Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Nat Commun ; 14(1): 7046, 2023 Nov 10.
Artículo en Inglés | MEDLINE | ID: mdl-37949859

RESUMEN

Large laser facilities have recently enabled material characterization at the pressures of Earth and Super-Earth cores. However, the temperature of the compressed materials has been largely unknown, or solely relied on models and simulations, due to lack of diagnostics under these challenging conditions. Here, we report on temperature, density, pressure, and local structure of copper determined from extended x-ray absorption fine structure and velocimetry up to 1 Terapascal. These results nearly double the highest pressure at which extended x-ray absorption fine structure has been reported in any material. In this work, the copper temperature is unexpectedly found to be much higher than predicted when adjacent to diamond layer(s), demonstrating the important influence of the sample environment on the thermal state of materials; this effect may introduce additional temperature uncertainties in some previous experiments using diamond and provides new guidance for future experimental design.

2.
Rev Sci Instrum ; 92(5): 053102, 2021 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-34243250

RESUMEN

We report the development of a high-resolution spectrometer for extended x-ray absorption fine structure (EXAFS) studies of materials under extreme conditions. A curved crystal and detector in the spectrometer are replaceable such that a single body is employed to perform EXAFS measurements at different x-ray energy intervals of interest. Two configurations have been implemented using toroidal crystals with Ge 311 reflection set to provide EXAFS at the Cu K-edge (energy range 8.9-9.8 keV) and Ge 400 reflection set to provide EXAFS at the Ta L3-edge (9.8-10.7 keV). Key performance characteristics of the spectrometer were found to be consistent with design parameters. The data generated at the National Ignition Facility have shown an ≃3 eV spectral resolution for the Cu K-edge configuration and ≃6 eV for the Ta L3-edge configuration.

4.
Rev Sci Instrum ; 90(1): 013506, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30709229

RESUMEN

The sensitivity of Fuji SR and MS image plates (IPs) used in x-ray spectrometers on OMEGA and the National Ignition Facility has been measured using two techniques. A set of radioisotopes has been used to constrain image-plate sensitivity between 6 and 60 keV, while a Manson source has been used to expose image plates to x rays at energies between 1.5 and 8 keV. These data have shown variation in sensitivity on the order of 5% for a given IP type and scanner settings. The radioisotope technique has also been used to assess IP fading properties for MS-type plates over long times. IP sensitivity as a function of scanner settings and pixel size has been systematically examined, showing variations of up to a factor of 2 depending on the IP type. Cross-calibration of IP scanners at different facilities is necessary to produce a consistent absolute sensitivity curve spanning the energy range of 2-60 keV.

5.
Rev Sci Instrum ; 90(12): 125113, 2019 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-31893795

RESUMEN

The use of x-ray diffraction (XRD) measurements in laser-driven dynamic compression experiments at high-power laser facilities is becoming increasingly common. Diffraction allows one to probe in situ the transformations occurring at the atomic level at extreme conditions of pressure, temperature, and time scale. In these measurements, the x-ray source is generated by irradiation of a solid foil. Under certain laser drive conditions, quasimonochromatic He-α radiation is generated. Careful analysis of the x-ray source plasma spectra reveals that this radiation is not a single line emission and that monochromaticity is highly dependent on the laser irradiance. In this work, we analyze how the spectra emitted by laser-irradiated copper, germanium, and iron foils at the Omega Laser vary depending on different laser drive conditions and discuss the implications for XRD experiments.

6.
Rev Sci Instrum ; 89(10): 10F119, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30399669

RESUMEN

At large laser faculties, such as OMEGA and the National Ignition Facility (NIF), x-ray spectrometers are provided by the facility to diagnose plasma conditions or monitor backlighters. Often the calibration of these spectrometers is unknown or out of date. As a remedy to this situation, we present a simple ray trace method to calibrate flat crystal spectrometers using only basic information regarding the optical design of the spectrometer. This model is then used to output photometric throughput estimates, dispersion, solid angle, and spectral resolution estimates. This model is applied to the mono angle crystal spectrometer and Super Snout I at the NIF and the X-Ray Spectrometer at the OMEGA laser facility.

7.
Rev Sci Instrum ; 89(10): 10F125, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30399848

RESUMEN

A high resolution, Diagnostic Instrument Manipulator (DIM)-based x-ray Bragg crystal spectrometer has been calibrated for and deployed at the National Ignition Facility (NIF) to diagnose plasma conditions in ignition capsules near stagnation times. The spectrometer has two conical crystals in the Hall geometry focusing rays from the Kr Heα, Lyα, and Heß complexes onto a streak camera, with the physics objectives of measuring time-resolved electron density and temperature through observing Stark broadening and the relative intensities of dielectronic satellites. A third von Hámos crystal that time-integrates the Kr Heα, Heß and intervening energy range provides in situ calibration for the streak camera signals. The spectrometer has been absolutely calibrated using a microfocus x-ray source, an array of CCD and single-photon-counting detectors, and multiple K- and L-absorption edge filters at the Princeton Plasma Physics Laboratory (PPPL) x-ray laboratory. Measurements of the integrated reflectivity, energy range, and energy resolution for each crystal are discussed. These calibration data provide absolute x-ray signal levels for NIF measurements, enabling precise filter selection and comparisons to simulations.

8.
Rev Sci Instrum ; 89(10): 10F114, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30399955

RESUMEN

Extended X-ray absorption fine structure (EXAFS) spectroscopy is a powerful tool for in situ characterization of matter in the high energy density regime. An EXAFS platform is currently being developed on the National Ignition Facility. Development of a suitable X-ray backlighter involves minimizing the temporal duration and source size while maximizing spectral smoothness and brightness. One approach involves imploding a spherical shell, which generates a high-flux X-ray flash at stagnation. We present results from a series of experiments comparing the X-ray source properties produced by imploded empty and Ar-filled capsules.

9.
Phys Rev Lett ; 121(9): 095002, 2018 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-30230893

RESUMEN

We report on the first multilocation electron temperature (T_{e}) and flow measurements in an ignition hohlraum at the National Ignition Facility using the novel technique of mid-Z spectroscopic tracer "dots." The measurements define a low resolution "map" of hohlraum plasma conditions and provide a basis for the first multilocation tests of particle and energy transport physics in a laser-driven x-ray cavity. The data set is consistent with classical heat flow near the capsule but reduced heat flow near the laser entrance hole. We evaluate the role of kinetic effects, self-generated magnetic fields, and instabilities in causing spatially dependent heat transport in the hohlraum.

10.
Rev Sci Instrum ; 88(8): 083907, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28863696

RESUMEN

Extended X-ray absorption Fine Structure (EXAFS) measurements require a bright, spectrally smooth, and broad-band x-ray source. In a laser facility, such an x-ray source can be generated by a laser-driven capsule implosion. In order to optimize the x-ray emission, different capsule types and laser irradiations have been tested at the National Ignition Facility (NIF). A crystal spectrometer is used to disperse the x-rays and high efficiency image plate detectors are used to measure the absorption spectra in transmission geometry. EXAFS measurements at the K-edge of iron at ambient conditions have been obtained for the first time on the NIF laser, and the requirements for optimization have been established.

11.
Rev Sci Instrum ; 87(11): 11E344, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27910374

RESUMEN

A high resolution (E/ΔE = 1200-1800) Bragg crystal x-ray spectrometer is being developed to measure plasma parameters in National Ignition Facility experiments. The instrument will be a diagnostic instrument manipulator positioned cassette designed mainly to infer electron density in compressed capsules from Stark broadening of the helium-ß (1s2-1s3p) lines of krypton and electron temperature from the relative intensities of dielectronic satellites. Two conically shaped crystals will diffract and focus (1) the Kr Heß complex and (2) the Heα (1s2-1s2p) and Lyα (1s-2p) complexes onto a streak camera photocathode for time resolved measurement, and a third cylindrical or conical crystal will focus the full Heα to Heß spectral range onto an image plate to provide a time integrated calibration spectrum. Calculations of source x-ray intensity, spectrometer throughput, and spectral resolution are presented. Details of the conical-crystal focusing properties as well as the status of the instrumental design are also presented.

