Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Influenza Other Respir Viruses ; 12(5): 613-622, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29768714

RESUMEN

BACKGROUND: In December 2016, an outbreak of low pathogenicity avian influenza (LPAI) A(H7N2) occurred in cats at a New York City animal shelter and quickly spread to other shelters in New York and Pennsylvania. The A(H7N2) virus also spread to an attending veterinarian. In response, 500 cats were transferred from these shelters to a temporary quarantine facility for continued monitoring and treatment. OBJECTIVES: The objective of this study was to assess the occupational risk of A(H7N2) exposure among emergency response workers at the feline quarantine facility. METHODS: Aerosol and surface samples were collected from inside and outside the isolation zones of the quarantine facility. Samples were screened for A(H7N2) by quantitative RT-PCR and analyzed in embryonated chicken eggs for infectious virus. RESULTS: H7N2 virus was detected by RT-PCR in 28 of 29 aerosol samples collected in the high-risk isolation (hot) zone with 70.9% on particles with aerodynamic diameters >4 µm, 27.7% in 1-4 µm, and 1.4% in <1 µm. Seventeen of 22 surface samples from the high-risk isolation zone were also H7N2 positive with an average M1 copy number of 1.3 × 103 . Passage of aerosol and surface samples in eggs confirmed that infectious virus was present throughout the high-risk zones in the quarantine facility. CONCLUSIONS: By measuring particle size, distribution, and infectivity, our study suggests that the A(H7N2) virus had the potential to spread by airborne transmission and/or direct contact with viral-laden fomites. These results warranted continued A(H7N2) surveillance and transmission-based precautions during the treatment and care of infected cats.


Asunto(s)
Enfermedades de los Gatos/epidemiología , Brotes de Enfermedades , Microbiología Ambiental , Subtipo H7N2 del Virus de la Influenza A/aislamiento & purificación , Infecciones por Orthomyxoviridae/veterinaria , Cuarentena , Medicina Veterinaria/métodos , Animales , Enfermedades de los Gatos/virología , Gatos , Ciudad de Nueva York/epidemiología , Exposición Profesional , Infecciones por Orthomyxoviridae/epidemiología , Infecciones por Orthomyxoviridae/virología , Medición de Riesgo , Zoonosis/transmisión
2.
J Occup Environ Hyg ; 15(1): 1-12, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-29059039

RESUMEN

Ambulances are frequently contaminated with infectious microorganisms shed by patients during transport that can be transferred to subsequent patients and emergency medical service workers. Manual decontamination is tedious and time-consuming, and persistent contamination is common even after cleaning. Ultraviolet germicidal irradiation (UVGI) has been proposed as a terminal disinfection method for ambulance patient compartments. However, no published studies have tested the use of UVGI in ambulances. The objectives of this study were to investigate the efficacy of a UVGI system in an ambulance patient compartment and to examine the impact of UVGI fixture position and the UV reflectivity of interior surfaces on the time required for disinfection. A UVGI fixture was placed in the front, middle, or back of an ambulance patient compartment, and the UV irradiance was measured at 49 locations. Aluminum sheets and UV-reflective paint were added to examine the effects of increasing surface reflectivity on disinfection time. Disinfection tests were conducted using Bacillus subtilis spores as a surrogate for pathogens. Our results showed that the UV irradiance varied considerably depending upon the surface location. For example, with the UVGI fixture in the back position and without the addition of UV-reflective surfaces, the most irradiated location received a dose of UVGI sufficient for disinfection in 16 s, but the least irradiated location required 15 hr. Because the overall time required to disinfect all of the interior surfaces is determined by the time required to disinfect the surfaces receiving the lowest irradiation levels, the patient compartment disinfection times for different UVGI configurations ranged from 16.5 hr to 59 min depending upon the UVGI fixture position and the interior surface reflectivity. These results indicate that UVGI systems can reduce microbial surface contamination in ambulance compartments, but the systems must be rigorously validated before deployment. Optimizing the UVGI fixture position and increasing the UV reflectivity of the interior surfaces can substantially improve the performance of a UVGI system and reduce the time required for disinfection.


Asunto(s)
Ambulancias , Bacillus subtilis/efectos de la radiación , Desinfección/métodos , Rayos Ultravioleta , Infección Hospitalaria/prevención & control , Desinfección/instrumentación , Pintura , Esporas Bacterianas/efectos de la radiación
3.
Influenza Other Respir Viruses ; 10(5): 404-13, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-26991074

RESUMEN

BACKGROUND: To prepare for a possible influenza pandemic, a better understanding of the potential for the airborne transmission of influenza from person to person is needed. OBJECTIVES: The objective of this study was to directly compare the generation of aerosol particles containing viable influenza virus during coughs and exhalations. METHODS: Sixty-one adult volunteer outpatients with influenza-like symptoms were asked to cough and exhale three times into a spirometer. Aerosol particles produced during coughing and exhalation were collected into liquid media using aerosol samplers. The samples were tested for the presence of viable influenza virus using a viral replication assay (VRA). RESULTS: Fifty-three test subjects tested positive for influenza A virus. Of these, 28 (53%) produced aerosol particles containing viable influenza A virus during coughing, and 22 (42%) produced aerosols with viable virus during exhalation. Thirteen subjects had both cough aerosol and exhalation aerosol samples that contained viable virus, 15 had positive cough aerosol samples but negative exhalation samples, and 9 had positive exhalation samples but negative cough samples. CONCLUSIONS: Viable influenza A virus was detected more often in cough aerosol particles than in exhalation aerosol particles, but the difference was not large. Because individuals breathe much more often than they cough, these results suggest that breathing may generate more airborne infectious material than coughing over time. However, both respiratory activities could be important in airborne influenza transmission. Our results are also consistent with the theory that much of the aerosol containing viable influenza originates deep in the lungs.


Asunto(s)
Aerosoles/análisis , Microbiología del Aire , Tos/virología , Virus de la Influenza A/fisiología , Gripe Humana/transmisión , Viabilidad Microbiana , Adulto , Espiración , Femenino , Humanos , Gripe Humana/prevención & control , Gripe Humana/virología , Masculino , Pandemias/prevención & control , ARN Viral , Espirometría , Replicación Viral , Adulto Joven
4.
J Occup Environ Hyg ; 12(8): 509-17, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25806411

RESUMEN

The ability to disinfect and reuse disposable N95 filtering facepiece respirators (FFRs) may be needed during a pandemic of an infectious respiratory disease such as influenza. Ultraviolet germicidal irradiation (UVGI) is one possible method for respirator disinfection. However, UV radiation degrades polymers, which presents the possibility that UVGI exposure could degrade the ability of a disposable respirator to protect the worker. To study this, we exposed both sides of material coupons and respirator straps from four models of N95 FFRs to UVGI doses from 120-950 J/cm(2). We then tested the particle penetration, flow resistance, and bursting strengths of the individual respirator coupon layers, and the breaking strength of the respirator straps. We found that UVGI exposure led to a small increase in particle penetration (up to 1.25%) and had little effect on the flow resistance. UVGI exposure had a more pronounced effect on the strengths of the respirator materials. At the higher UVGI doses, the strength of the layers of respirator material was substantially reduced (in some cases, by >90%). The changes in the strengths of the respirator materials varied considerably among the different models of respirators. UVGI had less of an effect on the respirator straps; a dose of 2360 J/cm(2) reduced the breaking strength of the straps by 20-51%. Our results suggest that UVGI could be used to effectively disinfect disposable respirators for reuse, but the maximum number of disinfection cycles will be limited by the respirator model and the UVGI dose required to inactivate the pathogen.


Asunto(s)
Desinfección/métodos , Dispositivos de Protección Respiratoria , Rayos Ultravioleta , Equipo Reutilizado , Filtración/instrumentación , Transmisión de Enfermedad Infecciosa de Paciente a Profesional/prevención & control , Ensayo de Materiales/métodos
5.
J Occup Environ Hyg ; 12(2): 107-13, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25523206

RESUMEN

Patients with influenza release aerosol particles containing the virus into their environment. However, the importance of airborne transmission in the spread of influenza is unclear, in part because of a lack of information about the infectivity of the airborne virus. The purpose of this study was to determine the amount of viable influenza A virus that was expelled by patients in aerosol particles while coughing. Sixty-four symptomatic adult volunteer outpatients were asked to cough 6 times into a cough aerosol collection system. Seventeen of these participants tested positive for influenza A virus by viral plaque assay (VPA) with confirmation by viral replication assay (VRA). Viable influenza A virus was detected in the cough aerosol particles from 7 of these 17 test subjects (41%). Viable influenza A virus was found in the smallest particle size fraction (0.3 µm to 8 µm), with a mean of 142 plaque-forming units (SD 215) expelled during the 6 coughs in particles of this size. These results suggest that a significant proportion of patients with influenza A release small airborne particles containing viable virus into the environment. Although the amounts of influenza A detected in cough aerosol particles during our experiments were relatively low, larger quantities could be expelled by influenza patients during a pandemic when illnesses would be more severe. Our findings support the idea that airborne infectious particles could play an important role in the spread of influenza.


Asunto(s)
Aerosoles/análisis , Microbiología del Aire , Tos/virología , Virus de la Influenza A/aislamiento & purificación , Gripe Humana/transmisión , Adolescente , Adulto , Femenino , Humanos , Masculino , Tamaño de la Partícula , ARN Viral/análisis , ARN Viral/aislamiento & purificación , Ensayo de Placa Viral , Replicación Viral
7.
J Occup Environ Hyg ; 9(12): 681-90, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-23033849

RESUMEN

Few studies have quantified the dispersion of potentially infectious bioaerosols produced by patients in the health care environment and the exposure of health care workers to these particles. Controlled studies are needed to assess the spread of bioaerosols and the efficacy of different types of respiratory personal protective equipment (PPE) in preventing airborne disease transmission. An environmental chamber was equipped to simulate a patient coughing aerosol particles into a medical examination room, and a health care worker breathing while exposed to these particles. The system has three main parts: (1) a coughing simulator that expels an aerosol-laden cough through a head form; (2) a breathing simulator with a second head form that can be fitted with respiratory PPE; and (3) aerosol particle counters to measure concentrations inside and outside the PPE and at locations throughout the room. Dispersion of aerosol particles with optical diameters from 0.3 to 7.5 µm was evaluated along with the influence of breathing rate, room ventilation, and the locations of the coughing and breathing simulators. Penetration of cough aerosol particles through nine models of surgical masks and respirators placed on the breathing simulator was measured at 32 and 85 L/min flow rates and compared with the results from a standard filter tester. Results show that cough-generated aerosol particles spread rapidly throughout the room, and that within 5 min, a worker anywhere in the room would be exposed to potentially hazardous aerosols. Aerosol exposure is highest with no personal protective equipment, followed by surgical masks, and the least exposure is seen with N95 FFRs. These differences are seen regardless of breathing rate and relative position of the coughing and breathing simulators. These results provide a better understanding of the exposure of workers to cough aerosols from patients and of the relative efficacy of different types of respiratory PPE, and they will assist investigators in providing research-based recommendations for effective respiratory protection strategies in health care settings.


Asunto(s)
Aerosoles/análisis , Tos , Transmisión de Enfermedad Infecciosa/prevención & control , Transmisión de Enfermedad Infecciosa de Paciente a Profesional/prevención & control , Modelos Teóricos , Exposición Profesional/análisis , Humanos , Exposición por Inhalación/prevención & control , Máscaras , Exposición Profesional/prevención & control , Tamaño de la Partícula , Dispositivos de Protección Respiratoria/normas , Ventilación
8.
Clin Infect Dis ; 54(11): 1569-77, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22460981

RESUMEN

BACKGROUND: The potential for aerosol transmission of infectious influenza virus (ie, in healthcare facilities) is controversial. We constructed a simulated patient examination room that contained coughing and breathing manikins to determine whether coughed influenza was infectious and assessed the effectiveness of an N95 respirator and surgical mask in blocking transmission. METHODS: National Institute for Occupational Safety and Health aerosol samplers collected size-fractionated aerosols for 60 minutes at the mouth of the breathing manikin, beside the mouth, and at 3 other locations in the room. Total recovered virus was quantitated by quantitative polymerase chain reaction and infectivity was determined by the viral plaque assay and an enhanced infectivity assay. RESULTS: Infectious influenza was recovered in all aerosol fractions (5.0% in >4 µm aerodynamic diameter, 75.5% in 1-4 µm, and 19.5% in <1 µm; n = 5). Tightly sealing a mask to the face blocked entry of 94.5% of total virus and 94.8% of infectious virus (n = 3). A tightly sealed respirator blocked 99.8% of total virus and 99.6% of infectious virus (n = 3). A poorly fitted respirator blocked 64.5% of total virus and 66.5% of infectious virus (n = 3). A mask documented to be loosely fitting by a PortaCount fit tester, to simulate how masks are worn by healthcare workers, blocked entry of 68.5% of total virus and 56.6% of infectious virus (n = 2). CONCLUSIONS: These results support a role for aerosol transmission and represent the first reported laboratory study of the efficacy of masks and respirators in blocking inhalation of influenza in aerosols. The results indicate that a poorly fitted respirator performs no better than a loosely fitting mask.


Asunto(s)
Aerosoles , Microbiología del Aire , Tos , Gripe Humana/transmisión , Gripe Humana/virología , Orthomyxoviridae/aislamiento & purificación , Transmisión de Enfermedad Infecciosa/prevención & control , Humanos , Gripe Humana/patología , Máscaras/virología , Reacción en Cadena en Tiempo Real de la Polimerasa , Carga Viral , Ensayo de Placa Viral
9.
PLoS One ; 5(11): e15100, 2010 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-21152051

RESUMEN

Influenza is thought to be communicated from person to person by multiple pathways. However, the relative importance of different routes of influenza transmission is unclear. To better understand the potential for the airborne spread of influenza, we measured the amount and size of aerosol particles containing influenza virus that were produced by coughing. Subjects were recruited from patients presenting at a student health clinic with influenza-like symptoms. Nasopharyngeal swabs were collected from the volunteers and they were asked to cough three times into a spirometer. After each cough, the cough-generated aerosol was collected using a NIOSH two-stage bioaerosol cyclone sampler or an SKC BioSampler. The amount of influenza viral RNA contained in the samplers was analyzed using quantitative real-time reverse-transcription PCR (qPCR) targeting the matrix gene M1. For half of the subjects, viral plaque assays were performed on the nasopharyngeal swabs and cough aerosol samples to determine if viable virus was present. Fifty-eight subjects were tested, of whom 47 were positive for influenza virus by qPCR. Influenza viral RNA was detected in coughs from 38 of these subjects (81%). Thirty-five percent of the influenza RNA was contained in particles>4 µm in aerodynamic diameter, while 23% was in particles 1 to 4 µm and 42% in particles<1 µm. Viable influenza virus was detected in the cough aerosols from 2 of 21 subjects with influenza. These results show that coughing by influenza patients emits aerosol particles containing influenza virus and that much of the viral RNA is contained within particles in the respirable size range. The results support the idea that the airborne route may be a pathway for influenza transmission, especially in the immediate vicinity of an influenza patient. Further research is needed on the viability of airborne influenza viruses and the risk of transmission.


Asunto(s)
Microbiología del Aire , Tos/virología , Gripe Humana/diagnóstico , Orthomyxoviridae/aislamiento & purificación , Adolescente , Adulto , Aerosoles , Femenino , Humanos , Gripe Humana/transmisión , Masculino , Orthomyxoviridae/genética , ARN Viral/genética , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Proteínas de la Matriz Viral/genética , Adulto Joven
10.
Clin Infect Dis ; 50(5): 693-8, 2010 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-20100093

RESUMEN

BACKGROUND: Considerable controversy exists with regard to whether influenza virus and respiratory syncytial virus (RSV) are spread by the inhalation of infectious airborne particles and about the importance of this route, compared with droplet or contact transmission. METHODS: Airborne particles were collected in an urgent care clinic with use of stationary and personal aerosol samplers. The amounts of airborne influenza A, influenza B, and RSV RNA were determined using real-time quantitative polymerase chain reaction. Health care workers and patients participating in the study were tested for influenza. RESULTS: Seventeen percent of the stationary samplers contained influenza A RNA, 1% contained influenza B RNA, and 32% contained RSV RNA. Nineteen percent of the personal samplers contained influenza A RNA, none contained influenza B RNA, and 38% contained RSV RNA. The number of samplers containing influenza RNA correlated well with the number and location of patients with influenza (r= 0.77). Forty-two percent of the influenza A RNA was in particles < or = 4.1 microm in aerodynamic diameter, and 9% of the RSV RNA was in particles < or = 4.1 microm. CONCLUSIONS: Airborne particles containing influenza and RSV RNA were detected throughout a health care facility. The particles were small enough to remain airborne for an extended time and to be inhaled deeply into the respiratory tract. These results support the possibility that influenza and RSV can be transmitted by the airborne route and suggest that further investigation of the potential of these particles to transmit infection is warranted.


Asunto(s)
Microbiología del Aire , Atención Ambulatoria , Virus de la Influenza A/aislamiento & purificación , Virus de la Influenza B/aislamiento & purificación , Virus Sincitial Respiratorio Humano/aislamiento & purificación , Adulto , Niño , Preescolar , Personal de Salud , Hospitales , Humanos , Gripe Humana/diagnóstico , Reacción en Cadena de la Polimerasa/métodos , ARN Viral/aislamiento & purificación , Adulto Joven
11.
Clin Infect Dis ; 48(4): 438-40, 2009 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-19133798

RESUMEN

Size-fractionated aerosol particles were collected in a hospital emergency department to test for airborne influenza virus. Using real-time polymerase chain reaction, we confirmed the presence of airborne influenza virus and found that 53% of detectable influenza virus particles were within the respirable aerosol fraction. Our results provide evidence that influenza virus may spread through the airborne route.


Asunto(s)
Aerosoles , Microbiología del Aire , Servicio de Urgencia en Hospital , Hospitales , Orthomyxoviridae/aislamiento & purificación , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA