Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
1.
Clin Res Cardiol ; 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38748208

RESUMEN

BACKGROUND: Right ventricular (RV) dysfunction in patients undergoing transcatheter aortic valve implantation (TAVI) for aortic stenosis (AS) has long been disregarded. We aimed to assess the predictive value of RV to pulmonary artery coupling (RV/PAc), defined as tricuspid annular plane systolic excursion to systolic pulmonary artery pressure, on mortality in different flow types of AS after TAVI. METHODS: All patients undergoing TAVI for AS at our centre between 2018 and 2020 were assessed; 862 patients were analysed. The cohort was dichotomized using a ROC analysis (cut-off 0.512 mm/mmHg), into 429 patients with preserved and 433 patients with reduced RV/PAc. RESULTS: Reduced RV/PAc was associated with male sex and a higher rate of comorbidities. Short-term VARC-3 endpoints and NYHA classes at follow-up were comparable. Reduced RV/PAc was associated with higher 2-year all-cause mortality (35.0% [30.3-39.3%] vs. 15.4% [11.9-18.7%], hazard ratio 2.5 [1.9-3.4], p < 0.001). Cardiovascular mortality was almost tripled. Results were consistent after statistical adjustment and in a multivariate model. Sub-analyses of AS flow types revealed lower RV/PAc in classical and paradoxical low-flow low-gradient AS, with the majority having reduced RV/PAc (74% and 59%). RV/PAc retained its predictive value in these subgroups. CONCLUSIONS: RV dysfunction defined by low RV/PAc is a strong mortality predictor after TAVI independent of flow group. It should be incorporated in future TAVI risk assessment.

2.
JACC Cardiovasc Interv ; 17(8): 1020-1028, 2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38658116

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is an effective and safe therapy for severe aortic stenosis. Rapid or fast pacing is required for implantation, which can be performed via a pre-existing cardiac implantable electric device (CIED). However, safety data on CIEDs for pacing in TAVR are missing. OBJECTIVES: The aim of this study was to elucidate procedural safety and feasibility of internal pacing with a CIED in TAVR. METHODS: Patients undergoing TAVR with a CIED were included in this analysis. Baseline characteristics, procedural details, and complications according to Valve Academic Research Consortium 3 (VARC-3) criteria after TAVR were compared between both groups. RESULTS: A total of 486 patients were included. Pacing was performed using a CIED in 150 patients and a transient pacemaker in 336 patients. No differences in technical success according to VARC-3 criteria or procedure duration occurred between the groups. The usage of transient pacers for pacing was associated with a significantly higher bleeding rate (bleeding type ≥2 according to VARC-3-criteria; 2.0% vs 13.1%; P < 0.01). Furthermore, impairment of the CIED appeared in 2.3% of patients after TAVR only in the group in which pacing was performed by a transient pacer, leading to surgical revision of the CIED in 1.3% of all patients when transient pacemakers were used. CONCLUSIONS: Internal pacing using a CIED is safe and feasible without differences of procedural time and technical success and might reduce bleeding rates. Furthermore, pacing using a CIED circumvents the risk of lead dislocation. Our data provide an urgent call for the use of a CIED for pacing during a TAVR procedure in general.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Estimulación Cardíaca Artificial , Estudios de Factibilidad , Hospitales de Alto Volumen , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Resultado del Tratamiento , Factores de Tiempo , Anciano , Factores de Riesgo , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Medición de Riesgo
3.
JACC Cardiovasc Interv ; 17(1): 76-87, 2024 Jan 08.
Artículo en Inglés | MEDLINE | ID: mdl-38199755

RESUMEN

BACKGROUND: Knowledge about atrial functional tricuspid regurgitation (afTR) in transcatheter aortic valve replacement (TAVR) patients is scarce. OBJECTIVES: The aim of the study was to analyze the association between the entity and the development of tricuspid regurgitation (TR) in patients undergoing TAVR for aortic stenosis and concomitant TR. METHODS: We analyzed patients undergoing TAVR for severe aortic stenosis from January 2013 to December 2020 and concomitant at least moderate TR at baseline. afTR was defined as enlargement of the right atrium in relation to the right ventricle. TR development after TAVR and 3-year all-cause mortality were evaluated. RESULTS: Out of 3,474 TAVR patients, we identified 420 patients with concomitant at least moderate TR. A total of 363 patients were included in the study, with 178 patients stratified in the afTR and 185 in the non-afTR group based on a receiver-operating characteristic curve cutoff of 1.132 of the right atrial/right ventricular area ratio. TR improvement after TAVR was observed in significantly less patients with afTR compared with non-afTR (31.1% vs 60.6%; P < 0.001). Multivariate regression analysis confirmed afTR as independent predictor for TR persistence (adjusted OR: 2.80; 95% CI: 1.66-4.76; P < 0.001). Moreover, afTR was associated with aggravation of TR after TAVR (17.0% vs 6.8%; P = 0.013). Three-year all-cause mortality was significantly higher in patients with persistence compared with patients with improvement of TR (P < 0.001). CONCLUSIONS: In TAVR patients, afTR is an independent predictor for TR persistence. Moreover, TR persistence is associated with increased 3-year all-cause mortality.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Atrios Cardíacos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía
4.
Catheter Cardiovasc Interv ; 103(1): 186-193, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38140761

RESUMEN

BACKGROUND: Patients undergoing transcatheter aortic valve implantation (TAVI) frequently have coronary artery disease requiring percutaneous coronary intervention (PCI). Usually, PCI and TAVI are performed in two separate procedures and current studies are investigating potential benefits regarding the order. However, the two interventions may also be performed simultaneously, thereby limiting the risk associated with repeated vascular access. Data evaluating benefit and harm of concomitant procedures are scarce. AIMS: Therefore, this study aimed to evaluate concomitant PCI (coPCI) in TAVI patients regarding Valve Academic Research Consortium 3 (VARC-3) endpoints and long-term mortality. METHODS: A total of 2233 consecutive TAVI patients from the EVERY-VALVE registry were analyzed according to the VARC-3 endpoint definitions. A total of 274 patients had undergone TAVI and concomitant PCI (coPCI group). They were compared to 226 TAVI patients who had received PCI within 60 days before TAVI in a stepwise approach (swPCI group) and to the remaining 1733 TAVI patients who had not undergone PCI recently (noPCI group). RESULTS: Overall median age was 81.4 years, median Society of Thoracic Surgeons score was 4.0%. Patients in the coPCI and in the swPCI group were predominantly male with reduced left-ventricular ejection fraction. Rates of VARC-3 composite endpoints technical success and 30-day device success were comparable between all three groups. Mortality rates at 3 years after TAVI were similar (coPCI, 34.2% vs. swPCI, 31.9% vs. noPCI, 34.0% p = 0.84). CONCLUSIONS: coPCI during TAVI seems comparable in a retrospective analysis. Compared to a stepwise approach, it has similar rates of composite endpoints technical success and device success as well as long-term mortality.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Intervención Coronaria Percutánea , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Anciano de 80 o más Años , Femenino , Estudios Retrospectivos , Volumen Sistólico , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Resultado del Tratamiento , Función Ventricular Izquierda , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Factores de Riesgo
5.
JACC Cardiovasc Interv ; 16(16): 1965-1973, 2023 08 28.
Artículo en Inglés | MEDLINE | ID: mdl-37648344

RESUMEN

BACKGROUND: Patients with severe aortic regurgitation (AR) are often not considered for surgery because of increased surgical risk. Because of unique anatomical characteristics among patients with AR, interventional treatment options are limited, and implantation results are inconsistent compared with those among patients with aortic stenosis. OBJECTIVES: The authors describe the initial commercial experience of the first Conformité Européenne-marked transfemoral transcatheter aortic valve replacement system (JenaValve Trilogy [JV]) for the treatment of patients with AR. METHODS: This multicenter registry included 58 consecutive patients from 6 centers across Germany. Transcatheter aortic valve replacement was performed with the JV system for isolated severe and symptomatic AR. Patient characteristics, primary implantation outcomes, and valve performance up to 30 days were analyzed using Valve Academic Research Consortium 3 definitions. RESULTS: The mean patient age was 76.5 ± 9 years, with a mean Society of Thoracic Surgeons score of 4.2% ± 4.3%. Device success was achieved in 98% of patients. The mean gradient was 4.3 ± 1.6 mm Hg, and no moderate or severe paravalvular regurgitation occurred. No conversion to open heart surgery or valve embolization was reported. There were no major vascular complications or bleeding events. The rate of new permanent pacemaker implantation was 19.6%. At 30 days, 92% of the patients were in NYHA functional class I or II, and the 30-day mortality rate was 1.7%. CONCLUSIONS: Treatment of patients with severe symptomatic AR using the transfemoral JV system is safe and effective. Given its favorable hemodynamic performance and low complication rates, this system may offer a new treatment option for patients with AR not suitable for surgery.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano , Anciano de 80 o más Años , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Corazón , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía
6.
Clin Res Cardiol ; 112(10): 1427-1435, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37337011

RESUMEN

BACKGROUND: Cardiohepatic syndrome (CHS) has been identified as an important but underrecognized survival predictor in multiple cardiovascular disease entities. The objectives of this study were to evaluate the prevalence and prognostic value of CHS in patients undergoing TAVR for severe aortic stenosis (AS). METHODS: The study included patients with available laboratory parameters of hepatic function who underwent TAVR from July 2013 until December 2019 at our center. CHS was defined as an elevation of at least two of three laboratory cholestasis parameters above the upper limit of normal (bilirubin, alkaline phosphatase, and gamma glutamyl transferase). Study endpoints were three-year survival, technical and device failure (VARC 3), as well as New York Heart Association (NYHA) functional class at follow-up. RESULTS: Among a total of 953 analyzed patients (47.6% females, median age 80.0 [76.0-85.0] years) CHS was present in 212 patients (22.4%). In patients with vs. without CHS, rates of technical (6.1% vs. 8.4%, p = 0.29) and device failure (18.9% vs. 17.3%, p = 0.59) were comparable. NYHA functional class at baseline and follow-up was more severe in patients with CHS. Nevertheless, heart failure symptoms improved from baseline to follow-up irrespective of hepatic function. Three-year survival rates were significantly lower in patients with CHS (49.4 vs. 65.4%, p < 0.001). The predictive value of CHS persisted after adjustment in a multivariable analysis (hazard ratio 1.58, p < 0.01). CONCLUSION: In patients undergoing TAVR, CHS is prevalent in 22% of patients and is associated with increased postinterventional mortality. Thus, CHS should be included in the decision-making process within the TAVR heart team. Cardiohepatic syndrome (CHS) as defined by an elevation of at least two of three laboratory cholestasis parameters above the upper limit of normal was prevalent in 22% of patients undergoing TAVR for severe AS. The presence of CHS was associated with more severe heart failure symptoms and worse three-year survival.


Asunto(s)
Estenosis de la Válvula Aórtica , Colestasis , Insuficiencia Cardíaca , Reemplazo de la Válvula Aórtica Transcatéter , Femenino , Humanos , Anciano de 80 o más Años , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Válvula Aórtica/cirugía , Factores de Riesgo
7.
EuroIntervention ; 19(6): 526-536, 2023 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-37042426

RESUMEN

BACKGROUND: Concomitant moderate/severe mitral regurgitation (MR) is observed in 17-35% of patients undergoing transcatheter aortic valve implantation (TAVI) and contributes to a worse prognosis. Studies analysing outcomes in patients undergoing TAVI with different MR aetiologies, including atrial functional MR (aFMR), are lacking. AIMS: We aimed to analyse outcomes and changes in MR severity in patients with aFMR, ventricular functional (vFMR) and primary mitral regurgitation (PMR) following TAVI. METHODS: We analysed all consecutive patients with at least moderate MR undergoing TAVI between January 2013 and December 2020 at the Munich University Hospital. Characterisation of MR aetiology was performed by detailed individual echocardiographic assessment. Three-year mortality, changes in MR severity and New York Heart Association (NYHA) Functional Class at follow-up were assessed. RESULTS: Out of 3,474 patients undergoing TAVI, 631 patients showed MR ≥2+ (172 with aFMR, 296 with vFMR, 163 with PMR). Procedural characteristics and endpoints were comparable between groups. The rate of MR improvement was 80.2% in aFMR patients, which was significantly higher compared to both other groups (vFMR: 69.4%; p=0.03; PMR: 40.8%; p<0.001). The estimated 3-year survival rates did not differ between aetiologies (p=0.57). However, MR persistence at follow-up was associated with increased mortality (hazard ratio 1.49, 95% confidence interval: 1.04-2.11; p=0.027), mainly driven by the PMR subgroup of patients. NYHA Class improved significantly in all groups. In patients with baseline MR ≥3+, the PMR aetiology was associated with the lowest MR improvement, the lowest survival rates and least symptomatic improvement. CONCLUSIONS: TAVI reduces MR severity and symptoms in patients with aFMR, vFMR and less-pronounced PMR. The presence of aFMR was associated with the greatest MR severity improvement.


Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia de la Válvula Mitral , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Resultado del Tratamiento , Pronóstico , Ecocardiografía , Estenosis de la Válvula Aórtica/diagnóstico , Índice de Severidad de la Enfermedad , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía
8.
Front Cardiovasc Med ; 10: 1106114, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36776253

RESUMEN

Background: Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) is a valuable treatment option for patients in cardiogenic shock, but complications during decannulation may worsen the overall outcome. Therefore, the aim of this study was to compare the efficacy and safety of suture-based to pure plug-based vascular closure devices for VA-ECMO decannulation. Methods: In this retrospective study, the procedural outcome of 33 patients with suture-based Perclose ProGlide closure devices was compared to 38 patients with MANTA plug-based closure devices. Results: Rate of technically correct placement of closure devices was 88% in the suture-based group and 97% in the plug-based group (p = 0.27). There was a significant reduction of severe bleeding events during VA-ECMO decannulation in plug-based versus suture-based systems (3% vs. 21%, p = 0.04). Ischemic complications occurred in 6% with suture-based and 5% with plug-based device (p = 1.00). Pseudoaneurysm formation was detected in 3% in both groups (p = 1.00). No switch to vascular surgery due to bleeding after decannulation was necessary in both groups. Conclusion: Based on our retrospective analysis, we propose that plug-based vascular closure should be the preferred option for VA-ECMO decannulation. This hypothesis should be further tested in a randomized trial.

9.
Int J Cardiol ; 376: 100-107, 2023 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-36758861

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is a well-established, safe and effective therapy for severe symptomatic aortic stenosis (AS). The aim of this study was to objectively quantify improvement of physical activity after TAVR, with consideration of different low-gradient AS subtypes. METHODS AND RESULTS: All patients undergoing TAVR for severe AS were screened. Participants received a wearable activity tracker (Fitbit®) at hospital discharge following TAVR and 6 months thereafter. The difference of median daily steps was defined as surrogate outcome for physical activity. For analysis, patients were grouped into high-gradient (HG) AS (dPmean ≥40 mmHg), classical low-flow low-gradient (LFLG) AS (dPmean <40 mmHg, EF <50%), paradoxical LFLG-AS (dPmean <40 mmHg, EF ≥50%, SVi ≤35 ml/m2) and normal-flow low-gradient (NFLG) AS (dPmean <40 mmHg, EF ≥50%, SVi >35 ml/m2) according to mean transvalvular pressure gradient (dPmean), stroke volume index (SVi) and left-ventricular ejection fraction (LVEF). RESULTS AND CONCLUSIONS: The analysis is based on 230 patients. The median daily step count was 4409 [IQR 2581-7487] after hospital discharge and 5326 [IQR 3045-8668] 6 months thereafter. Median difference of daily steps was ∆529 [IQR -702-2152]). Patients with HG-AS and paradoxical LFLG-AS showed a significant improvement of daily steps (∆951 [IQR -378-2323], p <0.001 and (∆1392 [IQR -609-4444], p = 0.02, respectively). Patients with classical LFLG-AS showed no statistically relevant improvement of daily steps (∆192 [IQR -687-770], p = 0.79). Patients with NFLG-AS showed a numerical decline in daily steps without statistical significance (∆-300 [IQR -1334-1406], p = 0.67). This first prospective study of this sample size shows significant improvement of physical activity after TAVR with an objective and reproducible method. This was mainly driven by an improvement in patients with HG-AS and paradoxical LFLG-AS.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/cirugía , Estudios Prospectivos , Volumen Sistólico , Función Ventricular Izquierda , Estenosis de la Válvula Aórtica/cirugía , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Ejercicio Físico , Resultado del Tratamiento , Índice de Severidad de la Enfermedad
10.
Clin Res Cardiol ; 112(5): 645-655, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36637479

RESUMEN

AIM: The aim of this study was to analyse the predictive value of CTA-determined tricuspid annular dilatation (TAD) on the persistence of tricuspid regurgitation (TR) in patients undergoing transcatheter aortic valve replacement (TAVR) for severe aortic stenosis (AS) and concomitant at least moderate TR. METHODS AND RESULTS: 288 consecutive patients treated with TAVR due to severe AS and concomitant at least moderate TR at baseline were included in the analysis. As cutoff for TAD, the median value of the CTA-determined, to the body surface area-normalized tricuspid annulus diameter (25.2 mm/m2) was used. TAD had no impact on procedural characteristics or outcomes, including procedural death and technical or device failure according to the Valve Academic Research Consortium 3 criteria. However, the primary outcome of the study-TR persistence after TAVR was significantly more frequent in patients with compared to patients without TAD (odds ratio 2.60, 95% confidence interval 1.33-5.16, p < 0.01). Multivariable logistic regression analysis, adjusting for clinical and echocardiographic baseline characteristics, which are known to influence aetiology or severity of TR, confirmed TAD as an independent predictor of TR persistence after TAVR (adjusted odds ratio 2.30, 95% confidence interval 1.20-4.46, p = 0.01). Moreover, 2 year all-cause mortality was significantly higher in patients with persistence or without change of TR compared to patients with TR improvement (log-rank p < 0.01). CONCLUSION: In patients undergoing TAVR for severe AS and concomitant at least moderate TR at baseline, TAD is a predictor of TR persistence, which is associated with increased 2-year all-cause mortality.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Insuficiencia de la Válvula Tricúspide , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Insuficiencia de la Válvula Tricúspide/diagnóstico , Insuficiencia de la Válvula Tricúspide/etiología , Dilatación/efectos adversos , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estudios Retrospectivos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Índice de Severidad de la Enfermedad
11.
J Clin Med ; 12(1)2023 Jan 02.
Artículo en Inglés | MEDLINE | ID: mdl-36615162

RESUMEN

Background: Heparin-induced thrombocytopenia (HIT) is a serious, immune-mediated adverse drug reaction to unfractionated heparin (UFH) affecting also patients undergoing venoarterial extracorporeal membrane oxygenation (VA-ECMO). Although the association between VA-ECMO support and the development of thrombocytopenia has long been known and discussed, HIT as one underlying cause is still insufficiently understood. Therefore, the purpose of this study was to further investigate the epidemiology, mortality, diagnosis, and clinical management of HIT occurring in VA-ECMO patients treated with UFH. Methods: We conducted a retrospective single-center study including adult patients (≥18 years) with VA-ECMO support in the cardiac intensive care unit (ICU) of the University Hospital of Munich (LMU) between January 2013 and May 2022, excluding patients with a known history of HIT upon admission. Differences in baseline characteristics and clinical outcome between excluded HIT (positive anti-platelet factor 4 (PF4)/heparin antibody test but negative functional assay) and confirmed HIT (positive anti-PF4/heparin antibody test and positive functional assay) VA-ECMO patients as well as diagnosis and clinical management of HIT were analysed. Results: Among the 373 patients included, anti-PF4/heparin antibodies were detected in 53/373 (14.2%) patients. Functional HIT testing confirmed HIT in 13 cases (3.5%) and excluded HIT in 40 cases (10.7%), corresponding to a prevalence of confirmed HIT of 13/373 (3.5%) [1.6, 5.3] and a positive predictive value (PPV) of 24.5% for the antibody screening test. The platelet course including platelet recovery following argatroban initiation was similar between all groups. One-month mortality in patients with excluded HIT was 14/40 (35%) and 3-month mortality 17/40 (43%), compared to 5/13 (38%) (p > 0.999), and 6/13 (46%) (p > 0.999) in patients with confirmed HIT. Neurological outcome in both groups measured by the cerebral performance category of survivors on hospital discharge was similar, as well as adverse events during VA-ECMO therapy. Conclusions: With a prevalence of 3.5%, HIT is a non-frequent complication in patients on VA-ECMO and was not associated with a higher mortality rate. HIT was ultimately excluded by functional essay in 75% of VA-ECMO patients with clinical suspicion of HIT and positive anti-PF4/heparin antibody test. Argatroban seems to be an appropriate and safe therapeutic option for confirmed HIT-positive patients on VA-ECMO support.

12.
Int J Cardiol ; 371: 299-304, 2023 01 15.
Artículo en Inglés | MEDLINE | ID: mdl-36306951

RESUMEN

BACKGROUND: Normal-flow (stroke volume index, SVi >35 ml/m2) low-gradient (dPmean <40 mmHg) aortic stenosis (NFLG-AS) is subject of scientific debate. Guidelines fail to give conclusive treatment recommendations. We hypothesized that NFLG patients are heterogenous, containing a subgroup similar to high-gradient aortic stenosis patients (dPmean ≥40 mmHg, HG-AS) concerning characteristics and outcomes. METHODS: 2326 patients undergoing transcatheter aortic valve replacement (TAVI) at our centre between 2013 and 2019 were analysed. 386 patients fulfilled criteria of NFLG-AS. Their median dPmean was 33 mmHg, which was used for grouping (204 patients with higher gradient NFLG-AS, 186 patients with lower gradient NFLG-AS). They were compared to 956 HG-AS patients. RESULTS: Characteristics of lower gradient NFLG-AS patients differed from HG-AS patients in many aspects while higher gradient NFLG-AS and HG-AS patients were mostly similar, underscored by higher Society of Thoracic Surgeons scores in lower gradient NFLG-AS (lower gradient NFLG-AS, 3.9, HG-AS, 3.0, p = 0.03, higher gradient NFLG-AS, 3.0, p = 0.04). Procedural complications were comparable. Estimated 3-year all-cause mortality was higher in lower gradient NFLG-AS compared to HG-AS patients (hazard ratio 1.7, p < 0.01), whereas mortality of higher gradient NFLG-AS was similar to HG-AS patients (hazard ratio 1.2, p = 0.31). Cardiovascular mortality was highest among lower gradient NFLG-AS patients (21.6% vs. higher gradient NFLG-AS, 15.4%, vs. HG-AS, 11.1%, p < 0.01). CONCLUSIONS: NFLG-AS patients are indeed heterogenous. NFLG-AS patients with higher gradients resemble HG-AS patients in clinical characteristics and outcomes and should not be treated differently. Lower gradient NFLG-AS patients have increased long-term mortality and the use of TAVI requires careful consideration.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/cirugía , Función Ventricular Izquierda , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Volumen Sistólico , Índice de Severidad de la Enfermedad
13.
J Cardiovasc Transl Res ; 16(1): 152-154, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-35668315

RESUMEN

Our study investigated the feasibility to measure pressure profiles inside the inflation balloon during direct implantation of Edwards Sapien 3 ultra-prostheses using an additional syringe with a digital pressure read-out. Pressure profiles of 15 patients for 26 mm valve size were analyzed. Uniform patterns were found for 5 patients similar to those of previously acquired in vitro curves. 10 patients showed strikingly different pressure profiles compared to the above-mentioned group, marked by an earlier pressure increase, single or multiple pressure drops or higher overall pressure. Measuring the percentage of under-expansion of the prostheses, using calibrated angiographic projections revealed a significant difference between both groups. Our data raises the hypothesis that the acquisition of pressure profiles might help to better understand not only the implantation procedure itself but also the highly individual patient-device interaction, offering new information and a new perspective on optimization of TAVR implantation in the future.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estudios de Factibilidad , Resultado del Tratamiento , Diseño de Prótesis
14.
Eur Heart J Acute Cardiovasc Care ; 11(12): 877-886, 2022 Dec 27.
Artículo en Inglés | MEDLINE | ID: mdl-36210517

RESUMEN

AIMS: Severe aortic stenosis can cause acute heart failure and cardiogenic shock (CS). Transcatheter aortic valve implantation (TAVI) is the standard therapy for aortic stenosis in inoperable patients. However, its role in this setting is poorly evaluated. The study purpose was to explore clinical characteristics of these patients and to assess predictors of mortality. METHODS AND RESULTS: All 2930 patients undergoing transfemoral TAVI at our centre between 2013 and 2019 were screened for critically ill patients, receiving intensive care therapy and emergency TAVI. Selected patients were subdivided into two groups, according to the presence or absence of CS. Remaining patients undergoing elective TAVI served as a comparison. Primary outcome was 90-day mortality. Out of 179 critically ill patients, 47 fulfilled criteria of CS (shock group) and 132 did not despite a severe decompensation (no shock group). Shock patients were more often male and had higher Society of Thoracic Surgeons scores [15.6, interquartile range (8.0-32.1) vs. 5.5 (3.9-8.5), P < 0.01] compared with severely decompensated patients. Ninety-day mortality was: shock group, 42.6%, vs. no shock group, 15.9%, vs. elective group, 5.3% (P < 0.01). A landmark analysis from day 90 showed similar mortality (P = 0.29). Compared with elective patients, 30-day composite endpoint device failure was higher in critically ill groups [shock group, odds ratio, 2.86 (1.43-5.36), no shock group, odds ratio, 1.74 (1.09-2.69)]. Multivariable regression revealed mechanical ventilation, haemofiltration, elevated C-reactive protein or bilirubin, and hypotension before TAVI as 90-day mortality predictors. CONCLUSION: Ninety-day mortality after TAVI in critically ill patients is increased but survivors have similar outcomes as elective patients.


Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia Cardíaca , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Choque Cardiogénico/etiología , Choque Cardiogénico/cirugía , Enfermedad Crítica , Factores de Riesgo , Resultado del Tratamiento , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/cirugía
15.
J Am Heart Assoc ; 11(21): e026539, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36285786

RESUMEN

Cardiac arrest still accounts for a substantial proportion of cardiovascular related deaths and is associated with a tremendous risk of neurological injury and, among the few survivors, poor quality of life. Critical determinants of survival and long-term functional status after cardiac arrest are timely initiation of cardiopulmonary resuscitation and use of an external defibrillator for patients with a shockable rhythm. Outcomes are still far from satisfactory, despite ongoing efforts to improve cardiac arrest response systems, as well as elaborate postresuscitation algorithms. Targeted temperature management at the wide range between 32 °C and 36 °C has been one of the main therapeutic strategies to improve neurological outcome in postresuscitation care. This recommendation has been mainly based on 2 small randomized trials that were published 20 years ago. Most recent data derived from the TTM2 (Targeted Hypothermia Versus Targeted Normothermia After Out-of-Hospital Cardiac Arrest) trial, which included 1861 patients, challenge this strategy. It showed no benefit of targeted hypothermia at 33 °C over normothermia at 36 °C to 37.5 °C with fever prevention. Because temperature management at lower temperatures also correlated with an increased risk of side effects without any benefit in the TTM2 trial, a modification of the guidelines with harmonizing temperature management to normothermia might be necessary.


Asunto(s)
Reanimación Cardiopulmonar , Hipotermia Inducida , Hipotermia , Paro Cardíaco Extrahospitalario , Humanos , Calidad de Vida , Hipotermia Inducida/efectos adversos , Hipotermia Inducida/métodos , Paro Cardíaco Extrahospitalario/terapia , Reanimación Cardiopulmonar/métodos
16.
EuroIntervention ; 18(10): 812-819, 2022 Nov 18.
Artículo en Inglés | MEDLINE | ID: mdl-35903846

RESUMEN

BACKGROUND: Large-bore arteriotomy for transcatheter aortic valve implantation (TAVI) requires percutaneous vascular closure devices, but real-world data comparing different closure strategies are limited. AIMS: We sought to compare a dual ProGlide strategy vs a combination of one ProGlide and one FemoSeal for vascular closure after TAVI. METHODS: We retrospectively analysed 874 propensity score-matched patients undergoing TAVI at the Munich University Hospital from August 2018 to October 2020. From August 2018 to August 2019, a dual ProGlide strategy was used for vascular closure. From October 2019 to October 2020, a combination of one ProGlide and one FemoSeal was used. The primary endpoint was defined as access-related major vascular complications or bleeding ≥Type 2 according to Valve Academic Research Consortium 3 criteria. RESULTS: Patients in the dual ProGlide group (n=437) had a higher incidence of the primary endpoint than patients treated with one ProGlide and one FemoSeal (n=437; 11.4% vs 3.0%; p<0.001). Furthermore, they had a higher rate of closure device failure (2.7% vs 0.9%; p=0.044) and more often required unplanned surgery or endovascular treatment (3.9% vs 0.9%; p=0.004). The incidence of death did not differ significantly between groups (3.4% vs 1.6%; p=0.08). CONCLUSIONS: A combined ProGlide and FemoSeal strategy might have the potential to reduce access-related vascular complications following TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Dispositivos de Cierre Vascular , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Estudios Retrospectivos , Arteria Femoral/cirugía , Resultado del Tratamiento , Dispositivos de Cierre Vascular/efectos adversos , Hemostasis , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Técnicas Hemostáticas/efectos adversos
18.
J Cardiovasc Comput Tomogr ; 16(5): 423-430, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35637128

RESUMEN

BACKGROUND: Computed tomography (CT) imaging is the standard of care before transcatheter aortic valve replacement (TAVR). The aortic annulus undergoes conformational changes during the heart cycle. Therefore, the image acquisition time point can impact prosthesis sizing and fit. Clinical outcome data are lacking. The aim of this study was to compare systolic and diastolic cardiac CT data acquisition with regard to procedural and clinical outcomes in patients undergoing TAVR for severe aortic stenosis (AS). METHODS: Preprocedural high-pitch helical CT datasets were analyzed in 1954 patients undergoing TAVR between 2013 and 2018 â€‹at our center. Patients were stratified into two groups according to the acquisition heart phase (979 systolic and 975 diastolic). The study was approved by the local ethics committee. RESULTS: Median age was 81.6 [interquartile range 77.5-85.8] years and 964 (49.3%) patients were male. No significant difference was found for the Valve Academic Research Consortium-3 (VARC-3) endpoints of technical failure (systolic, 5.1% vs. diastolic, 5.2%, p â€‹= â€‹0.94) or device failure (systolic, 13.7% vs. diastolic, 13.5%, p â€‹= â€‹0.92). There was no difference in paravalvular regurgitation. All-cause 30-day mortality was comparable (systolic, 3.6% [95% confidence interval, 2.4-4.7%] vs. diastolic, 3.6% [2.4-4.8%], p â€‹= â€‹1.00), while 3-year mortality rates were higher in the diastolic group (Society of Thoracic Surgeons score adjusted hazard ratio, 1.25 [1.07-1.46], p â€‹< â€‹0.01). CONCLUSIONS: While the 30-day technical and clinical outcomes after TAVR are comparable between systolic and diastolic CT imaging, diastolic imaging was associated with higher long-term mortality. Therefore, the data support the guideline recommendation of systolic imaging.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , Femenino , Soplos Cardíacos/etiología , Humanos , Masculino , Valor Predictivo de las Pruebas , Factores de Riesgo , Tomografía Computarizada por Rayos X/métodos , Resultado del Tratamiento
19.
J Clin Med ; 11(6)2022 Mar 12.
Artículo en Inglés | MEDLINE | ID: mdl-35329887

RESUMEN

Despite the rapid increase in experience and technological improvement, the incidence of conduction disturbances in patients undergoing transcatheter aortic valve replacement (TAVR) with the self-expandable CoreValve Evolut valve remains high. Recently, a cusp-overlap view (COP) implantation technique has been proposed for TAVR with self-expandable valves offering an improved visualization during valve expansion compared to the three-cusp view (TCV). This study aims to systematically analyze procedural outcomes of TAVR patients treated with the CoreValve Evolut valve using a COP compared to TCV in a high-volume center. The primary endpoint was technical success according the 2021 VARC-3 criteria. A total of 122 consecutive patients (61 pts. TCV: April 2019 to November 2020; 61 pts. COP: December 2020 to October 2021) that underwent TAVR with the CoreValve Evolut prosthesis were included in this analysis. Although there was no difference in the primary endpoint technical success between TCV and COP patients (93.4% vs. 90.2%, OR 0.65, 95% CI 0.16, 2.4, p = 0.51), we observed a significantly lower risk for permanent pacemaker implantation (PPI) among COP patients (TCV: 27.9% vs. COP: 13.1%, OR 0.39, 95% CI 0.15, 0.97, p = 0.047). Implantation of the CoreValve Evolut prosthesis using the COP might help to reduce the rate of PPI following TAVR.

20.
Clin Res Cardiol ; 111(12): 1325-1335, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35320407

RESUMEN

OBJECTIVES: The study objective was to characterize different groups of low-flow low-gradient (LFLG) aortic stenosis (AS) and determine short-term outcomes and long-term mortality according to Valve Academic Research Consortium-3 (VARC-3) endpoint definitions. BACKGROUND: Characteristics and outcomes of patients with LFLG AS undergoing transcatheter aortic valve implantation (TAVI) are poorly understood. METHODS: All patients undergoing TAVI at our center between 2013 and 2019 were screened. Patients were divided into three groups according to mean pressure gradient (dPmean), ejection fraction (LVEF), and stroke volume index (SVi): high gradient (HG) AS (dPmean ≥ 40 mmHg), classical LFLG (cLFLG) AS (dPmean < 40 mmHg, LVEF < 50%), and paradoxical LFLG (pLFLG) AS (dPmean < 40 mmHg, LVEF ≥ 50%, SVi ≤ 35 ml/m2). RESULTS: We included 1776 patients (956 HG, 447 cLFLG, and 373 pLFLG patients). Most baseline characteristics differed significantly. Median Society of Thoracic Surgeons (STS) score was highest in cLFLG, followed by pLFLG and HG patients (5.0, 3.9 and 3.0, respectively, p < 0.01). Compared to HG patients, odds ratios for the short-term VARC-3 composite endpoints, technical failure (cLFLG, 0.76 [95% confidence interval, 0.40-1.36], pLFLG, 1.37 [0.79-2.31]) and device failure (cLFLG, 1.06 [0.74-1.49], pLFLG, 0.97 [0.66-1.41]) were similar, without relevant differences within LFLG patients. NYHA classes improved equally in all groups. Compared to HG, LFLG patients had a higher 3-year all-cause mortality (STS score-adjusted hazard ratios, cLFLG 2.16 [1.77-2.64], pLFLG 1.53 [1.22-193]), as well as cardiovascular mortality (cLFLG, 2.88 [2.15-3.84], pLFLG, 2.08 [1.50-2.87]). CONCLUSIONS: While 3-year mortality remains high after TAVI in LFLG compared to HG patients, symptoms improve in all subsets after TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Índice de Severidad de la Enfermedad , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Volumen Sistólico , Función Ventricular Izquierda , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...