Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
1.
J Endovasc Ther ; : 15266028241248600, 2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38708986

RESUMEN

PURPOSE: The primary aim of this study was to assess the 3-dimensional flare geometry of the Gore Viabahn VBX balloon-expandable covered stent (BECS) after fenestrated endovascular aortic repair (FEVAR) and to determine and visualize BECS-associated complications. METHODS: This multicenter retrospective study included patients who underwent FEVAR between 2018 and 2022 in 3 vascular centers participating in the VBX Expand Registry. Patients with at least one visceral artery treated with the VBX and with availability of 2 post-FEVAR computed tomography angiography (CTA) scans (follow-up [FU] 1: 0-6 months; FU2: 9-24 months) were included. The flare geometry of the VBX, including flare-to-fenestration distance, flare-to-fenestration diameter ratio, flare angle, and apposition with the target artery were assessed using a vascular workstation and dedicated CTA applied software. RESULTS: In total, 90 VBX BECS were analyzed in 43 FEVAR patients. The median CTA FU for FU1 and FU2 was 35 days (interquartile range [IQR], 29-51 days) and 14 months (IQR, 13-15 months), respectively. The mean flare-to-fenestration distance was 5.6±2.0 mm on FU1 and remained unchanged at 5.7±2.0 mm on FU2 (p=.417). The flare-to-fenestration diameter ratio was 1.19±0.17 on FU1 and remained unchanged at 1.21±0.19 (p=.206). The mean apposition length was 18.6±5.3 mm on FU1 and remained 18.6±5.3 mm (p=.550). The flare angle was 31°±15° on FU1 and changed to 33°±16° (p=.009). On FU1, the BECS-associated complication rate was 1%, and the BECS-associated reintervention rate was 0%. On FU2, the BECS-associated complication rate was 3%, and the BECS-associated reintervention rate was 1%. CONCLUSIONS: The flare geometry of the VBX bridging stent did not change significantly during 14 months follow-up in this study. Three-dimensional geometric analysis of the flare may contribute to identify the origin of endoleaks and occlusions, but this should be confirmed in a larger study including enough patients and BECS to compare complicated and uncomplicated cases. CLINICAL IMPACT: The three-dimensional flare geometry of the Gore Viabahn VBX BECS was assessed on the first and second postoperative CTA scans, and geometrical changes during this period were identified. For BECS that were diagnosed with a type 3c endoleak or occlusion, the BECS geometry was analyzed to detect geometrical components that were related to the complication. Geometric analysis of the flare may help to better detect and identify the cause of such complications.

3.
J Endovasc Ther ; : 15266028231179426, 2023 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-37287253

RESUMEN

PURPOSE: To present a rare cause of type III endoleak via the left renal artery (LRA) fenestration following fenestrated endovascular aneurysm repair (FEVAR) and to describe a successful reintervention for treating this endoleak. TECHNIQUE: The patient presented with a type IIIc endoleak following FEVAR, due to inadvertent placement of the LRA bridging balloon expandable covered stent (BECS) via the superior mesenteric artery (SMA) fenestration, but deployed outside the SMA fenestration. The proximal part of the BECS was positioned outside of the main body. This caused a type IIIc endoleak via the open LRA fenestration. Reintervention was performed by relining the LRA with a new BECS. First, access to the lumen of the previously placed BECS was gained using a re-entry catheter, followed by placement of a new BECS via the LRA fenestration. Completion angiography, and computerized tomography angiography (CTA) at 3 months follow-up showed total obliteration of the endoleak and patency of the LRA. CONCLUSION: Placement of a bridging stent via an incorrect fenestration during FEVAR is a rare cause of type III endoleak. In certain cases, successful treatment of such an endoleak could be achieved by perforation and relining of the misplaced BECS via the correct fenestration of the target vessel. CLINICAL IMPACT: To our best knowledge, a type IIIc endoleak following fenestrated endovascular aneurysm repair, due to placement of a bridging covered stent through an incorrect fenestration and deployed short of the fenestration, has not been described before. Reintervention was performed with perforation of the previously placed covered stent and relining using a new bridging covered stent. The technique presented here was successful for treating the endoleak in this case and could help guide clinicians when dealing with this or similar complications.

4.
Vasc Endovascular Surg ; 57(6): 555-563, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36802836

RESUMEN

OBJECTIVES: Fenestrated endovascular repair (FEVAR) has become a widely used treatment option for complex abdominal aortic aneurysms (AAA) but long-term survival and quality of life (QoL) outcomes are scarce. This single center cohort study aims to evaluate both long-term survival and QoL after FEVAR. METHODS: All juxtarenal and suprarenal AAA patients treated with FEVAR in a single-center between 2002 and 2016 were included. QoL scores, measured by the RAND 36-Item Short Form Survey (SF-36), were compared with baseline data of the SF-36 provided by RAND. RESULTS: A total of 172 patients were included at a median follow-up of 5.9 years (IQR 3.0-8.8). Follow-up at 5 and 10 years post-FEVAR yielded survival rates of 59.9% and 18%, respectively. Younger patient age at surgery had a positive influence on 10-year survival and most patients died due to cardiovascular pathology. Emotional well-being was better in the research group as compared to baseline RAND SF-36 1.0 data (79.2 ± 12.4 vs 70.4 ± 22.0; P < 0.001). Physical functioning (50 (IQR 30-85) vs 70.6 ± 27.4; P = 0.007) and health change (51.6 ± 17.0 vs 59.1 ± 23.1; P = 0.020) were worse in the research group as compared to reference values. CONCLUSIONS: Long-term survival was 60% at 5-years follow-up, which is lower than reported in recent literature. An adjusted positive influence of younger age at surgery was found on long-term survival. This could have consequences for future treatment indication in complex AAA surgery but further large-scale validation is necessary.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Calidad de Vida , Stents , Estudios de Cohortes , Factores de Riesgo , Resultado del Tratamiento , Complicaciones Posoperatorias , Estudios Retrospectivos , Procedimientos Endovasculares/efectos adversos , Diseño de Prótesis , Factores de Tiempo , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía
5.
Transplant Direct ; 9(2): e1435, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36700068

RESUMEN

Atherosclerosis of the aortoiliac vessels can adversely affect kidney perfusion after kidney transplantation. Atherosclerosis severity can be determined using the calcium score (CaScore). Potential problems with posttransplantation kidney perfusion can be determined using the intrarenal resistance index (RI). This study investigated the association between aortoiliac CaScore and RI in kidney transplant recipients. Methods: Kidney transplant recipients (2004-2019), for whom the CaScore and RI were determined, were included in this dual-center cohort study. CaScore was measured in 3 aortoiliac segments using noncontrast CT imaging. RI was determined using Doppler ultrasound. Multivariable linear regression analyses were performed between the CaScore and RI, adjusted for confounding variables. Results: The mean age of the 389 included patients was 59 (±13) y. The mean RI (unitless) was 0.71 (±0.09)' and the median CaScore (unitless) was 3340 (399-7833). In univariable linear regression analyses with RI as the dependent variable, CaScore (ß = 0.011; P < 0.001) was positively associated with RI. Moreover, recipient age (ß = 0.014; P < 0.001), history of diabetes (ß = 0.029; P = 0.003), recipient history of vascular interventions (ß = 0.032; P = 0.002), prior dialysis (ß = 0.029; P = 0.003), deceased donor transplantation (ß = 0.042; P < 0.001), donation after cardiac death (ß = 0.036; P = 0.001), an increase in cold ischemia time (ß = 0.011; P < 0.001), and the Comprehensive Complication Index (ß = 0.006; P = 0.002) were also positively associated with RI, whereas preoperative recipient diastolic blood pressure (ß = -0.007; P = 0.030) was inversely associated. In multivariable analyses, CaScore and RI remained significantly (P = 0.010) associated, independent of adjustment for potential confounders. Furthermore, in univariable linear regression analyses, multiple graft function characteristics were associated with RI. Conclusions: A significant association was found between CaScore and RI, independent of adjustment for multiple potential confounding factors, leading to a better insight into the development and interpretation of RI. Aortoiliac atherosclerosis should be considered when interpreting the RI and determining the possible cause of malperfusion and graft failure after kidney transplantation.

6.
J Endovasc Ther ; 30(2): 204-213, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-35227104

RESUMEN

PURPOSE: Changes in the flared end of balloon-expandable covered stent (BECS) may precede BECS-associated complications but are not regularly assessed with computed tomographic angiography (CTA) after fenestrated endovascular aneurysm repair (FEVAR). Validation of the flare geometric analysis (FGA) and assessment of intraobserver and interobserver variability are investigated in this study. METHODS: Two series of 3 BeGraft BECSs (Bentley InnoMed GmbH, Hechingen, Germany) and 1 series of 3 Advanta V12 BECSs (Getinge AB, Göteborg, Sweden) were deployed in 3 side branches (45°, 60°, and 90° aortic branch angles) of an aorta phantom model. A standard post-FEVAR CTA scan was acquired. Computed tomographic angiography-derived measurements consisted of centerline reconstructions and placement of 3-dimensional coordinate markers by 2 observers in a vascular workstation. Flare geometric analysis calculates 3 BECS parameters: the circumferential flare-to-fenestration distance (FFD), which is the distance from the proximal end of the flare to fenestration, and diameters at the proximal end of the flare (Dflare) and at the fenestration (Dfenestration). Computed tomographic angiography-derived measurements were validated against microscopy measurements. Bland-Altman plots were used to determine the intraobserver and interobserver variability of the BECS parameters and intraclass correlation coefficient (ICC). RESULTS: For each BECS, the FFD at 4 equidistant quadrants of the circumference, Dflare, and Dfenestration were calculated. The mean difference and repeatability coefficient (RC) of the validation were 0.8 (2.1) mm for FFD, 0.4 (1.0) mm for Dflare, and -0.2 (1.2) mm for Dfenestration. The mean intraobserver and interobserver difference (RC) was 0.5 (1.6) mm and 0.7 (2.6) mm for FFD, 0.1 (0.6) mm and 0.1 (0.7) mm for Dflare, and -0.1 (0.8) mm and -0.8 (1.0) mm for Dfenestration. The mean ICC of intraobserver variability was 0.86 for FFD, 0.94 for Dflare, and 0.78 for Dfenestration. The mean ICC of interobserver variability was 0.77 for FFD, 0.92 for Dflare, and 0.48 for Dfenestration. CONCLUSION: This study showed that FGA of the flared ends of BECS can be performed with high accuracy in a phantom model, with good intraobserver and interobserver variability. Flare geometric analysis can be used to determine flare geometry of the BECS on standard post-FEVAR CTA scans.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Prótesis Vascular , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/efectos adversos , Reparación Endovascular de Aneurismas , Procedimientos Endovasculares/efectos adversos , Resultado del Tratamiento , Stents , Diseño de Prótesis
7.
J Clin Med ; 11(19)2022 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-36233579

RESUMEN

In balloon-expandable covered stent (BECS) associated complications after fenestrated endovascular aneurysm repair (FEVAR), geometric analysis may determine the cause of failure and influence reintervention strategies. This study retrospectively classifies BECS-associated complications based on computed tomographic angiography (CTA) applied geometric analysis. BECS-associated complications of FEVAR-patients treated in two large vascular centers between 2012 and 2021 were included. The post-FEVAR CTA scans of complicated Advanta V12 BECSs were analyzed geometrically and complications were classified according to its location in the BECS. BECS fractures were classified according to an existing classification system. In 279 FEVAR-patients, 34 out of the 683 included Advanta V12 BECS (5%) presented with a complication. Two Advanta V12 complications occurred during the FEVAR procedure and 32 occurred during follow-up of which five post-FEVAR CTA scans were missing or not suitable for analysis. In the remaining 27 BECSs complications were classified as (endoleaks (n = 8), stenoses (n = 4), occlusions (n = 6), fractures (n = 3), and a combination of complications (n = 6)). All BECSs associated complications after FEVAR with available follow up CTA scans could be classified. Geometric analysis of BECS failure post-FEVAR can help to plan the reintervention strategy.

8.
J Endovasc Ther ; 28(5): 700-706, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34008441

RESUMEN

PURPOSE: Fenestrated endovascular aneurysm repair (FEVAR) is a well-established endovascular treatment option for pararenal abdominal aortic aneurysms in which balloon-expandable covered stents (BECS) are used to bridge the fenestration to the target vessels. This study presents midterm clinical outcomes and patency rates of the Advanta V12 BECS used as a bridging stent. METHODS: All patients treated with FEVAR with at least 1 Advanta V12 BECS were included from 2 large-volume vascular centers between January 2012 and December 2015. Primary endpoints were freedom from all-cause reintervention, and freedom from BECS-associated complications and reintervention. BECS-associated complications included significant stenosis, occlusion, type 3 endoleak, or stent fracture. Secondary endpoints included all-cause mortality in-hospital and during follow-up. RESULTS: This retrospective study included 194 FEVAR patients with a mean age of 72.2±8.0 years. A total of 457 visceral arteries were stented with an Advanta V12 BECS. Median (interquartile range) follow-up time was 24.6 (1.6, 49.9) months. The FEVAR procedure was technically successful in 93% of the patients. Five patients (3%) died in-hospital. Patient survival was 77% (95% CI 69% to 84%) at 3 years. Freedom from all-cause reintervention was 70% (95% CI 61% to 78%) at 3 years, and 33% of all-cause reinterventions were BECS associated. Complications were seen in 24 of 457 Advanta V12 BECSs: type 3 endoleak in 8 BECSs, significant stenosis in 4 BECSs, occlusion in 6 BECSs, and stent fractures in 3 BECSs. A combination of complications occurred in 3 BECSs: type 3 endoleak and stenosis, stent fracture and stenosis, and stent fracture and occlusion. The freedom from BECS-associated complications for Advanta V12 BECSs was 98% (95% CI 96% to 99%) at 1 year and 92% (95% CI 88% to 95%) at 3 years. The freedom from BECS-associated reinterventions was 98% (95% CI 95% to 100%) at 1 year and 94% (95% CI 91% to 97%) at 3 years. CONCLUSION: The Advanta V12 BECS used as bridging stent in FEVAR showed low complication and reintervention rates at 3 years. A substantial number of FEVAR patients required a reintervention, but most were not BECS related.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Humanos , Persona de Mediana Edad , Diseño de Prótesis , Estudios Retrospectivos , Stents , Factores de Tiempo , Resultado del Tratamiento
9.
J Endovasc Ther ; 27(5): 848-856, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32567964

RESUMEN

Purpose: To compare the impact of 2 commercially available custom-made fenestrated endografts on patient anatomy. Materials and Methods: The records of 234 patients who underwent fenestrated endovascular aneurysm repair for abdominal aortic aneurysm from March 2002 to July 2016 in 2 hospitals were screened to identify those who had pre- and postoperative computed tomography angiography assessments with a slice thickness of ≤2 mm. The search identified 145 patients for further analysis: 110 patients (mean age 72.4±7.1 years; 94 men) who had been treated with the Zenith Fenestrated (ZF) endograft and 35 patients (mean age 72.3±7.3 years; 30 men) treated with the Fenestrated Anaconda (FA) endograft. Measurements included aortic diameters at the level of the superior mesenteric artery (SMA) and renal arteries, target vessel angles, target vessel clock positions, and the target vessel tortuosity index. Variables were tested for inter- and intraobserver agreement. Results: There was a good agreement between observers in all tested variables. The native anatomy changed in both groups after endograft implantation. In the ZF group, changes were seen in the angles of the celiac artery (p=0.012), SMA (p=0.022), left renal artery (LRA) (p<0.001), and the right renal artery (RRA) (p<0.001); the aortic diameter at the SMA level (p<0.001); and the LRA (p<0.001) and RRA (p<0.001) clock positions. In the FA group, changes were seen in the angles of the LRA (p=0.001) and RRA (p<0.001) and in the SMA tortuosity index (p=0.044). Between group differences in changes were seen for the aortic diameters at the SMA and renal artery levels (p<0.001 for both) and the LRA clock position (p=0.019). Conclusion: Both custom-made fenestrated endografts altered vascular anatomy. The data suggest a higher conformability of the Fenestrated Anaconda endograft compared with the Zenith Fenestrated.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Stents , Anciano , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/fisiopatología , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Femenino , Humanos , Masculino , Países Bajos , Diseño de Prótesis , Estudios Retrospectivos , Resultado del Tratamiento
10.
Eur J Vasc Endovasc Surg ; 59(1): 24-30, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31727436

RESUMEN

OBJECTIVE: An ageing population leads to more age related diseases, such as complex abdominal aortic aneurysms (AAA). Patients with complex AAAs and multiple comorbidities benefit from fenestrated endovascular aneurysm repair (FEVAR), but for the elderly this benefit is not completely clear. METHODS: Between 2001 and 2016 all patients treated for complex AAA by FEVAR at two tertiary referral centres were screened for inclusion. Group 1 consisted of patients aged 80 years and older and group 2 of patients younger than 80 years of age. The groups were compared for peri-operative outcome, as well as patient and re-intervention free survival, and target vessel patency during follow up. RESULTS: Group 1 consisted of 42 patients (median age 82 years; interquartile range [IQR] 81-83 years) and group 2 of 230 patients (median age 72 years; IQR 67-77 years). No differences were seen in pre-operative comorbidities, except for age and renal function. Renal function was 61.4 mL/min/1.73 m2vs.74.5 mL/min/1.73 m2 (p < .01). No differences were seen between procedures, except for a slightly longer operation time in group two. Median follow up was 26 and 32 months, respectively. No difference was seen between the groups for estimated cumulative overall survival (p = .08) at one, three, and five years, being 95%, 58%, and 42% for group 1, and 88%, 75%, and 61% for group 2, respectively. There was no difference seen between groups for the estimated cumulative re-intervention free survival (p = .95) at one, three, and five years, being 84%, 84%, and 84% in group 1, respectively, and 88%, 84%, and 82% in group 2, respectively. Ultimately, no difference was seen between groups for the estimated cumulative target vessel patency (p = .56) at one, three, and five years, being 100%, 100%, and 90% for group 1, and 96%, 93% and 92% for group 2, respectively. CONCLUSION: Age itself is not a reason to withhold FEVAR in the elderly, and choice of treatment should be based on the patient's comorbidities and preferences.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Procedimientos Endovasculares/métodos , Stents , Factores de Edad , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/mortalidad , Toma de Decisiones Clínicas , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Femenino , Estudios de Seguimiento , Humanos , Masculino , Prioridad del Paciente , Reoperación/estadística & datos numéricos , Estudios Retrospectivos , Factores de Riesgo , Análisis de Supervivencia , Resultado del Tratamiento , Grado de Desobstrucción Vascular
11.
J Vasc Surg ; 70(3): 702-709, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30837180

RESUMEN

OBJECTIVE: The objective of this study was to assess long-term durability of bridging stents in branched and combined branched and fenestrated endovascular aneurysm repair (B/F-EVAR) for thoracoabdominal aortic aneurysm (TAAA) and pararenal abdominal aortic aneurysm. METHODS: A retrospective database analysis was performed of patients treated by B/F-EVAR for TAAA. Computed tomography angiography images were analyzed to assess patency, bridging stent angulation and migration, aneurysm diameter, and migration of the endograft. RESULTS: Twenty-eight patients with a median age of 70 years (interquartile range [IQR], 67-77 years) were included. Assisted technical success was 89%. Within 30 days postoperatively, five patients died. In the remaining 23 patients, median follow-up was 5.3 years (IQR, 2.9-7.2 years), and 1-, 3-, and 5-year estimated overall survival was 69%, 65%, and 44%, respectively. During follow-up, 12 of 47 (26%) branches occluded and 5 of 47 (11%) branches developed a 70% to 99% stenosis. The 1-, 3-, and 5-year estimated freedom from adverse events was 78%, 76%, and 59% for branch stents and 100%, 96%, and 90% for fenestration stents, respectively. The median distal bridging stent migration was 0.5 mm (IQR, -1.9 to 1.4; P > .05 mm). In 10 branches, migration >10 mm was seen, ranging from 14.1 mm sliding in to 23.0 mm sliding out. The angulation between branch and stent became 4 degrees more angulated (IQR, -14 to +2 degrees). In 23 branches, the angulation changed 10 degrees or more, leading to an occlusion in 7 branches, a 70% to 99% stenosis in 3 branches, and a 50% to 70% stenosis in 4 branches. In three cases, the endograft migrated >5 mm caudally, with a breach in a fenestration stent in one and a breach in a branch stent in another. CONCLUSIONS: The anatomic configuration of branches in B/F-EVAR of TAAAs and pararenal abdominal aortic aneurysms changes over time. The change in angle of branches and the bridging stent influences the likelihood of stenosis and occlusion. Follow-up of B/F-EVAR should include computed tomography angiography measurements of aortic diameter, endograft migration, target vessel stent length, and angulation to detect disconnection, stenosis, and occlusion.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Torácica/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Stents , Anciano , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Implantación de Prótesis Vascular/efectos adversos , Bases de Datos Factuales , Procedimientos Endovasculares/efectos adversos , Femenino , Migración de Cuerpo Extraño/etiología , Oclusión de Injerto Vascular/etiología , Humanos , Masculino , Diseño de Prótesis , Falla de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
12.
J Vasc Surg Cases Innov Tech ; 5(1): 65-67, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30911702

RESUMEN

We present a simple solution to address-at the same time-the issue of spinal perfusion, overload on the left ventricle, and brain perfusion during complex distal arch and descending aortic surgery. It is a modification of a passive Gott shunt that includes an extra 10-mm tube interposed between the side port of the ascending aorta cannula and the left subclavian artery. This technique may represent an extra option for surgeons during complex aortic surgery to maintain satisfactory distal perfusion, to reduce the cardiac load, and to provide adequate perfusion to the brain.

13.
Aorta (Stamford) ; 7(6): 172-175, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32074645

RESUMEN

This report describes a case of a taxidermist who presented with sepsis and excruciating back pain a few weeks after contact with a deceased horse. Streptococcus equi subspecies zooepidemicus (SESZ) was isolated from patient's blood and two isolated mycotic aneurysms were found. The first was located in the distal abdominal aorta and the second in the right common iliac artery. Treatment consisted of penicillin administration for 6 weeks and surgical debridement of the infected tissue combined with autologous vein reconstruction. The patient was infection-free without complaints 1 year after discharge and the venous reconstruction was patent. Reports in literature of bacteremia with SESZ leading to the development of mycotic aneurysms are very scarce and show that prognosis is generally unfavorable.

14.
Surg Technol Int ; 33: 239-250, 2018 Nov 11.
Artículo en Inglés | MEDLINE | ID: mdl-30117134

RESUMEN

Currently, there is a wide range of commercially available endografts for infrarenal abdominal aortic aneurysm (AAA) repair. Results of long-term follow up after endovascular aneurysm repair (EVAR) are limited. Thereby, the durability of these endografts and the difference between manufacturers is not fully clear. In this review, studies with mid- and long-term results, with a minimum median follow up of 36 months per endograft, were included describing results with Cook Zenith? Flex? endograft (Cook Medical Inc., Bloomington, Indiana) (n=6), Cordis Corporate INCRAFT? (Cordis Corporation, Freemont, California) (n=1), Gore? EXCLUDER? (W.L. Gore & Associates Inc., Flagstaff, Arizona) (n=3), Medtronic Endurant? (Medtronic plc, Santa Rosa, California) (n= 6), and Vascutek Anaconda? (Vascutek Ltd., Inchinnan, Scotland) (n=2). The assisted technical success varied between 83% and 100%, and the perioperative mortality, early reintervention, and early conversion rates were comparable for the studied endografts. At three-year follow up, the freedom from AAA-rupture and AAA-related death varied between 98% and 100%. The results demonstrated an increasing complication and reintervention rate over time. When adhering to the instruction for use, minor differences were seen during follow up between the endografts. Latest generation endografts continue to have good postoperative results, the reintervention-rate of 10-20% over time mandates an ongoing close patient follow up. The choice of a specific design depends on native patient anatomy and the experience of the implanting surgeon.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular , Prótesis Vascular , Procedimientos Endovasculares , Humanos , Complicaciones Posoperatorias , Reoperación , Resultado del Tratamiento
15.
PLoS One ; 13(2): e0193419, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29489868

RESUMEN

OBJECTIVE: Quantification software for coronary calcification is often used to measure abdominal aortic calcification on computed tomography (CT) images. However, there is no evidence substantiating the reliability and accuracy of these tools in this setting. Differences in coronary and abdominal CT acquisition and presence of intravascular contrast may affect the results of these tools. Therefore, this study investigates the effects of CT acquisition parameters and iodine contrast on automated quantification of aortic calcium on CT. METHODS: Calcium scores, provided in volume and mass, were assessed by automated calcium quantification software on CT scans. First, differences in calcium scores between the abdominal and coronary CT scanning protocols were assessed by imaging a thorax phantom containing calcifications of 9 metrical variations. Second, aortic calcification was quantified in 50 unenhanced and contrast-enhanced clinical abdominal CT scans at a calcification threshold of 299 Hounsfield Units (HU). Also, the lowest possible HU threshold for calcifications was calculated per individual patient and compared to a 130 HU threshold between contrast-enhanced and unenhanced CT images, respectively. RESULTS: No significant differences in volume and mass scores between the abdominal and the coronary CT protocol were found. However, volume and mass of all calcifications were overestimated compared to the physical volume and mass (volume range: 0-649%; mass range: 0-2619%). In comparing unenhanced versus contrast-enhanced CT images showed significant volume differences for both thresholds, as well as for mass differences for the 130 vs patient-specific threshold (230 ± 22.6 HU). CONCLUSION: Calcification scoring on CT angiography tends to grossly overestimate volume and mass suggesting a low accuracy and reliability. These are reduced further by interference of intravascular contrast. Future studies applying calcium quantification tools on CT angiography imaging should acknowledge these issues and apply corrective measures to ensure the validity of their outcomes.


Asunto(s)
Aorta Abdominal/diagnóstico por imagen , Aorta Abdominal/metabolismo , Proyectos de Investigación , Tomografía Computarizada por Rayos X , Calcificación Vascular/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador , Fantasmas de Imagen , Dosis de Radiación , Reproducibilidad de los Resultados
16.
J Vasc Surg ; 67(6): 1797-1804, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29291906

RESUMEN

OBJECTIVE: The position of endovascular treatment in the algorithm of popliteal artery aneurysm (PAA) repair is still a matter of debate. Although several studies have described results similar to those of open surgery, follow-up of the endovascular group has been relatively short so far. The aim of this study was to describe the long-term outcome of endovascular repair of PAA with endografts. METHODS: All patients with a PAA treated with an expanded polytetrafluoroethylene stent graft between June 1998 and November 2014 in a tertiary referral center were prospectively gathered in a database and retrospectively analyzed. The primary end point of this study was primary patency. Secondary end points included primary assisted and secondary patency, survival of the patient, stent fractures, secondary interventions, and limb loss. RESULTS: A total of 75 PAAs were treated in 64 patients with a mean age of 68.1 ± 9.4 years. Unilateral PAA was present in 39 patients (61%) and bilateral PAAs in 25 patients (39%), of which 11 (17%) were treated bilaterally. Median follow-up was 68 months (range, 2-187 months). Primary patency at 1 year, 5 years, and 10 years was 84%, 60%, and 51%, respectively; primary assisted patency, 84%, 65%, and 57%; and secondary patency, 89%, 71%, and 60%. Stent fractures occurred in 28% of the cases (n = 21) in a median follow-up time of 47 months (range, 14-187 months). One-third of the fractures were associated with an occlusion that mainly presented with claudication, and only one was associated with acute ischemia. Reinterventions were performed in 12 cases (16%) during a median follow-up of 14 months (range, 1-47 months). The reintervention-free survival after 1 year, 5 years, and 10 years was 93%, 79%, and 79%, respectively. No major amputations were performed. The overall survival rate after 5 years and 10 years was 78% and 46%, respectively. CONCLUSIONS: Endovascular repair has established a definitive role in the treatment protocol for PAAs. It is associated with acceptable long-term patency rates. Stent fractures occurred in almost one-third of cases but never led to limb loss. Future developments should focus on the design of more dedicated and durable stents for this specific indication.


