Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Breast Cancer Res ; 13(5): R108, 2011 Nov 03.
Artículo en Inglés | MEDLINE | ID: mdl-22035507

RESUMEN

INTRODUCTION: Breast cancer detection using mammography has improved clinical outcomes for many women, because mammography can detect very small (5 mm) tumors early in the course of the disease. However, mammography fails to detect 10 - 25% of tumors, and the results do not distinguish benign and malignant tumors. Reducing the false positive rate, even by a modest 10%, while improving the sensitivity, will lead to improved screening, and is a desirable and attainable goal. The emerging application of magnetic relaxometry, in particular using superconducting quantum interference device (SQUID) sensors, is fast and potentially more specific than mammography because it is designed to detect tumor-targeted iron oxide magnetic nanoparticles. Furthermore, magnetic relaxometry is theoretically more specific than MRI detection, because only target-bound nanoparticles are detected. Our group is developing antibody-conjugated magnetic nanoparticles targeted to breast cancer cells that can be detected using magnetic relaxometry. METHODS: To accomplish this, we identified a series of breast cancer cell lines expressing varying levels of the plasma membrane-expressed human epidermal growth factor-like receptor 2 (Her2) by flow cytometry. Anti-Her2 antibody was then conjugated to superparamagnetic iron oxide nanoparticles using the carbodiimide method. Labeled nanoparticles were incubated with breast cancer cell lines and visualized by confocal microscopy, Prussian blue histochemistry, and magnetic relaxometry. RESULTS: We demonstrated a time- and antigen concentration-dependent increase in the number of antibody-conjugated nanoparticles bound to cells. Next, anti Her2-conjugated nanoparticles injected into highly Her2-expressing tumor xenograft explants yielded a significantly higher SQUID relaxometry signal relative to unconjugated nanoparticles. Finally, labeled cells introduced into breast phantoms were measured by magnetic relaxometry, and as few as 1 million labeled cells were detected at a distance of 4.5 cm using our early prototype system. CONCLUSIONS: These results suggest that the antibody-conjugated magnetic nanoparticles are promising reagents to apply to in vivo breast tumor cell detection, and that SQUID-detected magnetic relaxometry is a viable, rapid, and highly sensitive method for in vitro nanoparticle development and eventual in vivo tumor detection.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Espectroscopía de Resonancia Magnética/métodos , Nanopartículas de Magnetita , Animales , Neoplasias de la Mama/metabolismo , Línea Celular Tumoral , Membrana Celular/inmunología , Membrana Celular/metabolismo , Femenino , Compuestos Férricos , Humanos , Inmunoconjugados , Ratones , Ratones Desnudos , Fantasmas de Imagen , Receptor ErbB-2/inmunología , Receptor ErbB-2/metabolismo , Sensibilidad y Especificidad , Ensayos Antitumor por Modelo de Xenoinjerto
2.
J Magn Magn Mater ; 323(6): 767-774, 2011 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-21516188

RESUMEN

We use dynamic susceptometry measurements to extract semiempirical temperature-dependent, 255 to 400 K, magnetic parameters that determine the behavior of single-core nanoparticles useful for SQUID relaxometry in biomedical applications. Volume susceptibility measurements were made in 5K degree steps at nine frequencies in the 0.1 - 1000 Hz range, with a 0.2 mT amplitude probe field. The saturation magnetization (M(s)) and anisotropy energy density (K) derived from the fitting of theoretical susceptibility to the measurements both increase with decreasing temperature; good agreement between the parameter values derived separately from the real and imaginary components is obtained. Characterization of the Néel relaxation time indicates that the conventional prefactor, 0.1 ns, is an upper limit, strongly correlated with the anisotropy energy density. This prefactor decreases substantially for lower temperatures, as K increases. We find, using the values of the parameters determined from the real part of the susceptibility measurements at 300 K, that SQUID relaxometry measurements of relaxation and excitation curves on the same sample are well described.

3.
Phys Med Biol ; 55(19): 5985-6003, 2010 Oct 07.
Artículo en Inglés | MEDLINE | ID: mdl-20858918

RESUMEN

Optimizing the sensitivity of SQUID (superconducting quantum interference device) relaxometry for detecting cell-targeted magnetic nanoparticles for in vivo diagnostics requires nanoparticles with a narrow particle size distribution to ensure that the Néel relaxation times fall within the measurement timescale (50 ms-2 s, in this work). To determine the optimum particle size, single-core magnetite nanoparticles (with nominal average diameters 20, 25, 30 and 35 nm) were characterized by SQUID relaxometry, transmission electron microscopy, SQUID susceptometry, dynamic light scattering and zeta potential analysis. The SQUID relaxometry signal (detected magnetic moment/kg) from both the 25 nm and 30 nm particles was an improvement over previously studied multi-core particles. However, the detected moments were an order of magnitude lower than predicted based on a simple model that takes into account the measured size distributions (but neglects dipolar interactions and polydispersity of the anisotropy energy density), indicating that improved control of several different nanoparticle properties (size, shape and coating thickness) will be required to achieve the highest detection sensitivity. Antibody conjugation and cell incubation experiments show that single-core particles enable a higher detected moment per cell, but also demonstrate the need for improved surface treatments to mitigate aggregation and improve specificity.


Asunto(s)
Conductividad Eléctrica , Magnetismo , Nanopartículas de Magnetita/química , Imagen Molecular/métodos , Anticuerpos/química , Anticuerpos/metabolismo , Humanos , Células Jurkat , Microscopía Electrónica de Transmisión , Nanoconjugados/química , Tamaño de la Partícula
4.
Cancer Res ; 69(21): 8310-6, 2009 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-19808954

RESUMEN

Acute leukemia is a hematopoietic malignancy for which the accurate measurement of minimal residual disease is critical to determining prognosis and treatment. Although bone marrow aspiration and light microscopy remain the current standard of care for detecting residual disease, these approaches cannot reliably discriminate less than 5% lymphoblast cells. To improve the detection of leukemia cells in the marrow, we developed a novel apparatus that utilizes antibodies conjugated to superparamagnetic iron oxide nanoparticles (SPION) and directed against the acute leukemia antigen CD34, coupled with a "magnetic needle" biopsy. Leukemia cell lines expressing high or minimal CD34 were incubated with anti-CD34-conjugated SPIONs. Three separate approaches including microscopy, superconducting quantum interference device magnetometry, and in vitro magnetic needle extraction were then used to assess cell sampling. We found that CD34-conjugated nanoparticles preferentially bind high CD34-expressing cell lines. Furthermore, the magnetic needle enabled identification of both cell line and patient leukemia cells diluted into normal blood at concentrations below those normally found in remission marrow samples. Finally, the magnetic needle enhanced the percentage of lymphoblasts detectable by light microscopy by 10-fold in samples of fresh bone marrow aspirate approximating minimal residual disease. These data suggest that bone marrow biopsy using antigen-targeted magnetic nanoparticles and a magnetic needle for the evaluation of minimal residual disease in CD34-positive acute leukemias can significantly enhance sensitivity compared with the current standard of care.


Asunto(s)
Antígenos CD34/análisis , Células de la Médula Ósea/patología , Leucemia/diagnóstico , Magnetismo , Nanopartículas del Metal , Neoplasia Residual/diagnóstico , Compuestos Férricos/química , Humanos , Sensibilidad y Especificidad , Células Tumorales Cultivadas
5.
J Magn Magn Mater ; 321(10): 1459-1464, 2009 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-20161153

RESUMEN

Magnetite nanoparticles (Chemicell SiMAG-TCL) were characterized by SQUID-relaxometry, susceptometry, and TEM. The magnetization detected by SQUID-relaxometry was 0.33% of that detected by susceptometry, indicating that the sensitivity of SQUID-relaxometry could be significantly increased through improved control of nanoparticle size. The relaxometry data were analyzed by the moment superposition model (MSM) to determine the distribution of nanoparticle moments. Analysis of the binding of CD34-conjugated nanoparticles to U937 leukemia cells revealed 60,000 nanoparticles per cell, which were collected from whole blood using a prototype magnetic biopsy needle, with a capture efficiency of >65% from a 750 µl sample volume in 1 minute.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA