1.
Ann Work Expo Health ; 67(7): 886-894, 2023 08 09.
Artículo en Inglés | MEDLINE | ID: mdl-37436000

RESUMEN

Ortho-phthalaldehyde (OPA) is used as a high-level disinfectant for reusable medical devices in healthcare settings. The ACGIH recently adopted a Threshold Limit Value-Surface Limit (TLV-SL; 25 µg/100 cm2) for OPA surface contamination to prevent induction of dermal and respiratory sensitization following dermal exposure. However, there is no current validated method to measure OPA surface contamination. This study aimed to develop a standardized approach for sample collection and quantitative determination of OPA from work surfaces for use in risk assessment practices. The reported method utilises readily available commercial wipes to collect surface samples coupled with direct detection of OPA via liquid chromatography time of flight mass spectrometry (LC-ToF-MS). This approach avoided complex derivatization steps commonly required for the analysis of aldehydes. Method evaluation was conducted in accordance with the Occupational Safety and Health Administration (OSHA) surface sampling guidelines. Overall recoveries of 25 µg/100 cm2 of OPA from stainless steel and glass surfaces were 70% and 72%, respectively. The reported LOD for this method was 1.1 µg/sample and the LOQ was 3.7 µg/sample. OPA remained stable on the sampling medium for up to 10 days, when stored at 4 °C. The method was demonstrated in a workplace surface assessment at a local hospital sterilising unit, successfully detecting OPA on work surfaces. This method is intended to supplement airborne exposure assessment and provide a quantitative assessment tool for potential dermal exposure. When used in conjunction with a thorough occupational hygiene program that includes hazard communication, engineering controls, and personal protective equipment, skin exposure and consequent sensitization risks in the workplace can be minimized.


Asunto(s)
Desinfectantes , Exposición Profesional , Estados Unidos , Humanos , o-Ftalaldehído/análisis , Exposición Profesional/análisis , Desinfectantes/análisis , Aldehídos , Espectrometría de Masas
2.
Analyst ; 138(15): 4275-9, 2013 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-23749030

RESUMEN

We demonstrate the use of injected gallium electrodes for capacitively coupled contactless conductivity detection (C(4)D) within a microchip electrophoresis device. Evaluation of the electrodes for quantitative detection of electrophoretically separated lithium, sodium and potassium ions showed the system offers competitive detection limits of 6.1 × 10(-6) M, 6.7 × 10(-6) M and 8.5 × 10(-6) M, respectively. The fabrication process is fast, highly reproducible, and eliminates difficulties with electrode alignment. Using this approach C(4)D can be readily achieved in any microchip by simply adding extra 'electrode' channels to the microchip design.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...