12.
Phys Rev Lett ; 112(23): 233003, 2014 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-24972204

RESUMEN

High-resolution spectroscopy of the 2s(1/2)-2p(1/2) transition in the extreme ultraviolet region is shown to resolve the level splitting induced by the nuclear magnetic field of both the 2s(1/2) and the 2p(1/2) levels in lithiumlike (141)Pr(56+) and of the 2s(1/2)2p(1/2) (3)P(1) level in berylliumlike (141)Pr(55+). The (141)Pr ions are an ideal test of this measurement approach because their energy levels are known well from first principles and are unaffected by small energy contributions from QED and nuclear magnetization effects. The accuracy attained in the measured 196.5 ± 1.2 meV 2s(1/2) splitting is more than an order of magnitude better than that achieved before using crystal spectroscopy of the 2s(1/2)-2p(3/2) x-ray transition and at the level needed to implement a proposed scheme for disentangling the contributions from QED and nuclear magnetization effects in higher-Z ions, such as (209)Bi.

13.
Phys Rev Lett ; 111(11): 114803, 2013 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-24074095

RESUMEN

Thomson backscattering of intense laser pulses from relativistic electrons not only allows for the generation of bright x-ray pulses but also for the investigation of the complex particle dynamics at the interaction point. For this purpose a complete spectral characterization of a Thomson source powered by a compact linear electron accelerator is performed with unprecedented angular and energy resolution. A rigorous statistical analysis comparing experimental data to 3D simulations enables, e.g., the extraction of the angular distribution of electrons with 1.5% accuracy and, in total, provides predictive capability for the future high brightness hard x-ray source PHOENIX (photon electron collider for narrow bandwidth intense x rays) and potential gamma-ray sources.

14.
Phys Rev Lett ; 110(21): 213201, 2013 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-23745869

RESUMEN

The K shell excitation of H-like uranium (U(91+)) in relativistic collisions with different gaseous targets has been studied at the experimental storage ring at GSI Darmstadt. By performing measurements with different targets as well as with different collision energies, we were able to observe for the first time the effect of electron-impact excitation (EIE) process in the heaviest hydrogenlike ion. The large fine-structure splitting in H-like uranium allowed us to unambiguously resolve excitation into different L shell levels. State-of-the-art calculations performed within the relativistic framework which include excitation mechanisms due to both protons (nucleus) and electrons are in good agreement with the experimental findings. Moreover, our experimental data clearly demonstrate the importance of including the generalized Breit interaction in the treatment of the EIE process.

15.
Phys Rev Lett ; 108(26): 264801, 2012 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-23004992

RESUMEN

We report on a study of the polarization transfer between transversely polarized incident electrons and the emitted x rays for electron-atom bremsstrahlung. By means of Compton polarimetry we performed for the first time an energy-differential measurement of the complete properties of bremsstrahlung emission related to linear polarization, i.e., the degree of linear polarization as well as the orientation of the polarization axis. For the high-energy end of the bremsstrahlung continuum the experimental results for both observables show a high sensitivity on the initial electron spin polarization and prove that the polarization orientation is virtually independent of the photon energy.

