Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Europace ; 25(4): 1441-1450, 2023 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-36794441

RESUMEN

AIMS: Patients who undergo permanent pacemaker (PPM) implantation after transcatheter aortic valve replacement (TAVR) have a worse outcome. The aim of this study was to identify risk factors of worse outcomes in patients with post-TAVR PPM implantation. METHODS AND RESULTS: This is a single-centre, retrospective study of consecutive patients who underwent post-TAVR PPM implantation from 11 March 2011 to 9 November 2019. Clinical outcomes were evaluated by landmark analysis with cut-off at 1 year after the PPM implantation. Of the 1389 patients underwent TAVR during the study duration and a total of 110 patients were included in the final analysis. Right ventricular pacing burden (RVPB) ≥ 30% at 1 year was associated with a higher likelihood of heart failure (HF) readmission [adjusted hazard ratio (aHR): 6.333; 95% confidence interval [CI]: 1.417-28.311; P = 0.016] and composite endpoint of overall death and/or HF (aHR: 2.453; 95% CI: 1.040-5.786; P = 0.040). The RVPB ≥30% at 1 year was associated with higher atrial fibrillation burden (24.1 ± 40.6% vs. 1.2 ± 5.3%; P = 0.013) and a decrease in left ventricular ejection fraction (-5.0 ± 9.8% vs. + 1.1 ± 7.9%; P = 0.005). The predicting factors of the RVPB ≥30% at 1 year were the presence of RVPB ≥40% at 1 month and the valve implantation depth measured from non-coronary cusp ≥4.0 mm (aHR: 57.808; 95% CI: 12.489-267.584; P < 0.001 and aHR: 6.817; 95% CI: 1.829-25.402; P = 0.004). CONCLUSIONS: The RVPB ≥30% at 1 year was associated with worse outcomes. Clinical benefit of minimal RV pacing algorithms and biventricular pacing needs to be investigated.


Asunto(s)
Estenosis de la Válvula Aórtica , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estimulación Cardíaca Artificial/efectos adversos , Estudios Retrospectivos , Volumen Sistólico , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/cirugía , Función Ventricular Izquierda , Factores de Riesgo , Válvula Aórtica/cirugía
2.
Am. j. cardiol ; 15(175): 80-87, July. 2022.
Artículo en Inglés | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1377949

RESUMEN

ABSTRACT Previous studies reported that new-onset persistent left bundle branch block (NOP-LBBB) was related to worse outcomes after transcatheter aortic valve implantation (TAVI). However, these results can be confounded by the presence of permanent pacemaker (PPM) implantation before and after TAVI. Long-term outcomes and the risk stratification of NOP-LBBB not having PPM implantation before and after TAVI have not been fully investigated. This is an international, multicenter, retrospective study of patients who underwent TAVI from July 31, 2007, to May 8, 2020. A total of 2,240 patients were included, and 17.5% of patients developed NOP-LBBB. NOP-LBBB was associated with cardiac mortality (adjusted hazard ratio [aHR] 1.419, 95% confidence interval [CI] 1.014 to 1.985, p = 0.041) and the composite outcomes of cardiac mortality and/or heart failure readmission (aHR 1.313, 95% CI 1.027 to 1.678, p = 0.030). Patients who developed NOP-LBBB with pre-TAVI left ventricular ejection fraction (LVEF) <40% were significantly associated with cardiac mortality (aHR 2.049, 95% CI 1.039 to 4.041, p = 0.038), heart failure (aHR 3.990, 95% CI 2.362 to 6.741, p <0.001), and the composite outcome (aHR 2.729, 95% CI 1.703 to 4.374, p <0.001). Although NOP-LBBB with pre-TAVI LVEF >40% had a significant decrease in LVEF 6 to 12 months after TAVI (-1.8 ± 9.7% vs +0.6 ± 8.1%, p = 0.003), NOP-LBBB with pre-TAVI LVEF <40% had a significant increase in LVEF 6 to 12 months after TAVI (+9.7 ± 13.6% vs +13.0 ± 11.7%, p = 0.157). In conclusion, patients with NOP-LBBB without pre-TAVI and post-TAVI PPM developed significantly worse long-term outcomes, especially in patients with pre-TAVI LVEF <40%. Further prospective investigation should be undertaken.


Asunto(s)
Bloqueo de Rama , Reemplazo de la Válvula Aórtica Transcatéter , Insuficiencia Cardíaca
3.
Am J Cardiol ; 175: 80-87, 2022 07 15.
Artículo en Inglés | MEDLINE | ID: mdl-35597627

RESUMEN

Previous studies reported that new-onset persistent left bundle branch block (NOP-LBBB) was related to worse outcomes after transcatheter aortic valve implantation (TAVI). However, these results can be confounded by the presence of permanent pacemaker (PPM) implantation before and after TAVI. Long-term outcomes and the risk stratification of NOP-LBBB not having PPM implantation before and after TAVI have not been fully investigated. This is an international, multicenter, retrospective study of patients who underwent TAVI from July 31, 2007, to May 8, 2020. A total of 2,240 patients were included, and 17.5% of patients developed NOP-LBBB. NOP-LBBB was associated with cardiac mortality (adjusted hazard ratio [aHR] 1.419, 95% confidence interval [CI] 1.014 to 1.985, p = 0.041) and the composite outcomes of cardiac mortality and/or heart failure readmission (aHR 1.313, 95% CI 1.027 to 1.678, p = 0.030). Patients who developed NOP-LBBB with pre-TAVI left ventricular ejection fraction (LVEF) <40% were significantly associated with cardiac mortality (aHR 2.049, 95% CI 1.039 to 4.041, p = 0.038), heart failure (aHR 3.990, 95% CI 2.362 to 6.741, p <0.001), and the composite outcome (aHR 2.729, 95% CI 1.703 to 4.374, p <0.001). Although NOP-LBBB with pre-TAVI LVEF >40% had a significant decrease in LVEF 6 to 12 months after TAVI (-1.8 ± 9.7% vs +0.6 ± 8.1%, p = 0.003), NOP-LBBB with pre-TAVI LVEF <40% had a significant increase in LVEF 6 to 12 months after TAVI (+9.7 ± 13.6% vs +13.0 ± 11.7%, p = 0.157). In conclusion, patients with NOP-LBBB without pre-TAVI and post-TAVI PPM developed significantly worse long-term outcomes, especially in patients with pre-TAVI LVEF <40%. Further prospective investigation should be undertaken.


Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia Cardíaca , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Bloqueo de Rama/epidemiología , Bloqueo de Rama/etiología , Bloqueo de Rama/terapia , Insuficiencia Cardíaca/epidemiología , Humanos , Estudios Retrospectivos , Medición de Riesgo/métodos , Volumen Sistólico , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Función Ventricular Izquierda
5.
Clin Case Rep ; 8(9): 1786-1790, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32983496

RESUMEN

Most of the coronary vasospasms were found intraprocedurally, and it is very rare to see late-onset vasospasms that happened a few hours after uncomplicated ablations. The recognition of this rare but potentially life-threatening complication is important to improve the conventional practice of catheter ablation for patients with drug-refractory atrial fibrillation.

6.
JACC Clin Electrophysiol ; 6(3): 295-303, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-32192680

RESUMEN

OBJECTIVES: The aim of this study was to develop and validate a risk prediction model for high-grade atrioventricular block requiring cardiac implantable electronic device (CIED) implantation after transcatheter aortic valve replacement (TAVR). BACKGROUND: High-grade atrioventricular block requiring CIED remains a significant sequelae following TAVR. Although several pre-operative characteristics have been associated with the risk of post-operative CIED implantation, an accurate and validated risk prediction model is not established yet. METHODS: This was a single center, retrospective study of consecutive patients who underwent TAVR from March 10, 2011, to October 8, 2018. This cohort sample was randomly divided into a derivation cohort (group A) and a validation cohort (group B). A scoring system for risk prediction of post-TAVR CIED implantation was devised using logistic regression estimates in group A and the calibration and validation were done in group B. RESULTS: A total of 1,071 patients underwent TAVR during the study period. After excluding pre-existing CIED, a total of 888 cases were analyzed (group A: 507 and group B: 381). Independent predictive variables were as follows: self-expanding valve (1 point), hypertension (1 point), pre-existing first-degree atrioventricular block (1 point), and right bundle branch block (2 points). The resulting score was calculated from the total points. The internal validation in group B showed an ideal linear relationship in calibration plot (R2 = 0.933) and a good predictive accuracy (area under the curve: 0.693; 95% confidence interval: 0.627 to 0.759). CONCLUSIONS: This prediction model accurately predicts post-operative risk of CIED implantation with simple pre-operative parameters.


Asunto(s)
Bloqueo Atrioventricular/cirugía , Estimulación Cardíaca Artificial/estadística & datos numéricos , Marcapaso Artificial/estadística & datos numéricos , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Estudios Retrospectivos , Medición de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/estadística & datos numéricos
7.
JACC Case Rep ; 1(4): 612-615, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34316890

RESUMEN

Carotid sinus syncope due to head and neck cancer is uncommon and the management is challenging. Permanent pacemaker implantation is generally considered but malnutrition with subsequent chemo-radiation increases the risk of device infection. This is a first case report of the sequential use of aminophylline and theophylline for pharmacological temporization. (Level of Difficulty: Advanced.).

8.
Am J Cardiol ; 122(10): 1712-1717, 2018 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-30266255

RESUMEN

Atrioventricular conduction disturbances requiring implantation of permanent pacemaker (PPM) are a common complication following transcatheter aortic valve implantation (TAVI). Previous registry data are conflicting but suggestive of an increased risk in heart failure admissions in the post-TAVI PPM cohort. Given the expanding use of TAVI, the present study evaluates the effects of chronic right ventricular pacing (RV pacing) in post-TAVI patients. This is a single-center study of 672 patients who underwent TAVI from 2011 to 2017 of which 146 underwent PPM. Follow-up 1-year post-TAVI outcome data were available for 55 patients and were analyzed retrospectively. Patients who underwent PPM were more likely to have heart failure admissions (17.1% vs 10.1%; hazard ratio [HR] 1.70; 95% confidence interval [CI] 1.10 to 2.64; p 0.019) and a trend toward increased mortality (21.9% vs 15.4%; HR 1.42; 95% CI 0.99 to 2.05; p 0.062). At 1-year follow-up, 30 of 55 (54.5%) patients demonstrated >40% RV pacing. Compared with patients who had <40% RV pacing, those with >40% RV pacing were more likely to have heart failure admissions (8% vs 40%; HR 5.0; 95% CI 1.23 to 20.27; p 0.007) and demonstrated a trend toward increased mortality (12% vs 33.3%; HR 2.78; 95% CI 0.86 to 9.00; p 0.064). This is suggestive that the post-TAVI PPM cohort is particularly sensitive to chronic RV pacing.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Arritmias Cardíacas/terapia , Ventrículos Cardíacos/fisiopatología , Marcapaso Artificial , Complicaciones Posoperatorias/terapia , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Función Ventricular Derecha/fisiología , Adulto , Anciano , Anciano de 80 o más Años , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/etiología , Causas de Muerte/tendencias , Electrocardiografía , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Ohio/epidemiología , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Pronóstico , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Tasa de Supervivencia/tendencias
9.
Am J Cardiol ; 101(3): 359-63, 2008 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-18237600

RESUMEN

Postimplant QRS narrowing may predict clinical response after cardiac resynchronization therapy (CRT), but identification of nonresponders remains difficult. We studied the predictive value of electrocardiographic characteristics for mortality or cardiac transplantation in patients after CRT. Patients who had electrocardiograms available for review from before and after CRT device implantation were identified from a clinical database. Bivariate and multivariate Cox regression analyses were performed for the end point of death or transplantation. Of 337 patients (age 65+/-12 years, 76% men, left ventricular ejection fraction 22+/-12%, pre-QRS 175+/-30 ms), 84 died and 7 underwent transplantation during a follow-up of 27+/-15 months. Variables predictive of death or transplantation included QRS increase after CRT (45% vs 32%, p=0.03), older age, higher New York Heart Association class, lower left ventricular ejection fraction, and higher tertile of postimplant QRS (p=0.04), but not preimplant rhythm, QRS duration, or QRS morphology. After adjusting for confounding variables, independent predictors of mortality were older age (hazard ratio [HR] 1.03, 95% confidence interval [CI] 1.00 to 1.05, p=0.04), lack of angiotensin-converting enzyme inhibitor or angiotensin receptor blocker (HR 2.17, 95% CI 1.16 to 4.08, p<0.02), and longer postimplant QRS by tertile (HR 1.50, 95% CI 1.09 to 2.05, p=0.01). In conclusion, wider QRS after CRT device implantation is an independent predictor of mortality or transplantation. In patients with increased QRS durations despite CRT, closer follow-up or reassessment for alternative management strategies may be warranted.


Asunto(s)
Desfibriladores Implantables , Electrocardiografía , Sistema de Conducción Cardíaco/fisiopatología , Insuficiencia Cardíaca/terapia , Marcapaso Artificial , Anciano , Cardiomiopatías/complicaciones , Femenino , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/cirugía , Trasplante de Corazón/estadística & datos numéricos , Humanos , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/complicaciones , Pronóstico , Estudios Retrospectivos , Volumen Sistólico
10.
J Interv Card Electrophysiol ; 13 Suppl 1: 17-21, 2005 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-16133851

RESUMEN

Catheter based treatment of arrhythmia has gained significant attention during the last two decades. Due to the explosive development in ablation treatment of atrial fibrillation, huge interest in new tools was born to help in the atrial fibrillation ablation procedures. The aim of this review is to describe the role of these novel techniques and tools aimed at improving the implementation of catheter based ablations of atrial arrhythmias by focusing on the use of intra-cardiac echocardiogram and robotic navigation.


Asunto(s)
Ablación por Catéter/métodos , Arritmias Cardíacas/diagnóstico por imagen , Arritmias Cardíacas/fisiopatología , Ecocardiografía , Técnicas Electrofisiológicas Cardíacas/métodos , Tabiques Cardíacos/diagnóstico por imagen , Tabiques Cardíacos/fisiopatología , Humanos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...