiver-operating characteristics curve (AUC) was 0.67 for shape features from the SOI, 0.58 for shape features outside the SOI, 0.71 for the clinical parameters, and 0.78 combining shape and clinical features. CONCLUSION: Differences in left atrial shape were identified between AF recurrent and non-recurrent patients using pre-procedure CT scans. New radiomic features corresponding to the differences in shape were found to predict post-ablation AF recurrence.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Atrios Cardíacos/anatomía & histología , Aprendizaje Automático , Venas Pulmonares/anatomía & histología , Anciano , Apéndice Atrial/anatomía & histología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Curva ROC , Recurrencia , Estudios Retrospectivos