Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Pacing Clin Electrophysiol ; 47(3): 347-352, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38140909

RESUMEN

BACKGROUND: Cryoballoon ablation for atrial fibrillation (AF) requires adequate contact between the pulmonary vein (PV) antrum and cryoballoon. The surge of intraballoon pressure during the initial phase of ablation may change the balloon's shape and compliance, resulting in balloon dislodgement and loss of PV occlusion. Without continuous monitoring, this phenomenon is often undetected but can be associated with incomplete PV isolation (PVI). METHODS: Primary cryoablation of AF was performed in 15 patients. PV occlusion status pre- and post-freezing were analyzed with intracardiac echocardiography (ICE) and dielectric imaging-based occlusion tool (DIOT) to calculate the incidence of expansion dislodgement of cryoballoon. RESULTS: A total of 105 cryoablation applications were performed on 57 veins, including three common ostiums of left pulmonary veins. In the evaluation of PV occlusion, both modalities reported consistent results in 86.7% of the assessments. Despite complete PV occlusion before ablation, peri-balloon leak after initiation of freezing was detected by ICE in 5/22 (22.7%) applications and by DIOT in 8/25 (32%) applications. CONCLUSION: Incidence of expansion dislodgement of the cryoballoon was detected in one-fourth to one-third of cryoablation applications depending on the imaging modality used, which was clinically frequent and significant.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Venas Pulmonares/cirugía , Incidencia , Fibrilación Atrial/cirugía , Criocirugía/métodos , Resultado del Tratamiento , Ablación por Catéter/métodos
2.
J Interv Card Electrophysiol ; 66(7): 1601-1607, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36604354

RESUMEN

BACKGROUND: With advancements in technology and ablation techniques, catheter ablation for the treatment of atrial fibrillation (AF) has become safer with time. In the past, standard-of-care recommended overnight stay for outpatient procedures. As safety has improved and procedure times have shortened, some centers have allowed for same-day discharge. We report the results of a multi-center, randomized clinical trial investigating the safety of same-day discharge post-cryoballoon ablation. METHODS: Patients with paroxysmal atrial fibrillation underwent pulmonary vein isolation (PVI) with the Medtronic Arctic Advance cryoballoon at 3 US centers. Six hours after the procedure, patients were randomized to either stay overnight or be discharged same day. RESULTS: A total of 49 patients were enrolled. Two patients were withdrawn prior to randomization. One patient chose to withdraw after randomization. Of the 22 patients randomized to same-day discharge and the 23 patients randomized the overnight stay, no significant adverse outcomes were reported in either group. Occurrence of adverse events did not differ significantly between the two groups. Procedure time and fluoroscopy time did not significantly differ between groups. CONCLUSIONS: This is the first randomized trial examining the safety of same-day discharge post-cryoballoon ablation. Based on our results, same-day discharge following cryoballoon ablation for paroxysmal AF is a safe option following uncomplicated ablation for PVI. Operators should use their discretion in selecting patients for same-day discharge.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Alta del Paciente , Resultado del Tratamiento , Venas Pulmonares/cirugía , Criocirugía/métodos , Ablación por Catéter/métodos , Recurrencia
3.
Curr Opin Cardiol ; 38(1): 6-10, 2023 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-36598444

RESUMEN

PURPOSE OF REVIEW: Despite technological advancements in catheter ablation, patients with atrial fibrillation often require multiple ablations, with diminishing returns depending on duration and persistence. Although early ablation is vital, modification of atrial fibrillation disease can be achieved with modification of existing risk factors. Obesity is an important modifiable risk factor, but there does not appear to be a consensus on the best method or goal for weight reduction. RECENT FINDINGS: The relationship between atrial fibrillation and obesity has been acknowledged. This review examines the clinical evidence demonstrating the benefit of weight reduction in the management of atrial fibrillation. In particular, this review compares the different approaches of recent studies. SUMMARY: On the basis of the literature, the authors recommend a structured weight loss programme with dietary and behavioural modifications individualized to each patient and including the implementation of physical activity. Consideration of bariatric surgery is appropriate in certain patients with obesity.


Asunto(s)
Fibrilación Atrial , Pérdida de Peso , Humanos , Fibrilación Atrial/etiología , Fibrilación Atrial/terapia , Cirugía Bariátrica/efectos adversos , Ablación por Catéter/métodos , Obesidad/etiología , Factores de Riesgo , Resultado del Tratamiento
4.
Curr Opin Cardiol ; 37(1): 62-67, 2022 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-34783712

RESUMEN

PURPOSE OF REVIEW: The cryoballoon catheter has been an option for the treatment of atrial fibrillation for over a decade. The most widely used device is the Medtronic Arctic Advance cryoballoon catheter. Recently, Boston Scientific has released the POLARx cryoballoon catheter. Here we review the major changes in the catheter system's design and its implications for procedural practice. RECENT FINDINGS: The POLARx cryoballoon catheter has been approved for use in Europe. Some studies have been published detailing the first clinical experiences in vivo with this newest technology. SUMMARY: The changes to the POLARx cryoballoon catheter, particularly its ability to maintain balloon size and pressure, will improve occlusion and theoretically improve procedural outcomes.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Fibrilación Atrial/cirugía , Humanos , Venas Pulmonares/cirugía , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA