Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Can J Cardiol ; 2024 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-39067618

RESUMEN

BACKGROUND: The optimal medical treatment strategy after transcatheter aortic valve replacement (TAVR) has not been established, and might be affected by the extent of extravalvular cardiac damage. We aimed to investigate the prognostic association of renin-angiotensin system (RAS) inhibitors in TAVR patients stratified according to the extent of extravalvular cardiac damage. METHODS: In a prospective TAVR registry, patients were retrospectively evaluated for baseline cardiac damage and classified into 5 stages of cardiac damage (0-4) according to established criteria. Clinical outcomes at 1 year were compared according to RAS inhibitor prescription at discharge. RESULTS: Among 2247 eligible patients who underwent TAVR between August 2007 and June 2021, 1634 (72.7%) were prescribed RAS inhibitors at discharge. Eighty-three patients (3.7%) were classified as stage 0, 276 (12.3%) as stage 1, 889 (39.6%) as stage 2, 489 (21.8%) as stage 3, and 510 (22.7%) as stage 4. RAS inhibitor prescription after TAVR was associated with a reduced risk of 1-year mortality (adjusted hazard ratio [HRadjusted], 0.59; 95% confidence interval [CI], 0.45-0.77). The protective association was accentuated among patients with cardiac stages 3 and 4 (HRadjusted, 0.54 [95% CI, 0.32-0.92]; and HRadjusted, 0.58 [95% CI, 0.36-0.92], respectively), but not statistically significant in for those with stage 2 (HRadjusted, 0.70; 95% CI, 0.43-1.14). CONCLUSIONS: In patients who underwent TAVR, we found a strong association of RAS inhibitor prescription and improved clinical outcome in the overall population, and there were no signs of heterogeneity across stages of cardiac damage. CLINICAL TRIAL REGISTRATION: NCT01368250.

2.
JACC Cardiovasc Interv ; 17(14): 1676-1679, 2024 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-39048254
3.
JACC Cardiovasc Interv ; 17(10): 1252-1264, 2024 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-38811107

RESUMEN

BACKGROUND: Cardiac damage caused by aortic stenosis (AS) can be categorized into stages, which are associated with a progressively increasing risk of death after transcatheter aortic valve replacement (TAVR). OBJECTIVES: The authors investigated sex-related differences in cardiac damage among patients with symptomatic AS and the prognostic value of cardiac damage classification in women and men undergoing TAVR. METHODS: In a prospective registry, pre-TAVR echocardiograms were used to categorize patients into 5 stages of cardiac damage caused by AS. Differences in the extent of cardiac damage were compared according to sex, and its implications on clinical outcomes after TAVR were explored. RESULTS: Among 2,026 patients undergoing TAVR between August 2007 and June 2022 (995 [49.1%] women and 1,031 [50.9%] men), we observed sex-specific differences in the pattern of cardiac damage (women vs men; stage 0: 2.6% vs 3.1%, stage 1: 13.4% vs 10.1%, stage 2: 37.1% vs 39.5%, stage 3: 27.5% vs 15.6%, and stage 4: 19.4% vs 31.7%). There was a stepwise increase in 5-year all-cause mortality according to stage in women (HRadjusted: 1.43; 95% CI: 1.28-1.60, for linear trend) and men (HRadjusted: 1.26; 95% CI: 1.14-1.38, for linear trend). Female sex was associated with a lower 5-year mortality in early stages (stage 0, 1, or 2) but not in advanced stages (stage 3 or 4). CONCLUSIONS: The pattern of cardiac damage secondary to AS differed by sex. In early stages of cardiac damage, women had a lower 5-year mortality than men, whereas in more advanced stages, mortality was comparable between sexes. (SwissTAVI Registry; NCT01368250).


Asunto(s)
Estenosis de la Válvula Aórtica , Disparidades en el Estado de Salud , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Masculino , Factores Sexuales , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Anciano , Factores de Riesgo , Anciano de 80 o más Años , Medición de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Estudios Prospectivos , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Índice de Severidad de la Enfermedad
5.
JACC Cardiovasc Interv ; 17(8): 992-1003, 2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38658128

RESUMEN

BACKGROUND: Extravalvular cardiac damage caused by aortic stenosis affects prognosis after transcatheter aortic valve replacement (TAVR). The long-term impact of changes in cardiac damage in response to relief from mechanical obstruction has not been fully investigated. OBJECTIVES: The authors aimed to investigate changes in cardiac damage early after TAVR and the prognostic impact of the cardiac damage classification after TAVR. METHODS: In this single-center observational study, patients undergoing transfemoral TAVR were retrospectively evaluated for cardiac damage before and after TAVR and classified into 5 stages of cardiac damage (0-4). RESULTS: Among 1,863 patients undergoing TAVR between January 2007 and June 2022, 56 patients (3.0%) were classified as stage 0, 225 (12.1%) as stage 1, 729 (39.1%) as stage 2, 388 (20.8%) as stage 3, and 465 (25.0%) as stage 4. Cardiac stage changed in 47.7% of patients (improved: 30.1% in stages 1-4 and deteriorated: 24.7% in stages 0-3) early after TAVR. Five-year all-cause mortality was associated with cardiac damage both at baseline (HRadjusted: 1.34; 95% CI: 1.24-1.44; P < 0.001 for linear trend) and after TAVR (HRadjusted: 1.40; 95% CI: 1.30-1.51; P < 0.001 for linear trend). Five-year all-cause mortality was stratified by changes in cardiac damage (improved, unchanged, or worsened) in patients with cardiac stage 2, 3, and 4 (log-rank P < 0.001 for stage 2, 0.005 for stage 3, and <0.001 for stage 4). CONCLUSIONS: The extent of extra-aortic valve cardiac damage before and after TAVR and changes in cardiac stage early after TAVR have important prognostic implications during long-term follow-up. (SwissTAVI Registry; NCT01368250).


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/mortalidad , Masculino , Femenino , Estudios Retrospectivos , Factores de Tiempo , Anciano de 80 o más Años , Anciano , Factores de Riesgo , Resultado del Tratamiento , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Medición de Riesgo
7.
JACC Cardiovasc Interv ; 17(5): 681-692, 2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38479968

RESUMEN

BACKGROUND: The performance of latest iteration transcatheter aortic valve replacement platforms in patients with small aortic anatomy remains underexplored. OBJECTIVES: The aim of this study was to evaluate effectiveness and performance between the self-expanding (SE) Evolut PRO and PRO+ and the balloon-expandable (BE) SAPIEN ULTRA in patients with small aortic annuli. METHODS: Data from the OPERA-TAVI (Comparative Analysis of Evolut PRO vs. SAPIEN 3 ULTRA Valves for Transfemoral Transcatheter Aortic Valve Implantation) registry were used, with 1:1 propensity score matching. Primary endpoints included 1-year effectiveness composite (all-cause mortality, disabling stroke, or heart failure hospitalization) and 30-day device-related (hemodynamic structural valve dysfunction and nonstructural valve dysfunction) outcomes. RESULTS: Among 3,516 patients, 251 matched pairs with aortic annular area <430 mm2 were assessed. The 1-year primary effectiveness outcome did not differ significantly between cohorts (SE 10.8% vs BE 11.2%; P = 0.91). The 30-day device-oriented composite outcome was more favorable in the Evolut PRO group (SE 4.8% vs BE 10.4%; P = 0.027). Notably, SE valve recipients showed higher rates of disabling stroke (SE 4.0% vs BE 0.0%; P < 0.01) and paravalvular leaks (mild or greater: SE 48.5% vs BE 18.6% [P < 0.001]; moderate: SE 4.5% vs BE 1.2% [P = 0.070]). The BE group had higher rates of prosthesis-patient mismatch (moderate or greater: SE 16.0% vs BE 47.1% [P < 0.001]; severe: SE 1.3% vs BE 5.7% [P = 0.197]) and more patients with residual mean gradients >20 mm Hg (SE 1.0% vs BE 13.5%; P < 0.001). CONCLUSIONS: In patients with small aortic annuli, transcatheter aortic valve replacement with latest iteration devices is safe. SE platforms are associated with more favorable device performance in terms of hemodynamic structural and nonstructural dysfunction. Randomized data are needed to validate these findings and guide informed device selection.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Diseño de Prótesis , Resultado del Tratamiento , Sistema de Registros , Accidente Cerebrovascular/etiología
8.
JACC Cardiovasc Interv ; 17(5): 666-677, 2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38479966

RESUMEN

BACKGROUND: Acute ischemic stroke remains a serious complication of transcatheter aortic valve replacement (TAVR). Cerebral embolic protection devices (CEPD) were developed to mitigate the risk of acute ischemic stroke complicating TAVR (AISCT). However, the existing body of evidence does not clearly support CEPD efficacy in AISCT prevention. OBJECTIVES: In a cohort of patients with AISCT, we aimed to compare the characteristics and outcomes of patients who have had unprotected TAVR (CEPD-) vs CEPD-protected TAVR (CEPD+). METHODS: Data were derived from an international multicenter registry focusing on AISCT. We included all patients who experienced ischemic stroke within 72 hours of TAVR. Stroke severity was assessed using the National Institutes of Health Stroke Scale (NIHSS). Primary outcomes were neurologic disability status according to the modified Rankin Score at 30 days, and 6-month all-cause death. Propensity score matched analysis was used to control for differences between groups. RESULTS: In 18,725 TAVR procedures, 416 AISCT (2.2%) within 72 hours were documented, of which 376 were in the CEPD- TAVR group and 40 in the CEPD+ TAVR group. Although the middle cerebral artery stroke rate was similar in both groups (29.7% CEPD- vs 33.3% CEPD+; P = 0.71), AISCT in the CEPD+ group was characterized by a lower rate of internal carotid artery occlusion (0% vs 4.7%) and higher rate of vertebrobasilar system strokes (15.4% vs 5.7%; P = 0.04). AISCT was severe (NIHSS ≥15) in 21.6% CEPD- and 23.3% CEPD+ AISCT (P = 0.20). Disabling stroke rates (modified Rankin Score >1 at 30 days) were 47.3% vs 42.5% (P = 0.62), and 6-month mortality was 31.3% vs 23.3% (P = 0.61), in the CEPD- and CEPD+ groups, respectively. In the propensity score matched cohort, disabling stroke rates were 56.5% vs 41.6% (P = 0.16), and 6-month mortality was 33% vs 19.5% (P = 0.35), in the CEPD- and CEPD+ groups, respectively. CONCLUSIONS: In a large cohort of patients with AISCT, the use of CEPD had little effect on stroke distribution, severity, and outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Dispositivos de Protección Embólica , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Accidente Cerebrovascular Isquémico/etiología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Resultado del Tratamiento , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Factores de Riesgo , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía
9.
Eur J Radiol ; 175: 111425, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38490128

RESUMEN

PURPOSE: Our study aimed to determine whether 4D cardiac computed tomography (4DCCT) based quantitative myocardial analysis may improve risk stratification and can predict reverse remodeling (RRM) and mortality after transcatheter aortic valve implantation (TAVI). METHODS: Consecutive patients undergoing clinically indicated 4DCCT prior to TAVI were prospectively enrolled. 4DCCT-derived left- (LV) and right ventricular (RV), and left atrial (LA) dimensions, mass, ejection fraction (EF) and myocardial strain were evaluated to predict RRM and survival. RRM was defined by either relative increase in LVEF by 5% or relative decline in LV end diastolic diameter (LVEDD) by 5% assessed by transthoracic echocardiography prior TAVI, at discharge, and at 12-month follow-up compared to baseline prior to TAVI. RESULTS: Among 608 patients included in this study (55 % males, age 81 ± 6.6 years), RRM was observed in 279 (54 %) of 519 patients at discharge and in 218 (48 %) of 453 patients at 12-month echocardiography. While no CCT based measurements predicted RRM at discharge, CCT based LV mass index and LVEF independently predicted RRM at 12-month (ORadj = 1.012; 95 %CI:1.001-1.024; p = 0.046 and ORadj = 0.969; 95 %CI:0.943-0.996; p = 0.024, respectively). The most pronounced changes in LVEF and LVEDD were observed in patients with impaired LV function at baseline. In multivariable analysis age (HRadj = 1.037; 95 %CI:1.005-1.070; p = 0.022) and CCT-based LVEF (HRadj = 0.972; 95 %CI:0.945-0.999; p = 0.048) and LAEF (HRadj = 0.982; 95 %CI:0.968-0.996; p = 0.011) independently predicted survival. CONCLUSION: Comprehensive myocardial functional information derived from routine 4DCCT in patients with severe aortic stenosis undergoing TAVI could predict reverse remodeling and clinical outcomes at 12-month following TAVI.


Asunto(s)
Tomografía Computarizada Cuatridimensional , Reemplazo de la Válvula Aórtica Transcatéter , Remodelación Ventricular , Humanos , Masculino , Femenino , Anciano de 80 o más Años , Tomografía Computarizada Cuatridimensional/métodos , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estudios Prospectivos , Anciano , Ecocardiografía/métodos
10.
Am J Cardiol ; 219: 60-70, 2024 05 15.
Artículo en Inglés | MEDLINE | ID: mdl-38401656

RESUMEN

Evidence regarding gender-related differences in response to transcatheter aortic valve implantation according to the valve type is lacking. This study aimed to evaluate the impact of gender on the treatment effect of Evolut PRO/PRO+ (PRO) or SAPIEN 3 Ultra (ULTRA) devices on clinical outcomes. The Comparative Analysis of Evolut PRO vs SAPIEN 3 Ultra Valves for Transfemoral Transcatheter Aortic Valve Implantation (OPERA-TAVI) is a multicenter, multinational registry including patients who underwent the latest-iteration PRO or ULTRA implantation. Overall, 1,174 of 1,897 patients were matched based on valve type and compared according to gender, whereas 470 men and 630 women were matched and compared according to valve type. The 30-day and 1-year outcomes were evaluated. In the PRO and ULTRA groups, men had a higher co-morbidity burden, whereas women had smaller aortic root. The 30-day (device success [DS], early safety outcome, permanent pacemaker implantation, patient-prosthesis mismatch, paravalvular regurgitation, bleedings, vascular complications, and all-cause death) and 1-year outcomes (all-cause death, stroke, and heart failure hospitalization) did not differ according to gender in both valve groups. However, the male gender decreased the likelihood of 30-day DS with ULTRA versus PRO (p for interaction = 0.047). A higher risk of 30-day permanent pacemaker implantation and 1-year stroke and a lower risk of patient-prosthesis mismatch was observed in PRO versus ULTRA, regardless of gender. In conclusion, gender did not modify the treatment effect of PRO versus ULTRA on clinical outcomes, except for 30-day DS, which was decreased in men (vs women) who received ULTRA (vs PRO).


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Masculino , Femenino , Estenosis de la Válvula Aórtica/cirugía , Factores Sexuales , Anciano de 80 o más Años , Anciano , Resultado del Tratamiento , Complicaciones Posoperatorias/epidemiología , Válvula Aórtica/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA