Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
J Cardiovasc Comput Tomogr ; 18(3): 304-306, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38480035

RESUMEN

BACKGROUND: ECG-gated cardiac CT is now widely used in infants with congenital heart disease (CHD). Deep Learning Image Reconstruction (DLIR) could improve image quality while minimizing the radiation dose. OBJECTIVES: To define the potential dose reduction using DLIR with an anthropomorphic phantom. METHOD: An anthropomorphic pediatric phantom was scanned with an ECG-gated cardiac CT at four dose levels. Images were reconstructed with an iterative and a deep-learning reconstruction algorithm (ASIR-V and DLIR). Detectability of high-contrast vessels were computed using a mathematical observer. Discrimination between two vessels was assessed by measuring the CT spatial resolution. The potential dose reduction while keeping a similar level of image quality was assessed. RESULTS: DLIR-H enhances detectability by 2.4% and discrimination performances by 20.9% in comparison with ASIR-V 50. To maintain a similar level of detection, the dose could be reduced by 64% using high-strength DLIR in comparison with ASIR-V50. CONCLUSION: DLIR offers the potential for a substantial dose reduction while preserving image quality compared to ASIR-V.


Asunto(s)
Técnicas de Imagen Sincronizada Cardíacas , Aprendizaje Profundo , Cardiopatías Congénitas , Fantasmas de Imagen , Valor Predictivo de las Pruebas , Dosis de Radiación , Exposición a la Radiación , Interpretación de Imagen Radiográfica Asistida por Computador , Humanos , Lactante , Exposición a la Radiación/prevención & control , Cardiopatías Congénitas/diagnóstico por imagen , Reproducibilidad de los Resultados , Electrocardiografía , Angiografía Coronaria/métodos , Angiografía por Tomografía Computarizada , Factores de Edad
2.
J Cardiovasc Magn Reson ; 26(1): 101037, 2024 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-38499269

RESUMEN

BACKGROUND: Free-running cardiac and respiratory motion-resolved whole-heart five-dimensional (5D) cardiovascular magnetic resonance (CMR) can reduce scan planning and provide a means of evaluating respiratory-driven changes in clinical parameters of interest. However, respiratory-resolved imaging can be limited by user-defined parameters which create trade-offs between residual artifact and motion blur. In this work, we develop and validate strategies for both correction of intra-bin and compensation of inter-bin respiratory motion to improve the quality of 5D CMR. METHODS: Each component of the reconstruction framework was systematically validated and compared to the previously established 5D approach using simulated free-running data (N = 50) and a cohort of 32 patients with congenital heart disease. The impact of intra-bin respiratory motion correction was evaluated in terms of image sharpness while inter-bin respiratory motion compensation was evaluated in terms of reconstruction error, compression of respiratory motion, and image sharpness. The full reconstruction framework (intra-acquisition correction and inter-acquisition compensation of respiratory motion [IIMC] 5D) was evaluated in terms of image sharpness and scoring of image quality by expert reviewers. RESULTS: Intra-bin motion correction provides significantly (p < 0.001) sharper images for both simulated and patient data. Inter-bin motion compensation results in significant (p < 0.001) lower reconstruction error, lower motion compression, and higher sharpness in both simulated (10/11) and patient (9/11) data. The combined framework resulted in significantly (p < 0.001) sharper IIMC 5D reconstructions (End-expiration (End-Exp): 0.45 ± 0.09, End-inspiration (End-Ins): 0.46 ± 0.10) relative to the previously established 5D implementation (End-Exp: 0.43 ± 0.08, End-Ins: 0.39 ± 0.09). Similarly, image scoring by three expert reviewers was significantly (p < 0.001) higher using IIMC 5D (End-Exp: 3.39 ± 0.44, End-Ins: 3.32 ± 0.45) relative to 5D images (End-Exp: 3.02 ± 0.54, End-Ins: 2.45 ± 0.52). CONCLUSION: The proposed IIMC reconstruction significantly improves the quality of 5D whole-heart MRI. This may be exploited for higher resolution or abbreviated scanning. Further investigation of the diagnostic impact of this framework and comparison to gold standards is needed to understand its full clinical utility, including exploration of respiratory-driven changes in physiological measurements of interest.

3.
J Cardiovasc Magn Reson ; 26(1): 101006, 2024 Feb 02.
Artículo en Inglés | MEDLINE | ID: mdl-38309581

RESUMEN

BACKGROUND: Four-dimensional (4D) flow magnetic resonance imaging (MRI) often relies on the injection of gadolinium- or iron-oxide-based contrast agents to improve vessel delineation. In this work, a novel technique is developed to acquire and reconstruct 4D flow data with excellent dynamic visualization of blood vessels but without the need for contrast injection. Synchronization of Neighboring Acquisitions by Physiological Signals (SyNAPS) uses pilot tone (PT) navigation to retrospectively synchronize the reconstruction of two free-running three-dimensional radial acquisitions, to create co-registered anatomy and flow images. METHODS: Thirteen volunteers and two Marfan syndrome patients were scanned without contrast agent using one free-running fast interrupted steady-state (FISS) sequence and one free-running phase-contrast MRI (PC-MRI) sequence. PT signals spanning the two sequences were recorded for retrospective respiratory motion correction and cardiac binning. The magnitude and phase images reconstructed, respectively, from FISS and PC-MRI, were synchronized to create SyNAPS 4D flow datasets. Conventional two-dimensional (2D) flow data were acquired for reference in ascending (AAo) and descending aorta (DAo). The blood-to-myocardium contrast ratio, dynamic vessel area, net volume, and peak flow were used to compare SyNAPS 4D flow with Native 4D flow (without FISS information) and 2D flow. A score of 0-4 was given to each dataset by two blinded experts regarding the feasibility of performing vessel delineation. RESULTS: Blood-to-myocardium contrast ratio for SyNAPS 4D flow magnitude images (1.5 ± 0.3) was significantly higher than for Native 4D flow (0.7 ± 0.1, p < 0.01) and was comparable to 2D flow (2.3 ± 0.9, p = 0.02). Image quality scores of SyNAPS 4D flow from the experts (M.P.: 1.9 ± 0.3, E.T.: 2.5 ± 0.5) were overall significantly higher than the scores from Native 4D flow (M.P.: 1.6 ± 0.6, p = 0.03, E.T.: 0.8 ± 0.4, p < 0.01) but still significantly lower than the scores from the reference 2D flow datasets (M.P.: 2.8 ± 0.4, p < 0.01, E.T.: 3.5 ± 0.7, p < 0.01). The Pearson correlation coefficient between the dynamic vessel area measured on SyNAPS 4D flow and that from 2D flow was 0.69 ± 0.24 for the AAo and 0.83 ± 0.10 for the DAo, whereas the Pearson correlation between Native 4D flow and 2D flow measurements was 0.12 ± 0.48 for the AAo and 0.08 ± 0.39 for the DAo. Linear correlations between SyNAPS 4D flow and 2D flow measurements of net volume (r2 = 0.83) and peak flow (r2 = 0.87) were larger than the correlations between Native 4D flow and 2D flow measurements of net volume (r2 = 0.79) and peak flow (r2 = 0.76). CONCLUSION: The feasibility and utility of SyNAPS were demonstrated for joint whole-heart anatomical and flow MRI without requiring electrocardiography gating, respiratory navigators, or contrast agents. Using SyNAPS, a high-contrast anatomical imaging sequence can be used to improve 4D flow measurements that often suffer from poor delineation of vessel boundaries in the absence of contrast agents.

4.
5.
Magn Reson Med ; 90(1): 117-132, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36877140

RESUMEN

PURPOSE: To validate a respiratory motion correction method called focused navigation (fNAV) for free-running radial whole-heart 4D flow MRI. METHODS: Using fNAV, respiratory signals derived from radial readouts are converted into three orthogonal displacements, which are then used to correct respiratory motion in 4D flow datasets. Hundred 4D flow acquisitions were simulated with non-rigid respiratory motion and used for validation. The difference between generated and fNAV displacement coefficients was calculated. Vessel area and flow measurements from 4D flow reconstructions with (fNAV) and without (uncorrected) motion correction were compared to the motion-free ground-truth. In 25 patients, the same measurements were compared between fNAV 4D flow, 2D flow, navigator-gated Cartesian 4D flow, and uncorrected 4D flow datasets. RESULTS: For simulated data, the average difference between generated and fNAV displacement coefficients was 0.04 ± $$ \pm $$ 0.32 mm and 0.31 ± $$ \pm $$ 0.35 mm in the x and y directions, respectively. In the z direction, this difference was region-dependent (0.02 ± $$ \pm $$ 0.51 mm up to 5.85 ± $$ \pm $$ 3.41 mm). For all measurements (vessel area, net volume, and peak flow), the average difference from ground truth was higher for uncorrected 4D flow datasets (0.32 ± $$ \pm $$ 0.11 cm2 , 11.1 ± $$ \pm $$ 3.5 mL, and 22.3 ± $$ \pm $$ 6.0 mL/s) than for fNAV 4D flow datasets (0.10 ± $$ \pm $$ 0.03 cm2 , 2.6 ± $$ \pm $$ 0.7 mL, and 5.1 ± 0 $$ \pm 0 $$ .9 mL/s, p < 0.05). In vivo, average vessel area measurements were 4.92 ± $$ \pm $$ 2.95 cm2 , 5.06 ± $$ \pm $$ 2.64 cm2 , 4.87 ± $$ \pm $$ 2.57 cm2 , 4.87 ± $$ \pm $$ 2.69 cm2 , for 2D flow and fNAV, navigator-gated and uncorrected 4D flow datasets, respectively. In the ascending aorta, all 4D flow datasets except for the fNAV reconstruction had significantly different vessel area measurements from 2D flow. Overall, 2D flow datasets demonstrated the strongest correlation to fNAV 4D flow for both net volume (r2  = 0.92) and peak flow (r2  = 0.94), followed by navigator-gated 4D flow (r2  = 0.83 and r2  = 0.86, respectively), and uncorrected 4D flow (r2  = 0.69 and r2  = 0.86, respectively). CONCLUSION: fNAV corrected respiratory motion in vitro and in vivo, resulting in fNAV 4D flow measurements that are comparable to those derived from 2D flow and navigator-gated Cartesian 4D flow datasets, with improvements over those from uncorrected 4D flow.


Asunto(s)
Imagen por Resonancia Magnética , Frecuencia Respiratoria , Humanos , Imagen por Resonancia Magnética/métodos , Movimiento (Física) , Aorta , Imagenología Tridimensional/métodos
6.
Antibiotics (Basel) ; 12(3)2023 Mar 02.
Artículo en Inglés | MEDLINE | ID: mdl-36978363

RESUMEN

Guidelines recommend chest X-rays (CXRs) to diagnose pneumonia and guide antibiotic treatment. This study aimed to identify clinical predictors of pneumonia that are visible on a chest X-ray (CXR+) which could support ruling out pneumonia and avoiding unnecessary CXRs, including oxygen saturation. A secondary analysis was performed in a clinical trial that included patients with suspected pneumonia in Swiss primary care. CXRs were reviewed by two radiologists. We evaluated the association between clinical signs (heart rate > 100/min, respiratory rate ≥ 24/min, temperature ≥ 37.8 °C, abnormal auscultation, and oxygen saturation < 95%) and CXR+ using multivariate analysis. We also calculated the diagnostic performance of the associated clinical signs combined in a clinical decision rule (CDR), as well as a CDR derived from a large meta-analysis (at least one of the following: heart rate > 100/min, respiratory rate ≥ 24/min, temperature ≥ 37.8 °C, or abnormal auscultation). Out of 469 patients from the initial trial, 107 had a CXR and were included in this study. Of these, 26 (24%) had a CXR+. We found that temperature and oxygen saturation were associated with CXR+. A CDR based on the presence of either temperature ≥ 37.8 °C and/or an oxygen saturation level < 95% had a sensitivity of 69% and a negative likelihood ratio (LR-) of 0.45. The CDR from the meta-analysis had a sensitivity of 92% and an LR- of 0.37. The addition of saturation < 95% to this CDR increased the sensitivity (96%) and decreased the LR- (0.21). In conclusion, this study suggests that pulse oximetry could be added to a simple CDR to decrease the probability of pneumonia to an acceptable level and avoid unnecessary CXRs.

7.
Front Pediatr ; 10: 898402, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36090566

RESUMEN

Background: The utilization of contrast-enhanced computed tomography (CT) of the chest for the diagnosis of necrotizing pneumonia (NP), a complication of community-acquired pneumonia, is controversial because of the inherent ionizing radiation involved. Over the past few years, the growing availability of bedside Lung Ultrasound (LUS) devices has led to increased use of this nonionizing imaging method for diagnosing thoracic pathology, including pneumonia. Objective: The objectives of this study were as follows: first, to compare the performance of LUS vs. CT in the identification of certain radiological signs of NP, and second, to determine whether LUS could replace CT in the diagnosis of NP. Materials and methods: We compared retrospectively the CT and LUS images of 41 patients between 2005 and 2018 in whom at least one contrast-injected chest CT scan and one LUS had been undertaken fewer than 7 days apart. Results: Pleural effusions were demonstrated almost systematically (100% on CT vs. 95.8% on LUS). Visualization of septations in pleural effusions was clearly superior on LUS (20.4% on CT vs 62.5% on LUS). Concerning the detection of necrosis, we observed a strong correlation between LUS and the gold-standard CT (95.8% on LUS vs. 93.7% on CT). Parenchymal cavities were more easily detected on CT than on LUS (79.1 vs. 35.4%). Conclusion: LUS has shown to be as effective as CT in the diagnosis of NP. The use of CT in patients with NP could be limited to the detection of complications such as bronchopleural fistulae in unfavorably evolving diseases.

8.
BMC Infect Dis ; 22(1): 39, 2022 Jan 06.
Artículo en Inglés | MEDLINE | ID: mdl-34991507

RESUMEN

BACKGROUND: Inappropriate antibiotics use in lower respiratory tract infections (LRTI) is a major contributor to resistance. We aimed to design an algorithm based on clinical signs and host biomarkers to identify bacterial community-acquired pneumonia (CAP) among patients with LRTI. METHODS: Participants with LRTI were selected in a prospective cohort of febrile (≥ 38 °C) adults presenting to outpatient clinics in Dar es Salaam. Participants underwent chest X-ray, multiplex PCR for respiratory pathogens, and measurements of 13 biomarkers. We evaluated the predictive accuracy of clinical signs and biomarkers using logistic regression and classification and regression tree analysis. RESULTS: Of 110 patients with LRTI, 17 had bacterial CAP. Procalcitonin (PCT), interleukin-6 (IL-6) and soluble triggering receptor expressed by myeloid cells-1 (sTREM-1) showed an excellent predictive accuracy to identify bacterial CAP (AUROC 0.88, 95%CI 0.78-0.98; 0.84, 0.72-0.99; 0.83, 0.74-0.92, respectively). Combining respiratory rate with PCT or IL-6 significantly improved the model compared to respiratory rate alone (p = 0.006, p = 0.033, respectively). An algorithm with respiratory rate (≥ 32/min) and PCT (≥ 0.25 µg/L) had 94% sensitivity and 82% specificity. CONCLUSIONS: PCT, IL-6 and sTREM-1 had an excellent predictive accuracy in differentiating bacterial CAP from other LRTIs. An algorithm combining respiratory rate and PCT displayed even better performance in this sub-Sahara African setting.


Asunto(s)
Neumonía Bacteriana , Infecciones del Sistema Respiratorio , Algoritmos , Biomarcadores , Proteína C-Reactiva/análisis , Humanos , Pacientes Ambulatorios , Neumonía Bacteriana/diagnóstico , Estudios Prospectivos , Infecciones del Sistema Respiratorio/diagnóstico , Tanzanía
9.
J Cancer Sci Clin Ther ; 6(4): 452-459, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36938135

RESUMEN

Objectives: The aim of this study was to assess the diagnostic performance of abbreviated MRI (AMRI) using the maximal intensity projection (MIP) reconstruction of the first post-contrast acquisition subtracted (FAST) compared with MIP+FAST and full-protocol MRI (fpMRI) for the preoperative assessment of breast cancer (BC) in a biopsy-proven cancer population. Methods: In this monocentric retrospective study, two readers consensually assessed two AMRI protocols consisting of MIP reconstruction of the FAST (MIP) and MIP+FAST. 228 patients were included with a breast MRI performed between 2013 and 2014, 207 of them (90.8%) had biopsy-proven cancer with 256 lesions. Data of MIP and MIP+FAST were compared to full-protocol MRI (fpMRI) reading and to the reference standard including 6-month follow-up imaging and pathology as the reference. Results: MIP, MIP+FAST and fpMRI demonstrated a per-lesion sensitivity for BC detection of 87.5% (224/256, 95%CI: 82.9-91.3%) and 97.7% (250/256, 95-99.1%) and 98.4% (252/256, 96.1-99.6%), respectively with a statistical difference between MIP compared to MIP+FAST and fpMRI when considering confidence intervals. Per-lesion specificity was not different [MIP: 47.6% (10/21, 25.7-70.2%), MIP+FAST: 52.4% (11/21,29.8-74.3%, fpMRI: 66.7% (14/21, 43-85.4%)]. Conclusion: AMRI using only MIP is not accurate for the pre-operative assessment of BC due to lower sensitivity when compared to MIP+FAST and fpMRI. AMRI using the MIP+FAST acquisition in the preoperative setting seems promising as it could be used as the same protocol for both screening and staging in case of positive cases, without need for a recall fpMRI. This needs confirmation with cohort including higher rate of negative cases in order to evaluate the specificity.

10.
JMIR Med Educ ; 7(4): e31132, 2021 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-34723818

RESUMEN

BACKGROUND: Teaching medical ultrasound has increased in popularity in medical schools with hands-on workshops as an essential part of teaching. However, the lockdown due to COVID-19 kept medical schools from conducting these workshops. OBJECTIVE: The aim of this paper is to describe an alternative method used by our medical school to allow our students to acquire the essential psychomotor skills to produce ultrasound images. METHODS: Our students took online ultrasound courses. Consequently, they had to practice ultrasound exercises on a virtual simulator, using the mouse of their computer to control a simulated transducer. Our team measured the precision reached at the completion of simulation exercises. Before and after completion of the courses and simulator's exercises, students had to complete a questionnaire dedicated to psychomotor skills. A general evaluation questionnaire was also submitted. RESULTS: A total of 193 students returned the precourse questionnaire. A total of 184 performed all the simulator exercises and 181 answered the postcourse questionnaire. Of the 180 general evaluation questionnaires that were sent out, 136 (76%) were returned. The average precourse score was 4.23 (SD 2.14). After exercising, the average postcourse score was 6.36 (SD 1.82), with a significant improvement (P<.001). The postcourse score was related to the accuracy with which the simulator exercises were performed (Spearman rho 0.2664; P<.001). Nearly two-thirds (n=84, 62.6%) of the students said they enjoyed working on the simulator. A total of 79 (58.0%) students felt that they had achieved the course's objective of reproducing ultrasound images. Inadequate connection speed had been a problem for 40.2% (n=54) of students. CONCLUSIONS: The integration of an online simulator for the practical learning of ultrasound in remote learning situations has allowed for substantial acquisitions in the psychomotor field of ultrasound diagnosis. Despite the absence of workshops, the students were able to learn and practice how to handle an ultrasound probe to reproduce standard images. This study enhances the value of online programs in medical education, even for practical skills.

11.
Clin Imaging ; 77: 92-97, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33662713

RESUMEN

PURPOSES: The classification of lung sequestrations distinguishes between extralobar and intralobar types, according to their venous drainage - systemic vs pulmonary - and the presence or absence of independent pleura. However, imaging, surgical and/or pathological findings often differ from this description. The objectives of this article are to quantify the percentage of lung sequestrations that do not fit the classic description of extra- and intralobar types and to evaluate the accuracy of the currently used classification. METHODS: A retrospective search identified all children with a confirmed lung sequestration diagnosed and treated in our Hospital over the last 10 years. Two senior pediatric radiologists reviewed their contrast-enhanced computed tomography chest scans and evaluated the main anatomical features that define sequestrations, including pleura, arterial and venous pattern, airways and lung parenchyma. We compared the imaging-, surgical- and pathological findings to those described for extra- and intralobar sequestrations. RESULTS: 25 children (20 M, 5 F) conform the series. Only 13 lesions (52%) filled all criteria described for an extra- or intralobar sequestration. The remaining 12 lesions (48%) had at least one differing criteria, including incomplete independent pleura (n = 2; 8%), mixed systemic and pulmonary arterial supply (n = 1; 4%) or venous drainage (n = 3; 12%), normal connection to airway (n = 1; 4%) and/or coexistent congenital lung anomalies (n = 11; 44%). CONCLUSION: Lung sequestrations seem to represent a spectrum of anomalies rather than separated entities. Therefore, a detailed description of their main anatomical features could be more relevant for clinicians and surgeons that the rigid distinction in intra- and extralobar sequestration currently applied.


Asunto(s)
Secuestro Broncopulmonar , Secuestro Broncopulmonar/diagnóstico por imagen , Secuestro Broncopulmonar/cirugía , Niño , Humanos , Pulmón/diagnóstico por imagen , Pleura , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
12.
Pediatr Radiol ; 50(1): 57-67, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31482265

RESUMEN

BACKGROUND: Anorectal malformation is a spectrum of congenital defects of the distal bowel, mostly diagnosed at birth. OBJECTIVE: To describe the prenatal imaging findings of anorectal malformations, explore the causes of the low rates of prenatal diagnosis, compare the accuracy of prenatal ultrasound (US) and magnetic resonnance imaging [MRI] and evaluate the relevance of information obtained at MRI. MATERIALS AND METHODS: Children treated for anorectal malformation at our hospital and with available prenatal studies were retrospectively identified and included in the study. We reviewed prenatal imaging exams, listed findings suggestive of the diagnosis, and compared results with the final classification. RESULTS: Fourteen fetuses and neonates - eight with intermediate-high type anorectal malformation and six with cloacae - fulfilled the inclusion criteria. All had associated congenital anomalies. Prenatal exams included 13 US and 8 MRI exams, with 7 children having both exams. Suggestive findings for anorectal malformation were detected in 50% of the cases prenatally and in 85% upon review. They were prospectively detected in 31% and 50% of the cases at US and MRI and retrospectively in 62% and 100% at US and MRI, respectively. MRI was superior to US because it improved the diagnosis, especially in cloacae, and provided relevant additional information that changed management in two cases. CONCLUSION: The most important signs suggesting anorectal malformation are an absent target sign and anomalous distal bowel wall and rectal fluid. Complementary prenatal MRI improves the diagnosis of anorectal malformation.


Asunto(s)
Malformaciones Anorrectales/diagnóstico por imagen , Malformaciones Anorrectales/embriología , Imagen por Resonancia Magnética/métodos , Ultrasonografía Prenatal/métodos , Femenino , Humanos , Recién Nacido , Masculino , Embarazo , Diagnóstico Prenatal/métodos , Estudios Prospectivos , Recto/anomalías , Recto/diagnóstico por imagen , Recto/embriología , Reproducibilidad de los Resultados , Estudios Retrospectivos , Suiza , Centros de Atención Terciaria
13.
Cardiol Young ; 27(9): 1740-1747, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28673366

RESUMEN

OBJECTIVES: Tetralogy of Fallot with absent pulmonary valve syndrome is a rare form of tetralogy of Fallot with dilatation of large pulmonary arteries. Prognosis is related to the severity of the cardiac malformation and to bronchial tree compression by dilated pulmonary arteries. This study analyses the prenatal echographic lung appearance in fetuses with tetralogy of Fallot with absent pulmonary valve and discusses its significance. METHODS: We carried out a retrospective review of fetal and postnatal files of nine fetuses diagnosed with tetralogy of Fallot with absent pulmonary valve syndrome in our institution. Correlations of prenatal ultrasound and cardiac imaging findings were obtained with outcome. RESULTS: Abnormal heterogeneous fetal lung echogenicity was detected in eight cases out of nine, always associated with significant lobar arterial dilatation. This aspect was well correlated with postnatal imaging and outcome in the four neonatal cases. The only fetus with normal lung echogenicity also had lower degree of pulmonary artery dilatation in the series. CONCLUSIONS: This study demonstrates that a heterogeneous ultrasound appearance of the fetal lungs can be detected in utero in the most severe cases. This aspect suggests an already significant compression of the fetal bronchial tree by the dilated arteries that may have prognostic implications.


Asunto(s)
Enfermedades de las Válvulas Cardíacas/congénito , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Válvula Pulmonar/anomalías , Válvula Pulmonar/diagnóstico por imagen , Tetralogía de Fallot/diagnóstico por imagen , Bases de Datos Factuales , Ecocardiografía , Femenino , Feto , Enfermedades de las Válvulas Cardíacas/complicaciones , Humanos , Recién Nacido , Cariotipo , Pulmón/anomalías , Pulmón/diagnóstico por imagen , Embarazo , Pronóstico , Estudios Retrospectivos , Centros de Atención Terciaria , Tetralogía de Fallot/complicaciones , Ultrasonografía Prenatal
14.
J Pediatr ; 166(5): 1140-1144.e2, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25720367

RESUMEN

OBJECTIVE: To report the incidence of congenital vascular anomalies in a cohort of patients with esophageal atresia (EA) and tracheoesophageal fistula (TEF) while describing the clinical presentation, diagnosis, and consequences, and to evaluate the diagnostic value of esophagram in diagnosing an aberrant right subclavian artery (ARSA). METHODS: All patients born with EA/TEF between 2005 and 2013 were studied. Preoperative echocardiography reports, surgical descriptions of primary esophageal repair, and esophagrams were reviewed retrospectively. RESULTS: Of the 76 children born with EA/TEF included in this study, 14 (18%) had a vascular malformation. The incidence of a right aortic arch (RAA) was 6% (5 of 76), and that of an aberrant right subclavian artery (ARSA) was 12% (9 of 76). RAA was diagnosed in the neonatal period by echocardiography (4 of 5) or surgery (1 of 5), and ARSA was diagnosed by echocardiography (7 of 9) or later on the esophagram (2 of 9). Respiratory and/or digestive symptoms occurred in 9 of the 14 patients with vascular malformation. Both long-gap EA and severe cardiac malformations necessitating surgery were significantly associated with vascular anomalies (P<.05). The sensitivity of the esophagram for diagnosing ARSA was 66%, the specificity was 98%, the negative predictive value was 95%, and the positive predictive value was 85%. CONCLUSION: ARSA and RAA have an incidence of 12% and 6% respectively, in patients with EA/TEF. A computed tomography angioscan is recommended to rule out such malformations when stenting of the esophagus is indicated, before esophageal replacement surgery, and when prolonged (>2 weeks) use of a nasogastric tube is considered.


Asunto(s)
Atresia Esofágica/complicaciones , Fístula Traqueoesofágica/complicaciones , Malformaciones Vasculares/complicaciones , Aorta Torácica/anomalías , Niño , Preescolar , Ecocardiografía , Esófago/anomalías , Femenino , Humanos , Masculino , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Arteria Subclavia/patología
15.
Pediatr Radiol ; 44(12): 1518-31, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25030219

RESUMEN

BACKGROUND: The Contegra® is a conduit made from the bovine jugular vein and then interposed between the right ventricle and the pulmonary artery. It is used for cardiac malformations in the reconstruction of right ventricular outflow tract. OBJECTIVE: To describe both normal and pathological appearances of the Contegra® in radiological imaging, to describe imaging of complications and to define the role of CT and MRI in postoperative follow-up. MATERIALS AND METHODS: Forty-three examinations of 24 patients (17 boys and 7 girls; mean age: 10.8 years old) with Contegra® conduits were reviewed. Anatomical description and measurements of the conduits were performed. Pathological items examined included stenosis, dilatation, plicature or twist, thrombus or vegetations, calcifications and valvular regurgitation. Findings were correlated to the echographic gradient through the conduit when available. RESULTS: CT and MR work-up showed Contegra® stenosis (n = 12), dilatation (n = 9) and plicature or twist (n = 7). CT displayed thrombus or vegetations in the Contegra® in three clinically infected patients. Calcifications of the conduit were present at CT in 12 patients and valvular regurgitation in three patients. The comparison between CT and/or MR results showed a good correlation between the echographic gradient and the presence of stenosis in the Contegra®. CONCLUSION: CT and MR bring additional information about permeability and postoperative anatomy especially when echocardiography is inconclusive. Both techniques depict the normal appearance of the conduit, and allow comparison and precise evaluation of changes in the postoperative follow-up.


Asunto(s)
Análisis de Falla de Equipo/métodos , Cardiopatías Congénitas/terapia , Enfermedades de las Válvulas Cardíacas/diagnóstico , Prótesis Valvulares Cardíacas/efectos adversos , Complicaciones Posoperatorias/diagnóstico , Válvula Pulmonar/diagnóstico por imagen , Obstrucción del Flujo Ventricular Externo/diagnóstico , Adolescente , Animales , Bovinos , Niño , Preescolar , Femenino , Enfermedades de las Válvulas Cardíacas/etiología , Enfermedades de las Válvulas Cardíacas/terapia , Ventrículos Cardíacos/anomalías , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/patología , Humanos , Lactante , Venas Yugulares/trasplante , Imagen por Resonancia Magnética/métodos , Masculino , Válvula Pulmonar/trasplante , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Válvula Tricúspide/trasplante , Obstrucción del Flujo Ventricular Externo/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...