Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Cornea ; 43(4): 409-418, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-37643477

RESUMEN

PURPOSE: The aim of this study was to investigate age-related changes in corneal nerves and corneal epithelial cell parameters and to establish age-adjusted reference values. METHODS: A total of 7025 corneal nerve images and 4215 corneal epithelial images obtained using in vivo confocal microscopy from 281 eyes of 143 healthy participants were included. Seven corneal nerve parameters and 3 corneal epithelial cell parameters were quantified using 2 automatic analytic software and analyzed across 6 age groups ranging from 21 to 80 years. RESULTS: There was a declining trend in all 7 nerve parameters with advancing age. In particular, corneal nerve fiber length and corneal nerve fiber density demonstrated a significant decrease in subjects aged 65 years or older compared with subjects younger than 65 years (10.8 ± 2.6 mm/mm 2 vs. 9.9 ± 2.0 mm/mm 2 , P = 0.011 in corneal nerve fiber length; 15.8 ± 5.2 fibers/mm 2 vs. 14.4 ± 4.3 fibers/mm 2 , P = 0.046 in corneal nerve fiber density), whereas corneal nerve fractal dimension demonstrated a borderline significant decrease ( P = 0.057). Similarly, there was a general declining trend in all epithelial cell parameters with advancing age. Corneal epithelial cell circularity was significantly lower in subjects aged 65 years and older as compared to subjects younger than 65 years (0.722 ± 0.021 µm 2 vs. 0.714 ± 0.021 µm 2 ; P = 0.011). CONCLUSIONS: Advancing age results in reduced corneal nerve metrics and alteration of corneal cell morphology. Aging effects should be considered when evaluating patients with corneal neuropathy.


Asunto(s)
Córnea , Fibras Nerviosas , Adulto , Humanos , Córnea/inervación , Células Epiteliales , Microscopía Confocal/métodos , Recuento de Células
2.
Ophthalmol Retina ; 6(11): 1080-1088, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35580772

RESUMEN

OBJECTIVE: To describe the normative quantitative parameters of the macular retinal vasculature, as well as their systemic and ocular associations using OCT angiography (OCTA). DESIGN: Population-based, cross-sectional study. SUBJECTS: Adults aged > 50 years were recruited from the third examination of the population-based Singapore Malay Eye Study. METHODS: All participants underwent a standardized comprehensive examination and spectral-domain OCTA (Optovue) of the macula. OCT angiography scans that revealed pre-existing retinal disease, revealed macular pathology, and had poor quality were excluded. MAIN OUTCOME MEASURES: The normative quantitative vessel densities of the superficial layer, deep layer, and foveal avascular zone (FAZ) were evaluated. Ocular and systemic associations with macular retinal vasculature parameters were also evaluated in a multivariable analysis using linear regression models with generalized estimating equation models. RESULTS: We included 1184 scans (1184 eyes) of 749 participants. The mean macular superficial vessel density (SVD) and deep vessel density (DVD) were 45.1 ± 4.2% (95% confidence interval [CI], 37.8%-51.4%) and 44.4 ± 5.2% (95% CI, 36.9%-53.2%), respectively. The mean SVD and DVD were highest in the superior quadrant (48.7 ± 5.9%) and nasal quadrant (52.7 ± 4.6%), respectively. The mean FAZ area and perimeter were 0.32 ± 0.11 mm2 (95% CI, 0.17-0.51 mm) and 2.14 ± 0.38 mm (95% CI, 1.54-2.75 mm), respectively. In the multivariable regression analysis, female sex was associated with higher SVD (ß = 1.25, P ≤ 0.001) and DVD (ß = 0.75, P = 0.021). Older age (ß = -0.67, P < 0.001) was associated with lower SVD, whereas longer axial length (ß = -0.42, P = 0.003) was associated with lower DVD. Female sex, shorter axial length, and worse best-corrected distance visual acuity were associated with a larger FAZ area. No association of a range of systemic parameters with vessel density was found. CONCLUSIONS: This study provided normative macular vasculature parameters in an adult Asian population, which may serve as reference values for quantitative interpretation of OCTA data in normal and disease states.


Asunto(s)
Tomografía de Coherencia Óptica , Adulto , Femenino , Humanos , Angiografía con Fluoresceína , Estudios Transversales , Malasia , Singapur/epidemiología
4.
Sci Rep ; 11(1): 10795, 2021 05 24.
Artículo en Inglés | MEDLINE | ID: mdl-34031469

RESUMEN

This study aimed to determine COVID-19-related awareness, knowledge, impact and preparedness among elderly Asians; and to evaluate their acceptance towards digital health services amidst the pandemic. 523 participants (177 Malays, 171 Indians, 175 Chinese) were recruited and underwent standardised phone interview during Singapore's lockdown period (07 April till 01 June 2020). Multivariable logistic regression models were performed to evaluate the associations between demographic, socio-economic, lifestyle, and systemic factors, with COVID-19 awareness, knowledge, preparedness, well-being and digital health service acceptance. The average perception score on the seriousness of COVID-19 was 7.6 ± 2.4 (out of 10). 75.5% of participants were aware that COVID-19 carriers can be asymptomatic. Nearly all (≥ 90%) were aware of major prevention methods for COVID-19 (i.e. wearing of mask, social distancing). 66.2% felt prepared for the pandemic, and 86.8% felt confident with government's handling and measures. 78.4% felt their daily routine was impacted. 98.1% reported no prior experience in using digital health services, but 52.2% felt these services would be helpful to reduce non-essential contact. 77.8% were uncomfortable with artificial intelligence software interpreting their medical results. In multivariable analyses, Chinese participants felt less prepared, and more likely felt impacted by COVID-19. Older and lower income participants were less likely to use digital health services. In conclusion, we observed a high level of awareness and knowledge on COVID-19. However, acceptance towards digital health service was low. These findings are valuable for examining the effectiveness of COVID-19 communication in Singapore, and the remaining gaps in digital health adoption among elderly.


Asunto(s)
Concienciación , COVID-19/patología , Conocimiento , Percepción , Telemedicina , Anciano , COVID-19/epidemiología , COVID-19/virología , Estudios Transversales , Atención a la Salud , Etnicidad/psicología , Femenino , Humanos , Entrevistas como Asunto , Masculino , Persona de Mediana Edad , SARS-CoV-2/aislamiento & purificación , Singapur/epidemiología , Factores Socioeconómicos , Encuestas y Cuestionarios , Teléfono , Población Urbana
7.
Sci Rep ; 10(1): 8345, 2020 05 20.
Artículo en Inglés | MEDLINE | ID: mdl-32433483

RESUMEN

We evaluated the agreements in foveal avascular zone (FAZ) area and vessel density (VD) parameters (within the superficial capillary plexus region), between two widely used optical coherence tomography angiography machines. Participants who attended the Singapore Malay Eye Study III between 29th March and 6th August 2018, were enrolled in this study. Participants underwent fovea-centered 6×6-mm macular cube scan, using both AngioVue and Cirrus HDOCT machines. Scans were analyzed automatically using built-in review software of each machine. 177 eyes (95 participants) without retinal diseases were included for final analysis. Mean FAZ area was 0.38 ± 0.11 mm2 and 0.30 ± 0.10 mm2, based on AngioVue and Cirrus HDOCT, respectively. Mean parafoveal VD was 0.50 ± 0.04 in Angiovue, and 0.43 ± 0.04 in Cirrus HDOCT. Cirrus HDOCT measurements were consistently lower than those by AngioVue, with a mean difference of -0.08 (95% limits of agreement [LOA], -0.30-0.13) mm2 for FAZ area, and -0.07 (95% LOA, -0.17-0.03) for parafoveal VD. Intraclass correlation coefficients for FAZ area and parafoveal VD were 0.33 and 0.07, respectively. Our data suggest that agreements between AngioVue and Cirrus HDOCT machines were poor to fair, thus alternating use between these two machines may not be recommended especially for follow up evaluations.


Asunto(s)
Angiografía con Fluoresceína/instrumentación , Fóvea Central/irrigación sanguínea , Vasos Retinianos/diagnóstico por imagen , Tomografía de Coherencia Óptica/instrumentación , Anciano , Estudios de Casos y Controles , Estudios Transversales , Femenino , Angiografía con Fluoresceína/estadística & datos numéricos , Fóvea Central/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Singapur , Tomografía de Coherencia Óptica/estadística & datos numéricos , Agudeza Visual
8.
Br J Ophthalmol ; 104(5): 610-615, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-31401553

RESUMEN

BACKGROUND/AIMS: In order to address the eye care needs of the increasing numbers of elderly Chinese globally, there is a need for comprehensive understanding on the longitudinal trends of age-related eye diseases among Chinese. We herein report the key findings from the baseline Singapore Chinese Eye Study (SCES-1), and describe the rationale and methodology of the 6-year follow-up study (SCES-2). METHODS: 3353 Chinese adults who participated in the baseline SCES-1 (2009-2011) were invited for the 6-year follow-up SCES-2 (2015-2017). Examination procedures for SCES-2 included standardised ocular, systemic examinations and questionnaires identical to SCES-1. SCES-2 further included new examinations such as optical coherence tomography angiography, and questionnaires to evaluate health impact and economic burden of eye diseases. RESULTS: In SCES-1, the age-adjusted prevalence of best-corrected low vision (VA<6/12, better-seeing eye) and blindness (VA<6/60, better-seeing eye) were 3.4% and 0.2%, respectively. The prevalence rates for glaucoma, age related macular degeneration, and diabetic retinopathy (among diabetics) were 3.2%, 6.8%, 26.2%, respectively. Of the 3033 eligible individuals from SCES-1, 2661 participated in SCES-2 (response rate=87.7%). Comparing with those who did not attend SCES-2, those attended were younger, had higher SES (all p<0.001), but less likely to be a current smoker, to have diabetes, hypertension, hyperlipidaemia (all p≤0.025). CONCLUSIONS: Building on SCES-1, SCES-2 will be one of the few longitudinal population-based eye studies to report incidence, progression, and risk factors of major age-related eye diseases. Findings from this cohort may offer new insights, and provide useful reference information for other Chinese populations elsewhere.


Asunto(s)
Oftalmopatías/epidemiología , Angiografía con Fluoresceína/métodos , Tomografía de Coherencia Óptica/métodos , Agudeza Visual , Adulto , Distribución por Edad , Anciano , Anciano de 80 o más Años , China/epidemiología , Estudios Transversales , Oftalmopatías/diagnóstico , Femenino , Estudios de Seguimiento , Fondo de Ojo , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Prevalencia , Estudios Retrospectivos , Factores de Riesgo , Distribución por Sexo , Singapur/epidemiología , Encuestas y Cuestionarios , Factores de Tiempo , Personas con Daño Visual/estadística & datos numéricos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...