Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Synchrotron Radiat ; 28(Pt 6): 1935-1947, 2021 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-34738949

RESUMEN

NanoMAX is the first hard X-ray nanoprobe beamline at the MAX IV laboratory. It utilizes the unique properties of the world's first operational multi-bend achromat storage ring to provide an intense and coherent focused beam for experiments with several methods. In this paper we present the beamline optics design in detail, show the performance figures, and give an overview of the surrounding infrastructure and the operational diffraction endstation.

2.
J Synchrotron Radiat ; 28(Pt 4): 1253-1260, 2021 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-34212891

RESUMEN

The emergence of fourth-generation synchrotrons is prompting the development of new systems for experimental control and data acquisition. However, as general control systems are designed to cover a wide set of instruments and techniques, they tend to become large and complicated, at the cost of experimental flexibility. Here we present Contrast, a simple Python framework for interacting with beamline components, orchestrating experiments and managing data acquisition. The system is presented and demonstrated via its application at the NanoMAX beamline of the MAX IV Laboratory.

3.
J Appl Crystallogr ; 53(Pt 6): 1444-1451, 2020 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-33304222

RESUMEN

Ptychographic X-ray computed tomography is a quantitative three-dimensional imaging technique offered to users of multiple synchrotron radiation sources. Its dependence on the coherent fraction of the available X-ray beam makes it perfectly suited to diffraction-limited storage rings. Although MAX IV is the first, and so far only, operating fourth-generation synchrotron light source, none of its experimental stations is currently set up to offer this technique to its users. The first ptychographic X-ray computed tomography experiment has therefore been performed on the NanoMAX beamline. From the results, information was gained about the current limitations of the experimental setup and where attention should be focused for improvement. The extracted parameters in terms of scanning speed, size of the imaged volume and achieved resolutions should provide a baseline for future users designing nano-tomography experiments on the NanoMAX beamline.