16.
Phys Rev Lett ; 109(6): 064802, 2012 Aug 10.
Artículo en Inglés | MEDLINE | ID: mdl-23006273

RESUMEN

X-ray spectroscopy is used to obtain single-shot information on electron beam emittance in a low-energy-spread 0.5 GeV-class laser-plasma accelerator. Measurements of betatron radiation from 2 to 20 keV used a CCD and single-photon counting techniques. By matching x-ray spectra to betatron radiation models, the electron bunch radius inside the plasma is estimated to be ~0.1 µm. Combining this with simultaneous electron spectra, normalized transverse emittance is estimated to be as low as 0.1 mm mrad, consistent with three-dimensional particle-in-cell simulations. Correlations of the bunch radius with electron beam parameters are presented.

17.
Rev Sci Instrum ; 81(10): 10E325, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21034023

RESUMEN

X-ray betatron radiation is produced by oscillations of electrons in the intense focusing field of a laser-plasma accelerator. These hard x-rays show promise for use in femtosecond-scale time-resolved radiography of ultrafast processes. However, the spectral characteristics of betatron radiation have only been inferred from filter pack measurements. In order to achieve higher resolution spectral information about the betatron emission, we used an x-ray charge-coupled device to record the spectrum of betatron radiation, with a full width at half maximum resolution of 225 eV. In addition, we have recorded simultaneous electron and x-ray spectra along with x-ray images that allow for a determination of the betatron emission source size, as well as differences in the x-ray spectra as a function of the energy spectrum of accelerated electrons.

18.
Rev Sci Instrum ; 79(10): 10E309, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19044471

RESUMEN

The Electron Beam Ion Trap (EBIT) facility at the Lawrence Livermore National Laboratory is being used to absolutely calibrate the transmission efficiency of x-ray filters employed by diodes and spectrometers used to diagnose laser-produced plasmas. EBIT emits strong, discrete monoenergetic lines at appropriately chosen x-ray energies. X rays are detected using the high resolution EBIT Calorimeter Spectrometer (ECS), developed for LLNL at the NASA/Goddard Space Flight Center. X-ray filter transmission efficiency is determined by dividing the x-ray counts detected when the filter is in the line of sight by those detected when out of the line of sight. Verification of filter thickness can be completed in only a few hours, and absolute efficiencies can be calibrated in a single day over a broad range from about 0.1 to 15 keV. The EBIT calibration lab has been used to field diagnostics (e.g., the OZSPEC instrument) with fully calibrated x-ray filters at the OMEGA laser. Extensions to use the capability for calibrating filter transmission for the DANTE instrument on the National Ignition Facility are discussed.

19.
Phys Rev E Stat Nonlin Soft Matter Phys ; 77(6 Pt 2): 066406, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18643382

RESUMEN

Measurements of the L -shell emission of highly charged gold ions were made under controlled laboratory conditions using the SuperEBIT electron beam ion trap, allowing detailed spectral observations of lines from Fe-like Au53+ through Ne-like Au69+ . Using atomic data from the Flexible Atomic Code, we have identified strong 3d_{52}-->2p_{32} emission features that can be used to diagnose the charge state distribution in high energy density plasmas, such as those found in the laser entrance hole of hot hohlraum radiation sources. We provide collisional-radiative calculations of the average ion charge Z as a function of temperature and density, which can be used to relate charge state distributions inferred from 3d_{52}-->2p_{32} emission features to plasma conditions, and investigate the effects of plasma density on calculated L -shell Au emission spectra.

20.
Phys Rev Lett ; 95(23): 233003, 2005 Dec 02.
Artículo en Inglés | MEDLINE | ID: mdl-16384304

RESUMEN

Using the SuperEBIT electron beam ion trap, we have measured the 2s(1/2)-2p(1/2) transitions in U88+ and U89+. The measured value of 280.645 +/- 0.015 eV for Li-like U89+ improves the available precision by nearly an order of magnitude and establishes a new benchmark for testing the total QED contribution to the transition energy within a fractional accuracy of 3.6 x 10(-4). We infer a value for the 2s two-loop Lamb shift in U89+ of -0.23 eV, from which we estimate a value of -1.27 eV for the 1s two-loop Lamb shift in U91+.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...