A CMOS-based neural interface device equipped with an integrated micro light source array for optogenetics was fabricated and demonstrated. A GaInN LED array formed on sapphire substrate was successfully assembled with a multifunctional CMOS image sensor that is capable of on-chip current injection. We demonstrated a functionality of light stimulation onto ChR2-expressed cells in an in vitro experiment. A ChR2-expressed cell were successfully stimulated with the light emitted from the fabricated device.


Asunto(s)
Electrónica/instrumentación , Metales/química , Neuronas/fisiología , Optogenética/instrumentación , Óxidos/química , Semiconductores , Animales , Línea Celular Tumoral , Channelrhodopsins , Diseño de Equipo , Activación del Canal Iónico/efectos de la radiación , Luz , Ratones , Neuronas/efectos de la radiación
3.
Neuroradiol J ; 26(1): 41-6, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23859166

RESUMEN

This study aimed to elucidate the incidence and distribution of the cortical retention of Pittsburgh compound B (PIB) in patients with idiopathic normal pressure hydrocephalus (iNPH) and clarify the differences from those in patients with Alzheimer's disease (AD). Ten patients with iNPH without any clinical signs indicative of AD were enrolled in this study. Cerebral retention of PIB in positron emission tomography (PET) in iNPH patients was compared with those in seven age-matched AD patients. The CSF levels of ß-amyloid 1-42 peptide (Aß42), which inversely decrease with cerebral amyloid burden, were also measured. Three of the ten patients with iNPH showed increased cortical PIB retention. Although the mean cortical SUV ratios were similar, the distribution of PIB retention differed widely between the patients with iNPH and AD. PIB retention was limited to the high-convexity parasagittal areas in iNPH patients, whereas it spread over the frontal and parietotemporal areas in AD. The coronal images of PIB-PET were more informative than conventional transverse images in evaluating the distribution pattern of cortical PIB retention. Two iNPH patients with higher cortical PIB retention had the lowest levels of CSF Aß42, indicating that PIB retention in iNPH would not reflect a simple delay in PIB clearance but its binding to existing Aß amyloid in the brain. Our results indicate that iNPH is one of the diseases exhibiting cortical PIB retention. The characteristic distribution of PIB retention in iNPH could be useful in the differential diagnosis between iNPH and AD.


Asunto(s)
Enfermedad de Alzheimer/patología , Péptidos beta-Amiloides/líquido cefalorraquídeo , Hidrocéfalo Normotenso/patología , Fragmentos de Péptidos/líquido cefalorraquídeo , Anciano , Anciano de 80 o más Años , Enfermedad de Alzheimer/líquido cefalorraquídeo , Enfermedad de Alzheimer/diagnóstico por imagen , Compuestos de Anilina , Encéfalo/diagnóstico por imagen , Mapeo Encefálico , Femenino , Lateralidad Funcional , Humanos , Hidrocéfalo Normotenso/líquido cefalorraquídeo , Hidrocéfalo Normotenso/diagnóstico por imagen , Masculino , Tomografía de Emisión de Positrones , Estadísticas no Paramétricas , Tiazoles
4.
Artículo en Inglés | MEDLINE | ID: mdl-23367087

RESUMEN

A novel CMOS-based neural interface device equipped with an integrated micro light source array was proposed and demonstrated. Target application of the device is optogenetics. GaInN LED array formed on sapphire substrate was successfully assembled with a multifunctional CMOS image sensor which is capable of injecting current via any of the pixel. We demonstrated addressable LED operation with the present device. The device has advantages such as simultaneous multi-site stimulation and on-chip optical imaging, that are not available with previously reported LED array device for optogenetics.


Asunto(s)
Iluminación/instrumentación , Neuronas/fisiología , Optogenética/instrumentación , Estimulación Luminosa/instrumentación , Semiconductores , Procesamiento de Señales Asistido por Computador/instrumentación , Imagen de Colorante Sensible al Voltaje/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Integración de Sistemas
5.
Artículo en Inglés | MEDLINE | ID: mdl-22255884

RESUMEN

A CMOS-based flexible retinal stimulator equipped with bullet-shaped bulk Pt electrodes was fabricated and demonstrated. We designed a new CMOS unit chip with an on-chip stimulator, single- and multi-site stimulation modes, and monitoring functions. We have developed a new structure and packaging process of flexible retinal stimulator with bullet-type bulk Pt electrode. We have confirmed the retinal stimulation functionality in an in vivo stimulation trial on rabbit's retina.


Asunto(s)
Terapia por Estimulación Eléctrica/instrumentación , Electrodos Implantados , Platino (Metal)/química , Procesamiento de Señales Asistido por Computador/instrumentación , Prótesis Visuales , Animales , Simulación por Computador , Electrodos , Diseño de Equipo , Modelos Anatómicos , Conejos , Retina/patología , Retina/fisiología
6.
Artículo en Inglés | MEDLINE | ID: mdl-21096930

RESUMEN

We developed a novel CMOS-based multichip flexible neural stimulator with on-chip stimulation generator. It enables simultaneous multi-site stimulation. We also propose a new type of multi-chip retinal stimulator with single electrode / unit chip configuration. We successfully performed simultaneous multi-site stimulation in an in vivo retinal stimulation experiment using a rabbit.


Asunto(s)
Estimulación Eléctrica/instrumentación , Metales/química , Óxidos/química , Docilidad , Semiconductores , Animales , Tampones (Química) , Electricidad , Potenciales Evocados Visuales/fisiología , Conejos , Retina/fisiología
7.
Neurology ; 75(20): 1766-72, 2010 Nov 16.
Artículo en Inglés | MEDLINE | ID: mdl-20962290

RESUMEN

BACKGROUND: To date, there is no accepted clinical diagnostic test for Parkinson disease (PD) that is based on biochemical analysis of blood or CSF. The discovery of mutations in the SNCA gene encoding α-synuclein in familial parkinsonism and the accumulation of α-synuclein in the PD brain suggested a critical role for this protein in PD etiology. METHODS: We investigated total and α-synuclein oligomers levels in CSF from patients clinically diagnosed with PD, progressive supranuclear palsy (PSP), or Alzheimer disease (AD), and age-matched controls, using ELISA developed in our laboratory. RESULTS: The levels of α-synuclein oligomers and oligomers/total-α-synuclein ratio in CSF were higher in the PD group (n = 32; p < 0.0001, Mann-Whitney U test) compared to the control group (n = 28). The area under the receiver operating characteristic curve (AUC) indicated a sensitivity of 75.0% and a specificity of 87.5%, with an AUC of 0.859 for increased CSF α-synuclein oligomers in clinically diagnosed PD cases. However, when the CSF oligomers/total-α-synuclein ratio was analyzed, it provided an even greater sensitivity of 89.3% and specificity of 90.6%, with an AUC of 0.948. In another cross-sectional pilot study, we confirmed that the levels of CSF α-synuclein oligomers were higher in patients with PD (n = 25) compared to patients with PSP (n = 18; p < 0.05) or AD (n = 35; p < 0.001) or control subjects (n = 43; p < 0.05). CONCLUSION: Our results demonstrate that levels of α-synuclein oligomers in CSF and the oligomers/total-α-synuclein ratio can be useful biomarkers for diagnosis and early detection of PD.


Asunto(s)
Enfermedad de Parkinson/líquido cefalorraquídeo , Enfermedad de Parkinson/diagnóstico , alfa-Sinucleína/líquido cefalorraquídeo , Adulto , Anciano , Anciano de 80 o más Años , Enfermedad de Alzheimer/líquido cefalorraquídeo , Enfermedad de Alzheimer/diagnóstico , Enfermedad de Alzheimer/metabolismo , Biomarcadores/líquido cefalorraquídeo , Biomarcadores/química , Química Encefálica , Estudios de Cohortes , Estudios Transversales/métodos , Ensayo de Inmunoadsorción Enzimática , Femenino , Humanos , Masculino , Persona de Mediana Edad , Enfermedad de Parkinson/metabolismo , Proyectos Piloto , Parálisis Supranuclear Progresiva/líquido cefalorraquídeo , Parálisis Supranuclear Progresiva/diagnóstico , Parálisis Supranuclear Progresiva/metabolismo , Regulación hacia Arriba/fisiología , alfa-Sinucleína/química
8.
Eur J Neurol ; 17(6): 823-9, 2010 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-20158508

RESUMEN

BACKGROUND AND PURPOSE: The present study aims to clarify the clinical features of non-hypertensive cerebral amyloid angiopathy-related lobar intracerebral hemorrhage (CAA-L-ICH). METHODS: We investigated clinical, laboratory, and neuroimaging findings in 41 patients (30, women; 11, men) with pathologically supported CAA-L-ICH from 303 non-hypertensive Japanese patients aged >OR=55, identified via a nationwide survey as symptomatic CAA-L-ICH. RESULTS: The mean age of patients at onset of CAA-L-ICH was 73.2 +/- 7.4 years; the number of patients increased with age. The corrected female-to-male ratio for the population was 2.2, with significant female predominance. At onset, 7.3% of patients received anti-platelet therapy. In brain imaging studies, the actual frequency of CAA-L-ICHs was higher in the frontal and parietal lobes; however, after correcting for the estimated cortical volume, the parietal lobe was found to be the most frequently affected. CAA-L-ICH recurred in 31.7% of patients during the average 35.3-month follow-up period. The mean interval between intracerebral hemorrhages (ICHs) was 11.3 months. The case fatality rate was 12.2% at 1 month and 19.5% at 12 months after initial ICH. In 97.1% of patients, neurosurgical procedures were performed without uncontrollable intraoperative or post-operative hemorrhage. CONCLUSIONS: Our study revealed the clinical features of non-hypertensive CAA-L-ICH, including its parietal predilection, which will require further study with a larger number of patients with different ethnic backgrounds.


Asunto(s)
Angiopatía Amiloide Cerebral/patología , Hemorragia Cerebral/patología , Distribución por Edad , Edad de Inicio , Anciano , Anciano de 80 o más Años , Angiopatía Amiloide Cerebral/complicaciones , Hemorragia Cerebral/etiología , Femenino , Humanos , Masculino , Persona de Mediana Edad
9.
IEEE Trans Biomed Circuits Syst ; 4(6): 445-53, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23853382

RESUMEN

A complementary metal-oxide semiconductor (CMOS)-based multichip flexible neural stimulator for retinal prostheses was developed. The multichip retinal stimulator is capable of simultaneous multisite stimulation. An on-chip stimulation generator was implemented on the "unit chip," which is the core device of the multichip retinal stimulator. The performance of the CMOS circuitry was characterized. A new device structure and packaging process was developed. The in vivo retinal stimulation on a rabbit's retina was successfully performed and the multisite stimulation functionality was confirmed.

10.
Artículo en Inglés | MEDLINE | ID: mdl-19964235

RESUMEN

We implemented a light-sensing function on CMOS-based multi-chip stimulator for retinal prosthesis. Using the light-sensing circuitry attached to each stimulation electrode, the flexible multi-chip stimulator is capable of image-based patterned stimulation. We verified the function of the light-controlled decision based on the light intensity measured just beside the stimulation site. We also experimentally demonstrated in vivo retinal stimulation on rabbit's retina with light-controlled decision. The result of the present work is a simplified demonstration for the concept of retinal prosthesis with on-site imaging.


Asunto(s)
Terapia por Estimulación Eléctrica/instrumentación , Electrodos Implantados , Interpretación de Imagen Asistida por Computador/instrumentación , Estimulación Luminosa/instrumentación , Prótesis e Implantes , Retina/fisiología , Procesamiento de Señales Asistido por Computador/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Luz , Semiconductores
12.
Acta Radiol ; 50(4): 355-9, 2009 May.
Artículo en Inglés | MEDLINE | ID: mdl-19306137

RESUMEN

BACKGROUND: Although metallic stents are characterized by strong expanse of force, thin walls, and easy stent deployment, their removal from the body is usually difficult or impossible due to the difficulty of unraveling their mesh structure. A stent built of a composite material comprising a metallic wire and a polylactic acid (PLA) fiber, in which the metallic wire component could be unraveled after PLA fiber degradation in the body, should allow easy stent removal. PURPOSE: To evaluate the mechanical strength and retrievability of a composite material stent comprising a metallic wire and a PLA fiber. MATERIAL AND METHODS: We produced a composite material stent comprising a metallic wire and a biodegradable fiber (hybrid stent). As the metallic wire is not cross-linked with itself, but with the PLA fibers only, the hybrid stent can be easily unraveled after PLA fiber degradation. This stent was built with a 0.2-mm stainless-steel wire and a 0.23-mm PLA fiber knitted in the same textile as an Ultraflex stent. For comparison, an identical stent was built using PLA fiber only (PLA stent). The mechanical strength of these stents was tested by the radial expansive force response against circumferential shrinkage stress load. Change in radial force due to PLA fiber degradation was estimated by adding an artificial PLA degeneration process, by immersing each stent in a water bath at 80 degrees C for 48 hours. Retrievability of the hybrid stent after PLA degeneration was examined by hooking and pulling out the residual stainless-steel wire from a silicon tube. RESULTS: The hybrid stent exhibited a linear response in radial expansive force within the range of 15% diameter reduction. The PLA stent did not exhibit linear response at over 15% diameter reduction. Decrease of radial expansive force after PLA degradation was within 5% of the original force in the hybrid stent, but the PLA stent did not create effective radial expansive force. Hybrid stents, even after PLA degradation, exhibited a linear response in radial expansive force, within the range of 15% diameter reduction. The metallic component of the heat-processed hybrid stent was easily unraveled by pulling out the wire. CONCLUSION: The hybrid stent comprising a stainless-steel wire and a PLA fiber appears to provide effective radial expansive force and retrievability.


Asunto(s)
Remoción de Dispositivos , Ácido Láctico , Ensayo de Materiales , Polímeros , Acero Inoxidable , Stents , Implantes Absorbibles , Materiales Biocompatibles , Poliésteres , Estrés Mecánico
13.
IEEE Trans Biomed Circuits Syst ; 3(5): 259-66, 2009 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23853264

RESUMEN

This paper proposes and demonstrates a polarization-analyzing CMOS sensor based on image sensor architecture. The sensor was designed targeting applications for chiral analysis in a microchemistry system. The sensor features a monolithically embedded polarizer. Embedded polarizers with different angles were implemented to realize a real-time absolute measurement of the incident polarization angle. Although the pixel-level performance was confirmed to be limited, estimation schemes based on the variation of the polarizer angle provided a promising performance for real-time polarization measurements. An estimation scheme using 180 pixels in a 1deg step provided an estimation accuracy of 0.04deg. Polarimetric measurements of chiral solutions were also successfully performed to demonstrate the applicability of the sensor to optical chiral analysis.

14.
Br J Radiol ; 82(975): 249-53, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19029223

RESUMEN

The aim of this study was to investigate the appearance of microbubbles during radiofrequency ablation (RFA) of lung tumours. Eight consecutive patients (mean age, 73.1 years; 3 men and 5 women; 10 malignant lesions; mean lesion size, 24.8 mm) who underwent RFA of lung tumours using internally cooled single electrodes were enrolled. During the RFA procedure, the right internal carotid artery was continuously monitored by duplex ultrasound. High-intensity transient signals (HITS) that occurred in the Doppler blood flow waveform were taken to indicate microbubbles. 21 RFA applications were performed for the 10 lesions. HITS were observed in 19 of 21 RFA applications; the mean frequency in a single application was 10+/-13.3. A statistical correlation was seen between the duration of energy deposition and the number of HITS, and between tumour size and the number of HITS. Microbubbles were detected in all patients in the late phase of the first session of RFA.


Asunto(s)
Arterias Carótidas/diagnóstico por imagen , Ablación por Catéter/efectos adversos , Embolia Intracraneal/etiología , Neoplasias Pulmonares/cirugía , Microburbujas/efectos adversos , Anciano , Anciano de 80 o más Años , Electrodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Intraoperatorio , Estudios Prospectivos , Ultrasonografía Doppler Dúplex/métodos
15.
Acta Radiol ; 49(6): 638-43, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-18568555

RESUMEN

BACKGROUND: Percutaneous vertebroplasty (PVP) improves back pain and corrects spinal misalignment to some extent, and thus may improve respiratory function. PURPOSE: To retrospectively investigate changes in respiratory function after PVP. MATERIAL AND METHODS: 41 patients (mean age 72.0 years, range 59-86 years; 39 women, two men) who had undergone PVP for vertebral compression fractures (37 thoracic vertebral bodies [Th6-Th12] and 50 lumbar vertebral bodies [L1-L5]) caused by osteoporosis visited our hospital for follow-up consultation between January and June 2005. At this follow-up consultation, respiratory function testing, including percent forced vital capacity (FVC%) and percent forced expiratory volume in 1 s (FEV(1)%), was performed. We retrospectively compared these values with those taken before PVP using a Wilcoxon signed-rank test. RESULTS: FVC% was 85.2+/-30.3% before PVP and 91.5+/-16.8% at follow-up (mean 10 months after PVP), which represented a significant difference (P<0.003). No significant difference in FEV(1)% was detected. Regarding the number of treatment levels, that is, single vertebroplasty versus multiple vertebroplasty, no significant difference in improvement of FVC% was confirmed (P=0.1). FVC% was abnormally low (

Asunto(s)
Fracturas por Compresión/cirugía , Vértebras Lumbares/cirugía , Enfermedades Pulmonares/prevención & control , Vértebras Torácicas/cirugía , Vertebroplastia/métodos , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Fijación Interna de Fracturas/métodos , Fracturas por Compresión/etiología , Humanos , Masculino , Persona de Mediana Edad , Osteoporosis/complicaciones , Pruebas de Función Respiratoria , Estudios Retrospectivos , Resultado del Tratamiento
16.
Artículo en Inglés | MEDLINE | ID: mdl-19163641

RESUMEN

Multi-finger structure was proposed to improve flexibility of the CMOS LSI-based multi-chip retinal stimulator. A dual-finger retinal stimulator was fabricated and its functionality was demonstrated in retinal stimulation experiments on rabbit's retina, We also proposed an idea of pulsed-powering operation scheme for the multi-chip flexible retinal stimulator. We compared the pulsed-powering scheme with conventional one in a simulation, and show that the pulsed-powering can be an alternative operation scheme for the neural stimulator that provides an improved safety to the biological tissue.


Asunto(s)
Terapia por Estimulación Eléctrica/instrumentación , Estimulación Eléctrica/instrumentación , Potenciales Evocados Visuales/fisiología , Retina/fisiología , Terapia Asistida por Computador/instrumentación , Corteza Visual/fisiología , Algoritmos , Animales , Umbral Diferencial , Estimulación Eléctrica/métodos , Terapia por Estimulación Eléctrica/métodos , Diseño de Equipo , Prótesis e Implantes , Conejos , Retina/anatomía & histología , Semiconductores , Procesamiento de Señales Asistido por Computador/instrumentación , Programas Informáticos , Terapia Asistida por Computador/métodos
17.
Artículo en Inglés | MEDLINE | ID: mdl-18003329

RESUMEN

We have performed in vivo electric stimulation experiments on rabbit retina to demonstrate feasibility of CMOS LSI-based multi-chip flexible neural stimulator for retinal prosthesis. We have developed new packaging structure with an improved flexibility and device control system which totally controls the LSI-based multi-chip stimulator, counter electrode, and stimulation generator. We have implanted the fabricated multi-chip stimulator into sclera pocket for STS (Suprachoroidal Transretinal Stimulation) configuration. We successfully obtained EEP (Electrically Evoked Potential) on visual cortex evoked by the multi-chip stimulator.


Asunto(s)
Terapia por Estimulación Eléctrica/instrumentación , Estimulación Eléctrica/instrumentación , Potenciales Evocados Visuales/fisiología , Prótesis e Implantes , Células Ganglionares de la Retina/fisiología , Terapia Asistida por Computador/instrumentación , Corteza Visual/fisiología , Animales , Umbral Diferencial , Estimulación Eléctrica/métodos , Terapia por Estimulación Eléctrica/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Conejos , Valores de Referencia , Semiconductores , Procesamiento de Señales Asistido por Computador/instrumentación , Terapia Asistida por Computador/métodos
18.
J Neural Eng ; 4(1): S85-91, 2007 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-17325420

RESUMEN

This paper describes the technological developments underlying the realization of a reliable and reproducible microchip-based stimulator with a large number of stimulus electrodes. A microchip-based stimulator with over 500 electrodes for suprachoroidal transretinal stimulation (STS) is proposed in this paper, and an example is presented. To enhance reliability and reproducibility for such a large array, we introduce a flip-chip bonding technique and place microchips on the reverse side of a substrate. A square microchip of size 600 microm was fabricated using 0.35 microm standard CMOS process technology. Twelve microchips were flip-chip bonded on a polyimide substrate through Au bumps. To evaluate the feasibility of the proposed device, we successfully fabricated a stimulator with 12 microchips and 118 electrodes made of Pt/Au bumps, and demonstrated their operation in a saline solution for 2 weeks. Also, to evaluate the device operation in vivo, a stimulator with one active IrO(x) electrode was implanted into the scleral pocket of a rabbit and electrical evoked potential (EEP) signals with a threshold of 100 microA were obtained. We also fabricated a simulator with 64 microchips that has 576 electrodes (9 electrodes in a microchip times 64 microchips).


Asunto(s)
Potenciales de Acción/fisiología , Coroides/fisiología , Terapia por Estimulación Eléctrica/instrumentación , Electrónica Médica/instrumentación , Células Ganglionares de la Retina/fisiología , Terapia Asistida por Computador/instrumentación , Animales , Coroides/cirugía , Terapia por Estimulación Eléctrica/métodos , Electrónica Médica/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Miniaturización , Conejos , Retina/fisiología , Retina/cirugía , Enfermedades de la Retina/rehabilitación , Terapia Asistida por Computador/métodos
19.
Am J Transplant ; 7(1): 235-42, 2007 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-17061984

RESUMEN

To elucidate whether progressive wild-type transthyretin (TTR) deposition can actually occur after liver transplantation (LT), amyloid fibrils were investigated in two familial amyloid polyneuropathy patients with TTR Val30Leu variant, who died 1 year after LT. Amyloid fibrils were extracted from cardiac muscles, sciatic nerves and kidney, which were investigated by the immunoprecipitation-mass spectrometry method and liquid chromatography-ion trap mass spectrometry analysis. The ratio of wild-type to variant TTR in cardiac muscle was approximately 5:5 before LT, but greatly increased to about 9:1 after transplantation. The ratios in sciatic nerves and kidney obtained at autopsy were approximately 5:5. Wild-type TTR was undetectable in kidney amyloid obtained before LT. Our results indicate that paradoxical wild-type TTR deposition after LT can preferentially occur in myocardium, leading to fatal cardiac dysfunction, but it is quite likely that this phenomenon can also occur in other visceral organs.


Asunto(s)
Miocardio/metabolismo , Prealbúmina/metabolismo , Neuropatías Amiloides Familiares , Femenino , Humanos , Trasplante de Hígado , Persona de Mediana Edad
20.
Conf Proc IEEE Eng Med Biol Soc ; 2006: 2920-3, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-17946150

RESUMEN

In the present work, we designed a multi-chip-architecture based flexible neural stimulation device for retinal prosthesis. Based on the multi-chip architecture, a novel CMOS stimulation device was successfully designed and characterized. A packaging technique for thin, flexible neural stimulation device was also proposed and demonstrated. Flip-chip bonding technology plays an essential role in the fabrication of the present thin and flexible neural stimulation device.


Asunto(s)
Diseño de Prótesis , Retina , Animales , Ingeniería Biomédica , Estimulación Eléctrica , Electrodos Implantados , Humanos , Sistemas Hombre-Máquina , Retina/fisiología