RESUMEN
We evaluated the performance of a commercial rapid diagnostic test (RDT) in a field setting for the diagnosis of abdominal cystic echinococcosis (CE) using sera collected during an ultrasound population screening in a highly endemic region of the Peruvian Andes. Abdominal CE was investigated by ultrasonography. Sera collected from individuals with abdominal CE (cases) and age- and gender-matched volunteers with no abdominal CE (controls) were tested independently in two laboratories (Peru and Italy) using the VIRapid® HYDATIDOSIS RDT and RIDASCREEN® Echinococcus IgG enzyme-linked immunosorbent assay. Performance indexes of single and serially combined tests were calculated and applied to hypothetical screening and clinical scenarios. Test concordance was also evaluated. Prevalence of abdominal CE was 6.00% (33 of 546) by ultrasound. Serum was obtained from 33 cases and 81 controls. The VIRapid test showed similar sensitivity (76% versus 74%) and lower specificity (79% versus 96%) than results obtained in a hospital setting. RDTs showed better performance when excluding subjects reporting surgery for CE and if weak bands were considered negative. Concordance between tests was moderate to very good. In hypothetical screening scenarios, ultrasound alone or confirmed by RDTs provided more reliable prevalence figures than serology alone, which overestimated it by 5 to 20 times. In a simulation of case diagnosis with pre-test probability of CE of 50%, positive and negative post-test probabilities of the VIRapid test were 78% and 22%, respectively. The application of the VIRapid test alone would not be reliable for the assessment of population prevalence of CE, but could help clinical decision making in resource-limited settings.
Asunto(s)
Anticuerpos Antihelmínticos/sangre , Pruebas Diagnósticas de Rutina/métodos , Equinococosis/diagnóstico , Equinococosis/terapia , Echinococcus/genética , Pruebas Serológicas/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Animales , Niño , Preescolar , Equinococosis/epidemiología , Monitoreo Epidemiológico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Perú/epidemiología , Adulto JovenRESUMEN
RATIONALE FOR THE STUDY: This cross-sectional multicenter study was conducted to investigate any difference in liver stiffness measurements (LSM), evaluated by transient elastography, between patients affected by ß thalassaemia major, with and without hepatitis C virus (HCV) infection, and healthy blood donors (controls). Secondary aim was to assess any correlation between transient elastography and serum ferritin, liver magnetic resonance imaging (MRI) T2* or superconductive quantum interference device (SQUID) liver susceptometry values. MATERIALS AND METHODS: The study involved three centers. Transient elastography and MRI T2* examinations were performed in all centers. SQUID liver susceptometry was performed in center1 and center2. T-test for independent data or Mann-Whitney U test was used to analyse differences between two groups. Univariate Pearson's r coefficient was used to test correlations between liver stiffness measurements and all other variables. RESULTS: In a study with 119 patients and 183 controls, patients who had never been infected with HCV showed significantly higher LSMs than controls [5.7 (95% CI, 5.2-6.2) kPa vs. 4.3 (95% CI, 4.1-4.4) kPa, p < 0.0001]. A moderate correlation between LSMs and ferritin values, adjusted for gender and age, was found in patients (r = 0.49, p < 0.0001) but not in controls (r = -0.22, p = 0.6). No correlation between LSMs and MRI T2* or SQUID liver susceptometry values was observed. In conclusion, compared to controls ß thalassaemia major patients had a significant increase in LSMs independently from HCV infection.