Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
J Cardiovasc Magn Reson ; 24(1): 67, 2022 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-36451214

RESUMEN

BACKGROUND: Methamphetamine-associated cardiomyopathy (MA-CMP) is an increasingly recognised aetiology of cardiomyopathy. Cardiovascular magnetic resonance (CMR) is a specialised cardiac imaging modality commonly used in assessment of cardiomyopathy. We aimed to identify specific CMR features associated with MA-CMP. METHODS: A retrospective cohort study of CMR scans was performed in a single centre between January 2015 and December 2020. Thirty patients with MA-CMP who had undergone CMR were identified. MA-CMP was defined as those with a history of significant methamphetamine use hospitalised with acute decompensated heart failure (other causes of cardiomyopathy excluded). A retrospective analysis of index admission CMRs was performed. All studies were performed on a 1.5 T CMR scanner. RESULTS: The mean age of MA-CMP patients was 43.7 ± 7.5 years, and 86.7% were male. The mean left ventricular (LV) volume obtained in this cohort was consistent with severe LV dilatation (LV end-diastolic volume (334 ± 99 ml); LV end-systolic volume: 269 ± 98 ml), whilst the right ventricular (RV) volume indicated moderate-to-severe dilatation (RV end-diastolic volume: 272 ± 91 ml; RV end-systolic volume: 173 ± 82 ml). Mean LV ejection fraction (20.9 ± 9.2%) indicated severe LV dysfunction, with moderate-to-severe RV dysfunction also detected (RV ejection fraction: 29.4 ± 13.4%). 22 patients (73.3%) had myocardial late gadolinium enhancement (LGE), of which 59.1% were located in the mid-wall, with all of these involving the interventricular septum. 22.7% displayed localised regions of sub-endocardial LGE in a variety of locations, and 18.2% had transmural regions of LGE that were located in the inferior and inferolateral segments. 6 patients (20%) had intracardiac thrombus (4 LV, 2 both LV and RV). CONCLUSION: MA-CMP was associated with severe biventricular dilatation and dysfunction, with a high prevalence of intraventricular thrombus. This cohort study highlights that MA-CMP patients have a high prevalence of CMR findings.


Asunto(s)
Cardiomiopatías , Insuficiencia Cardíaca , Metanfetamina , Tabique Interventricular , Humanos , Masculino , Adulto , Persona de Mediana Edad , Femenino , Estudios Retrospectivos , Metanfetamina/efectos adversos , Estudios de Cohortes , Medios de Contraste/efectos adversos , Gadolinio , Valor Predictivo de las Pruebas , Cardiomiopatías/inducido químicamente , Cardiomiopatías/diagnóstico por imagen , Imagen por Resonancia Magnética , Ventrículos Cardíacos , Insuficiencia Cardíaca/inducido químicamente , Insuficiencia Cardíaca/diagnóstico por imagen , Citidina Monofosfato
2.
Kidney Int Rep ; 6(1): 120-127, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33426391

RESUMEN

BACKGROUND: Cardiovascular events remain a major cause of death in kidney transplant recipients. The optimal noninvasive workup to prevent peritransplant cardiac mortality remains contentious. METHODS: We conducted a retrospective analysis to assess the renal transplantation cardiovascular assessment protocol within a single-center population over a 5-year period. Asymptomatic patients aged less than 45 years with no history of cigarette smoking, without diabetes mellitus, and dialysis-dependent for less than 24 months did not undergo cardiac testing before listing. All other asymptomatic patients underwent a noninvasive, tachycardia-induced stress test, where a target heart rate of 85% predicted for age and gender was required. The primary endpoints were rates of acute myocardial infarction (AMI) and cardiovascular death at 30 days after renal transplantation. RESULTS: Between 2015 and 2019, 380 recipients underwent cardiac evaluation: 79 (20.8%) were deemed low cardiovascular risk and placed on the renal transplant waitlist without further assessment; 270 (71.1%) underwent a tachycardia-induced stress test; and 31 (8.1%) were deemed high risk and proceeded directly to invasive coronary angiography (ICA). In the 5-year follow-up, 3 patients (0.8%) experienced an AMI 30 days after renal transplantation, all of which occurred in the high-risk "direct to ICA" cohort. No events were documented in the low-risk cohort or in patients who had a negative tachycardia-induced stress test. There were no cardiovascular deaths within 30 days after transplantation. CONCLUSION: A negative tachycardia-induced cardiac stress test, achieving 85% of predicted heart rate, was associated with a 0% AMI rate and no cardiovascular deaths at 30 days after renal transplantation.

3.
Kidney360 ; 2(7): 1141-1147, 2021 07 29.
Artículo en Inglés | MEDLINE | ID: mdl-35368362

RESUMEN

Background: The long-term effects of arteriovenous fistula (AVF) ligation on cardiovascular structure following kidney transplantation remain uncertain. A prospective randomized, controlled trial (RCT) examined the effect of AVF ligation at 6 months on cardiovascular magnetic resonance imaging (CMR)-derived parameters in 27 kidney transplant recipients compared with 27 controls. A mean decrease in left ventricular mass (LVM) of 22.1 g (95% CI, 15.0 to 29.1) was observed compared with an increase of 1.2 g (95% CI, -4.8 to 7.2) in the control group (P<0.001). We conducted a long-term follow-up observational cohort study in the treated cohort to determine the evolution of CMR-derived parameters compared with those documented at 6 months post-AVF ligation. Methods: We performed CMR at long-term follow-up in the AVF ligation observational cohort from our original RCT published in 2019. Results were compared with CMR at 6 months postintervention. The coprimary end point was the change in CMR-derived LVM and LVM index at long-term follow-up from imaging at 6 months postindex procedure. Results: At a median of 5.1 years (interquartile range, 4.7-5.5 years), 17 patients in the AVF ligation group were studied with repeat CMR with a median duration to follow-up imaging of 5.1 years (IQR, 4.7-5.5 years). Statistically significant further reductions in LVM (-17.6±23.0 g, P=0.006) and LVM index (-10.0±13.0 g/m2, P=0.006) were documented. Conclusions: The benefit of AVF ligation on LVM and LVM index regression appears to persist long term. This has the potential to lead to a significant reduction in cardiovascular mortality.


Asunto(s)
Fístula Arteriovenosa , Trasplante de Riñón , Fístula Arteriovenosa/diagnóstico por imagen , Estudios de Cohortes , Estudios de Seguimiento , Humanos , Receptores de Trasplantes
4.
Am J Physiol Heart Circ Physiol ; 317(4): H811-H819, 2019 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-31441693

RESUMEN

A large body of evidence demonstrates an independent association between arterial stiffness and prospective risk of cardiovascular events. A reduction in coronary perfusion is presumed to underscore this association; however, studies confirming this are lacking. This study compared invasive measures of coronary blood flow (CBF) with cardiac magnetic resonance (CMR)-derived aortic distensibility (AD). Following coronary angiography, a Doppler FloWire and infusion microcatheter were advanced into the study vessel. Average peak velocity (APV) was acquired at baseline and following intracoronary adenosine to derive coronary flow velocity reserve (CFVR = hyperemic APV/resting APV) and CBF [π × (diameter)2 × APV × 0.125]. Following angiography, patients underwent CMR to evaluate distensibility at the ascending aorta (AA), proximal descending aorta (PDA) and distal descending aorta (DDA). Fifteen participants (53 ± 13 yr) with minor epicardial disease (maximum stenosis <30%) were enrolled. Resting CBF was 44.1 ± 11.9 mL/min, hyperemic CBF was 143.8 ± 37.4 mL/min, and CFVR was 3.15 ± 0.48. AD was 3.89 ± 1.72·10-3mmHg-1 at the AA, 4.08 ± 1.80·10-3mmHg-1 at the PDA, and 4.42 ± 1.67·10-3mmHg-1 at the DDA. All levels of distensibility correlated with resting CBF (R2 = 0.350-0.373, P < 0.05), hyperemic CBF (R2 = 0.453-0.464, P < 0.01), and CFVR (R2 = 0.442-0.511, P < 0.01). This study demonstrates that hyperemic and, to a lesser extent resting CBF, are significantly associated with measures of aortic stiffness in patients with only minor angiographic disease. These findings provide further in vivo support for the observed prognostic capacity of large artery function in cardiovascular event prediction.NEW & NOTEWORTHY Cardiac magnetic resonance-derived aortic distensibility is associated with invasive measures of coronary blood flow. Large artery function is more strongly correlated with hyperemic than resting blood flow. Increased stiffness may represent a potential target for novel antianginal medications.


Asunto(s)
Aorta/fisiopatología , Circulación Coronaria , Estenosis Coronaria/fisiopatología , Vasos Coronarios/fisiopatología , Hiperemia/fisiopatología , Rigidez Vascular , Adenosina/administración & dosificación , Adulto , Anciano , Aorta/diagnóstico por imagen , Velocidad del Flujo Sanguíneo , Angiografía Coronaria , Estenosis Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Ecocardiografía Doppler , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Vasodilatadores/administración & dosificación
5.
Circulation ; 139(25): 2809-2818, 2019 06 18.
Artículo en Inglés | MEDLINE | ID: mdl-31045455

RESUMEN

BACKGROUND: Cardiovascular morbidity and mortality remain high in recipients of a kidney transplant. The persistence of a patent arteriovenous fistula (AVF) after transplantation may contribute to ongoing maladaptive cardiovascular remodeling. The ability to reverse this maladaptive remodeling by ligation of this AVF is unknown. We conducted the first randomized controlled trial to evaluate the effect of AVF ligation on cardiac structure and function in stable kidney transplant recipients. METHODS: In this randomized controlled trial, kidney transplant recipients (>12 months after transplantation with stable graft function) were randomized to AVF ligation or no intervention. All participants underwent cardiac magnetic resonance imaging at baseline and at 6 months. The primary outcome was the change in left ventricular (LV) mass. Secondary outcomes included changes in LV volumes, left and right atrial areas, LV ejection fraction, NT-proBNP (N-terminal pro-B-type natriuretic peptide) levels, cardiac output/index, brachial flows (ipsilateral to AVF), and pulmonary artery velocity. RESULTS: A total of 93 patients were screened, of whom 64 met the inclusion criteria and were randomized to the AVF ligation (n=33) or control (n=31) group. Fifty-four participants completed the study: 27 in the AVF ligation group and 27 in the control group. On the second cardiac magnetic resonance scan, a mean decrease of 22.1 g (95% CI, 15.0-29.1) was observed in LV mass in the AVF ligation group compared with a small increase of 1.2 g (95% CI, -4.8 to 7.2) in the control group ( P<0.001). Significant decreases in LV end-diastolic volumes, LV end-systolic volumes, cardiac output, cardiac index, atrial volumes, and NT-proBNP were also seen in the AVF closure group ( P<0.01). No significant changes were observed in LV ejection fraction ( P=0.93) and pulmonary artery velocity ( P=0.07). No significant complications were noted after AVF ligation. No changes in estimated glomerular filtration rate or systolic and diastolic blood pressures were observed between cardiac magnetic resonance scans. CONCLUSIONS: Elective ligation of patent AVF in adults with stable kidney transplant function resulted in clinically significant reduction of LV myocardial mass. CLINICAL TRIAL REGISTRATION: Australian and New Zealand Clinical Trials Registry URL: https://www.anzctr.org.au . Unique Identifier: ACTRN12613001302741.


Asunto(s)
Derivación Arteriovenosa Quirúrgica , Hipertrofia Ventricular Izquierda/fisiopatología , Fallo Renal Crónico/cirugía , Trasplante de Riñón , Diálisis Renal , Función Ventricular Izquierda , Remodelación Ventricular , Anciano , Derivación Arteriovenosa Quirúrgica/efectos adversos , Biomarcadores/sangre , Femenino , Tasa de Filtración Glomerular , Hemodinámica , Humanos , Hipertrofia Ventricular Izquierda/diagnóstico por imagen , Hipertrofia Ventricular Izquierda/etiología , Fallo Renal Crónico/complicaciones , Fallo Renal Crónico/diagnóstico , Fallo Renal Crónico/fisiopatología , Trasplante de Riñón/efectos adversos , Ligadura , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Péptido Natriurético Encefálico/sangre , Fragmentos de Péptidos/sangre , Estudios Prospectivos , Recuperación de la Función , Diálisis Renal/efectos adversos , Australia del Sur , Volumen Sistólico , Factores de Tiempo , Resultado del Tratamiento
6.
Atherosclerosis ; 272: 207-215, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29627741

RESUMEN

BACKGROUND AND AIMS: Echocardiographic studies have shown improvements in cardiac indices associated with renal sympathetic denervation (RDN), however, the benefits on myocardial perfusion have never been assessed. This trial was designed to study the effects of RDN on myocardial perfusion using cardiac magnetic resonance (CMR) imaging. METHODS: A total of 14 patients with resistant hypertension were recruited for RDN and myocardial perfusion, alongside other CMR indices, was assessed at baseline and at 6 months. RESULTS: RDN showed significant reduction of mean office blood pressures from 181/100 ±â€¯19/16 mmHg to 147/85 ±â€¯19/17 mmHg, 6 months after the procedure (p < 0.0001). This was combined with significant improvement in regional aortic distensibility (p < 0.02) and associated with trends of improved myocardial perfusion reserve index (baseline = 2.2 ±â€¯1; 6 months = 2.9 ±â€¯1 units) (p = 0.08). Left ventricular end systolic volume index decreased from baseline to 6 months post procedure, 27 ±â€¯13 ml/m2vs. 22 ±â€¯10 ml/m2 (p = 0.03), but there was no significant change in left ventricular end diastolic volume index (p = 0.09). There was significant improvement in mean left ventricular ejection fraction from 68 ± 10% to 72 + 9%, 6 months post procedure (p = 0.04). T1 mapping failed to detect fibrosis in these patients at baseline and therefore no change was noted, however, extracellular volume percent improved from 46 ±â€¯4% at baseline to 41 ±â€¯8% at 6 months (p = 0.002). CONCLUSIONS: This study demonstrates that renal sympathetic denervation increased myocardial perfusion by 32% as assessed by CMR, and, this was associated with improvements in cardiac volumes and function. Larger well controlled and randomized studies are required to assess the clinical significance of these findings.


Asunto(s)
Corazón/diagnóstico por imagen , Corazón/fisiología , Riñón/inervación , Miocardio/patología , Simpatectomía , Aorta/patología , Presión Sanguínea , Ecocardiografía , Humanos , Hipertensión/fisiopatología , Riñón/fisiopatología , Imagen por Resonancia Magnética , Perfusión , Estudios Prospectivos , Función Ventricular Izquierda
7.
J Int Med Res ; 45(6): 1680-1692, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29239257

RESUMEN

Chest pain is an important presenting symptom. However, few cases of chest pain are diagnosed as acute coronary syndrome (ACS) in the acute setting. This results in frequent inappropriate discharge and major delay in treatment for patients with underlying ACS. The conventional methods of assessing ACS, which include electrocardiography and serological markers of infarct, can take time to manifest. Recent studies have investigated more sensitive and specific imaging modalities that can be used. Diastolic dysfunction occurs early following coronary artery occlusion and its detection is useful in confirming the diagnosis, risk stratification, and prognosis post-ACS. Cardiac magnetic resonance provides a single imaging modality for comprehensive evaluation of chest pain in the acute setting. In particular, cardiac magnetic resonance has many imaging techniques that assess diastolic dysfunction post-coronary artery occlusion. Techniques such as measurement of left atrial size, mitral inflow, and mitral annular and pulmonary vein flow velocities with phase-contrast imaging enable general assessment of ventricular diastolic function. More novel imaging techniques, such as T2-weighted imaging for oedema, T1 mapping, and myocardial tagging, allow early determination of regional diastolic dysfunction and oedema. These findings may correspond to specific infarcted arteries that may be used to tailor eventual percutaneous coronary artery intervention.


Asunto(s)
Síndrome Coronario Agudo/diagnóstico , Síndrome Coronario Agudo/fisiopatología , Diástole , Imagen por Resonancia Magnética , Miocardio/patología , Ensayos Clínicos como Asunto , Humanos , Flujo Sanguíneo Regional
8.
Int J Nephrol Renovasc Dis ; 10: 243-249, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28919800

RESUMEN

AIM: Preclinical studies have demonstrated improvements in renal blood flow after renal sympathetic denervation (RSDN); however, such effects are yet to be confirmed in patients with resistant hypertension. Herein, we assessed the effects of RSDN on renal artery blood flow and diameter at multiple time points post-RSDN. METHODS AND RESULTS: Patients (n=11) with systolic blood pressures ≥160 mmHg despite taking three or more antihypertensive medications at maximum tolerated dose were recruited into this single-center, prospective, non-blinded study. Magnetic resonance imaging indices included renal blood flow and renal artery diameters at baseline, 1 month and 6 months. In addition to significant decreases in blood pressures (p<0.0001), total volume of blood flow per cardiac cycle increased by 20% from 6.9±2 mL at baseline to 8.4±2 mL (p=0.003) at 1 month and to 8.0±2 mL (p=0.04) 6 months post-procedure, with no changes in the renal blood flow. There was a significant decrease in renal artery diameters from 7±2 mm at baseline to 6±1 mm (p=0.03) at 1 month post-procedure. This decrease was associated with increases in maximum velocity of blood flow from 73±20 cm/s at baseline to 78±19 cm/s at 1 month post-procedure. Notably, both parameters reverted to 7±2 mm and 72±18 cm/s, respectively, 6 months after procedure. CONCLUSION: RSDN improves renal physiology as evidenced by significant improvements in total volume of blood flow per cardiac cycle. Additionally, for the first time, we identified a transient decrease in renal artery diameters immediately after procedure potentially caused by edema and inflammation that reverted to baseline values 6 months post-procedure.

10.
Eur Heart J Cardiovasc Imaging ; 18(12): 1361-1368, 2017 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-28013284

RESUMEN

AIMS: We evaluated the utility of computerized tomography (CT) with respect to sizing work-up for percutaneous left atrial appendage (LAA) closure, and implications for procedural safety and outcomes. METHODS AND RESULTS: Contrast-enhanced multi-detector CT was routinely conducted to guide sizing for LAA closure in addition to transoesophageal echocardiography (TOE). Procedural safety and efficacy were prospectively assessed. Across 73 consecutive cases there were no device-related procedural complications, and no severe leaks. Systematic bias in orifice sizing by TOE vs. CT was significant on retrospective analysis (bias -3.0 mm vs. maximum diameter on CT; bias -1.1 mm vs. mean diameter on CT). Importantly, this translated to an altered device size selection in more than half of all cases, and median size predicted by CT was one interval greater than that predicted by TOE (27 mm vs. 24 mm). Of particular note, gross sizing error by TOE vs. CT was observed in at least 3.4% of cases. Degree of discrepancy between TOE and CT was correlated with LAA orifice eccentricity, orifice size, and left atrial volume. Mean orifice size by CT had the greatest utility for final Watchman device-size selection. CONCLUSIONS: In this single-centre registry of LAA closure, routine incorporation of CT was associated with excellent outcomes for procedural safety and absence of major residual leak. Mean orifice size may be preferable to maximum orifice size. A particular value of CT may be the detection and subsequent avoidance of gross sizing error by 2D TOE that occurs in a small but important proportion of cases.


Asunto(s)
Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Ecocardiografía Transesofágica/métodos , Procedimientos Endovasculares/métodos , Tomografía Computarizada Multidetector/métodos , Seguridad del Paciente , Anciano , Apéndice Atrial/fisiopatología , Cateterismo Cardíaco/métodos , Estudios de Cohortes , Procedimientos Endovasculares/instrumentación , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Imagen Multimodal/métodos , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo , Dispositivo Oclusor Septal , Índice de Severidad de la Enfermedad , Estadísticas no Paramétricas , Resultado del Tratamiento
11.
Aust Fam Physician ; 45(10): 761-764, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27695729

RESUMEN

BACKGROUND: Imaging of the heart is important in the diagnosis and follow-up of a broad range of cardiac pathology. The authors discuss the growing role of cardiac magnetic resonance imaging (CMR) in cardiology practice and its relevance to primary healthcare. OBJECTIVE: In this article we discuss the advantages of CMR over other imaging modalities, and give a brief description of the common CMR techniques and cardiac pathologies where CMR is especially useful. DISCUSSION: CMR provides specific advantages over other cardiac imaging modalities when evaluating pathology in congenital heart disease, cardiac masses, cardiomyopathies, and in some aspects of ischaemic and valvular heart diseases. The strength of CMR in these pathologies includes its precise ana-tomical delineation of structures, characterisation of myocardial tissue, and accurate, reproducible measurements of blood volume and flow. CMR is used in inpatient and outpatient settings, and is available primarily in major hospitals.


Asunto(s)
Técnicas de Imagen Cardíaca/métodos , Enfermedades Cardiovasculares/diagnóstico por imagen , Enfermedades Cardiovasculares/diagnóstico , Técnicas de Diagnóstico Cardiovascular/instrumentación , Imagen por Resonancia Magnética/métodos , Enfermedades de la Aorta/diagnóstico , Enfermedades de la Aorta/diagnóstico por imagen , Técnicas de Imagen Cardíaca/instrumentación , Cardiología/métodos , Cardiología/tendencias , Cardiomiopatías/diagnóstico , Cardiomiopatías/diagnóstico por imagen , Técnicas de Diagnóstico Cardiovascular/tendencias , Cardiopatías Congénitas/diagnóstico , Cardiopatías Congénitas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/diagnóstico , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Humanos , Hipertensión Pulmonar/diagnóstico , Hipertensión Pulmonar/diagnóstico por imagen , Aumento de la Imagen/métodos , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/diagnóstico por imagen , Miocarditis/diagnóstico , Miocarditis/diagnóstico por imagen , Pericarditis/diagnóstico , Pericarditis/diagnóstico por imagen
12.
Heart Lung Circ ; 25(11): 1094-1106, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27210302

RESUMEN

BACKGROUND: Cardiovascular magnetic resonance (CMR) advances in imaging techniques, permits the ability to accurately characterise tissue injury post myocardial infarction. Pre-contrast T1 mapping enables this through measurement of pre-contrast T1 relaxation times. We investigate the relationship between T1 characterisation of myocardial injury with global and regional diastolic function. METHODS: Revascularised acute myocardial infarction patients with normal left ventricular (LV) systolic function on TTE were assessed by 1.5T CMR. Acute regional diastolic wall motion abnormalities, global diastolic function measurements, acute segmental damage fraction with LGE and mean segmental pre-contrast T1 values were assessed on matching short axis slices. RESULTS: Forty-four patients were analysed. Mean LVEF was 62.1±9.4%. No difference between NSTEMI (22/44) and STEMI in mean pre-contrast T1 values of infarcted (1025.0±109.2 vs 1011.0±81.6ms, p=0.70), adjacent (948.3±45.3 vs 941.1±46.6ms, p=0.70) and remote (888.8±52.8 vs 881.2±54.5ms, p=0.66) segments was detected. There was no correlation between pre-contrast T1 of infarcted segments with global diastolic dysfunction (E/A, r2=0.216, p=0.06; S/D, r2=0.243, p=0.053; E/E', r2=0.240, p=0.072), but there was significantly positive, moderate correlation with circumferential diastolic strain rate, (r2=0.579, p<0.01) with excellent agreement and reproducibility. CONCLUSION: Cardiac magnetic resonance evaluation of pre-contrast T1 values revealed no difference between NSTEMI and STEMI patients in terms of tissue characterisation post-myocardial infarction. However, pre-contrast T1 of infarcted tissue is significantly correlated with regional diastolic circumferential strain rate.


Asunto(s)
Diástole , Imagen por Resonancia Magnética , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/fisiopatología , Miocardio , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/fisiopatología , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/complicaciones , Infarto del Miocardio/terapia , Disfunción Ventricular Izquierda/etiología
14.
JACC Clin Electrophysiol ; 1(6): 478-485, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29759401

RESUMEN

OBJECTIVES: Predictors of residual leak following percutaneous LAA closure were evaluated. BACKGROUND: Left atrial appendage (LAA) closure aims to exclude this structure from the circulation, typically using a circular occluder. A noncircular orifice is frequently encountered however, and fibrous remodeling of the LAA in atrial fibrillation may restrict orifice deformation. Noncircularity may thus be implicated in the occurrence of residual leak despite an appropriately oversized device. METHODS: Pre-procedural multislice computerized tomography was used to quantify LAA orifice eccentricity and irregularity. Univariate predictors of residual leak were identified with respect to the orifice, device, and relevant clinical variables, with the nature of any correlations then further evaluated. RESULTS: Eccentricity and irregularity indexes of the orifice in 31 individuals were correlated with residual leak even where the device was appropriately oversized. An eccentricity index of 0.15 predicted a residual leak with 85% sensitivity and 59% specificity. An irregularity index of 0.05 predicted a significant residual leak ≥3 mm with 100% sensitivity and 86% specificity. Orifice size, device size, degree of device oversize, left atrial volume, and pulmonary artery pressure were not predictors of residual leak. CONCLUSIONS: Eccentricity and irregularity of the LAA orifice are implicated in residual leak after percutaneous closure even where there is appropriate device over-size. Irregularity index in particular is a novel predictor of residual leak, supporting a closer consideration of orifice morphology before closure.

15.
World J Cardiol ; 6(6): 405-14, 2014 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-24976912

RESUMEN

Cardiovascular disease (CVD) is the leading cause of death in the western world and is becoming more important in the developing world. Recently, advances in monitoring, revascularisation and pharmacotherapy have resulted in a reduction in mortality. However, although mortality rates have declined, the burden of disease remains large resulting in high direct and indirect healthcare costs related to CVDs. In Australia, acute coronary syndrome (ACS) accounts for more than 300000 years of life lost due to premature death and a total cost exceeding eight billion dollars annually. It is also the main contributor towards the discrepancy in life expectancy between indigenous and non-indigenous Australians. The high prevalence of CVD along with its associated cost urgently requires a reliable but non-invasive and cost-effective imaging modality. The imaging modality of choice should be able to accelerate the diagnosis of ACS, aid in the risk stratification of de novo coronary artery disease and avail incremental information of prognostic value such as viability which cardiovascular magnetic resonance (CMR) allows. Despite its manifold benefits, there are limitations to its wider use in routine clinical assessment and more studies are required into assessing its cost-effectiveness. It is hoped that with greater development in the technology and imaging protocols, CMR could be made less cumbersome, its imaging protocols less lengthy, the technology more inexpensive and easily applied in routine clinical practice.

17.
Int J Cardiol ; 165(1): 61-6, 2013 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-21875755

RESUMEN

INTRODUCTION: Microvascular obstruction (MVO) following ST-segment elevation myocardial infarction (STEMI) is associated with larger infarct size and an increased mortality. Although angiographic predictors of MVO in primary percutaneous coronary intervention (primary-PCI) setting have been identified, an earlier and objective "in-lab" predictor may be beneficial, in order to potentially influence therapies administered during primary-PCI. We hypothesised that intracoronary-electrocardiogram (IC-ECG) is a simple, objective and accurate predictor of MVO evaluated by cardiac magnetic resonance (CMR) and is comparable to myocardial blush grade (MBG) and TIMI myocardial perfusion grade (TMPG). METHOD: Intracoronary ECG was performed during primary-PCI. Intracoronary ST-segment measurement was performed before and immediately after opening of infarct-related-artery. Intracoronary ST-segment resolution (IC-STR) was defined as ≥ 1 mm improvement compared to baseline. Contrast enhanced CMR was performed at 4 and 90 days post primary-PCI. Primary endpoint was MVO on late gadolinium hyperenhancement assessed by CMR at day 4. RESULTS: Sixty-four consecutive patients (age 59 ± 11 years; 55 males) were recruited. Intracoronary ST-segment resolution correlated with MVO (p=0.005). Furthermore, IC-STR correlated with infarct-mass, non-viable-mass, peak creatinine kinase and end-systolic-volume at day 4. Intracoronary ST-segment resolution also correlated with favourable left ventricular end-diastolic-volume at day 90 (p=0.022). On multivariate analysis, IC-STR was an independent predictor of MVO. CONCLUSION: Intracoronary ST-segment resolution is a strong in-lab predictor of MVO assessed 4 days after STEMI on CMR. Furthermore, IC-STR correlates with infarct size and left ventricular remodelling at 3 months. Further studies are required to understand potential clinical utility of this tool.


Asunto(s)
Vasos Coronarios/patología , Electrocardiografía/métodos , Microcirculación/fisiología , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/cirugía , Intervención Coronaria Percutánea/métodos , Anciano , Estudios de Cohortes , Vasos Coronarios/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/fisiopatología , Valor Predictivo de las Pruebas , Estudios Prospectivos , Resultado del Tratamiento
20.
Int J Cardiol ; 167(5): 2055-60, 2013 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-22664364

RESUMEN

BACKGROUND: The high diagnostic accuracy of adenosine stress cardiac magnetic resonance (AS-CMR) for detecting coronary artery stenoses, with high sensitivity and specificity, is well documented. Prognostic data, particularly in non-low risk study populations and for greater than 12 months of follow up, is however lacking or variable in its findings. We present prognostic data, in an intermediate cardiovascular risk cohort undergoing adenosine stress perfusion CMR, over approximately 2 years of follow up. METHODS: The study population comprised 362 patients referred for a clinically indicated stress CMR and included patients with proven coronary artery disease (CAD; n=157) or unknown CAD status, yet an intermediate cardiovascular risk profile (n=205). Perfusion imaging was performed at stress (adenosine 140 µg/kg/min) and rest on a 1.5 T system. Patient records and state-wide hospital databases were reviewed. Major adverse cardiac events--death, myocardial infarction, revascularisation or ischaemic hospitalisation--were evaluated over a median follow up of 22 months. RESULTS: Of the 362 cases, 90 had a stress perfusion CMR positive for ischaemia and experienced a MACE rate of 24%. Of the 272 negative CMR scans, 225 were also negative for late gadolinium enhancement, and in this group MACE was encountered in only 6 (2.7%) patients. Accordingly a negative stress CMR afforded a freedom from MACE of 97.3%. Freedom from death/myocardial infarction was 99.6%. CONCLUSIONS: In patients with confirmed coronary artery disease or at intermediate risk for cardiovascular events, a negative stress perfusion CMR is associated with an excellent prognosis over nearly 2 years of follow up.


Asunto(s)
Adenosina , Enfermedades Cardiovasculares/diagnóstico , Enfermedades Cardiovasculares/fisiopatología , Prueba de Esfuerzo/métodos , Gadolinio , Imagen por Resonancia Cinemagnética/métodos , Anciano , Estudios de Cohortes , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA