Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
AJNR Am J Neuroradiol ; 41(7): 1286-1292, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32586963

RESUMEN

BACKGROUND AND PURPOSE: Intra-arterial chemotherapy for retinoblastoma has dramatically altered the natural history of the disease. The remarkable outcomes associated with a high safety profile have pushed the envelope to offer treatment for patients weighing ≤10 kg. The purpose was to determine the efficacy and safety of IAC infusions performed in infants weighing ≤10 kg with intraocular retinoblastoma. MATERIALS AND METHODS: A retrospective chart review was performed for patients diagnosed with retinoblastoma and managed with intra-arterial chemotherapy. RESULTS: The total study cohort included 207 retinoblastoma tumors of 207 eyes in 196 consecutive patients who underwent 658 intra-arterial chemotherapy infusions overall. Of these, patient weights were ≤10 kg in 69 (35.2%) and >10 kg in 127 (64.8%) patients. Comparison (≤10 kg versus >10 kg) revealed that the total number of intra-arterial chemotherapy infusions was 222 versus 436. Periprocedural complications were not significantly different (2 [0.9%] versus 2 [0.5%]; P = .49). Cumulative radiation exposure per eye was significantly lower in infants weighing ≤10 kg (5.0 Gym2 versus 7.7 Gym2; P = .01). Patients weighing ≤10 kg had a greater frequency of complete tumor regression (82.6% versus 60.9%; P = .02). Mean fluoroscopy time was not significantly different (7.5 versus 7.2; P = .71). There was a significant difference in the frequency of enucleation (16 [21.6%] versus 52 [39.1%]; P = .01). Patients weighing ≤10 kg had greater number of aborted procedures (12 [5.4%] versus 7 [1.6%]; P = .01). On multivariate analysis, weight ≤10 kg was not an independent predictor of complications or procedure failure. CONCLUSIONS: Intra-arterial chemotherapy in patients weighing ≤10 kg is a safe and effective treatment.


Asunto(s)
Protocolos de Quimioterapia Combinada Antineoplásica/administración & dosificación , Melfalán/administración & dosificación , Neoplasias de la Retina/tratamiento farmacológico , Retinoblastoma/tratamiento farmacológico , Topotecan/administración & dosificación , Femenino , Humanos , Lactante , Infusiones Intraarteriales , Masculino , Estudios Retrospectivos , Resultado del Tratamiento
2.
J Clin Neurosci ; 58: 20-24, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30454690

RESUMEN

BACKGROUND AND PURPOSE: Flow-diversion therapy (FDT) for large and complex intracranial aneurysms is effective and considered superior to primary coil embolization. Data evaluating common treatment with both FDT and coiling continues to emerge, but information on outcomes remains scarce. This study aims to examine further the efficiency and outcomes correlated with joint FDT using pipeline embolization device (PED) and coiling compared to PED-alone in treating intracranial aneurysms. MATERIALS AND METHODS: Comparative review and analysis of aneurysm treatment with PED in 416 subjects were conducted. Joint modality, PED, and coiling were compared to PED-alone for aneurysm occlusion, recurrence, retreatment, thromboembolic or hemorrhagic events, and functional outcome using the modified Rankin Scale. Data on patient demographics, aneurysm characteristics, clinical and angiographic follow up, were also collected. Both univariate analysis and multivariate logistic regression modeling using mixed-effects were performed. RESULTS: Total of 437 aneurysms were treated using PED of which 74 were managed with both PED and coiling. Average patient-age was 56 years, the majority were men (85%), an average aneurysm size was 9 mm, and the majority were saccular aneurysms (84%). Larger aneurysm size was associated with a poor outcome in patients with unruptured aneurysms (OR = 1.06). Adjusted regression analyses revealed no differences between treatment groups in thromboembolic or hemorrhagic events, aneurysm occlusion rate, residual flow on follow up angiography, or functional outcome. CONCLUSIONS: Treatment of intracranial aneurysms with joint PED and coiling was safe with no increase in complications when compared to PED alone. Aneurysm occlusion rates and functional outcome with PED and coiling stays comparable to treatment with PED-alone.


Asunto(s)
Embolización Terapéutica/métodos , Procedimientos Endovasculares/métodos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/terapia , Stents Metálicos Autoexpandibles , Adulto , Anciano , Angiografía de Substracción Digital/instrumentación , Angiografía de Substracción Digital/métodos , Prótesis Vascular , Embolización Terapéutica/instrumentación , Procedimientos Endovasculares/instrumentación , Femenino , Estudios de Seguimiento , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Inhibidores de Agregación Plaquetaria/administración & dosificación , Retratamiento/instrumentación , Retratamiento/métodos , Estudios Retrospectivos , Resultado del Tratamiento
3.
AJNR Am J Neuroradiol ; 37(5): 849-55, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26611991

RESUMEN

BACKGROUND AND PURPOSE: The use of the Pipeline Embolization Device in the management of recurrent previously stented cerebral aneurysms is controversial. The aim of this study was to evaluate the efficacy and safety of the Pipeline Embolization Device in the treatment of recurrent, previously stented aneurysms. MATERIALS AND METHODS: Twenty-one patients with previously stented recurrent aneurysms who later underwent Pipeline Embolization Device placement (group 1) were retrospectively identified and compared with 63 patients who had treatment with the Pipeline Embolization Device with no prior stent placement (group 2). Occlusion at the latest follow-up angiogram, recurrence and retreatment rates, clinical outcome, complications, and morbidity and mortality observed after treatment with the Pipeline Embolization Device were analyzed. RESULTS: Patient characteristics were similar between the 2 groups. The mean time from stent placement to recurrence was 25 months. Pipeline Embolization Device treatment resulted in complete aneurysm occlusion in 55.6% of patients in group 1 versus 80.4% of patients in group 2 (P = .036). The retreatment rate in group 1 was 11.1% versus 7.1% in group 2 (P = .62). The rate of good clinical outcome at the latest follow-up in group 1 was 81% versus 93.2% in group 2 (P = .1). Complications were observed in 14.3% of patients in group 1 and 9.5% of patients in group 2 (P = .684). CONCLUSIONS: The use of the Pipeline Embolization Device in the management of previously stented aneurysms is less effective than the use of this device in nonstented aneurysms. Prior stent placement can worsen the safety and efficacy profile of this device.


Asunto(s)
Embolización Terapéutica/instrumentación , Aneurisma Intracraneal/terapia , Adulto , Anciano , Angiografía Cerebral , Embolización Terapéutica/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Retratamiento , Estudios Retrospectivos , Stents , Resultado del Tratamiento
4.
AJNR Am J Neuroradiol ; 35(8): 1562-6, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24788125

RESUMEN

BACKGROUND AND PURPOSE: The Pipeline Embolization Device has emerged as an important treatment option for intracranial aneurysms. The number of devices needed to treat an aneurysm is uncertain and is the subject of vigorous debate. The purpose of this study was to compare rates of complications, aneurysm occlusion, and outcome in patients treated with a single-versus-multiple Pipeline Embolization Devices. MATERIAL AND METHODS: One hundred seventy-eight patients were treated with the Pipeline Embolization Device at our institution. Patients were divided into 2 groups: a single-device group (n = 126) and a multiple-device group (n = 52). RESULTS: There was no statistically significant difference between the 2 groups with respect to baseline characteristics except for age and aneurysm size (higher with multiple Pipeline Embolization Devices). Complications occurred more frequently with multiple (15%) versus a single device (5%, P = .03). In multivariate analysis, the use of multiple devices independently predicted complications. A similar proportion of patients achieved adequate aneurysm obliteration at follow-up in the single-device (84%) and the multiple-device groups (87%, P = .8). In multivariate analysis, age and follow-up time predicted obliteration. At follow-up, a significantly higher proportion of patients treated with a single device (97%) achieved a favorable outcome compared with those treated with multiple devices (89%, P = .03). In multivariate analysis, there was a strong trend for the use of a single device to predict favorable outcomes (P = .06). CONCLUSIONS: Treatment with a single Pipeline Embolization Device provides similar occlusion rates with less complications and better overall outcomes. These findings suggest that a single Pipeline Embolization Device is sufficient for treatment of most intracranial aneurysms.


Asunto(s)
Embolización Terapéutica/efectos adversos , Embolización Terapéutica/instrumentación , Aneurisma Intracraneal/terapia , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Resultado del Tratamiento
5.
AJNR Am J Neuroradiol ; 35(3): 546-52, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23945229

RESUMEN

BACKGROUND AND PURPOSE: Large and giant intracranial aneurysms are increasingly treated with endovascular techniques. The goal of this study was to retrospectively analyze the complications and long-term results of coiling in large and giant aneurysms (≥ 10 mm) and identify predictors of outcome. MATERIALS AND METHODS: A total of 334 large or giant aneurysms (≥ 10 mm) were coiled in our institution between 2004 and 2011. Medical charts and imaging studies were reviewed to determine baseline characteristics, procedural complications, and clinical/angiographic outcomes. Aneurysm size was 15 mm on average. Two hundred twenty-five aneurysms were treated with conventional coiling; 88, with stent-assisted coiling; 14, with parent vessel occlusion; and 7, with balloon-assisted coiling. RESULTS: Complications occurred in 10.5% of patients, with 1 death (0.3%). Aneurysm location and ruptured aneurysms predicted complications. Angiographic follow-up was available for 84% of patients at 25.4 months on average. Recanalization and retreatment rates were 39% and 33%, respectively. Larger aneurysm size, increasing follow-up time, conventional coiling, and aneurysm location predicted both recurrence and retreatment. The annual rebleeding rate was 1.9%. Larger aneurysm size, increasing follow-up time, and aneurysm location predicted new or recurrent hemorrhage. Favorable outcomes occurred in 92% of patients. Larger aneurysm size, poor Hunt and Hess grades, and new or recurrent hemorrhage predicted poor outcome. CONCLUSIONS: Coiling of large and giant aneurysms has a reasonable safety profile with good clinical outcomes, but aneurysm reopening remains very common. Stent-assisted coiling has lower recurrence, retreatment, and new or recurrent hemorrhage rates with no additional morbidity compared with conventional coiling. Aneurysm size was a major determinant of recanalization, retreatment, new or recurrent hemorrhage, and poor outcome.


Asunto(s)
Embolización Terapéutica/instrumentación , Procedimientos Endovasculares/instrumentación , Aneurisma Intracraneal/terapia , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Aneurisma Intracraneal/patología , Masculino , Persona de Mediana Edad , Análisis Multivariante , Análisis de Regresión , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
6.
AJNR Am J Neuroradiol ; 34(12): 2326-30, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23811979

RESUMEN

Five patients were found to have spontaneous delayed migration/shortening of their Pipeline Embolization Devices on follow-up angiography. The device migrated proximally in 4 patients and distally in 1 patient. One patient had a subarachnoid hemorrhage and died as a result of migration of the Pipeline Embolization Device, and another patient presented with complete MCA occlusion and was left severely disabled. Mismatch in arterial diameter between inflow and outflow vessels was a constant finding. Migration of the Pipeline Embolization Device was managed conservatively, with additional placement of the device, or with parent vessel occlusion. Obtaining complete expansion of the embolization device by using a longer device, increasing vessel coverage, using adjunctive aneurysm coiling, and avoiding dragging and stretching of the device are important preventive measures. Neurointerventionalists should be aware of this potentially fatal complication and take all necessary preventive measures.


Asunto(s)
Embolización Terapéutica/efectos adversos , Embolización Terapéutica/instrumentación , Migración de Cuerpo Extraño/diagnóstico por imagen , Migración de Cuerpo Extraño/etiología , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/terapia , Stents/efectos adversos , Adulto , Anciano , Diseño de Equipo , Falla de Equipo , Resultado Fatal , Femenino , Humanos , Aneurisma Intracraneal/complicaciones , Masculino , Persona de Mediana Edad , Radiografía , Hemorragia Subaracnoidea/etiología , Hemorragia Subaracnoidea/prevención & control , Insuficiencia del Tratamiento
7.
AJNR Am J Neuroradiol ; 34(10): 1987-92, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23639562

RESUMEN

BACKGROUND AND PURPOSE: Stent-assisted coiling and balloon-assisted coiling are 2 well-established techniques for treatment of wide-neck intracranial aneurysms. A direct comparative analysis of angiographic outcomes with the 2 techniques has not been available. We compare the angiographic outcomes of wide-neck aneurysms treated with stent-assisted coiling versus balloon-assisted coiling. MATERIALS AND METHODS: A retrospective review was conducted on 101 consecutive patients treated at our institution, 69 with stent-assisted coiling and 32 with balloon-assisted coiling. Two multivariate logistic regression analyses were performed to determine predictors of aneurysm obliteration and predictors of progressive aneurysm thrombosis at follow-up. RESULTS: The 2 groups were comparable with respect to all baseline characteristics with the exception of a higher proportion of ruptured aneurysms in the balloon-assisted coiling group (65.6%) than in the stent-assisted coiling group (11.5%, P < .001). Procedural complications did not differ between the stent-assisted coiling group (6%) and the balloon-assisted coiling group (9%, P = .5). The rates of complete aneurysm occlusion (Raymond score 1) at the most recent follow-up were significantly higher for the stent-assisted coiling group (75.4%) compared with the balloon-assisted coiling group (50%, P = .01). Progressive occlusion of incompletely coiled aneurysms was noted in 76.6% of aneurysms in the stent-assisted coiling group versus 42.8% in the balloon-assisted coiling group (P = .02). Retreatment rates were significantly lower with stent-assisted coiling (4.3%) versus balloon-assisted coiling (15.6%, P = .05). In multivariate analysis, stented aneurysms independently predicted both complete aneurysm obliteration and progression of occlusion. CONCLUSIONS: Stent-assisted coiling may yield lower rates of retreatment and higher rates of aneurysm obliteration and progression of occlusion at follow-up than balloon-assisted coiling with a similar morbidity rate.


Asunto(s)
Oclusión con Balón/métodos , Angiografía Cerebral , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/terapia , Stents , Aneurisma Roto/diagnóstico por imagen , Aneurisma Roto/epidemiología , Aneurisma Roto/terapia , Oclusión con Balón/efectos adversos , Oclusión con Balón/instrumentación , Hemorragia Cerebral/epidemiología , Hemorragia Cerebral/etiología , Infarto Cerebral/epidemiología , Infarto Cerebral/etiología , Femenino , Estudios de Seguimiento , Humanos , Aneurisma Intracraneal/epidemiología , Modelos Logísticos , Masculino , Persona de Mediana Edad , Morbilidad , Análisis Multivariante , Valor Predictivo de las Pruebas , Retratamiento , Estudios Retrospectivos , Resultado del Tratamiento
8.
AJNR Am J Neuroradiol ; 34(4): 828-32, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23042929

RESUMEN

BACKGROUND AND PURPOSE: ONP is a well-known presentation of PcomA aneurysms. Reports on recovery of ONP with endovascular coiling have been limited to small case series. We assessed the safety and efficacy of endovascular therapy in a series of PcomA aneurysms with ONP. MATERIALS AND METHODS: We reviewed 37 patients with ONP who underwent endovascular treatment in our institution between 2005 and 2011. Published studies were also reviewed to determine the overall rate of ONP recovery with endovascular therapy. RESULTS: Nineteen patients (51.4%) presented with complete ONP, and 18 (48.6%), with partial ONP. Conventional coiling was performed in 31 (83.8%) patients; stent-assisted coiling, in 4 (10.8%); and balloon remodeling, in 2 (5.4%). There was 1 (2.7%) procedural complication (a transient thromboembolic event). Twenty-seven (73%) patients were treated within 3 days from symptom onset. At the last available clinical follow-up, ONP resolution was complete in 14 (37.8%) patients and partial in 19 (51.4%). Only 4 (10.8%) patients showed no signs of nerve recovery. In multivariate analysis, partial ONP and longer follow-up durations were predictors of complete nerve recovery. Treatment timing, type of endovascular embolization, subarachnoid hemorrhage, and initial degree of aneurysm occlusion were not predictors of nerve recovery. Of 169 patients reported in the literature (including ours), ONP resolved completely in 73 (43.2%) patients and partially in 73 (43.2%). CONCLUSIONS: Endovascular therapy is a safe and highly efficient alternative to surgical clipping for PcomA aneurysms with ONP.


Asunto(s)
Procedimientos Endovasculares/métodos , Aneurisma Intracraneal/complicaciones , Aneurisma Intracraneal/terapia , Enfermedades del Nervio Oculomotor/complicaciones , Recuperación de la Función , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Resultado del Tratamiento
9.
Interv Neuroradiol ; 18(4): 469-83, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23217643

RESUMEN

Intracranial vertebral artery dissection (VAD) represents the underlying etiology in a significant percentage of posterior circulation ischemic strokes and subarachnoid hemorrhages. These lesions are particularly challenging in their diagnosis, management, and in the prediction of long-term outcome. Advances in the understanding of underlying processes leading to dissection, as well as the evolution of modern imaging techniques are discussed. The data pertaining to medical management of intracranial VADs, with emphasis on anticoagulants and antiplatelet agents, is reviewed. Surgical intervention is discussed, including, the selection of operative candidates, open and endovascular procedures, and potential complications. The evolution of endovascular technology and techniques is highlighted.


Asunto(s)
Circulación Cerebrovascular/fisiología , Procedimientos Endovasculares/tendencias , Procedimientos Neuroquirúrgicos/tendencias , Disección de la Arteria Vertebral/fisiopatología , Disección de la Arteria Vertebral/cirugía , Adulto , Isquemia Encefálica/diagnóstico , Isquemia Encefálica/fisiopatología , Isquemia Encefálica/cirugía , Angiografía Cerebral , Niño , Procedimientos Endovasculares/normas , Humanos , Procedimientos Neuroquirúrgicos/normas , Stents , Disección de la Arteria Vertebral/diagnóstico
10.
AJNR Am J Neuroradiol ; 33(8): 1502-6, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22403776

RESUMEN

BACKGROUND AND PURPOSE: Given the challenges posed by surgical clipping, endovascular techniques have been increasingly used to treat SHA aneurysms. The purpose of this study was to assess the safety and efficacy of endovascular techniques in the treatment of SHA aneurysms. MATERIALS AND METHODS: Medical charts and initial and follow-up angiograms were reviewed retrospectively for all patients treated with endovascular procedures at our institution between January 2006 and February 2011. RESULTS: We identified 87 patients with SHA aneurysms who were treated with endovascular techniques. Of these patients, 79 were women and only 8 were men (90.8% female predominance). Thirty-five patients were treated with coil embolization; 45, with stent-assisted coiling; 4, with balloon-assisted coil embolization; and 3, with a flow-diversion technique. Minor complications occurred in 2 patients (2.2%). None of the patients had a major complication. The mortality and permanent morbidity rates related to the procedure were 0%. Imaging follow-up was available for 89.4% of patients (DSA in 65, MRA in 11 patients) at a mean time point of 10.4 months (range, 6-60 months). Of the 76 patients with available follow-up, 3 patients had a recurrence (3.9%) and only 1 required further intervention (1.3%). Stent-assisted coiling was associated with lower recurrence rates than simple coil embolization. CONCLUSIONS: SHA aneurysms have the lowest recurrence rate with endovascular treatment compared with aneurysms in other locations by using historical data. Because of its safety and efficacy, endovascular therapy should be considered the procedure of choice for the treatment of SHA aneurysms.


Asunto(s)
Procedimientos Endovasculares , Aneurisma Intracraneal/terapia , Adulto , Anciano , Embolización Terapéutica , Procedimientos Endovasculares/efectos adversos , Femenino , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Hipófisis/irrigación sanguínea , Radiografía , Recurrencia , Stents
11.
J Comp Neurol ; 466(4): 445-56, 2003 Nov 24.
Artículo en Inglés | MEDLINE | ID: mdl-14566941

RESUMEN

Recent evidence suggests that certain stressors release both endogenous opioids and corticotropin-releasing factor (CRF) to modulate activity of the locus coeruleus (LC)-norepinephrine (NE) system. In ultrastructural studies, axon terminals containing methionine(5)-enkephalin (ENK) or CRF have been shown to target LC dendrites. These findings suggested the hypothesis that both neuropeptides may coexist in common axon terminals that are positioned to have an impact on the LC. This possibility was examined by using immunofluorescence and immunoelectron microscopic analysis of the rat LC and neighboring dorsal pontine tegmentum. Ultrastructural analysis indicated that CRF- and ENK-containing axon terminals were abundant in similar portions of the neuropil and that approximately 16% of the axon terminals containing ENK were also immunoreactive for CRF. Dually labeled terminals were more frequently encountered in the "core" of the LC vs. its extranuclear dendritic zone, which included the medial parabrachial nucleus (mPB). Triple labeling for ENK, CRF, and tyrosine hydroxylase (TH) showed convergence of opioid and CRF axon terminals with noradrenergic dendrites as well as evidence for inputs to TH-labeled dendrites from dually labeled opioid/CRF axon terminals. One potential source of ENK and CRF in the dorsal pons is the central nucleus of the amygdala (CNA). To determine the relative contribution of ENK and CRF terminals from the CNA, the CNA was electrolytically lesioned. Light-level densitometry revealed robust decreases in CRF immunoreactivity in the LC and mPB on the side ipsilateral to the lesion but little or no change in ENK immunoreactivity, confirming previous studies of the mPB. Degenerating terminals from the CNA in lesioned rats were found to be in direct contact with TH-labeled dendrites. Together, these data indicate that ENK and CRF may be colocalized to a subset of individual axon terminals in the LC "core." The finding that the CNA provides, to dendrites in the area examined, a robust CRF innervation, but little or no opioid innervation, suggests that ENK and CRF axon terminals impacting LC neurons originate from distinct sources and that terminals that colocalize ENK and CRF are not from the CNA.


Asunto(s)
Hormona Liberadora de Corticotropina/metabolismo , Locus Coeruleus/fisiología , Péptidos Opioides/metabolismo , Puente/fisiología , Terminales Presinápticos/fisiología , Amígdala del Cerebelo/citología , Amígdala del Cerebelo/lesiones , Amígdala del Cerebelo/fisiología , Amígdala del Cerebelo/ultraestructura , Animales , Técnica del Anticuerpo Fluorescente , Lateralidad Funcional , Locus Coeruleus/citología , Locus Coeruleus/ultraestructura , Masculino , Microscopía Inmunoelectrónica , Vías Nerviosas/fisiología , Puente/citología , Puente/ultraestructura , Terminales Presinápticos/ultraestructura , Ratas , Ratas Sprague-Dawley
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...