Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
2.
World J Surg ; 48(2): 350-360, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38686758

RESUMEN

BACKGROUND: Postinjury multiple organ failure (MOF) is the leading cause of late trauma deaths, with primarily non-modifiable risk factors. Timing of surgery as a potentially modifiable risk factor is frequently proposed, but has not been quantified. We aimed to compare mortality, hospital length of stay (LOS), and ICU LOS between MOF patients who had surgery that preceded MOF with modifiable timings versus those with non-modifiable timings. METHODS: Retrospective analysis of an ongoing 17-year prospective cohort study of ICU polytrauma patients at-risk of MOF. Among MOF patients (Denver score>3), we identified patients who had surgery that preceded MOF, determined whether the timing of these operation(s) were modifiable(M) or non-modifiable (non-M), and evaluated the change in physiological parameters as a result of surgery. RESULTS: Of 716 polytrauma patients at-risk of MOF, 205/716 (29%) developed MOF, and 161/205 (79%) had surgery during their ICU admission. Of the surgical MOF patients, 147/161 (91%) had one or more operation(s) that preceded MOF, and 65/161 (40%) of them had operation(s) with modifiable timings. There were no differences in age (mean (SD) 52 (19) vs 53 (21)years), injury severity score (median (IQR) 34 (26-41)vs34 (25-44)), admission physiological and resuscitation parameters, between M and non-M-patients. M patients had longer ICU LOS (median (IQR) 18 (12-28)versus 11 (8-16)days, p < 0.0001) than non-M-patients, without difference in mortality (14%vs16%, p = 0.7347), or hospital LOS (median (IQR) 32 (18-52)vs27 (17-47)days, p = 0.3418). M-patients had less fluids and transfusions intraoperatively. Surgery did not compromise patient physiology. CONCLUSION: Operations preceding MOF are common in polytrauma and seem to be safe in maintaining physiology. The margin for improvement from optimizing surgical timing is modest, contrary to historical assumptions.


Asunto(s)
Tiempo de Internación , Insuficiencia Multiorgánica , Traumatismo Múltiple , Humanos , Insuficiencia Multiorgánica/mortalidad , Insuficiencia Multiorgánica/etiología , Femenino , Masculino , Persona de Mediana Edad , Tiempo de Internación/estadística & datos numéricos , Estudios Retrospectivos , Adulto , Traumatismo Múltiple/cirugía , Traumatismo Múltiple/mortalidad , Traumatismo Múltiple/complicaciones , Factores de Tiempo , Unidades de Cuidados Intensivos/estadística & datos numéricos , Factores de Riesgo , Mortalidad Hospitalaria , Estudios Prospectivos , Anciano
3.
ANZ J Surg ; 93(12): 2958-2963, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37953528

RESUMEN

BACKGROUND: Postoperative stiffness affects up to 20% of patients following arthroscopic rotator cuff repair. Recent evidence indicates that early postoperative stiffness may associated with lower retear rates. This study aimed to identify the independent predictors of early postoperative stiffness. METHODS: A retrospective cohort study of 1526 rotator cuff repairs was performed. Range of motion at 6-week postop was used to identify stiff patients. Stiffness was defined as external rotation <27.5o or forward flexion <145o . Multiple logistic regression analysis was used to identify the independent predictors of 6-week stiffness. RESULTS: The independent predictors for external rotation stiffness at 6-week postop were more recent cases (Wald = 60), restricted preoperative external rotation (Wald = 36), younger age (Wald = 21) and poorer surgeon-ranked tissue quality (Wald = 15). The independent predictors for forward flexion stiffness were more recent cases (Wald = 101), restricted preoperative forward flexion (Wald = 16) and external rotation (Wald = 13) and female patients (Wald = 12). All patients that developed early postoperative stiffness had recovered range of motion by 6 months to preoperative levels (P < 0.0001). A significantly greater proportion of younger patients (40-49) developed postoperative stiffness when compared to older patients aged 50-59 (P < 0.0062), 70-79 (P < 0.0126) and 80-89 (P < 0.004). Patients that retore had significantly greater average 6-week postoperative range of motion. CONCLUSIONS: Patients earlier in the study were found to have greater postoperative range of motion, which coincided with a more aggressive rehabilitation program with less immobilization. Thus, the data supports the hypothesis that a temporary period of shoulder stiffness facilitates tendon repair and ultimately a better outcome post rotator cuff repair.


Asunto(s)
Lesiones del Manguito de los Rotadores , Articulación del Hombro , Humanos , Femenino , Manguito de los Rotadores/cirugía , Lesiones del Manguito de los Rotadores/cirugía , Estudios Retrospectivos , Articulación del Hombro/cirugía , Resultado del Tratamiento , Artroscopía , Rango del Movimiento Articular
4.
J Shoulder Elbow Surg ; 32(10): e495-e503, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37414354

RESUMEN

BACKGROUND: There are several approaches to the management of distal biceps tendon ruptures, with no consensus on what constitutes best practice. METHODS: An online survey queried the perceptions and management of distal biceps tendon ruptures amongst fellowship-trained subspecialty elbow surgeons, which primarily comprised of members of the Shoulder and Elbow Society of Australia, the national subspecialist interest group of the Australian Orthopaedic Association and the Mayo Clinic Elbow Club (Rochester, MN, USA). RESULTS: One hundred surgeons responded. The median (IQR) experience as orthopedic surgeons amongst respondents was 17 (10-23) years; 78% of respondents saw >10 cases of distal biceps tendon ruptures annually; 95% of respondents would recommend surgery for symptomatic radiologically-confirmed partial tears, the most common indications being pain (83%), weakness (60%), and tear size (48%). Forty-three percent of respondents would have grafts available for tears older than 6 weeks. The one-incision approach (70%) was preferred over two incisions (30%); 78% of one-incision users believed that their repair location was anatomic, compared to 100% of two-incision users. One-incision users were more likely to have encountered lateral antebrachial cutaneous nerve (78% vs. 46%) and superficial radial nerve palsies (28% vs. 11%). Two-incision users were more likely to have encountered posterior interosseus nerve palsy (21% vs. 15%), heterotopic ossification (54% vs. 42%), and synostosis (14% vs. 0%). Re-ruptures were the most common cause of reoperation. The more conservative a respondent's postoperative immobilization was, the less likely they were to have ever encountered re-rupture (14% amongst cast users, 29% amongst splint/brace users, 49% amongst sling users, 100% amongst non-immobilizers). Thirty percent of respondents who placed elbow strength restrictions for 6 months postoperatively encountered re-rupture, compared to 40% amongst those who restricted for 6-12 weeks postoperatively. CONCLUSIONS: The operation rate for repair of distal biceps tendon ruptures amongst subspecialist elbow surgeons is high, as seen in our cohort. However, there is a large variation in the approach toward its management. One incision (anterior) was preferred over two incisions (anterior and posterior). Complications from repair of distal biceps tendon ruptures can be expected even amongst subspecialists, and are associated with surgical approach. The responses imply that more conservative postoperative rehabilitation may be associated with a lower risk of re-rupture.


Asunto(s)
Cirujanos , Traumatismos de los Tendones , Humanos , Codo/cirugía , Becas , Traumatismos de los Tendones/cirugía , Estudios Retrospectivos , Australia , Tendones , Rotura/cirugía , Encuestas y Cuestionarios
5.
Orthop J Sports Med ; 11(6): 23259671231175883, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37347026

RESUMEN

Background: The addition of onlay biological grafts to augment difficult rotator cuff repairs has shown encouraging results in a case series. Purpose/Hypothesis: The purpose of this study was to determine whether the addition of an onlay bioinductive implant would improve repair integrity, shear wave elastographic appearance of the repaired tendon and patch, and patient-rated and/or surgeon-measured shoulder function when used in workers' compensation patients undergoing revision arthroscopic rotator cuff repair. We hypothesized that the addition of the bioinductive implant would enhance repair integrity and clinical outcomes compared with standard repair. Study Design: Cohort study; Level of evidence, 3. Methods: A post hoc matched-cohort study was conducted on prospectively recruited workers' compensation patients who received a bioinductive implant for revision rotator cuff repair (n = 19). The control group was selected from consecutive workers' compensation revision rotator cuff repair patients before the introduction of bioinductive implants. Then, they were matched for age and tear size (n = 32). Kaplan-Meier curves were generated to compare the primary outcome of repair integrity between groups. The secondary outcomes were to evaluate the elastographic appearance of the tendon and patch in the bioinductive implant group and to compare patient-rated and surgeon-measured shoulder function between groups preoperatively and at 1 week, 6 weeks, 3 months, and 6 months postoperatively. Results: No major complications associated with the bioinductive implants were identified. Six months after the revision rotator cuff repair, the retear rate in the bioinductive implant group was 16% (3/19), compared with 19% (6/32) in the age- and tear size-matched control group (P = .458). At the final follow-up, the retear rate in the bioinductive implant group was 47% (9/19) at a mean of 14 months compared with 38% (12/32) at a mean of 29 months in the control group (P = .489). The shear wave elastographic stiffness of repaired tendons augmented with the bioinductive implant remained unchanged at 6 m/s from 1 week to 6 months postoperatively, which is lower than the stiffness of 10 m/s in healthy tendons. There were no significant differences in patient-rated or surgeon-measured outcomes between groups 6 months postoperatively. Conclusion: There were no differences in repair integrity or clinical outcomes between workers' compensation patients who underwent revision arthroscopic rotator cuff repair with an onlay bioinductive implant compared to those who underwent standard revision rotator cuff repair.

6.
J Clin Med ; 12(7)2023 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-37048790

RESUMEN

BACKGROUND: Superior capsular reconstruction (SCR) for massive, irreparable rotator cuff tears involves anchoring a graft between the superior glenoid and the greater tuberosity of the humerus. Optimizing the graft size is important. We aimed (1) to evaluate the reliability of plain film radiography in determining graft size for SCR and (2) to create a database to help predict future graft sizes. METHODS: An inter- and intra-rater reliability trial was conducted on 10 and 6 subjects with healthy shoulders, respectively, using plain film radiography to measure the distance between the superior glenoid and the supraspinatus footprint. The subjects were positioned upright with an abduction pillow modified to hold the shoulder at 30° abduction and 45° external rotation, afterwhich a true antero-posterior shoulder radiograph was captured. Thirty subjects were recruited for the database and grouped using the aforementioned protocol. RESULTS: The inter-rater and intra-rater trial agreement was excellent, with intraclass correlation coefficients of 0.94 (95% CI) and 0.76 (95% CI), respectively. Three medio-lateral patch sizes, of 33 mm, 38 mm, and 47 mm, were proposed based on the protocol in 30 subjects. CONCLUSIONS: Plain film radiography demonstrated excellent reliability in measuring the distance between the superior glenoid and the supraspinatus footprint. Three ordinal patch sizes are proposed.

7.
J Ultrasound Med ; 42(8): 1799-1808, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36851879

RESUMEN

OBJECTIVES: How the material properties of the human supraspinatus tendon change following arthroscopic rotator cuff repair is undetermined. Shear wave elastography ultrasound is a relatively new, noninvasive measure of tissue stiffness. We aimed to evaluate any temporal changes in stiffness and/or thickness of supraspinatus tendons in humans following primary arthroscopic rotator cuff repair. METHODS: Shear wave elastography was performed at three predetermined regions by a single sonographer at 1-, 6-, 12-, 24-, and 52 weeks postoperatively in 50 consecutive single-row inverted mattress primary arthroscopic rotator cuff repairs. One-way ANOVA with Tukey's correction and Spearman's correlation tests was performed. RESULTS: Of 50 patients, two retore by 1-week and were excluded. Two patients retore at 6 weeks, two at 12 weeks, and one at 24 weeks. The mean tendon stiffness in 48 patients at the tendon footprint increased by 21% (1.32 m/s) at 6 months (P < .001), with the lateral tendon stiffening before the medial tendon. Tendon thickness decreased by 11% (0.6 mm) at 6 weeks (P = .008), then stabilized to 24 weeks. Tendons that were less elastographically stiff at 1 week were more likely to be thinner at 6-weeks (r = .38, P = .010). CONCLUSIONS: The data supports the hypothesis that rotator cuff tendons repaired using the single-row inverted-mattress technique take 6 weeks to heal to bone. Unlike in other tendons, there was no hypertrophic healing response. Prior to 6 weeks, the tendon may stretch/thin-out, particularly if its material properties, as assessed by shear wave elastography, are inferior. The material properties of the tendon improved at the tendon insertion site first, then medially out to 12 months post-repair.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Lesiones del Manguito de los Rotadores , Humanos , Manguito de los Rotadores/diagnóstico por imagen , Manguito de los Rotadores/cirugía , Lesiones del Manguito de los Rotadores/diagnóstico por imagen , Lesiones del Manguito de los Rotadores/cirugía , Tendones , Artroscopía/métodos , Diagnóstico por Imagen de Elasticidad/métodos , Resultado del Tratamiento
8.
HSS J ; 19(1): 44-52, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36776506

RESUMEN

Background: Superior capsule reconstruction (SCR) is an option for the treatment of massive, irreparable rotator cuff tears. However, which materials yield the strongest constructs remains undetermined. Purposes: We sought to investigate whether SCR with polytetrafluoroethylene (PTFE) or human dermal allograft (HDA), 2 or 3 glenoid anchors, and suture or minitape resulted in better failure load properties at the patch-glenoid interface. Methods: We conducted a biomechanical study in 30 glenoid-sided SCR repairs in Sawbones models divided into 5 groups. Each was pulled to failure to assess mode of failure, peak load (N), stiffness (N/mm), yield load (N), peak energy (N m), and ultimate energy (N m). The 5 groups were as follows: group 1-PTFE, 2 anchors, and suture; group 2-PTFE, 2 anchors, and minitape; group 3-HDA, 2 anchors, and suture; group 4-HDA, 2 anchors, and minitape; group 5-PTFE, 3 anchors, and minitape. Results: Repairs failed by button-holing of suture/minitape. Group 5 had greater peak load, stiffness, yield load, and peak energy (384 ± 62 N; 24 ± 3 N/mm; 343 ± 42 N; 4 ± 2 N m) than group 3 (226 ± 67 N; 16 ± 4 N/mm; 194 ± 74 N; 2 ± 1 N m) or group 4 (274 ± 62 N; 17 ± 4 N/mm; 244 ± 50 N; 2 ± 1 N m) and greater ultimate energy (8 ± 3 N m) than all other groups. Conclusions: This biomechanical study of SCR repairs in Sawbones models found that yield load was greater in PTFE than HDA, 3 anchors were better than 2, and minitape was no better than suture.

9.
J Trauma Acute Care Surg ; 94(5): 725-734, 2023 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-36809374

RESUMEN

BACKGROUND: Postinjury multiple organ failure (MOF) is the leading cause of late death in trauma patients. Although MOF was first described 50 years ago, its definition, epidemiology, and change in incidence over time are poorly understood. We aimed to describe the incidence of MOF in the context of different MOF definitions, study inclusion criteria, and its change over time. METHODS: Cochrane Library, EMBASE, MEDLINE, PubMed, and Web of Science databases were searched for articles published between 1977 and 2022 in English and German. Random-effects meta-analysis was performed when applicable. RESULTS: The search returned 11,440 results, of which 842 full-text articles were screened. Multiple organ failure incidence was reported in 284 studies that used 11 unique inclusion criteria and 40 MOF definitions. One hundred six studies published from 1992 to 2022 were included. Weighted MOF incidence by publication year fluctuated from 11% to 56% without significant decrease over time. Multiple organ failure was defined using four scoring systems (Denver, Goris, Marshall, Sequential Organ Failure Assessment [SOFA]) and 10 different cutoff values. Overall, 351,942 trauma patients were included, of whom 82,971 (24%) developed MOF. The weighted incidences of MOF from meta-analysis of 30 eligible studies were as follows: 14.7% (95% confidence interval [CI], 12.1-17.2%) in Denver score >3, 12.7% (95% CI, 9.3-16.1%) in Denver score >3 with blunt injuries only, 28.6% (95% CI, 12-45.1%) in Denver score >8, 25.6% (95% CI, 10.4-40.7%) in Goris score >4, 29.9% (95% CI, 14.9-45%) in Marshall score >5, 20.3% (95% CI, 9.4-31.2%) in Marshall score >5 with blunt injuries only, 38.6% (95% CI, 33-44.3%) in SOFA score >3, 55.1% (95% CI, 49.7-60.5%) in SOFA score >3 with blunt injuries only, and 34.8% (95% CI, 28.7-40.8%) in SOFA score >5. CONCLUSION: The incidence of postinjury MOF varies largely because of lack of a consensus definition and study population. Until an international consensus is reached, further research will be hindered. LEVEL OF EVIDENCE: Systematic Review and Meta-analysis; Level III.


Asunto(s)
Traumatismo Múltiple , Heridas no Penetrantes , Humanos , Adulto , Insuficiencia Multiorgánica/epidemiología , Insuficiencia Multiorgánica/etiología , Incidencia , Traumatismo Múltiple/epidemiología , Traumatismo Múltiple/complicaciones , Puntuaciones en la Disfunción de Órganos , Heridas no Penetrantes/complicaciones
10.
Am J Sports Med ; 51(4): 893-900, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36803077

RESUMEN

BACKGROUND: It is undetermined which factors predict return to work after arthroscopic rotator cuff repair. PURPOSE: To identify which factors predicted return to work at any level and return to preinjury levels of work 6 months after arthroscopic rotator cuff repair. STUDY DESIGN: Case-control study; Level of evidence, 3. METHODS: Multiple logistic regression analysis of prospectively collected descriptive, preinjury, preoperative, and intraoperative data from 1502 consecutive primary arthroscopic rotator cuff repairs, performed by a single surgeon, was performed to identify independent predictors of return to work at 6 months postoperatively. RESULTS: Six months after arthroscopic rotator cuff repair, 76% of patients had returned to work, and 40% had returned to preinjury levels of work. Return to work at 6 months was likely if patients were still working after their injuries but before surgery (Wald statistic [W] = 55, P < .0001), were stronger in internal rotation preoperatively (W = 8, P = .004), had full-thickness tears (W = 9, P = .002), and were female (W = 5, P = .030). Patients who continued working postinjury but presurgery were 1.6 times more likely to return to work at any level at 6 months compared to patients who were not working (P < .0001). Patients who had a less strenuous preinjury level of work (W = 173, P < .0001), worked at a mild to moderate level post injury but presurgery, had greater preoperative behind-the-back lift-off strength (W = 8, P = .004), and had less preoperative passive external rotation range of motion (W = 5, P = .034) were more likely to return to preinjury levels of work at 6 months postoperatively. Specifically, patients who worked at a mild to moderate level postinjury but presurgery were 2.5 times more likely to return to work than patients who were not working, or who were working strenuously postinjury but presurgery (p < 0.0001). Patients who nominated their preinjury level of work as "light" were 11 times more likely to return to preinjury levels of work at 6 months compared to those who nominated it as "strenuous" (P < .0001). CONCLUSION: Six months after rotator cuff repair, patients who continued to work after injury but presurgery were the most likely to return to work at any level, and patients who had less strenuous preinjury levels of work were the most likely to return to their preinjury levels of work. Greater preoperative subscapularis strength independently predicted return to work at any level and to preinjury levels.


Asunto(s)
Lesiones del Manguito de los Rotadores , Manguito de los Rotadores , Humanos , Femenino , Masculino , Manguito de los Rotadores/cirugía , Lesiones del Manguito de los Rotadores/cirugía , Resultado del Tratamiento , Estudios de Casos y Controles , Reinserción al Trabajo , Estudios Retrospectivos , Artroscopía , Rango del Movimiento Articular
11.
ANZ J Surg ; 93(3): 649-655, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36627775

RESUMEN

BACKGROUND: Interposition graft rotator cuff repair is one option for the treatment of massive, otherwise irreparable rotator cuff tears. It is undetermined how different suturing techniques influence morphology at the patch-tendon interface in interposition rotator cuff repairs, particularly with respect to increased cross-sectional area at the repair site post-exposure to cyclic loading, which may influence healing. We aimed to analyze how the morphology of the grafts used in polytetrafluoroethylene (PTFE) interposition rotator cuff repairs differed according to whether the graft was secured using the multiple mattress technique or the weave technique respectively. METHODS: Twelve PTFE interposition rotator cuff repairs (two groups, n = 6) were cyclically loaded. The thickness, width, cross-sectional area at the individual patches and at the repair site, and patch elongation were compared between repairs using the 'multiple mattress' technique and repairs that used the 'weave' technique. RESULTS: At all loads, repair site cross-sectional area and thickness was greater in the weave group than in the multiple mattress group (P<0.05), despite repair site width being greater in the multiple mattress group (P<0.05). No significant differences in elongation were found between the multiple mattress and weave groups. CONCLUSION: Greater repair site cross-sectional area under cyclic loading was observed in polytetrafluoroethylene interposition rotator repairs that used the weave technique than in those that used the multiple mattress technique. Increased repair site cross-sectional area in the weave group occurred due to increased thickness and decreased width relative to the multiple mattress group. No differences in cross-sectional area were found between groups at the individual patches.


Asunto(s)
Lesiones del Manguito de los Rotadores , Manguito de los Rotadores , Humanos , Manguito de los Rotadores/cirugía , Fenómenos Biomecánicos , Lesiones del Manguito de los Rotadores/cirugía , Tendones/cirugía , Técnicas de Sutura , Politetrafluoroetileno
12.
J Clin Orthop Trauma ; 36: 102081, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36479505

RESUMEN

Background: It is undetermined how effective superior capsule/capsular reconstruction (SCR) is, and which factors influence clinical outcomes. Questions/purposes: (1) To identify which factors influence outcomes in SCR, (2) to evaluate the effect of graft integrity on clinical outcomes, and (3) to compare SCR to other procedures for irreparable rotator cuff tears. Methods: PubMed and EMBASE databases were searched for clinical SCR studies. Data on specific factors that influenced outcomes, that compared outcomes between intact/torn graft groups, or compared SCR to alternative treatments for irreparable tears were extracted by two investigators. Random-effects meta-analysis was performed to compare outcomes between intact vs torn SCR grafts. Results: 394 articles were identified. 100 full-text articles were screened. 13 studies were included for scoping review. Eight studies were meta-analyzed. Better clinical scores were found in younger patients, with intact/repairable subscapularis, without acetabulization/arthritis, who played sports. In patients with irreparable tears without arthritis, SCR produced similar clinical scores at 2 years as shoulder arthroplasty and partial infraspinatus repair, and greater improvements in ASES and Constant scores than latissimus dorsi tendon transfer. Intact grafts produced better VAS (mean difference [MD] = 0.97, 95% confidence interval [-1.45-0.50], P < 0.0001, I 2 = 67%, n [patients] = 261), ASES (MD = 8.29, [2.89-13.70], P = 0.003, I 2 = 74%, n = 281), external rotation (MD = 4.49, [0.36-8.61], P = 0.03, I 2 = 0%, n = 240), and acromiohumeral distance (MD = 2.45, [0.96-3.94], P = 0.001, I 2 = 92%, n = 260) than torn grafts. Conclusions: Patients who underwent SCR for irreparable rotator cuff tears were more likely to have better clinical outcomes if they were younger, had intact/repairable subscapularis, without acetabulization/arthritis, played sports and had intact grafts.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...