Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Cancer ; 130(3): 439-452, 2024 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-37795845

RESUMEN

BACKGROUND: Tobacco use is associated with adverse outcomes among patients diagnosed with cancer. Socioeconomic determinants influence access and utilization of tobacco treatment; little is known about the relationship between neighborhood socioeconomic disadvantage (NSD) and tobacco assessment, assistance, and cessation among patients diagnosed with cancer. METHODS: A modified Cancer Patient Tobacco Use Questionnaire (C-TUQ) was administered to patients enrolled in nine ECOG-ACRIN clinical trials. We examined associations of NSD with (1) smoking status, (2) receiving tobacco cessation assessment and support, and (3) cessation behaviors. NSD was classified by tertiles of the Area Deprivation Index. Associations between NSD and tobacco variables were evaluated using logistic regression. RESULTS: A total of 740 patients completing the C-TUQ were 70% male, 94% White, 3% Hispanic, mean age 58.8 years. Cancer diagnoses included leukemia 263 (36%), lymphoma 141 (19%), prostate 131 (18%), breast 79 (11%), melanoma 69 (9%), myeloma 53 (7%), and head and neck 4 (0.5%). A total of 402 (54%) never smoked, 257 (35%) had formerly smoked, and 81 (11%) were currently smoking. Patients in high disadvantaged neighborhoods were approximately four times more likely to report current smoking (odds ratio [OR], 3.57; 95% CI, 1.69-7.54; p = .0009), and more likely to report being asked about smoking (OR, 4.24; 95% CI, 1.64-10.98; p = .0029), but less likely to report receiving counseling (OR, 0.11; 95% CI, 0.02-0.58; p = .0086) versus those in the least disadvantaged neighborhoods. CONCLUSIONS: Greater neighborhood socioeconomic disadvantage was associated with smoking but less cessation support. Increased cessation support in cancer care is needed, particularly for patients from disadvantaged neighborhoods.


Asunto(s)
Neoplasias , Cese del Hábito de Fumar , Adulto , Humanos , Masculino , Persona de Mediana Edad , Femenino , Cese del Hábito de Fumar/métodos , Disparidades Socioeconómicas en Salud , Fumar/efectos adversos , Conductas Relacionadas con la Salud , Neoplasias/epidemiología , Neoplasias/terapia
2.
BMC Gastroenterol ; 23(1): 75, 2023 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-36922785

RESUMEN

BACKGROUND: Primary sclerosing cholangitis (PSC) is a chronic progressive liver disease leading to biliary fibrosis and cirrhosis. Cilofexor is a nonsteroidal farnesoid X receptor agonist that demonstrated significant improvements in liver biochemistry and markers of cholestasis in patients with PSC in a phase 2 study. We describe here the rationale, design, and implementation of the phase 3 PRIMIS trial, the largest placebo-controlled trial in PSC. METHODS: Adults with large-duct PSC without cirrhosis are randomized 2:1 to receive oral cilofexor 100 mg once daily or placebo for up to 96 weeks during the blinded phase. Patients completing the blinded phase are eligible to receive open-label cilofexor 100 mg daily for up to 96 weeks. The primary objective is to evaluate whether cilofexor reduces the risk of fibrosis progression compared with placebo. Liver biopsy is performed at screening and Week 96 of the blinded phase for histologic assessment of fibrosis. The primary endpoint-chosen in conjunction with guidance from the U.S. Food and Drug Administration-is the proportion of patients with ≥ 1-stage increase in fibrosis according to Ludwig histologic classification at week 96. Secondary objectives include evaluation of changes in liver biochemistry, serum bile acids, liver fibrosis assessed by noninvasive methods, health-related quality of life, and safety of cilofexor. CONCLUSION: The phase 3 PRIMIS study is the largest randomized, double-blind, placebo-controlled trial in PSC to date and will allow for robust evaluation of the efficacy and safety of cilofexor in noncirrhotic patients with large-duct PSC. TRIAL REGISTRATION: ClinicalTrials.gov NCT03890120; registered 26/03/2019.


Asunto(s)
Colangitis Esclerosante , Adulto , Humanos , Colangitis Esclerosante/complicaciones , Colangitis Esclerosante/tratamiento farmacológico , Calidad de Vida , Cirrosis Hepática , Fibrosis
3.
Magn Reson Med ; 88(4): 1818-1827, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35713379

RESUMEN

PURPOSE: To evaluate multicenter repeatability and reproducibility of T1 and T2 maps generated using MR fingerprinting (MRF) in the International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology MRI system phantom and in prostatic tissues. METHODS: MRF experiments were performed on 5 different 3 Tesla MRI scanners at 3 different institutions: University Hospitals Cleveland Medical Center (Cleveland, OH), Brigham and Women's Hospital (Boston, MA) in the United States, and Diagnosticos da America (Rio de Janeiro, RJ) in Brazil. Raw MRF data were reconstructed using a Gadgetron-based MRF online reconstruction pipeline to yield quantitative T1 and T2 maps. The repeatability of T1 and T2 values over 6 measurements in the International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology MRI system phantom was assessed to demonstrate intrascanner variation. The reproducibility between the 4 clinical scanners was assessed to demonstrate interscanner variation. The same-day test-retest normal prostate mean T1 and T2 values from peripheral zone and transitional zone were also compared using the intraclass correlation coefficient and Bland-Altman analysis. RESULTS: The intrascanner variation of values measured using MRF was less than 2% for T1 and 4.7% for T2 for relaxation values, within the range of 307.7 to 2360 ms for T1 and 19.1 to 248.5 ms for T2 . Interscanner measurements showed that the T1 variation was less than 4.9%, and T2 variation was less than 8.1% between multicenter scanners. Both T1 and T2 values in in vivo prostatic tissue demonstrated high test-retest reliability (intraclass correlation coefficient > 0.92) and strong linear correlation (R2  > 0.840). CONCLUSION: Prostate MRF measurements of T1 and T2 are repeatable and reproducible between MRI scanners at different centers on different continents for the above measurement ranges.


Asunto(s)
Imagen por Resonancia Magnética , Próstata , Brasil , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Fantasmas de Imagen , Próstata/diagnóstico por imagen , Reproducibilidad de los Resultados
6.
Invest Radiol ; 54(4): 238-246, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30601292

RESUMEN

PURPOSE: The aim of this study was to improve the geometric fidelity and spatial resolution of multi-b diffusion-weighted magnetic resonance imaging of the prostate. MATERIALS AND METHODS: An accelerated segmented diffusion imaging sequence was developed and evaluated in 25 patients undergoing multiparametric magnetic resonance imaging examinations of the prostate. A reduced field of view was acquired using an endorectal coil. The number of sampled diffusion weightings, or b-factors, was increased to allow estimation of tissue perfusion based on the intravoxel incoherent motion (IVIM) model. Apparent diffusion coefficients measured with the proposed segmented method were compared with those obtained with conventional single-shot echo-planar imaging (EPI). RESULTS: Compared with single-shot EPI, the segmented method resulted in faster acquisition with 2-fold improvement in spatial resolution and a greater than 3-fold improvement in geometric fidelity. Apparent diffusion coefficient values measured with the novel sequence demonstrated excellent agreement with those obtained from the conventional scan (R = 0.91 for bmax = 500 s/mm and R = 0.89 for bmax = 1400 s/mm). The IVIM perfusion fraction was 4.0% ± 2.7% for normal peripheral zone, 6.6% ± 3.6% for normal transition zone, and 4.4% ± 2.9% for suspected tumor lesions. CONCLUSIONS: The proposed accelerated segmented prostate diffusion imaging sequence achieved improvements in both spatial resolution and geometric fidelity, along with concurrent quantification of IVIM perfusion.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/métodos , Interpretación de Imagen Asistida por Computador/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Anciano , Humanos , Masculino , Perfusión , Próstata/diagnóstico por imagen , Reproducibilidad de los Resultados
7.
Sci Rep ; 7(1): 3713, 2017 06 16.
Artículo en Inglés | MEDLINE | ID: mdl-28623277

RESUMEN

Fetal health is critically dependent on placental function, especially placental transport of oxygen from mother to fetus. When fetal growth is compromised, placental insufficiency must be distinguished from modest genetic growth potential. If placental insufficiency is present, the physician must trade off the risk of prolonged fetal exposure to placental insufficiency against the risks of preterm delivery. Current ultrasound methods to evaluate the placenta are indirect and insensitive. We propose to use Blood-Oxygenation-Level-Dependent (BOLD) MRI with maternal hyperoxia to quantitatively assess mismatch in placental function in seven monozygotic twin pairs naturally matched for genetic growth potential. In-utero BOLD MRI time series were acquired at 29 to 34 weeks gestational age. Maps of oxygen Time-To-Plateau (TTP) were obtained in the placentas by voxel-wise fitting of the time series. Fetal brain and liver volumes were measured based on structural MR images. After delivery, birth weights were obtained and placental pathological evaluations were performed. Mean placental TTP negatively correlated with fetal liver and brain volumes at the time of MRI as well as with birth weights. Mean placental TTP positively correlated with placental pathology. This study demonstrates the potential of BOLD MRI with maternal hyperoxia to quantify regional placental function in vivo.


Asunto(s)
Imagen por Resonancia Magnética , Oxígeno/metabolismo , Insuficiencia Placentaria/diagnóstico por imagen , Insuficiencia Placentaria/metabolismo , Encéfalo/metabolismo , Femenino , Humanos , Hiperoxia/metabolismo , Hígado/metabolismo , Imagen por Resonancia Magnética/métodos , Tamaño de los Órganos , Insuficiencia Placentaria/sangre , Insuficiencia Placentaria/patología , Embarazo , Transducción de Señal , Ultrasonografía
8.
NMR Biomed ; 29(7): 999-1009, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-27241215

RESUMEN

A biomarker of cancer aggressiveness, such as hypoxia, could substantially impact treatment decisions in the prostate, especially radiation therapy, by balancing treatment morbidity (urinary incontinence, erectile dysfunction, etc.) against mortality. R2 (*) mapping with Mono-Exponential (ME) decay modeling has shown potential for identifying areas of prostate cancer hypoxia at 1.5T. However, Gaussian deviations from ME decay have been observed in other tissues at 3T. The purpose of this study is to assess whether gradient-echo signal decays are better characterized by a standard ME decay model, or a Gaussian Augmentation of the Mono-Exponential (GAME) decay model, in the prostate at 3T. Multi-gradient-echo signals were acquired on 20 consecutive patients with a clinical suspicion of prostate cancer undergoing MR-guided prostate biopsies. Data were fitted with both ME and GAME models. The information contents of these models were compared using Akaike's information criterion (second order, AICC ), in skeletal muscle, the prostate central gland (CG), and peripheral zone (PZ) regions of interest (ROIs). The GAME model had higher information content in 30% of the prostate on average (across all patients and ROIs), covering up to 67% of cancerous PZ ROIs, and up to 100% of cancerous CG ROIs (in individual patients). The higher information content of GAME became more prominent in regions that would be assumed hypoxic using ME alone, reaching 50% of the PZ and 70% of the CG as ME R2 (*) approached 40 s(-1) . R2 (*) mapping may have important applications in MRI; however, information lost due to modeling could mask differences in parameters due to underlying tissue anatomy or physiology. The GAME model improves characterization of signal behavior in the prostate at 3T, and may increase the potential for determining correlates of fit parameters with biomarkers, for example of oxygenation status.


Asunto(s)
Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Modelos Estadísticos , Reconocimiento de Normas Patrones Automatizadas/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Anciano , Algoritmos , Simulación por Computador , Interpretación Estadística de Datos , Humanos , Masculino , Distribución Normal , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Procesamiento de Señales Asistido por Computador
10.
J Magn Reson Imaging ; 44(4): 1020-30, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-26971387

RESUMEN

PURPOSE: To assess whether R2* mapping with a standard Monoexponential (ME) or a Gaussian Augmentation of the Monoexponential (GAME) decay model better characterizes gradient-echo signal decays in gynecological cancers after external beam radiation therapy at 3T, and evaluate implications of modeling for noninvasive identification of intratumoral hypoxia. MATERIALS AND METHODS: Multi-gradient-echo signals were acquired on 25 consecutive patients with gynecologic cancers and three healthy participants during inhalation of different oxygen concentrations at 3T. Data were fitted with both ME and GAME models. Models were compared using F-tests in tumors and muscles in patients, muscles, cervix, and uterus in healthy participants, and across oxygenation levels. RESULTS: GAME significantly improved fitting over ME (P < 0.05): Improvements with GAME covered 34% of tumor regions-of-interest on average, ranging from 6% (of a vaginal tumor) to 68% (of a cervical tumor) in individual tumors. Improvements with GAME were more prominent in areas that would be assumed hypoxic based on ME alone, reaching 90% as ME R2* approached 100 Hz. Gradient echo decay parameters at different oxygenation levels were not significantly different (P = 0.81). CONCLUSION: R2* may prove sensitive to hypoxia; however, inaccurate representations of underlying data may limit the success of quantitative assessments. Although the degree to which R2 or σ values correlate with hypoxia remains unknown, improved characterization with GAME increases the potential for determining any correlates of fit parameters with biomarkers, such as oxygenation status. J. MAGN. RESON. IMAGING 2016;44:1020-1030.


Asunto(s)
Biomarcadores de Tumor/metabolismo , Neoplasias de los Genitales Femeninos/diagnóstico por imagen , Neoplasias de los Genitales Femeninos/metabolismo , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Modelos Estadísticos , Oxígeno/metabolismo , Adulto , Anciano , Simulación por Computador , Femenino , Humanos , Aumento de la Imagen/métodos , Persona de Mediana Edad , Distribución Normal , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Hipoxia Tumoral
11.
NMR Biomed ; 27(1): 3-15, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24000133

RESUMEN

It is now universally recognized that many prostate cancers are over-diagnosed and over-treated. The European Randomized Study of Screening for Prostate Cancer from 2009 evidenced that, to save one man from death from prostate cancer, over 1400 men need to be screened, and 48 need to undergo treatment. The detection of prostate cancer is traditionally based on digital rectal examination (DRE) and the measurement of serum prostate-specific antigen (PSA), followed by ultrasound-guided biopsy. The primary role of imaging for the detection and diagnosis of prostate cancer has been transrectal ultrasound (TRUS) guidance during biopsy. Traditionally, MRI has been used primarily for the staging of disease in men with biopsy-proven cancer. It has a well-established role in the detection of T3 disease, planning of radiation therapy, especially three-dimensional conformal or intensity-modulated external beam radiation therapy, and planning and guiding of interstitial seed implant or brachytherapy. New advances have now established that prostate MRI can accurately characterize focal lesions within the gland, an ability that has led to new opportunities for improved cancer detection and guidance for biopsy. Two new approaches to prostate biopsy are under investigation. Both use pre-biopsy MRI to define potential targets for sampling, and the biopsy is performed either with direct real-time MR guidance (in-bore) or MR fusion/registration with TRUS images (out-of-bore). In-bore and out-of-bore MRI-guided prostate biopsies have the advantage of using the MR target definition for the accurate localization and sampling of targets or suspicious lesions. The out-of-bore method uses combined MRI/TRUS with fusion software that provides target localization and increases the sampling accuracy of TRUS-guided biopsies by integrating prostate MRI information with TRUS. Newer parameters for each imaging modality, such as sonoelastography or shear wave elastography, contrast-enhanced ultrasound and MRI elastography, show promise to further enrich datasets.


Asunto(s)
Imagen por Resonancia Magnética , Neoplasias de la Próstata/diagnóstico por imagen , Biopsia , Diagnóstico por Imagen de Elasticidad , Humanos , Masculino , Imagen Multimodal , Próstata/diagnóstico por imagen , Próstata/patología , Radiografía
12.
Brachytherapy ; 12(3): 240-7, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23415048

RESUMEN

PURPOSE: To present outcome and toxicity results of the first real-time intraoperative MRI-guided interstitial approach to gynecologic cancer. METHODS AND MATERIALS: From February 2004 to December 2006, 25 patients with gynecologic malignancies were enrolled and treated in a prospective clinical trial of real-time MRI-guided interstitial brachytherapy. This was followed by a confirmatory CT imaging scan. Statistical analyses included Kaplan-Meier estimates for overall and relapse-free survival. RESULTS: MRI visualization of needles during placement permitted accurate placement with no inadvertent insertions. This prevented unnecessary normal-tissue perforation as confirmed by CT simulation. With a mean followup of 3.8 years (range, 2-6.8), 1-, 2-, and 3-year overall survival rates were 80%, 60% and 43%, respectively; corresponding relapse-free survival rates were 79%, 65%, and 59%, respectively. Actuarial acute toxicity rates for any grade were 0% at 0-14 days and 80% (all grade 1) at 14-90 days. Long-term (>180 days) actuarial toxicity rates were 8% gastrointestinal, 4% bladder and 4% vaginal. CONCLUSIONS: Real-time MRI guidance during insertion of interstitial needles followed by 3D-planning maximized opportunities for tumor targeting and sparing of normal tissues. Although image guidance requires additional anesthesia time, clinical outcomes indicate potential for a successful reduction in toxicity using 3D image-guided in addition to 3D image-planned brachytherapy.


Asunto(s)
Braquiterapia/métodos , Neoplasias de los Genitales Femeninos/radioterapia , Imagenología Tridimensional , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Neoplasias de los Genitales Femeninos/diagnóstico , Neoplasias de los Genitales Femeninos/epidemiología , Humanos , Massachusetts/epidemiología , Persona de Mediana Edad , Recurrencia Local de Neoplasia , Prevalencia , Estudios Prospectivos , Dosificación Radioterapéutica , Tasa de Supervivencia/tendencias , Resultado del Tratamiento
13.
Magn Reson Med ; 69(3): 749-59, 2013 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-22565377

RESUMEN

Intracavity imaging coils provide higher signal-to-noise than surface coils and have the potential to provide higher spatial resolution in shorter acquisition times. However, images from these coils suffer from physiologically induced motion artifacts, as both the anatomy and the coils move during image acquisition. We developed prospective motion-correction techniques for intracavity imaging using an array of tracking coils. The system had <50 ms latency between tracking and imaging, so that the images from the intracavity coil were acquired in a frame of reference defined by the tracking array rather than by the system's gradient coils. Two-dimensional gradient-recalled and three-dimensional electrocardiogram-gated inversion-recovery-fast-gradient-echo sequences were tested with prospective motion correction using ex vivo hearts placed on a moving platform simulating both respiratory and cardiac motion. Human abdominal tests were subsequently conducted. The tracking array provided a positional accuracy of 0.7 ± 0.5 mm, 0.6 ± 0.4 mm, and 0.1 ± 0.1 mm along the X, Y, and Z directions at a rate of 20 frames-per-second. The ex vivo and human experiments showed significant image quality improvements for both in-plane and through-plane motion correction, which although not performed in intracavity imaging, demonstrates the feasibility of implementing such a motion-correction system in a future design of combined tracking and intracavity coil.


Asunto(s)
Artefactos , Aumento de la Imagen/instrumentación , Interpretación de Imagen Asistida por Computador/instrumentación , Imagenología Tridimensional/instrumentación , Imagen por Resonancia Magnética/instrumentación , Magnetismo/instrumentación , Humanos , Movimiento (Física) , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
14.
Radiology ; 251(1): 122-33, 2009 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19332850

RESUMEN

PURPOSE: To determine the incremental benefit of combined endorectal magnetic resonance (MR) imaging and MR spectroscopic imaging, as compared with endorectal MR imaging alone, for sextant localization of peripheral zone (PZ) prostate cancer. MATERIALS AND METHODS: This prospective multicenter study, conducted by the American College of Radiology Imaging Network (ACRIN) from February 2004 to June 2005, was institutional review board approved and HIPAA compliant. Research associates were required to follow consent guidelines approved by the Office for Human Research Protection and established by the institutional review boards. One hundred thirty-four patients with biopsy-proved prostate adenocarcinoma and scheduled to undergo radical prostatectomy were recruited at seven institutions. T1-weighted, T2-weighted, and spectroscopic MR sequences were performed at 1.5 T by using a pelvic phased-array coil in combination with an endorectal coil. Eight readers independently rated the likelihood of the presence of PZ cancer in each sextant by using a five-point scale-first on MR images alone and later on combined MR-MR spectroscopic images. Areas under the receiver operating characteristic curve (AUCs) were calculated with sextant as the unit of analysis. The presence or absence of cancer at centralized histopathologic evaluation of prostate specimens was the reference standard. Reader-specific receiver operating characteristic curves for values obtained with MR imaging alone and with combined MR imaging-MR spectroscopic imaging were developed. The AUCs were estimated by using Mann-Whitney statistics and appropriate 95% confidence intervals. RESULTS: Complete data were available for 110 patients (mean age, 58 years; range, 45-72 years). MR imaging alone and combined MR imaging-MR spectroscopic imaging had similar accuracy in PZ cancer localization (AUC, 0.60 vs 0.58, respectively; P > .05). AUCs for individual readers were 0.57-0.63 for MR imaging alone and 0.54-0.61 for combined MR imaging-MR spectroscopic imaging. CONCLUSION: In patients who undergo radical prostatectomy, the accuracy of combined 1.5-T endorectal MR imaging-MR spectroscopic imaging for sextant localization of PZ prostate cancer is equal to that of MR imaging alone.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Prostatectomía , Neoplasias de la Próstata/diagnóstico , Neoplasias de la Próstata/cirugía , Anciano , Humanos , Espectroscopía de Resonancia Magnética , Masculino , Persona de Mediana Edad , Cuidados Preoperatorios , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Estados Unidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...