Asunto(s)
Aneurisma/cirugía , Prótesis Vascular , Procedimientos Endovasculares/métodos , Politetrafluoroetileno , Arteria Poplítea , Complicaciones Posoperatorias/epidemiología , Stents , Anciano , Aneurisma/diagnóstico , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Países Bajos/epidemiología , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
17.
Aorta (Stamford) ; 6(4): 102-106, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30849778

RESUMEN

An 81-year-old patient presented to the emergency room 5 years after infrarenal endovascular aneurysm repair, with a Type Ia endoleak and a presumable infection of the graft material with Listeria monocytogenes. He was treated with a custom-made fenestrated endograft to seal the endoleak and lifelong antibiotic therapy to suppress the infection. Full explantation of graft material is not always preferable, and endovascular treatment combined with antibiotic suppressive therapy is in some cases an appropriate alternative.

18.
Aorta (Stamford) ; 5(1): 27-29, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28868312

RESUMEN

A 70-year-old man was successfully treated for an aortoduodenal fistula originating from a Q fever-related abdominal aortic aneurysm. He had no known history of contact with cattle or sheep. Although the combination of abdominal aortic aneurysm and aortoduodenal fistula is rare, one should be suspicious of Q fever infection as the causative agent, and additional medical treatment should be initiated.

19.
J Vasc Interv Radiol ; 28(5): 637-644.e1, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28318830

RESUMEN

PURPOSE: To evaluate long-term outcome of GORE EXCLUDER AAA Endoprosthesis (W.L. Gore & Associates, Inc, Flagstaff, Arizona) for elective treatment of infrarenal aortic aneurysms and to evaluate performance of different generations of the device. MATERIALS AND METHODS: A retrospective analysis was performed of 248 patients undergoing elective endovascular aneurysm repair with the GORE EXCLUDER between January 2000 and December 2015 in 2 hospitals. Primary endpoint was reintervention-free survival. Secondary endpoints were technical success, overall survival, rupture-free survival, endoleaks, sac diameter change (> 5 mm), limb occlusion, and migration (> 5 mm). Median follow-up time was 26 months (range, 1-190 months). RESULTS: Assisted primary technical success was 96.8%. Reintervention-free survival for 5 and 10 years was 85.2% and 75.6%, respectively. Independent risk factors for reintervention were technical success (P < .001), type I endoleak (P < .001), and type II endoleak (P = .003). Late adverse events requiring reintervention included rupture (0.4%), limb occlusion (0.4%), and stent migration (0.4%). Type Ia (4.8%), Ib (2.8%), II (35.9%), and V (6.5%) endoleaks were reported throughout follow-up. Sac growth was more prevalent with the original GORE EXCLUDER compared with the low permeability GORE EXCLUDER (P = .001) and in the presence of type I, II, and V endoleaks (P < .05). Three conversions (1.2%) were performed. Overall survival at 5 and 10 years was 68.4% and 49.0%, with no reported aneurysm-related deaths. CONCLUSIONS: Treatment with the GORE EXCLUDER is effective with acceptable reintervention rates in the long-term and few device-related adverse events or ruptures up to 10 years. Observed late adverse events and new-onset endoleaks emphasize the need for long-term surveillance.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Anciano , Endofuga/etiología , Femenino , Humanos , Masculino , Complicaciones Posoperatorias/etiología , Diseño de Prótesis , Reoperación , Estudios Retrospectivos , Factores de Riesgo , Tasa de Supervivencia , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...