Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 134
Filtrar
1.
Arthroplast Today ; 23: 101206, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37745966

RESUMEN

Background: Pelvic skeletal asymmetry can result in rotational differences and morphologic bony prominence variance between the left and right hemipelvis. When selecting bony reference points for modern computed tomography-based robotic total hip arthroplasty planning, it is unclear which bony landmarks are the most reliable and accurate, especially in the presence of significant pelvic asymmetry. Methods: A retrospective study was conducted utilizing a database of computed tomography scans. Multiple bony landmarks in the pelvis and femur were selected for comparison, with the aim of measuring pelvic asymmetry. Specifically, the study measured the average difference in lateral offset between the left and right hemipelvis caused by pelvic asymmetry. Landmarks were also compared to determine the impact of pelvic asymmetry on hip length, femur length, and limb length discrepancies. Furthermore, a scenario was simulated in the software whereby a total hip replacement was inserted, potentially changing the hip length. The impact of pelvic reference point selection on the measurement of this simulated change in hip length was examined. Results: This study population showed widespread pelvic asymmetry. The anatomical landmarks of the opposite side cannot be relied upon for predicting the anatomy of the affected side. The center of rotation axis is more reliable than the inferior obturator foramen axis for hip length discrepancy due to pelvic asymmetry (P < .05). Conclusions: Current computer-assisted surgery THR software reports measurements of global offset and hip length that do not consider pelvic asymmetry. Surgeons are not given confidence ranges to represent the potential impact of asymmetry on the global offset and hip length values. Surgeons following these numbers to guide implant position may incur implant placement error should significant pelvic asymmetry be present in a given patient.

2.
Proc Inst Mech Eng H ; 237(3): 368-374, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36734414

RESUMEN

Standard practice for acetabular component placement in total hip arthroplasty (THA) is to medialise the acetabular component. Bone preservation techniques during primary THA are beneficial for possible future revisions. The goal of this study is to examine the effect of downsizing and minimising medialisation of the acetabular component on bone resection volume. The volume of bone resected during acetabular preparation for different sizes of components was calculated and the volume of bone preserved by downsizing the cup was determined. Minimising medialisation of the acetabular component by 1-3 mm from the true floor was calculated. Absolute values and percentage of bone volume preserved when acetabular components are downsized or less medialised is presented. Downsizing the acetabular component by one size (2 mm) preserves between 2.6 cm3 (size 40 vs 42) and 8.4 cm3 (size 72 vs 74) of bone volume and consistently reduces resected bone volume by at least 35% (range 35.2%-37.5%). Similarly, reducing medialisation of a 56 mm acetabular cup (as an example of a commonly implanted component) by 3 mm reduces bone loss by 5.9 cm3- 44% less bone volume resection. Downsizing and minimising medialisation of the cup in THA substantially preserves bone which may benefit future revision surgeries. Surgeons could consider implanting the smallest acceptable acetabular shell to preserve bone without compromising on head size.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Diseño de Prótesis , Acetábulo/cirugía , Reoperación , Falla de Prótesis , Resultado del Tratamiento
3.
Artículo en Inglés | MEDLINE | ID: mdl-36337282

RESUMEN

Molecular simulations such as molecular dynamics (MD) and Monte Carlo (MC) simulations are powerful tools allowing the prediction of experimental observables in the study of systems such as proteins, membranes, and polymeric materials. The quality of predictions based on molecular simulations depend on the validity of the underlying physical assumptions. physical_validation allows users of molecular simulation programs to perform simple yet powerful tests of physical validity on their systems and setups. It can also be used by molecular simulation package developers to run representative test systems during development, increasing code correctness. The theoretical foundation of the physical validation tests were established by Merz & Shirts (2018), in which the physical_validation package was first mentioned.

4.
PLoS One ; 16(12): e0261623, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34972133

RESUMEN

Since being introduced into clinical practice the AFX family of endografts has undergone labelling updates, design and manufacturing changes to address a Type III failure mode. The published literature on the performance of the current endograft-AFX2 -is limited to small series with limited follow up. The present study reports the largest series of patients implanted with AFX2 for the treatment of abdominal aortic aneurysms. The study was a retrospective, 5 center study of patients receiving an AFX2 endograft from January 2016 until Dec 2020. Electronic case report forms were provided to four of the centers, with one additional site providing relevant outcomes in an independent dataset. Relevant outcomes were reported via Kaplan-Meier analysis and included all-cause mortality, aneurysm-related mortality, post EVAR aortic rupture, open conversion, device related reinterventions and endoleaks. Among a cohort of 460 patients, 405 underwent elective repair of an AAA, 50 were treated for a ruptured AAA, and 5 were aorto-iliac occlusive disease cases. For the elective cohort (mean age 73.7y, 77% male, mean AAA diameter 5.4cm), the peri-operative mortality was 1.7%. Freedom from aneurysm-related mortality was 98.2% at 1,2,3 and 4 years post-operatively, there were no post-operative aortic ruptures, and 2 patients required open conversion. Freedom from Type Ia endoleaks was 99.4% at 1, 2, 3 and 4 years. Freedom from Type IIIa and Type IIIb endoleaks were 100% and 100% (year 1), 100% and 99.6% (year 2), 99.4% and 99.6% (year 3), 99.4% and 99.6% (year 4) respectively. Freedom from all device-related reintervention (including Type II endoleaks) at 4 y was 86.8%. The AFX2 endograft appears to perform to a satisfactory standard in terms of patient centric outcomes in mid-term follow up. The Type Ia and Type III endoleaks rates at 4y appear to be within acceptable limits. Further follow up studies are warranted.


Asunto(s)
Aneurisma de la Aorta Abdominal/fisiopatología , Procedimientos Endovasculares , Injerto Vascular , Anciano , Aneurisma Roto , Endofuga , Diseño de Equipo , Femenino , Estudios de Seguimiento , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Atención Dirigida al Paciente , Periodo Posoperatorio , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
5.
Nature ; 2021 Oct 27.
Artículo en Inglés | MEDLINE | ID: mdl-34707266
6.
ACS Nano ; 15(2): 2994-3003, 2021 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-33513013

RESUMEN

Layered titanium carbide (Ti3C2Tx) MXene is a promising electrode material for use in next-generation electrochemical capacitors. However, the atomic-level information needed to correlate the distribution of intercalated cations with surface redox reactions, has not been investigated in detail. Herein we report on sodium preintercalated MXene with high sodium content (up to 2Na per Ti3C2Tx formula) using a solution of Na-biphenyl radical anion complex (E0 ≈ -2.6 SHE). Multiple sodiation sites and formation of a two-dimensional sodium domain structure at interfaces/surfaces is identified through combined computational simulations with neutron pair distribution function analysis. The induced layer charges and the redox process characterized by the density-functional tight-binding method on a local scale are found to greatly depend on the location of sodium ions. Electrochemical testing of the pre-sodiated MXene as an electrode material in a sodium-ion capacitor shows excellent reversibility and promising performance, indicating the feasibility of chemical preintercalation as an approach to prepare MXene electrodes for ion capacitors.

7.
Nature ; 2020 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-34193987
8.
Sci Rep ; 9(1): 10099, 2019 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-31300694

RESUMEN

Complex surface nanostructures were observed in germanium and silicon samples exposed to low energy (24 or 36 eV ion kinetic energy) helium plasma. Pyramidal growth is observed in germanium across the temperature range studied (185 °C to 336 °C), while significant modification in silicon was only observed at 630 °C. Nano-wire growth was observed in both germanium and silicon, and appears to be linked to the strength of the electric field, which in turn determines the implantation energy of the helium ions. Nanostructure formation is proposed to be driven by surface adatom migration which is strongly influenced by an Ehrlich-Schwoebel-type surface instability. The role of helium in this model is to drive germanium interstitial formation by ejecting germanium atoms from lattice sites, leading to germanium interstitial diffusion towards the sample surface and subsequent adatom and surface nanostructure formation.

9.
J Patient Rep Outcomes ; 3(1): 29, 2019 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-31098754

RESUMEN

BACKGROUND: To evaluate the psychometric properties of three new condition-specific questionnaires designed to assess outcomes amongst patients under pre-operative surveillance for a small abdominal aortic aneurysm (AAA) or who have undergone aneurysm repair. These tools are the Aneurysm-Dependent Quality of Life measure (AneurysmDQoL), the Aneurysm Symptom Rating Questionnaire (AneurysmSRQ) and the Aneurysm Treatment Satisfaction Questionnaire (AneurysmTSQ). RESULTS: The questionnaires were sent to 297 patients with abdominal aortic aneurysm (AAA) or who had undergone AAA repair (using open or endovascular technique) sampled from five UK NHS Trusts. Exploratory Factor Analysis was used to examine factor structure together with reliability analysis. A subset of 65 patients completed the questionnaires a second time four months later. One hundred and ninety-seven patients (178 men; 18 women) provided data for analysis (69% response rate): mean age was 75 years (range 60-95). Nineteen were under pre-operative surveillance for AAA and 178 had undergone AAA repair (70 open repair; 104 endovascular repair; 4 uncertain). Exploratory Factor Analysis of the AneurysmDQoL and the AneurysmTSQ each demonstrated a one-factor structure. The AneurysmSRQ demonstrated a six-factor structure (emotional, weight loss, lower limb, cognitive, general malaise and gastrointestinal symptoms) and a one-factor composite symptom scale. All scales have clean factor structures: item loadings above 0.40, no cross-loadings, and no factors with fewer than three items. Internal consistency reliability was excellent (α = 0.869-0.959) and test-retest reliability good (Intraclass correlation coefficient = 0.70-0.88). CONCLUSIONS: The three new questionnaires have a clear structure and strong reliability and are now ready for use in clinical trials and routine practice, which will allow evaluation of responsiveness to change.

10.
J Vasc Surg ; 69(6): 1776-1785.e2, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30583890

RESUMEN

OBJECTIVE: Endovascular aneurysm repair (EVAR) has increasingly been used as the primary treatment approach for abdominal aortic aneurysm (AAA). This study examined the hypothesis that EVAR leads to an increased risk of abdominal cancer within the radiation field compared with open AAA repair. METHODS: The nationwide English Hospital Episode Statistics database was used to identify all patients older than 50 years who received an AAA repair in 2005 to 2013. EVAR and open AAA repair groups were compared for the incidence of postoperative cancer using inverse probability weights and G-computation formula to adjust for selection bias and confounding. RESULTS: Among 14,150 patients who underwent EVAR and 24,645 patients who underwent open AAA repair, follow-up was up to 7 years. EVAR was associated with an increased risk of postoperative abdominal cancer (hazard ratio [HR], 1.14; 95% confidence interval [CI], 1.03-1.27) and all cancers (HR, 1.09; 95% CI, 1.02-1.17). However, there was no difference between the groups in the risk of lung cancer (HR, 1.04; 95% CI, 0.92-1.18) or obesity-related nonabdominal cancer (HR, 1.12; 95% CI, 0.69-1.83). Within the EVAR group, use of computed tomography surveillance was not associated with any increased risk of abdominal cancer (HR, 0.94; 95% CI, 0.71-1.23) or all cancers (HR, 0.97; 95% CI, 0.81-1.17). CONCLUSIONS: This study suggests an increased risk of abdominal cancer after EVAR compared with open AAA repair. The differential cancer risk should be further explored in alternative national populations, and radiation exposure during EVAR should be measured as a quality metric in the assessment of EVAR centers.


Asunto(s)
Neoplasias Abdominales/epidemiología , Aneurisma de la Aorta Abdominal/cirugía , Aortografía/efectos adversos , Implantación de Prótesis Vascular/efectos adversos , Angiografía por Tomografía Computarizada/efectos adversos , Procedimientos Endovasculares/efectos adversos , Neoplasias Inducidas por Radiación/epidemiología , Radiografía Intervencional/efectos adversos , Neoplasias Abdominales/diagnóstico , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/epidemiología , Bases de Datos Factuales , Inglaterra/epidemiología , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Neoplasias Inducidas por Radiación/diagnóstico , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
11.
Nature ; 559(7712): 146, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29970911
13.
Eur J Vasc Endovasc Surg ; 55(4): 492-502, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29307756

RESUMEN

OBJECTIVE/BACKGROUND: Increasingly, reports show that compliance rates with endovascular aneurysm repair (EVAR) surveillance are often suboptimal. The aim of this study was to determine the safety implications of non-compliance with surveillance. METHODS: The study was carried out according to the Preferred Items for Reporting of Systematic Reviews and Meta-Analyses (PRISMA) guidelines. An electronic search was undertaken by two independent authors using Embase, MEDLINE, Cochrane, and Web of Science databases from 1990 to July 2017. Only studies that analysed infrarenal EVAR and had a definition of non-compliance described as weeks or months without imaging surveillance were analysed. Meta-analysis was carried out using the random-effects model and restricted maximum likelihood estimation. RESULTS: Thirteen articles (40,730 patients) were eligible for systematic review; of these, seven studies (14,311 patients) were appropriate for comparative meta-analyses of mortality rates. Three studies (8316 patients) were eligible for the comparative meta-analyses of re-intervention rates after EVAR and four studies (12,995 patients) eligible for meta-analysis for abdominal aortic aneurysm related mortality (ARM). The estimated average non-compliance rate was 42.0% (95% confidence interval [CI] 28-56%). Although there is some evidence that non-compliant patients have better survival rates, there was no statistically significant difference in all cause mortality rates (year 1: odds ratio [OR] 5.77, 95% CI 0.74-45.14; year 3: OR 2.28, 95% CI 0.92-5.66; year 5: OR 1.81, 95% CI 0.88-3.74) and ARM (OR 1.47, 95% CI 0.99-2.19) between compliant and non-compliant patients in the first 5 years after EVAR. The re-intervention rate was statistically significantly higher in compliant patients from 3 to 5 years after EVAR (year 1: OR 6.36, 95% CI 0.23-172.73; year 3: OR 3.94, 85% CI 1.46-10.69; year 5: OR 5.34, 95% CI 1.87-15.29). CONCLUSION: This systematic review and meta-analysis suggests that patients compliant with EVAR surveillance programmes may have an increased re-intervention rate but do not appear to have better survival rates than non-compliant patients.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Cooperación del Paciente , Complicaciones Posoperatorias/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/mortalidad , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Humanos , Estimación de Kaplan-Meier , Oportunidad Relativa , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/terapia , Valor Predictivo de las Pruebas , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
14.
J Endovasc Ther ; 24(6): 764-772, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28895447

RESUMEN

PURPOSE: To report the results of the ASCEND Registry of cases involving endovascular aneurysm sealing (EVAS) in combination with chimney grafts (chEVAS) for the treatment of para- and juxtarenal aortic aneurysms (AAA). METHODS: A retrospective, multicenter registry established in 8 vascular centers between 2013 and 2016 recorded the treatment results and follow-up of chEVAS procedures for nonruptured AAAs; data were analyzed using standardized outcome measures. In the observation period, 154 patients (mean age 72.3±7.7 years; 124 men) underwent elective treatment for de novo juxtarenal and pararenal aneurysms and formed the study group. RESULTS: Sixty-two (40.3%) of the cohort were treated using a single parallel graft, 54 (35.1%) with double chimneys, 27 (17.5%) with triple chimneys, and 11 (7.1%) with 4 chimneys. The 30-day mortality was 2.8%, and there were 4 perioperative strokes (1 fatal). At 1 year, the freedom from all-cause mortality was 89.8% and the freedom from aneurysm-related mortality was 94.3%. There were 3 endoleaks within 90 days of the procedure, one type Ia and 2 type Ib. The freedom from type Ia endoleaks was 95.7% at 1 year. There were no types II or III endoleaks in this series; the freedom from all endoleaks was 94.2% at 1 year. Freedom from reintervention at 1 year was 89.2%. Target vessel patency rates at 1 year were 97.7%, 99.3%, 100%, and 100% for the left renal, right renal, superior mesenteric artery, and celiac axis stents, respectively. CONCLUSION: The ASCEND Registry supports a proof of concept for the use of polymer technology and EVAS with parallel grafts in managing patients with complex aortic disease. The future role of chEVAS will be defined by studies that assess mid- to long-term durability.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/mortalidad , Aneurisma de la Aorta Abdominal/fisiopatología , Aortografía/métodos , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Angiografía por Tomografía Computarizada , Endofuga/etiología , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Europa (Continente) , Femenino , Humanos , Masculino , Nueva Zelanda , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular
15.
Vasc Endovascular Surg ; 51(6): 417-428, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28656809

RESUMEN

BACKGROUND: Current surveillance protocols after endovascular aneurysm repair (EVAR) are ineffective and costly. Stratifying surveillance by individual risk of reintervention requires an understanding of the factors involved in developing post-EVAR complications. This systematic review assessed risk factors for reintervention after EVAR and proposals for stratified surveillance. METHODS: A systematic search according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines was performed using EMBASE and MEDLINE databases to identify studies reporting on risk factors predicting reintervention after EVAR and proposals for stratified surveillance. RESULTS: Twenty-nine studies reporting on 39 898 patients met the primary inclusion criteria for reporting predictors of reintervention or aortic complications with or without suggestions for stratified surveillance. Five secondary studies described external validation of risk scores for reintervention or aortic complications. There was great heterogeneity in reporting risk factors identified at the pre-EVAR, intraoperative, and post-EVAR stages of treatment, although large preoperative abdominal aortic aneurysm diameter was the most commonly observed risk factor for reintervention after EVAR. CONCLUSION: Existing data on predictors of post-EVAR complications are generally of poor quality and largely derived from retrospective studies. Few studies describing suggestions for stratified surveillance have been subjected to external validation. There is a need to refine risk prediction for EVAR failure and to conduct prospective comparative studies of personalized surveillance with standard practice.


Asunto(s)
Aneurisma de la Aorta/cirugía , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Complicaciones Posoperatorias/terapia , Aneurisma de la Aorta/diagnóstico por imagen , Técnicas de Apoyo para la Decisión , Humanos , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/etiología , Valor Predictivo de las Pruebas , Retratamiento , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
16.
Respir Physiol Neurobiol ; 242: 40-44, 2017 08.
Artículo en Inglés | MEDLINE | ID: mdl-28336390

RESUMEN

Recent evidence suggests that surface electromyography of the parasternal intercostals (EMGpara) can be a non-invasive alternative to diaphragmatic EMG (EMGdi) for estimating neural respiratory drive (NRD) during cardiopulmonary exercise testing (CPET). The purpose of this study was to determine if non-respiratory muscles influence EMGpara by having subjects place their hands on (Hon) and off (Hoff) the handlebars during cycling-based CPET. Ten healthy adults performed an incremental cycling test until volitional exhaustion. Participants were instrumented with an esophageal electrode catheter to measure EMGdi, and surface electrodes on the 2nd intercostal space to measure EMGpara. Subjects alternated between 30s of Hon and 30s Hoff during each exercise stage. There were no differences in EMGdi across all exercise intensities. However, EMGpara was significantly greater during the Hon vs. Hoff condition at all exercise intensities (p<0.05). These results suggest that EMGpara may not be an appropriate surrogate of NRD during cycle exercise testing due to co-activation of adjacent skeletal muscles.


Asunto(s)
Ciclismo/fisiología , Diafragma/fisiopatología , Disnea/fisiopatología , Músculos Intercostales/fisiopatología , Respiración , Electromiografía , Prueba de Esfuerzo , Tolerancia al Ejercicio/fisiología , Femenino , Humanos , Masculino , Adulto Joven
17.
J Endovasc Ther ; 23(5): 685-92, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-27555430

RESUMEN

PURPOSE: To report the early and 12-month results of a global registry of patients treated with endovascular aneurysm sealing (EVAS) for abdominal aortic aneurysms (AAAs). METHODS: The EVAS FORWARD Global Registry was a postmarket, multicenter, open-label, single-arm registry that enrolled 277 patients (mean age 75 years; 228 men) treated with the Nellix EVAS system for nonruptured AAAs at 18 sites over a 1-year period. The cohort had challenging aortic anatomy, with 17% having a proximal aortic neck length <10 mm, 8% a neck angulation >60°, and 20% an iliac diameter >25 mm. Baseline and follow-up computed tomography images were assessed by an independent core laboratory, and major adverse events were reviewed by an independent safety committee. RESULTS: Three patients died within 30 days of the procedure (none device-related). There were 13 endoleaks recorded in this time frame: 8 type Ia, 1 type Ib, and 5 type II. Root cause analysis demonstrated that the majority of type Ia endoleaks were due to technical error (low device placement and underfilling of the endobags). Between 30 days and 1 year, there were 4 new type Ia endoleaks; all were treated. There was also 1 type III endoleak between a Nellix device and a distal extension limb. At 1 year, the persistent endoleak rate was 0.7% (1 type Ia and 1 type II). The Kaplan-Meier estimates of freedom from types I and II endoleak at 12-month follow-up were 96% and 98%, respectively. The estimate of freedom from open conversion (n=7) was 98% at 12 months and the rate of freedom from any reintervention was 92%. The need for secondary intervention was associated with aortic morphology; for patients meeting the requirements of the instructions for use (IFU), the freedom from reintervention at 12 months was 98% compared with 86% when the implant was outside the IFU (p=0.009). At 1 year, the estimates of freedom from aortic-related and all-cause mortality were 98% and 95%, respectively. CONCLUSION: The EVAS FORWARD Global Registry documents the 12-month outcome of EVAS in an unselected group of patients with challenging aortic morphology. The results at present appear acceptable with regard to perioperative outcomes and complications. The type II endoleak rate is low. The place of EVAS in the armamentarium of techniques to treat AAAs will be defined by durability data in the longer term.


Asunto(s)
Aneurisma de la Aorta Abdominal/terapia , Implantación de Prótesis Vascular , Prótesis Vascular , Procedimientos Endovasculares , Anciano , Aortografía , Femenino , Humanos , Masculino , Diseño de Prótesis , Sistema de Registros , Factores de Riesgo , Stents , Factores de Tiempo , Resultado del Tratamiento
19.
Nat Rev Dis Primers ; 2: 16053, 2016 07 21.
Artículo en Inglés | MEDLINE | ID: mdl-27440162

RESUMEN

Aortic dissection is a life-threatening condition caused by a tear in the intimal layer of the aorta or bleeding within the aortic wall, resulting in the separation (dissection) of the layers of the aortic wall. Aortic dissection is most common in those 65-75 years of age, with an incidence of 35 cases per 100,000 people per year in this population. Other risk factors include hypertension, dyslipidaemia and genetic disorders that involve the connective tissue, such as Marfan syndrome. Swift diagnostic confirmation and adequate treatment are crucial in managing affected patients. Contemporary management is multidisciplinary and includes serial non-invasive imaging, biomarker testing and genetic risk profiling for aortopathy. The choice of approach for repairing or replacing the damaged region of the aorta depends on the severity and the location of the dissection and the risks of complication from surgery. Open surgical repair is most commonly used for dissections involving the ascending aorta and the aortic arch, whereas minimally invasive endovascular intervention is appropriate for descending aorta dissections that are complicated by rupture, malperfusion, ongoing pain, hypotension or imaging features of high risk. Recent advances in the understanding of the underlying pathophysiology of aortic dissection have led to more patients being considered at substantial risk of complications and, therefore, in need of endovascular intervention rather than only medical or surgical intervention.


Asunto(s)
Disección Aórtica/diagnóstico , Disección Aórtica/fisiopatología , Disección Aórtica/cirugía , Mortalidad , Aorta/patología , Aorta/fisiopatología , Biomarcadores/análisis , Procedimientos Quirúrgicos Cardíacos , Dislipidemias/complicaciones , Humanos , Hipertensión/complicaciones , Imagen por Resonancia Magnética/métodos , Síndrome de Marfan/complicaciones , Factores de Riesgo , Tomografía Computarizada por Rayos X/métodos
20.
J Vasc Surg ; 63(6): 1428-1433.e1, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27005591

RESUMEN

BACKGROUND: Identifying patients at risk for aneurysm rupture and sac expansion after open and endovascular abdominal aortic aneurysm (AAA) repair (EVAR) may help to attenuate this risk by intensifying follow-up and early detection of problems. The goal of this study was to validate the St George's Vascular Institute (SGVI) score to identify patients at risk for a secondary intervention after elective aneurysm repair. METHODS: A post hoc on-treatment analysis of a randomized trial comparing open AAA repair and EVAR was performed. In this multicenter trial, 351 patients were randomly assigned to undergo open AAA repair or EVAR. Information on survival and reinterventions was available for all patients at 5 years postoperatively, for 79% at 6 years, and for 53% at 7 years. Open repair was completed in 173 patients and EVAR in 171, based on an on-treatment analysis. Because 17 patients had incomplete anatomic data, 327 patients (157 open repair and 170 EVAR) were available for analysis. During 6 years of follow-up, 78 patients underwent at least one reintervention. The SGVI score, which is calculated from preoperative AAA morphology using aneurysm and iliac diameter, predictively dichotomized patients into groups at high-risk or low-risk for a secondary intervention. The observed freedom from reintervention was compared between groups at predicted high-risk and predicted low-risk. RESULTS: The 20 patients in the high-risk group were indeed at higher risk for a secondary intervention compared with the 307 patients predicted to be at low risk (hazard ratio [HR], 3.82; 95% confidence interval [CI], 2.05-7.11; P < .001). Discrimination between high-risk and low-risk groups was valid for EVAR (HR, 4.06; 95% CI, 1.93-8.51; P < .001) and for open repair (HR, 3.41; 95% CI, 1.02-11.4; P = .033). CONCLUSIONS: The SGVI score appears to be a useful tool to predict reintervention risk in patients after open repair and EVAR.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/efectos adversos , Técnicas de Apoyo para la Decisión , Procedimientos Endovasculares/efectos adversos , Complicaciones Posoperatorias/cirugía , Reoperación , Anciano , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/mortalidad , Bélgica , Implantación de Prótesis Vascular/mortalidad , Supervivencia sin Enfermedad , Procedimientos Endovasculares/mortalidad , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Países Bajos , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/mortalidad , Valor Predictivo de las Pruebas , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...