Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
J Cereb Blood Flow Metab ; 44(6): 1024-1038, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38112197

RESUMEN

Perinatal hypoxic-ischaemic encephalopathy (HIE) is the leading cause of irreversible brain damage resulting in serious neurological dysfunction among neonates. We evaluated the feasibility of positron emission tomography (PET) methodology with 15O-labelled gases without intravenous or tracheal cannulation for assessing temporal changes in cerebral blood flow (CBF) and cerebral metabolic rate for oxygen (CMRO2) in a neonatal HIE rat model. Sequential PET scans with spontaneous inhalation of 15O-gases mixed with isoflurane were performed over 14 days after the hypoxic-ischaemic insult in HIE pups and age-matched controls. CBF and CMRO2 in the injured hemispheres of HIE pups remarkably decreased 2 days after the insult, gradually recovering over 14 days in line with their increase found in healthy controls according to their natural maturation process. The magnitude of hemispheric tissue loss histologically measured after the last PET scan was significantly correlated with the decreases in CBF and CMRO2.This fully non-invasive imaging strategy may be useful for monitoring damage progression in neonatal HIE and for evaluating potential therapeutic outcomes.


Asunto(s)
Animales Recién Nacidos , Circulación Cerebrovascular , Modelos Animales de Enfermedad , Hipoxia-Isquemia Encefálica , Radioisótopos de Oxígeno , Tomografía de Emisión de Positrones , Animales , Tomografía de Emisión de Positrones/métodos , Hipoxia-Isquemia Encefálica/metabolismo , Hipoxia-Isquemia Encefálica/diagnóstico por imagen , Ratas , Encéfalo/metabolismo , Encéfalo/diagnóstico por imagen , Oxígeno/metabolismo , Ratas Sprague-Dawley
2.
Eur J Nucl Med Mol Imaging ; 50(2): 613-621, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36161511

RESUMEN

PURPOSE: Short-term androgen deprivation therapy (ADT) is known to increase heterogeneously prostate-specific membrane antigen (PSMA) expression. This phenomenon might indicate the potential of cancer lesions to respond to ADT. In this prospective study, we evaluated the flare on [18F]PSMA-1007 PET/CT after ADT in metastatic prostate cancer (PCa). Given that aggressive PCa tends to display FDG uptake, we particularly investigated whether the changes in PSMA uptake might correlate with glucose metabolism. METHODS: Twenty-five men with newly diagnosed treatment-naïve metastatic PCa were enrolled in this prospective registered clinical trial. All the patients underwent [18F]PSMA-1007 PET/CT immediately before and 3-4 weeks after ADT initiation (degarelix). Before ADT, [18F]FDG PET/CT was also performed. Standardized uptake values (SUV)max of primary and metastatic lesions were calculated in all PET scans. Serum PSA and testosterone blood samples were collected before the two PSMA PET scans. The changes in PSMA uptake after ADT were represented as ΔSUVmax. RESULTS: All the patients reached castration levels of testosterone at the time of the second [18F]PSMA-1007 PET/CT. Overall, 57 prostate, 314 lymph nodes (LN), and 406 bone lesions were analyzed. After ADT, 104 (26%) bone, 33 (11%) LN, and 6 (11%) prostate lesions showed an increase (≥ 20%) in PSMA uptake, with a median ΔSUVmax of + 50%, + 60%, and + 45%, respectively. Among the lesions detected at the baseline [18F]PSMA-1007 PET/CT, 63% bone and 46% LN were FDG-positive. In these metastases, a negative correlation was observed between the PSMA ΔSUVmax and FDG SUVmax (p < 0.0001). Moreover, a negative correlation between the ΔSUVmax and the decrease in serum PSA after ADT was noted (p < 0.0001). CONCLUSIONS: A heterogeneous increase in PSMA uptake after ADT was detected, most evidently in bone metastases. We observed a negative correlation between the PSMA flare and the intensity of glucose uptake as well as the decrease of serum PSA, suggesting that lesions presenting with such flare might potentially be less aggressive. TRIAL REGISTRATION: NCT03876912, registered 15 March 2019.


Asunto(s)
Neoplasias de la Próstata , Masculino , Humanos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/tratamiento farmacológico , Tomografía Computarizada por Tomografía de Emisión de Positrones , Andrógenos/metabolismo , Antagonistas de Andrógenos/uso terapéutico , Antígeno Prostático Específico/metabolismo , Estudios Prospectivos , Fluorodesoxiglucosa F18 , Testosterona/uso terapéutico , Radioisótopos de Galio
3.
J Nucl Med ; 64(4): 555-560, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36302655

RESUMEN

Bexmarilimab is a new humanized monoclonal antibody against common lymphatic endothelial and vascular endothelial receptor-1 (CLEVER-1) and is in clinical trials for macrophage-guided cancer immunotherapy. In addition being associated with cancer, CLEVER-1 is also associated with fibrosis. To facilitate prospective human PET studies, we preclinically evaluated 89Zr-labeled bexmarilimab in rabbits. Methods: Bexmarilimab was conjugated with desferrioxamine (DFO) and radiolabeled with 89Zr. Retained immunoreactivity was confirmed by flow cytometry. The distribution kinetics of intravenously administered 89Zr-DFO-bexmarilimab (0.1 mg/kg) were determined for up to 7 d in a rabbit model of renal fibrosis mediated by unilateral ureteric obstruction. The in vivo stability of 89Zr-DFO-bexmarilimab was evaluated by sodium dodecyl sulfate-polyacrylamide gel electrophoresis in combination with autoradiography. Additionally, we estimated the human radiation dose from data obtained in healthy rabbits. Results: 89Zr-DFO-bexmarilimab cleared rapidly from the blood circulation and distributed to the liver and spleen. At 24 h after injection, PET/CT, ex vivo γ-counting, and autoradiography demonstrated that there was significantly higher 89Zr-DFO-bexmarilimab uptake in unilateral ureteric obstruction-operated fibrotic renal cortex, characterized by abundant CLEVER-1-positive cells, than in contralateral or healthy kidneys. The estimated effective dose for a 70-kg human was 0.70 mSv/MBq. Conclusion: The characteristics of 89Zr-DFO-bexmarilimab support future human PET studies to, for example, stratify patients for bexmarilimab treatment, evaluate the efficacy of treatment, or monitor disease progression.


Asunto(s)
Enfermedades Renales , Neoplasias , Animales , Humanos , Conejos , Anticuerpos Monoclonales/uso terapéutico , Línea Celular Tumoral , Deferoxamina , Fibrosis , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Tomografía de Emisión de Positrones/métodos , Estudios Prospectivos , Radioisótopos/uso terapéutico , Circonio/uso terapéutico , Moléculas de Adhesión Celular Neuronal/metabolismo , Receptores Mensajeros de Linfocitos/metabolismo
4.
EJNMMI Res ; 12(1): 55, 2022 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-36065070

RESUMEN

BACKGROUND: Our aim was to investigate the discriminative value of 18F-Flutemetamol PET in longitudinal assessment of amyloid beta accumulation in amnestic mild cognitive impairment (aMCI) patients, in relation to longitudinal cognitive changes. METHODS: We investigated the change in 18F-Flutemetamol uptake and cognitive impairment in aMCI patients over time up to 3 years which enabled us to investigate possible association between changes in brain amyloid load and cognition over time. Thirty-four patients with aMCI (mean age 73.4 years, SD 6.6) were examined with 18F-Flutemetamol PET scan, brain MRI and cognitive tests at baseline and after 3-year follow-up or earlier if the patient had converted to Alzheimer´s disease (AD). 18F-Flutemetamol data were analyzed both with automated region-of-interest analysis and voxel-based statistical parametric mapping. RESULTS: 18F-flutemetamol uptake increased during the follow-up, and the increase was significantly higher in patients who were amyloid positive at baseline as compared to the amyloid-negative ones. At follow-up, there was a significant association between 18F-Flutemetamol uptake and MMSE, logical memory I (immediate recall), logical memory II (delayed recall) and verbal fluency. An association was seen between the increase in 18F-Flutemetamol uptake and decline in MMSE and logical memory I scores. CONCLUSIONS: In the early phase of aMCI, presence of amyloid pathology at baseline strongly predicted amyloid accumulation during follow-up, which was further paralleled by cognitive declines. Inversely, some of our patients remained amyloid negative also at the end of the study without significant change in 18F-Flutemetamol uptake or cognition. Future studies with longer follow-up are needed to distinguish whether the underlying pathophysiology of aMCI in such patients is other than AD.

5.
Contrast Media Mol Imaging ; 2022: 8676787, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36082064

RESUMEN

Purpose: In head and neck squamous cell carcinoma (HNSCC), the early diagnosis and efficient detection of recurrences and/or residual tumor after treatment play a very important role in patient's prognosis. Positron emission tomography (PET) using 2-deoxy-2-18F-fluoro-D-glucose (18F-FDG) has become an established method for the diagnosis of suspected recurrence in head and neck carcinomas. In particular, integrated PET/MRI imaging that provides optimal soft tissue contrast and less dental implant artifacts compared to PET/CT is an intriguing technique for the follow-up imaging of HNSCC patients. The aim of this study was to evaluate the benefit of PET/MRI compared to PET/CT in post-treatment follow-up imaging of HNSCC patients. Methods: This retrospective observational cohort study consists of 104 patients from our center with histologically confirmed HNSCC. All patients received chemoradiotherapy (CRT) and underwent 18F-FDG-PET/CT (n = 52) or 18F-FDG-PET/MRI (n = 52) scan 12 weeks after the end of treatment. Image analysis was performed by two independent readers according to a five-point Likert scale analysis. Results: PET/MRI was more sensitive (1.00 vs. 0.77) than PET/CT in the detection of locoregional recurrence. PET/MRI also had better negative (1.00 vs. 0.87) predictive values. AUCs for PET/MRI and PET/CT on patient-based analysis were 0.997 (95% CI 0.989-1.000) and 0.890 (95% CI 0.806-0.974), respectively. The comparison of sensitivity, AUCs, and negative predictive values revealed a statistically significant difference, p < 0.05. In PET/CT, false-negative and positive findings were observed in the more advanced disease stages, where PET/MRI performed better. Also, false-negative findings were located in the oropharyngeal, laryngeal, and nasopharyngeal regions, where PET/MRI made no false-negative interpretations. Conclusion: Based on these results, PET/MRI might be considered the modality of choice in detecting locoregional recurrence in HNSCC patients, especially in the more advanced stages in the oral cavity, larynx, or nasopharynx.


Asunto(s)
Carcinoma de Células Escamosas , Neoplasias de Cabeza y Cuello , Carcinoma de Células Escamosas/diagnóstico por imagen , Carcinoma de Células Escamosas/terapia , Quimioradioterapia , Fluorodesoxiglucosa F18 , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/terapia , Humanos , Imagen por Resonancia Magnética/métodos , Recurrencia Local de Neoplasia/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Tomografía de Emisión de Positrones , Radiofármacos , Estudios Retrospectivos , Carcinoma de Células Escamosas de Cabeza y Cuello/diagnóstico por imagen , Carcinoma de Células Escamosas de Cabeza y Cuello/terapia
6.
Bioconjug Chem ; 33(7): 1393-1404, 2022 07 20.
Artículo en Inglés | MEDLINE | ID: mdl-35709482

RESUMEN

Radiolabeled peptides have emerged as highly specific agents for targeting receptors expressed in tumors for therapeutic and diagnostic purposes. Peptides developed for positron emission tomography (PET) are typically radiolabeled using prosthetic groups or bifunctional chelators for fast "kit-like" incorporation of the radionuclide into the structure. A novel [18F]alkylammoniomethyltrifluoroborate ([18F]AmBF3) tetrazine (Tz), [18F]AmBF3-Tz, was developed for the [18F]fluorination of trans-cyclooctene (TCO)-modified biomolecules using Tyr3-octreotides (TOCs) as model peptides. [18F]AmBF3-Tz (Am = 15.4 ± 9.2 GBq/µmol, n = 14) was evaluated in healthy mice by ex vivo biodistribution and PET/computed tomography (CT), where the radiolabel in the prosthetic group was found stable in vivo, indicated by the low bone uptake in tibia (0.4 ± 0.1% ID/g, t = 270 min). TCO-TOCs tailored with polyethylene glycol (PEG) linkers were radiolabeled with [18F]AmBF3-Tz, forming two new tracers, [18F]AmBF3-PEG4-TOC (Am = 2.8 ± 1.8 GBq/µmol, n = 3) and [18F]AmBF3-PEG7-TOC (Am of 6.0 ± 3.4 GBq/µmol, n = 13), which were evaluated by cell uptake studies and ex vivo biodistribution in subcutaneous AR42J rat pancreatic carcinoma tumor-bearing nude mice. The tracer demonstrating superior behavior ex vivo, the [18F]AmBF3-PEG7-TOC, was further evaluated with PET/CT, where the tracer provided clear tumor visualization (SUVbaseline = 1.01 ± 0.07, vs SUVblocked = 0.76 ± 0.04) at 25 min post injection. The novel AmBF3-Tz demonstrated that it offers potential as a prosthetic group for rapid radiolabeling of biomolecules in mild conditions using bioorthogonal chemistry.


Asunto(s)
Compuestos Heterocíclicos , Octreótido , Animales , Línea Celular Tumoral , Radioisótopos de Flúor/química , Ratones , Ratones Desnudos , Neoplasias Pancreáticas , Polietilenglicoles , Tomografía Computarizada por Tomografía de Emisión de Positrones , Tomografía de Emisión de Positrones/métodos , Radiofármacos/química , Ratas , Distribución Tisular , Neoplasias Pancreáticas
7.
J Nucl Med ; 63(10): 1598-1603, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35273093

RESUMEN

68Ga-citrate has one of the simplest chemical structures of all 68Ga-radiopharmaceuticals, and its clinical use is justified by the proven medical applications using its isotope-labeled compound 67Ga-citrate. To support broader application of 68Ga-citrate in medical diagnosis, further research is needed to gain clinical data from healthy volunteers. In this work, we studied the biodistribution of 68Ga-citrate and subsequent radiation exposure from it in healthy men. Methods: 68Ga-citrate was prepared with an acetone-based radiolabeling procedure compliant with good manufacturing practices. Six healthy men (age 41 ± 12 y, mean ± SD) underwent sequential whole-body PET/CT scans after an injection of 204 ± 8 MBq of 68Ga-citrate. Serial arterialized venous blood samples were collected during PET imaging, and the radioactivity concentration was measured with a γ-counter. Urinary voids were collected and measured. The MIRD bladder-voiding model with a 3.5-h voiding interval was used. A model using a 70-kg adult man and the MIRD schema was used to estimate absorbed doses in target organs and effective doses. Calculations were performed using OLINDA/EXM software, version 2.0. Results: Radioactivity clearance from the blood was slow, and relatively high radioactivity concentrations were observed over the whole of the 3-h measuring period. Although radioactivity excretion via urine was rather slow (biologic half-time, 69 ± 24 h), the highest decay-corrected concentrations in urinary bladder contents were measured at the 90- and 180-min time points. Moderate concentrations were also seen in kidneys, liver, and spleen. The source organs showing the largest residence times were muscle, liver, lung, and heart contents. The heart wall received the highest absorbed dose, 0.077 ± 0.008 mSv/MBq. The mean effective dose (International Commission on Radiological Protection publication 103) was 0.021 ± 0.001 mSv/MBq. Conclusion: PET imaging with 68Ga-citrate is associated with modest radiation exposure. A 200-MBq injection of 68Ga-citrate results in an effective radiation dose of 4.2 mSv, which is in the same range as other 68Ga-labeled tracers. This suggests the feasibility of clinical studies using 68Ga-citrate imaging in humans and the possibility of performing multiple scans in the same subjects across the course of a year.


Asunto(s)
Productos Biológicos , Radioisótopos de Galio , Acetona , Adulto , Citratos , Ácido Cítrico , Galio , Humanos , Cinética , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Tomografía de Emisión de Positrones , Tomografía de Emisión de Positrones/métodos , Dosis de Radiación , Radiometría/métodos , Radiofármacos , Distribución Tisular
8.
J Nucl Cardiol ; 29(4): 1964-1972, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-33948894

RESUMEN

In Myocardial Perfusion Imaging (MPI) with Positron Emission Tomography/Computed Tomography (PET/CT) systems, accurate quantification is essential. We assessed flow quantification accuracy over various injected activities using a flow phantom. METHODS: The study was performed on the digital 4-ring Discovery MI (DMI-20) and analog Discovery 690 (D690) PET/CT systems, using 325-1257 MBq of [15O]H2O. PET performance and flow quantification accuracy were assessed in terms of count-rates, dead-time factors (DTF), scatter fractions (SF), time-activity curves (TACs), areas-under-the-curves (AUCs) and flow values. RESULTS: On DMI-20, prompts of 12.8 Mcps, DTF of 2.06 and SF of 46.1% were measured with 1257 MBq of activity. On the D690, prompts of 6.85 Mcps, DTF of 1.57 and SF of 32.5% were measured with 1230 MBq of activity. AUC values were linear over all activities. Mean wash-in flow error was - 9% for both systems whereas wash-out flow error was - 5% and - 6% for DMI-20 and D690. With the highest activity, wash-out flow error was - 12% and - 7% for the DMI-20 and D690. CONCLUSION: DMI-20 and D690 preserved accurate flow quantification over all injected activities, with maximum error of - 12%. In the future, flow quantification accuracy over the activities and count-rates evaluated in this study should be assessed.


Asunto(s)
Imagen de Perfusión Miocárdica , Humanos , Imagen de Perfusión Miocárdica/métodos , Fantasmas de Imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones , Tomografía de Emisión de Positrones/métodos
9.
J Nucl Cardiol ; 28(4): 1271-1280, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-31317328

RESUMEN

BACKGROUND: Assessment of myocardial viability is often needed in patients with chest pain and reduced ejection fraction. We evaluated the performance of reduced resting MBF, perfusable tissue fraction (PTF), and perfusable tissue index (PTI) in the assessment of myocardial viability in a pig model of myocardial infarction (MI). METHODS AND RESULTS: Pigs underwent resting [15O]water PET perfusion study 12 weeks after surgical (n = 16) or 2 weeks after catheter-based (n = 4) occlusion of the proximal left anterior descending coronary artery. MBF, PTF, and PTI were compared with volume fraction of MI in matched segments as assessed by triphenyl tetrazolium chloride staining of LV slices. MBF and PTF were lower in infarcted than non-infarcted segments. Segmental analysis of MBF showed similar area under the curve (AUC) of 0.85, 0.86, and 0.90 with relative MBF, PTF, and PTI for the detection of viable myocardium defined as infarct volume fraction of < 75%. Cut-off values of relative MBF of ≥ 67% and PTF of ≥ 66% resulted in accuracies of 90% and 81%, respectively. CONCLUSIONS: Our results indicate that resting MBF, PTF, and PTI based on [15O]water PET perfusion imaging are useful for the assessment of myocardial viability.


Asunto(s)
Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/patología , Tomografía de Emisión de Positrones , Animales , Circulación Coronaria , Modelos Animales de Enfermedad , Infarto del Miocardio/fisiopatología , Radioisótopos de Oxígeno , Valor Predictivo de las Pruebas , Curva ROC , Porcinos , Supervivencia Tisular
10.
J Nucl Med ; 62(5): 679-684, 2021 05 10.
Artículo en Inglés | MEDLINE | ID: mdl-33067338

RESUMEN

This first-in-humans study investigated the safety, biodistribution, and radiation dosimetry of a novel 18F-labeled radiohybrid prostate-specific membrane antigen (rhPSMA) PET imaging agent, 18F-rhPSMA-7.3. Methods: Six healthy volunteers (3 men, 3 women) underwent multiple whole-body PET acquisitions at scheduled time points up to 248 min after the administration of 18F-rhPSMA-7.3 (mean activity, 220; range, 210-228 MBq). PET scans were conducted in 3 separate sessions, and subjects were encouraged to void between sessions. Blood and urine samples were collected for up to 4 h after injection to assess metabolite-corrected radioactivity in whole blood, plasma, and urine. Quantitative measurements of 18F radioactivity in volumes of interest over target organs were determined directly from the PET images at 8 time points, and normalized time-activity concentration curves were generated. These normalized cumulated activities were then inputted into the OLINDA/EXM package to calculate the internal radiation dosimetry and the subjects' effective dose. Results:18F-rhPSMA-7.3 was well tolerated. One adverse event (mild headache, not requiring medication) was considered possibly related to 18F-rhPSMA-7.3. The calculated effective dose was 0.0141 mSv/MBq when using a 3.5-h voiding interval. The organs with the highest mean absorbed dose per unit of administered radioactivity were the adrenals (0.1835 mSv/MBq), the kidneys (0.1722 mSv/MBq), the submandibular glands (0.1479 mSv), and the parotid glands (0.1137 mSv/MBq). At the end of the first scanning session (mean time, 111 min after injection), an average of 7.2% (range, 4.4%-9.0%) of the injected radioactivity of 18F-rhPSMA-7.3 was excreted into urine. Conclusion: The safety, biodistribution, and internal radiation dosimetry of 18F-rhPSMA-7.3 are considered favorable for PET imaging.


Asunto(s)
Antígenos de Superficie/química , Radioisótopos de Flúor/química , Glutamato Carboxipeptidasa II/química , Glutamato Carboxipeptidasa II/farmacocinética , Voluntarios Sanos , Seguridad , Adulto , Antígenos de Superficie/efectos adversos , Femenino , Glutamato Carboxipeptidasa II/efectos adversos , Humanos , Marcaje Isotópico , Masculino , Radiometría , Distribución Tisular
11.
J Nucl Med ; 62(4): 577-583, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-32817143

RESUMEN

Sialic acid-binding immunoglubulinlike lectin 9 (Siglec-9) is a ligand of vascular adhesion protein 1. A 68Ga-labeled peptide of Siglec-9, 68Ga-DOTA-Siglec-9, holds promise as a novel PET tracer for imaging of inflammation. This first-in-humans study investigated the safety, tolerability, biodistribution, and radiation dosimetry of this radiopharmaceutical. Methods: Six healthy men underwent dynamic whole-body PET/CT. Serial venous blood samples were drawn from 1 to 240 min after intravenous injection of 162 ± 4 MBq of 68Ga-DOTA-Siglec-9. In addition to γ-counting, the plasma samples were analyzed by high-performance liquid chromatography to detect intact tracer and radioactive metabolites. Radiation doses were calculated using the OLINDA/EXM software, version 2.2. In addition, a patient with early rheumatoid arthritis was studied with both 68Ga-DOTA-Siglec-9 and 18F-FDG PET/CT to determine the ability of the new tracer to detect arthritis. Results:68Ga-DOTA-Siglec-9 was well tolerated by all subjects. 68Ga-DOTA-Siglec-9 was rapidly cleared from the blood circulation, and several radioactive metabolites were detected. The organs with the highest absorbed doses were the urinary bladder wall (0.38 mSv/MBq) and kidneys (0.054 mSv/MBq). The mean effective dose was 0.022 mSv/MBq (range, 0.020-0.024 mSv/MBq). Most importantly, however, 68Ga-DOTA-Siglec-9 was comparable to 18F-FDG in detecting arthritis. Conclusion: Intravenous injection of 68Ga-DOTA-Siglec-9 was safe and biodistribution was favorable for testing of the tracer in larger group of patients with rheumatoid arthritis, as is planned for the next phase of clinical trials. The effective radiation dose of 68Ga-DOTA-Siglec-9 was within the same range as the effective radiation doses of other 68Ga-labeled tracers. Injection of 150 MBq of 68Ga-DOTA-Siglec-9 would expose a subject to 3.3 mSv. These findings support the possible repeated clinical use of 68Ga-DOTA-Siglec-9, such as in trials to elucidate the treatment efficacy of novel drug candidates.


Asunto(s)
Amina Oxidasa (conteniendo Cobre)/metabolismo , Antígenos CD/química , Moléculas de Adhesión Celular/metabolismo , Radioisótopos de Galio/química , Compuestos Heterocíclicos con 1 Anillo/química , Tomografía Computarizada por Tomografía de Emisión de Positrones , Radiofármacos/química , Radiofármacos/metabolismo , Lectinas Similares a la Inmunoglobulina de Unión a Ácido Siálico/química , Adulto , Femenino , Humanos , Ligandos , Masculino , Radiofármacos/efectos adversos , Radiofármacos/farmacocinética , Seguridad , Solubilidad , Distribución Tisular
12.
Sci Rep ; 10(1): 13593, 2020 08 12.
Artículo en Inglés | MEDLINE | ID: mdl-32788595

RESUMEN

Folate receptor ß (FR-ß), a marker expressed on macrophages, is a promising target for imaging of inflammation. Here, we report the radiosynthesis and preclinical evaluation of [68Ga]Ga-NOTA-folate (68Ga-FOL). After determining the affinity of 68Ga-FOL using cells expressing FR-ß, we studied atherosclerotic mice with 68Ga-FOL and 18F-FDG PET/CT. In addition, we studied tracer distribution and co-localization with macrophages in aorta cryosections using autoradiography, histology, and immunostaining. The specificity of 68Ga-FOL was assessed in a blocking study with folate glucosamine. As a final step, human radiation doses were extrapolated from rat PET data. We were able to produce 68Ga-FOL with high radiochemical purity and moderate molar activity. Cell binding studies revealed that 68Ga-FOL had 5.1 nM affinity for FR-ß. Myocardial uptake of 68Ga-FOL was 20-fold lower than that of 18F-FDG. Autoradiography and immunohistochemistry of the aorta revealed that 68Ga-FOL radioactivity co-localized with Mac-3-positive macrophage-rich atherosclerotic plaques. The plaque-to-healthy vessel wall ratio of 68Ga-FOL was significantly higher than that of 18F-FDG. Blocking studies verified that 68Ga-FOL was specific for FR. Based on estimations from rat data, the human effective dose was 0.0105 mSv/MBq. Together, these findings show that 68Ga-FOL represents a promising new FR-ß-targeted tracer for imaging macrophage-associated inflammation.


Asunto(s)
Receptor 2 de Folato/metabolismo , Ácido Fólico/química , Compuestos Heterocíclicos con 1 Anillo/química , Macrófagos/metabolismo , Tomografía de Emisión de Positrones/métodos , Radiofármacos/química , Animales , Células CHO , Cricetinae , Cricetulus , Fluorodesoxiglucosa F18/química , Fluorodesoxiglucosa F18/farmacocinética , Radioisótopos de Galio/química , Radioisótopos de Galio/farmacocinética , Humanos , Ratones , Placa Aterosclerótica/metabolismo , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Radiofármacos/farmacocinética , Ratas , Distribución Tisular
13.
EJNMMI Res ; 10(1): 9, 2020 Feb 10.
Artículo en Inglés | MEDLINE | ID: mdl-32040792

RESUMEN

BACKGROUND: Chronic kidney disease (CKD) is associated with endothelial dysfunction and increased cardiovascular mortality. Endothelial dysfunction can be studied measuring myocardial perfusion reserve (MPR). MPR is the ratio of stress and rest myocardial perfusion (MP) and reflects the capacity of vascular bed to increase perfusion and microvascular responsiveness. In this pilot study, our aim was to assess MPR of 19 patients with kidney transplant (CKD stages 2-3) and of ten healthy controls with quantitative [15O]H2O positron emission tomography (PET) method. RESULTS: Basal MP was statistically significantly higher at rest in the kidney transplant patients than in the healthy controls [1.3 (0.4) ml/min/g and 1.0 (0.2) ml/min/g, respectively, p = 0.0015]. After correction of basal MP by cardiac workload [MPcorr = basal MP/individual rate pressure product (RPP) × average RPP of the healthy controls], the difference between the groups disappeared [0.9 (0.2) ml/min/g and 1.0 (0.3) ml/min/g, respectively, p = 0.55)]. There was no difference in stress MP between the kidney transplant patients and the healthy subjects [3.8 (1.0) ml/min/g and 4.0 (0.9) ml/min/g, respectively, p = 0.53]. Although MPR was reduced, MPRcorr (stress MP/basal MPcorr) did not differ between the kidney transplant patients and the healthy controls [4.1 (1.1) and 4.3 (1.6), respectively, p = 0.8]. CONCLUSIONS: MP during stress is preserved in kidney transplant patients with CKD stage 2-3. The reduced MPR appears to be explained by increased resting MP. This is likely linked with increased cardiac workload due to sympathetic overactivation in kidney transplant patients.

14.
BMC Nephrol ; 20(1): 437, 2019 11 27.
Artículo en Inglés | MEDLINE | ID: mdl-31775670

RESUMEN

BACKGROUND: Despite improvement in short-term outcome of kidney transplants, the long-term survival of kidney transplants has not changed over past decades. Kidney biopsy is the gold standard of transplant pathology but it's invasive. Quantification of transplant blood flow could provide a novel non-invasive method to evaluate transplant pathology. The aim of this retrospective cross-sectional pilot study was to evaluate positron emission tomography (PET) as a method to measure kidney transplant perfusion and find out if there is correlation between transplant perfusion and histopathology. METHODS: Renal cortical perfusion of 19 kidney transplantation patients [average time from transplantation 33 (17-54) months; eGFR 55 (47-69) ml/min] and 10 healthy controls were studied by [15 O]H2O PET. Perfusion and Doppler resistance index (RI) of transplants were compared with histology of one-year protocol transplant biopsy. RESULTS: Renal cortical perfusion of healthy control subjects and transplant patients were 2.7 (2.4-4.0) ml min- 1 g- 1 and 2.2 (2.0-3.0) ml min- 1 g- 1, respectively (p = 0.1). Renal vascular resistance (RVR) of the patients was 47.0 (36.7-51.4) mmHg mL- 1min- 1g- 1 and that of the healthy 32.4 (24.6-39.6) mmHg mL- 1min-1g-1 (p = 0.01). There was a statistically significant correlation between Doppler RI and perfusion of transplants (r = - 0.51, p = 0.026). Transplant Doppler RI of the group of mild fibrotic changes [0.73 (0.70-0.76)] and the group of no fibrotic changes [0.66 (0.61-0.72)] differed statistically significantly (p = 0.03). No statistically significant correlation was found between cortical perfusion and fibrosis of transplants (p = 0.56). CONCLUSIONS: [15 O]H2O PET showed its capability as a method in measuring perfusion of kidney transplants. RVR of transplant patients with stage 2-3 chronic kidney disease was higher than that of the healthy, although kidney perfusion values didn't differ between the groups. Doppler based RI correlated with perfusion and fibrosis of transplants.


Asunto(s)
Fallo Renal Crónico/cirugía , Trasplante de Riñón/efectos adversos , Imagen de Perfusión/métodos , Tomografía de Emisión de Positrones/métodos , Circulación Renal , Trasplantes , Resistencia Vascular , Biopsia/métodos , Correlación de Datos , Estudios Transversales , Femenino , Humanos , Pruebas de Función Renal/métodos , Trasplante de Riñón/métodos , Efectos Adversos a Largo Plazo/diagnóstico , Efectos Adversos a Largo Plazo/fisiopatología , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Trasplantes/irrigación sanguínea , Trasplantes/diagnóstico por imagen , Trasplantes/patología
15.
Ultrasound Med Biol ; 45(2): 568-578, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30467033

RESUMEN

We evaluated the relationships between regional myocardial strain measured by speckle tracking echocardiography and viability, fibrosis, hypertrophy and oxygen consumption in the infarcted or remote myocardium in a pig model of chronic myocardial infarction (MI). Thirteen farm pigs with surgical occlusion of the left anterior descending coronary artery and five sham-operated pigs were studied 3 mo post-MI. Computed tomography revealed significant left ventricle remodeling. Reduced radial or circumferential strain identified areas of transmural infarction (area under the curve: 0.82 and 0.79, respectively). In the remote non-infarcted area, radial strain correlated inversely with the amount of fibrosis (r = -0.66, p = 0.04) and myocyte hypertrophy (r = -0.68, p = 0.03). Radial strain rate inversely correlated with myocardial resting oxygen consumption assessed with 11C-labeled acetate positron emission tomography (r = -0.71, p = 0.006). In conclusion, myocardial strain and strain rate reflect fibrosis, hypertrophy and oxygen consumption of the remote areas after MI.


Asunto(s)
Ecocardiografía/métodos , Corazón/diagnóstico por imagen , Corazón/fisiopatología , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/fisiopatología , Animales , Enfermedad Crónica , Modelos Animales de Enfermedad , Masculino , Porcinos
16.
J Comput Assist Tomogr ; 42(5): 754-759, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30015798

RESUMEN

OBJECTIVE: We aimed to validate the accuracy of imaging of left atrial and ventricular volumes using cardiac cadaveric silicone casts. METHODS: Left atrial (n = 14) and ventricular (n = 15) casts were imaged using 64-slice computed tomography (CT). Water displacement (WD) of cardiac casts was used as the gold standard for volume measurements. RESULTS: Compared with WD, CT resulted in slightly higher left atrial and ventricular volumes (54 ± 25 vs 56 ± 26 mL [P = 0.003] and 57 ± 47 vs 66 ± 47 mL [P = 0.0001]). Variability between left atrial and ventricular volumes by CT and WD was low (coefficients of variation [CVs], 4% [intraclass correlation coefficient {ICC}, 0.99] and 12% [ICC, 0.97]). Intraobserver variability of CT was low for both the left atrium and the left ventricle (CVs, 1% [ICC, 1.00] and 4% [ICC, 1.00]). CONCLUSIONS: Cardiac CT is both accurate and reproducible in assessment of left ventricular and atrial chamber volumes.


Asunto(s)
Ventrículos Cardíacos/anatomía & histología , Ventrículos Cardíacos/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Cadáver , Atrios Cardíacos/anatomía & histología , Atrios Cardíacos/diagnóstico por imagen , Humanos , Técnicas In Vitro , Modelos Biológicos , Variaciones Dependientes del Observador , Tamaño de los Órganos , Reproducibilidad de los Resultados
17.
J Transl Med ; 15(1): 144, 2017 06 19.
Artículo en Inglés | MEDLINE | ID: mdl-28629432

RESUMEN

BACKGROUND: Radiolabeled RGD peptides detect αvß3 integrin expression associated with angiogenesis and extracellular matrix remodeling after myocardial infarction. We studied whether cardiac positron emission tomography (PET) with [68Ga]NODAGA-RGD detects increased αvß3 integrin expression after induction of flow-limiting coronary stenosis in pigs, and whether αvß3 integrin is expressed in viable ischemic or injured myocardium. METHODS: We studied 8 Finnish landrace pigs 13 ± 4 days after percutaneous implantation of a bottleneck stent in the proximal left anterior descending coronary artery. Antithrombotic therapy was used to prevent stent occlusion. Myocardial uptake of [68Ga]NODAGA-RGD (290 ± 31 MBq) was evaluated by a 62 min dynamic PET scan. The ischemic area was defined as the regional perfusion abnormality during adenosine-induced stress by [15O]water PET. Guided by triphenyltetrazolium chloride staining, tissue samples from viable and injured myocardial areas were obtained for autoradiography and histology. RESULTS: Stent implantation resulted in a partly reversible myocardial perfusion abnormality. Compared with remote myocardium, [68Ga]NODAGA-RGD PET showed increased tracer uptake in the ischemic area (ischemic-to-remote ratio 1.3 ± 0.20, p = 0.0034). Tissue samples from the injured areas, but not from the viable ischemic areas, showed higher [68Ga]NODAGA-RGD uptake than the remote non-ischemic myocardium. Uptake of [68Ga]NODAGA-RGD correlated with immunohistochemical detection of αvß3 integrin that was expressed in the injured myocardial areas. CONCLUSIONS: Cardiac [68Ga]NODAGA-RGD PET demonstrates increased myocardial αvß3 integrin expression after induction of flow-limiting coronary stenosis in pigs. Localization of [68Ga]NODAGA-RGD uptake indicates that it reflects αvß3 integrin expression associated with repair of recent myocardial injury.


Asunto(s)
Acetatos/química , Radioisótopos de Galio/química , Compuestos Heterocíclicos con 1 Anillo/química , Integrina alfaVbeta3/metabolismo , Isquemia Miocárdica/diagnóstico por imagen , Oligopéptidos/química , Tomografía de Emisión de Positrones , Acetatos/farmacocinética , Animales , Autorradiografía , Circulación Coronaria , Radioisótopos de Galio/farmacocinética , Compuestos Heterocíclicos con 1 Anillo/farmacocinética , Cinética , Isquemia Miocárdica/patología , Isquemia Miocárdica/fisiopatología , Miocardio/patología , Oligopéptidos/farmacocinética , Sus scrofa , Distribución Tisular
18.
J Nucl Med ; 58(10): 1691-1698, 2017 10.
Artículo en Inglés | MEDLINE | ID: mdl-28336781

RESUMEN

In PET, corrections for photon scatter and attenuation are essential for visual and quantitative consistency. MR attenuation correction (MRAC) is generally conducted by image segmentation and assignment of discrete attenuation coefficients, which offer limited accuracy compared with CT attenuation correction. Potential inaccuracies in MRAC may affect scatter correction, because the attenuation image (µ-map) is used in single scatter simulation (SSS) to calculate the scatter estimate. We assessed the impact of MRAC to scatter correction using 2 scatter-correction techniques and 3 µ-maps for MRAC. Methods: The tail-fitted SSS (TF-SSS) and a Monte Carlo-based single scatter simulation (MC-SSS) algorithm implementations on the Philips Ingenuity TF PET/MR were used with 1 CT-based and 2 MR-based µ-maps. Data from 7 subjects were used in the clinical evaluation, and a phantom study using an anatomic brain phantom was conducted. Scatter-correction sinograms were evaluated for each scatter correction method and µ-map. Absolute image quantification was investigated with the phantom data. Quantitative assessment of PET images was performed by volume-of-interest and ratio image analysis. Results: MRAC did not result in large differences in scatter algorithm performance, especially with TF-SSS. Scatter sinograms and scatter fractions did not reveal large differences regardless of the µ-map used. TF-SSS showed slightly higher absolute quantification. The differences in volume-of-interest analysis between TF-SSS and MC-SSS were 3% at maximum in the phantom and 4% in the patient study. Both algorithms showed excellent correlation with each other with no visual differences between PET images. MC-SSS showed a slight dependency on the µ-map used, with a difference of 2% on average and 4% at maximum when a µ-map without bone was used. Conclusion: The effect of different MR-based µ-maps on the performance of scatter correction was minimal in non-time-of-flight 18F-FDG PET/MR brain imaging. The SSS algorithm was not affected significantly by MRAC. The performance of the MC-SSS algorithm is comparable but not superior to TF-SSS, warranting further investigations of algorithm optimization and performance with different radiotracers and time-of-flight imaging.


Asunto(s)
Encéfalo/diagnóstico por imagen , Fluorodesoxiglucosa F18 , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética , Tomografía de Emisión de Positrones , Dispersión de Radiación , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad
19.
Cardiovasc Ultrasound ; 15(1): 1, 2017 Jan 09.
Artículo en Inglés | MEDLINE | ID: mdl-28069008

RESUMEN

BACKGROUND: We evaluated echocardiographic area-length methods to measure left ventricle (LV) volumes and ejection fraction (EF) in parasternal short axis views in comparison with cardiac computed tomography (CT) in pigs with chronic myocardial infarction (MI). METHODS: Male farm pigs with surgical occlusion of the left anterior descending coronary artery (n = 9) or sham operation (n = 5) had transthoracic echocardiography and cardiac-CT 3 months after surgery. We measured length of the LV in parasternal long axis view, and both systolic and diastolic LV areas in parasternal short axis views at the level of mitral valve, papillary muscles and apex. Volumes and EF of the LV were calculated using Simpson's method of discs (tri-plane area) or Cylinder-hemiellipsoid method (single plane area). RESULTS: The pigs with coronary occlusion had anterior MI scars and reduced EF (average EF 42 ± 10%) by CT. Measurements of LV volumes and EF were reproducible by echocardiography. Compared with CT, end-diastolic volume (EDV) measured by echocardiography showed good correlation and agreement using either Simpson's method (r = 0.90; mean difference -2, 95% CI -47 to 43 mL) or Cylinder-hemiellipsoid method (r = 0.94; mean difference 3, 95% CI -44 to 49 mL). Furthermore, End-systolic volume (ESV) measured by echocardiography showed also good correlation and agreement using either Simpson's method (r = 0.94; mean difference 12 ml, 95% CI: -16 to 40) or Cylinder-hemiellipsoid method (r = 0.97; mean difference:13 ml, 95% CI: -8 to 33). EF was underestimated using either Simpson's method (r = 0.78; mean difference -6, 95% CI -11 to 1%) or Cylinder-hemiellipsoid method (r = 0.74; mean difference -4, 95% CI-10 to 2%). CONCLUSION: Our results indicate that measurement of LV volumes may be accurate, but EF is underestimated using either three or single parasternal short axis planes by echocardiography in a large animal model of chronic MI.


Asunto(s)
Ecocardiografía/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Infarto del Miocardio/diagnóstico , Tomografía Computarizada por Rayos X/métodos , Animales , Enfermedad Crónica , Modelos Animales de Enfermedad , Masculino , Reproducibilidad de los Resultados , Porcinos
20.
Contrast Media Mol Imaging ; 2017: 7645070, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29463960

RESUMEN

Sialic acid-binding immunoglobulin-like lectin 9 (Siglec-9) is a ligand of inflammation-inducible vascular adhesion protein-1 (VAP-1). We compared 68Ga-DOTA- and 18F-fluorodeoxyribose- (FDR-) labeled Siglec-9 motif peptides for PET imaging of inflammation. Methods. Firstly, we examined 68Ga-DOTA-Siglec-9 and 18F-FDR-Siglec-9 in rats with skin/muscle inflammation. We then studied 18F-FDR-Siglec-9 for the detection of inflamed atherosclerotic plaques in mice and compared it with previous 68Ga-DOTA-Siglec-9 results. Lastly, we estimated human radiation dosimetry from the rat data. Results. In rats, 68Ga-DOTA-Siglec-9 (SUV, 0.88 ± 0.087) and 18F-FDR-Siglec-9 (SUV, 0.77 ± 0.22) showed comparable (P = 0.29) imaging of inflammation. In atherosclerotic mice, 18F-FDR-Siglec-9 detected inflamed plaques with a target-to-background ratio (1.6 ± 0.078) similar to previously tested 68Ga-DOTA-Siglec-9 (P = 0.35). Human effective dose estimates for 68Ga-DOTA-Siglec-9 and 18F-FDR-Siglec-9 were 0.024 and 0.022 mSv/MBq, respectively. Conclusion. Both tracers are suitable for PET imaging of inflammation. The easier production and lower cost of 68Ga-DOTA-Siglec-9 present advantages over 18F-FDR-Siglec-9, indicating it as a primary choice for clinical studies.


Asunto(s)
Dermatitis/diagnóstico por imagen , Fluorodesoxiglucosa F18/farmacología , Radioisótopos de Galio/farmacología , Miositis/diagnóstico por imagen , Compuestos Organometálicos/farmacología , Tomografía de Emisión de Positrones/métodos , Lectinas Similares a la Inmunoglobulina de Unión a Ácido Siálico/farmacología , Animales , Inflamación/diagnóstico por imagen , Miositis/diagnóstico , Radiometría , Ratas , Ratas Sprague-Dawley
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...