Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
PLoS One ; 19(4): e0300098, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38625996

RESUMEN

The structural morphology of coronary stents and the local hemodynamic environment following stent deployment in coronary arteries are crucial determinants of procedural success and subsequent clinical outcomes. High-resolution intracoronary imaging has the potential to facilitate geometrically accurate three-dimensional (3D) reconstruction of coronary stents. This work presents an innovative algorithm for the 3D reconstruction of coronary artery stents, leveraging intravascular ultrasound (IVUS) and angiography. The accuracy and reproducibility of our method were tested in stented patient-specific silicone models, with micro-computed tomography serving as a reference standard. We also evaluated the clinical feasibility and ability to perform computational fluid dynamics (CFD) studies in a clinically stented coronary bifurcation. Our experimental and clinical studies demonstrated that our proposed algorithm could reproduce the complex 3D stent configuration with a high degree of precision and reproducibility. Moreover, the algorithm was proved clinically feasible in cases with stents deployed in a diseased coronary artery bifurcation, enabling CFD studies to assess the hemodynamic environment. In combination with patient-specific CFD studies, our method can be applied to stenting optimization, training in stenting techniques, and advancements in stent research and development.


Asunto(s)
Enfermedad de la Arteria Coronaria , Vasos Coronarios , Humanos , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Vasos Coronarios/anatomía & histología , Microtomografía por Rayos X , Imagenología Tridimensional , Estudios de Factibilidad , Reproducibilidad de los Resultados , Stents , Ultrasonografía Intervencional , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía
3.
J Med Imaging (Bellingham) ; 11(1): 014004, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38173655

RESUMEN

Purpose: Optical coherence tomography has emerged as an important intracoronary imaging technique for coronary artery disease diagnosis as it produces high-resolution cross-sectional images of luminal and plaque morphology. Precise and fast lumen segmentation is essential for efficient OCT morphometric analysis. However, due to the presence of various image artifacts, including side branches, luminal blood artifacts, and complicated lesions, this remains a challenging task. Approach: Our research study proposes a rapid automatic segmentation method that utilizes nonuniform rational B-spline to connect limited pixel points and identify the edges of the OCT lumen. The proposed method suppresses image noise and accurately extracts the lumen border with a high correlation to ground truth images based on the area, minimal diameter, and maximal diameter. Results: We evaluated the method using 3300 OCT frames from 10 patients and found that it achieved favorable results. The average time taken for automatic segmentation by the proposed method is 0.17 s per frame. Additionally, the proposed method includes seamless vessel reconstruction following the lumen segmentation. Conclusions: The developed automated system provides an accurate, efficient, robust, and user-friendly platform for coronary lumen segmentation and reconstruction, which can pave the way for improved assessment of the coronary artery lumen morphology.

4.
Sci Rep ; 13(1): 13031, 2023 08 10.
Artículo en Inglés | MEDLINE | ID: mdl-37563354

RESUMEN

Coronary bifurcation lesions represent a challenging anatomical subset, and the understanding of their 3D anatomy and plaque composition appears to play a key role in devising the optimal stenting strategy. This study proposes a new approach for the 3D reconstruction of coronary bifurcations and plaque materials by combining intravascular ultrasound (IVUS) and angiography. Three patient-specific silicone bifurcation models were 3D reconstructed and compared to micro-computed tomography (µCT) as the gold standard to test the accuracy and reproducibility of the proposed methodology. The clinical feasibility of the method was investigated in three diseased patient-specific bifurcations of varying anatomical complexity. The IVUS-based 3D reconstructed bifurcation models showed high agreement with the µCT reference models, with r2 values ranging from 0.88 to 0.99. The methodology successfully 3D reconstructed all the patient bifurcations, including plaque materials, in less than 60 min. Our proposed method is a simple, time-efficient, and user-friendly tool for accurate 3D reconstruction of coronary artery bifurcations. It can provide valuable information about bifurcation anatomy and plaque burden in the clinical setting, assisting in bifurcation stent planning and education.


Asunto(s)
Enfermedad de la Arteria Coronaria , Placa Aterosclerótica , Humanos , Angiografía Coronaria/métodos , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Imagenología Tridimensional/métodos , Reproducibilidad de los Resultados , Microtomografía por Rayos X , Ultrasonografía Intervencional , Placa Aterosclerótica/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA