1.
J Biophotonics ; 16(2): e202200141, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36062395

RESUMEN

We present an endoscopic probe that combines three distinct optical fibre technologies including: A high-resolution imaging fibre for optical endomicroscopy, a multimode fibre for time-resolved fluorescence spectroscopy, and a hollow-core fibre with multimode signal collection cores for Raman spectroscopy. The three fibers are all enclosed within a 1.2 mm diameter clinical grade catheter with a 1.4 mm end cap. To demonstrate the probe's flexibility we provide data acquired with it in loops of radii down to 2 cm. We then use the probe in an anatomically accurate model of adult human airways, showing that it can be navigated to any part of the distal lung using a commercial bronchoscope. Finally, we present data acquired from fresh ex vivo human lung tissue. Our experiments show that this minimally invasive probe can deliver real-time optical biopsies from within the distal lung - simultaneously acquiring co-located high-resolution endomicroscopy and biochemical spectra.


Asunto(s)
Endoscopía , Espectrometría Raman , Humanos , Espectrometría Raman/métodos , Espectrometría de Fluorescencia , Diagnóstico por Imagen , Biopsia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA