Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Science ; 332(6026): 216-8, 2011 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-21474755

RESUMEN

Hierarchical triple systems comprise a close binary and a more distant component. They are important for testing theories of star formation and of stellar evolution in the presence of nearby companions. We obtained 218 days of Kepler photometry of HD 181068 (magnitude of 7.1), supplemented by ground-based spectroscopy and interferometry, which show it to be a hierarchical triple with two types of mutual eclipses. The primary is a red giant that is in a 45-day orbit with a pair of red dwarfs in a close 0.9-day orbit. The red giant shows evidence for tidally induced oscillations that are driven by the orbital motion of the close pair. HD 181068 is an ideal target for studies of dynamical evolution and testing tidal friction theories in hierarchical triple systems.

2.
Phys Rev Lett ; 84(4): 658-61, 2000 Jan 24.
Artículo en Inglés | MEDLINE | ID: mdl-11017340

RESUMEN

Measurements of the beam emittance during bunch compression in the CLIC Test Facility (CTF-II) are described. The measurements were made with different beam charges and different energy correlations versus the bunch compressor settings which were varied from no compression through the point of full compression and to overcompression. Significant increases in the beam emittance were observed with the maximum emittance occurring near the point of full (maximal) compression. Finally, evaluation of possible emittance dilution mechanisms indicates that coherent synchrotron radiation was the most likely cause.

3.
Health Phys ; 71(5): 786-94, 1996 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-8887529

RESUMEN

The Final Focus Test Beam (FFTB) is a new beam line at the Stanford Linear Accelerator Center designed to test new beam optics concepts, hardware, and techniques necessary to achieve and measure the small spot sizes required for future generations of high-energy e+e- linear colliders. The FFTB takes a 47 GeVc-1, 1 kW electron beam at the end of the Stanford Linear Accelerator Center linear accelerator and transports it to the FFTB beam dump. A radiation protection system was designed and installed for the FFTB with the primary goal that the integrated dose equivalent outside the shielding resulting from beam loss would not exceed 10 mSv y-1. This system is comprised of shielding, a beam containment system and a personnel protection system. This paper presents various aspects of radiation safety at Stanford Linear Accelerator Center that were considered in the design of the FFTB radiation protection system. Beam tests were conducted in which the performance of various beam containment devices and the shielding effectiveness were evaluated. Preliminary results from these tests are presented.


Asunto(s)
Aceleradores de Partículas/normas , Monitoreo de Radiación/métodos , Protección Radiológica/métodos , California
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA