Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 69
Filtrar
1.
J Am Coll Radiol ; 21(6S): S237-S248, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38823947

RESUMEN

This document summarizes the relevant literature for the selection of preprocedural imaging in three clinical scenarios in patients needing endovascular treatment or cardioversion of atrial fibrillation. These clinical scenarios include preprocedural imaging prior to radiofrequency ablation; prior to left atrial appendage occlusion; and prior to cardioversion. The appropriateness of imaging modalities as they apply to each clinical scenario is rated as usually appropriate, may be appropriate, and usually not appropriate to assist the selection of the most appropriate imaging modality in the corresponding clinical scenarios. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where peer reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.


Asunto(s)
Fibrilación Atrial , Medicina Basada en la Evidencia , Sociedades Médicas , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Humanos , Estados Unidos , Cuidados Preoperatorios/métodos , Cardioversión Eléctrica/métodos , Atrios Cardíacos/diagnóstico por imagen , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía
2.
Magn Reson Med ; 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38733066

RESUMEN

PURPOSE: To present and assess an outlier mitigation method that makes free-running volumetric cardiovascular MRI (CMR) more robust to motion. METHODS: The proposed method, called compressive recovery with outlier rejection (CORe), models outliers in the measured data as an additive auxiliary variable. We enforce MR physics-guided group sparsity on the auxiliary variable, and jointly estimate it along with the image using an iterative algorithm. For evaluation, CORe is first compared to traditional compressed sensing (CS), robust regression (RR), and an existing outlier rejection method using two simulation studies. Then, CORe is compared to CS using seven three-dimensional (3D) cine, 12 rest four-dimensional (4D) flow, and eight stress 4D flow imaging datasets. RESULTS: Our simulation studies show that CORe outperforms CS, RR, and the existing outlier rejection method in terms of normalized mean square error and structural similarity index across 55 different realizations. The expert reader evaluation of 3D cine images demonstrates that CORe is more effective in suppressing artifacts while maintaining or improving image sharpness. Finally, 4D flow images show that CORe yields more reliable and consistent flow measurements, especially in the presence of involuntary subject motion or exercise stress. CONCLUSION: An outlier rejection method is presented and tested using simulated and measured data. This method can help suppress motion artifacts in a wide range of free-running CMR applications.

3.
Int J Cardiovasc Imaging ; 40(5): 1081-1094, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38625629

RESUMEN

This study sought to evaluate the impact of severe obesity on image quality and ventricular function assessment in cardiovascular magnetic resonance (MRI) and trans-thoracic echocardiography (TTE). We studied 100 consecutive patients who underwent clinically indicated cardiac MRI and TTE studies within 12 months between July 2017 and December 2020; 50 (28 females and 22 males; 54.5 ± 18.7 years) with normal body mass index (BMI) (18.5-25 kg/m2) and 50 (21 females and 29 males; 47.2 ± 13.3 years) with severe obesity (BMI ≥ 40 kg/m2). MRI and TTE image quality scores were compared within and across cohorts using a linear mixed model. Categorical left (LVF) and right (RVF) ventricular function were compared using Cohens Kappa statistic. Mean BMI for normal weight and obese cohorts were 22.2 ± 1.7 kg/m2 and 50.3 ± 5.9 kg/m2, respectively. Out of a possible 93 points, mean MRI image quality score was 91.5 ± 2.5 for patients with normal BMI, and 88.4 ± 5.5 for patients with severe obesity; least square (LS) mean difference 3.1, p = 0.460. TTE scores were 64.2 ± 13.6 for patients with normal BMI and 46.0 ± 12.9 for patients with severe obesity, LS mean difference 18.2, p < 0.001. Ventricular function agreement between modalities was worse in the obese cohort for both LVF (72% vs 80% agreement; kappa 0.53 vs 0.70, obese vs. normal BMI), and RVF (58% vs 72% agreement, kappa 0.18 vs 0.34, obese vs. normal BMI). Severe obesity had limited impact on cardiac MRI image quality, while obesity significantly degraded TTE image quality and ventricular function agreement with MRI.


Asunto(s)
Índice de Masa Corporal , Ecocardiografía , Obesidad Mórbida , Valor Predictivo de las Pruebas , Función Ventricular Izquierda , Función Ventricular Derecha , Humanos , Femenino , Masculino , Persona de Mediana Edad , Adulto , Anciano , Obesidad Mórbida/complicaciones , Obesidad Mórbida/diagnóstico por imagen , Obesidad Mórbida/fisiopatología , Reproducibilidad de los Resultados , Estudios Retrospectivos , Imagen por Resonancia Magnética , Imagen por Resonancia Cinemagnética
4.
Int J Cardiovasc Imaging ; 40(2): 261-273, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38082073

RESUMEN

The electrocardiogram (ECG) signal is prone to distortions from gradient and radiofrequency interference and the magnetohydrodynamic effect during cardiovascular magnetic resonance imaging (CMR). Although Pilot Tone Cardiac (PTC) triggering has the potential to overcome these limitations, effectiveness across various CMR techniques has yet to be established. To evaluate the performance of PTC triggering in a comprehensive CMR exam. Fifteen volunteers and 20 patients were recruited at two centers. ECG triggered images were collected for comparison in a subset of sequences. The PTC trigger accuracy was evaluated against ECG in cine acquisitions. Two experienced readers scored image quality in PTC-triggered cine, late gadolinium enhancement (LGE), and T1- and T2-weighted dark-blood turbo spin echo (DB-TSE) images. Quantitative cardiac function, flow, and parametric mapping values obtained using PTC and ECG triggered sequences were compared. Breath-held segmented cine used for trigger timing analysis was collected in 15 volunteers and 14 patients. PTC calibration failed in three volunteers and one patient; ECG trigger recording failed in one patient. Out of 1987 total heartbeats, three mismatched trigger PTC-ECG pairs were found. Image quality scores showed no significant difference between PTC and ECG triggering. There was no significant difference found in quantitative measurements in volunteers. In patients, the only significant difference was found in post-contrast T1 (p = 0.04). ICC showed moderate to excellent agreement in all measurements. PTC performance was equivalent to ECG in terms of triggering consistency, image quality, and quantitative image measurements across multiple CMR applications.


Asunto(s)
Medios de Contraste , Gadolinio , Humanos , Valor Predictivo de las Pruebas , Imagen por Resonancia Magnética , Cafeína , Espectroscopía de Resonancia Magnética , Imagen por Resonancia Cinemagnética
5.
Int J Cardiovasc Imaging ; 40(1): 93-105, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37874445

RESUMEN

This study aims to evaluate the accuracy and reliability of the cardiac and respiratory signals extracted from Pilot Tone (PT) in patients clinically referred for cardiovascular MRI. Twenty-three patients were scanned under free-breathing conditions using a balanced steady-state free-precession real-time (RT) cine sequence on a 1.5T scanner. The PT signal was generated by a built-in PT transmitter integrated within the body array coil, and retrospectively processed to extract respiratory and cardiac signals. For comparison, ECG and BioMatrix (BM) respiratory sensor signals were also synchronously recorded. To assess the performances of PT, ECG, and BM, cardiac and respiratory signals extracted from the RT cine images were used as the ground truth. The respiratory motion extracted from PT correlated positively with the image-derived respiratory signal in all cases and showed a stronger correlation (absolute coefficient: 0.95 ± 0.09) than BM (0.72 ± 0.24). For the cardiac signal, PT trigger jitter (standard deviation of PT trigger locations relative to ECG triggers) ranged from 6.6 to 83.3 ms, with a median of 21.8 ms. The mean absolute difference between the PT and corresponding ECG cardiac cycle duration was less than 5% of the average ECG RR interval for 21 out of 23 patients. We did not observe a significant linear dependence (p > 0.28) of PT delay and PT jitter on the patients' BMI or cardiac cycle duration. This study demonstrates the potential of PT to monitor both respiratory and cardiac motion in patients clinically referred for cardiovascular MRI.


Asunto(s)
Técnicas de Imagen Sincronizada Cardíacas , Imagen por Resonancia Cinemagnética , Humanos , Imagen por Resonancia Cinemagnética/métodos , Estudios Retrospectivos , Reproducibilidad de los Resultados , Valor Predictivo de las Pruebas , Imagen por Resonancia Magnética , Movimiento (Física)
6.
Am J Ther ; 30(5): e447-e453, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37713689

RESUMEN

BACKGROUND: Deposition of wild-type or mutant transthyretin (TTR) amyloid fibrils in the myocardium causes TTR amyloid cardiomyopathy (ATTR-CM). Targeted therapeutics for ATTR-CM include TTR stabilizers (tafamidis and diflunisal) and oligonucleotide drugs (revusiran, patisiran, and inotersen). TTR stabilizers prevent dissociation of transthyretin tetramers. Transthyretin monomers can misfold and form amyloid fibrils. TTR stabilizers thereby limit amyloid fibrils development and deposition. Oligonucleotide drugs inhibit hepatic synthesis of transthyretin, which decreases transthyretin protein levels and thus the amyloid fibril substrate. AREAS OF UNCERTAINTY: To study the safety and efficacy of targeted therapeutics in patients with ATTR-CM, we performed a pooled analysis. A random-effects model with the Mantel-Haenszel method was used to pool the data. DATA SOURCES: A literature search was performed using PubMed, Cochrane CENTRAL, and Embase databases using the search terms "cardiac amyloidosis" AND "tafamidis" OR "patisiran" OR "inotersen" OR "revusiran" OR "diflunisal." THERAPEUTIC ADVANCES: We identified 6 studies that compared targeted therapeutics with placebo. One study was stopped prematurely because of increased mortality in the targeted therapeutics arm. Pooled analysis included 1238 patients, of which 738 patients received targeted therapeutics and 500 patients received placebo. When compared with placebo, targeted therapeutics significantly reduced all-cause mortality [OR 0.39, 95% confidence interval (CI): 0.16-0.97, P = 0.04]. Only 2 studies reported the effect on cardiovascular-related hospitalizations. There was a trend toward an improvement in global longitudinal strain (mean difference -0.69, 95% CI: -1.44 to 0.05, P = 0.07). When compared with placebo, there was no increase in serious adverse events with targeted therapeutics (OR 1.06, 95% CI: 0.78-1.44, P = 0.72). CONCLUSION: Evidence from the pooled analysis revealed targeted therapeutics improve survival and are well-tolerated. These findings suggest a potential role for targeted therapeutics in the treatment of patients with ATTR-CM.


Asunto(s)
Neuropatías Amiloides Familiares , Cardiomiopatías , Diflunisal , Humanos , Neuropatías Amiloides Familiares/tratamiento farmacológico , Prealbúmina/metabolismo , Prealbúmina/uso terapéutico , Diflunisal/farmacología , Diflunisal/uso terapéutico , Oligonucleótidos/farmacología , Oligonucleótidos/uso terapéutico , Cardiomiopatías/tratamiento farmacológico
7.
Res Sq ; 2023 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-37461505

RESUMEN

Background: The electrocardiogram (ECG) signal is prone to distortions from gradient and radiofrequency interference and the magnetohydrodynamic effect during cardiovascular magnetic resonance imaging (CMR). Although Pilot Tone Cardiac (PTC) triggering has the potential to overcome these limitations, effectiveness across various CMR techniques has yet to be established. Purpose: To evaluate the performance of PTC triggering in a comprehensive CMR exam. Methods: Fifteen volunteers and twenty patients were recruited at two centers. ECG triggered images were collected for comparison in a subset of sequences. The PTC trigger accuracy was evaluated against ECG in cine acquisitions. Two experienced readers scored image quality in PTC-triggered cine, late gadolinium enhancement (LGE), and T1- and T2-weighted dark-blood turbo spin echo (DB-TSE) images. Quantitative cardiac function, flow, and parametric mapping values obtained using PTC and ECG triggered sequences were compared. Results: Breath-held segmented cine used for trigger timing analysis was collected in 15 volunteers and 14 patients. PTC calibration failed in three volunteers and one patient; ECG trigger recording failed in one patient. Out of 1987 total heartbeats, three mismatched trigger PTC-ECG pairs were found. Image quality scores showed no significant difference between PTC and ECG triggering. There was no significant difference found in quantitative measurements in volunteers. In patients, the only significant difference was found in post-contrast T1 (p = 0.04). ICC showed moderate to excellent agreement in all measurements. Conclusion: PTC performance was equivalent to ECG in terms of triggering consistency, image quality, and quantitative image measurements across multiple CMR applications.

10.
Pacing Clin Electrophysiol ; 46(7): 745-751, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37221927

RESUMEN

BACKGROUND: Transesophageal echocardiography (TEE) and cardiac computed tomography angiography (CCTA) are currently utilized for left atrial appendage closure (LAAC) planning. During the recent global iodine contrast media shortage in 2022, cardiac magnetic resonance imaging (CMR) was utilized for the first time for LAAC planning. This study sought to assess the utility of CMR versus TEE for LAAC planning. METHODS: This single center retrospective study consisted of all patients who underwent preoperative CMR for LAAC with Watchman FLX or Amplatzer Amulet. Key measures were accuracy of LAA thrombus exclusion, ostial diameter, depth, lobe count, morphology, accuracy of predicted device size, and devices deployed per case. Bland-Altman Analysis was used to compare CMR versus TEE measurements of LAA ostial diameter and depth. RESULTS: 25 patients underwent preoperative CMR for LAAC planning. A total of 24 (96%) cases were successfully completed with 1.2 ± 0.5 devices deployed per case. Among the 18 patients who underwent intraoperative TEE, there was no significant difference between CMR versus TEE in LAA thrombus exclusion (CMR 83% vs. TEE 100% cases, p = .229), lobe count (CMR 1.7 ± 0.8 vs. TEE 1.4 ± 0.6, p = .177), morphology (p = .422), and accuracy of predicted device size (CMR 67% vs. TEE 72% cases, p = 1.000). When comparing the difference between CMR and TEE measurements, Bland-Altman analysis demonstrated no significant difference in LAA ostial diameter (CMR-TEE bias 0.7 mm, 95% CI [-1.1, 2.4], p = .420), but LAA depth was significantly larger with CMR versus TEE (CMR-TEE bias 7.4 mm, 95% CI [1.6, 13.2], p = .015). CONCLUSIONS: CMR is a promising alternative for LAAC planning in cases where TEE or CCTA are contraindicated or unavailable.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Trombosis , Humanos , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Estudios Retrospectivos , Ecocardiografía Transesofágica/métodos , Imagen por Resonancia Magnética , Trombosis/diagnóstico por imagen , Cateterismo Cardíaco , Resultado del Tratamiento
11.
Front Cardiovasc Med ; 10: 1120982, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36937932

RESUMEN

Background: Contemporary advances in low-field magnetic resonance imaging systems can potentially widen access to cardiovascular magnetic resonance (CMR) imaging. We present our initial experience in building a comprehensive CMR protocol on a commercial 0.55 T system with a gradient performance of 26 mT/m amplitude and 45 T/m/s slew rate. To achieve sufficient image quality, we adapted standard imaging techniques when possible, and implemented compressed-sensing (CS) based techniques when needed in an effort to compensate for the inherently low signal-to-noise ratio at lower field strength. Methods: A prototype CMR exam was built on an 80 cm, ultra-wide bore commercial 0.55 T MR system. Implementation of all components aimed to overcome the inherently lower signal of low-field and the relatively longer echo and repetition times owing to the slower gradients. CS-based breath-held and real-time cine imaging was built utilizing high acceleration rates to meet nominal spatial and temporal resolution recommendations. Similarly, CS 2D phase-contrast cine was implemented for flow. Dark-blood turbo spin echo sequences with deep learning based denoising were implemented for morphology assessment. Magnetization-prepared single-shot myocardial mapping techniques incorporated additional source images. CS-based dynamic contrast-enhanced imaging was implemented for myocardial perfusion and 3D MR angiography. Non-contrast 3D MR angiography was built with electrocardiogram-triggered, navigator-gated magnetization-prepared methods. Late gadolinium enhanced (LGE) tissue characterization methods included breath-held segmented and free-breathing single-shot imaging with motion correction and averaging using an increased number of source images. Proof-of-concept was demonstrated through porcine infarct model, healthy volunteer, and patient scans. Results: Reasonable image quality was demonstrated for cardiovascular structure, function, flow, and LGE assessment. Low-field afforded utilization of higher flip angles for cine and MR angiography. CS-based techniques were able to overcome gradient speed limitations and meet spatial and temporal resolution recommendations with imaging times comparable to higher performance scanners. Tissue mapping and perfusion imaging require further development. Conclusion: We implemented cardiac applications demonstrating the potential for comprehensive CMR on a novel commercial 0.55 T system. Further development and validation studies are needed before this technology can be applied clinically.

12.
JACC Cardiovasc Imaging ; 16(5): 609-624, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36752429

RESUMEN

BACKGROUND: Myocardial injury in patients with COVID-19 and suspected cardiac involvement is not well understood. OBJECTIVES: The purpose of this study was to characterize myocardial injury in a multicenter cohort of patients with COVID-19 and suspected cardiac involvement referred for cardiac magnetic resonance (CMR). METHODS: This retrospective study consisted of 1,047 patients from 18 international sites with polymerase chain reaction-confirmed COVID-19 infection who underwent CMR. Myocardial injury was characterized as acute myocarditis, nonacute/nonischemic, acute ischemic, and nonacute/ischemic patterns on CMR. RESULTS: In this cohort, 20.9% of patients had nonischemic injury patterns (acute myocarditis: 7.9%; nonacute/nonischemic: 13.0%), and 6.7% of patients had ischemic injury patterns (acute ischemic: 1.9%; nonacute/ischemic: 4.8%). In a univariate analysis, variables associated with acute myocarditis patterns included chest discomfort (OR: 2.00; 95% CI: 1.17-3.40, P = 0.01), abnormal electrocardiogram (ECG) (OR: 1.90; 95% CI: 1.12-3.23; P = 0.02), natriuretic peptide elevation (OR: 2.99; 95% CI: 1.60-5.58; P = 0.0006), and troponin elevation (OR: 4.21; 95% CI: 2.41-7.36; P < 0.0001). Variables associated with acute ischemic patterns included chest discomfort (OR: 3.14; 95% CI: 1.04-9.49; P = 0.04), abnormal ECG (OR: 4.06; 95% CI: 1.10-14.92; P = 0.04), known coronary disease (OR: 33.30; 95% CI: 4.04-274.53; P = 0.001), hospitalization (OR: 4.98; 95% CI: 1.55-16.05; P = 0.007), natriuretic peptide elevation (OR: 4.19; 95% CI: 1.30-13.51; P = 0.02), and troponin elevation (OR: 25.27; 95% CI: 5.55-115.03; P < 0.0001). In a multivariate analysis, troponin elevation was strongly associated with acute myocarditis patterns (OR: 4.98; 95% CI: 1.76-14.05; P = 0.003). CONCLUSIONS: In this multicenter study of patients with COVID-19 with clinical suspicion for cardiac involvement referred for CMR, nonischemic and ischemic patterns were frequent when cardiac symptoms, ECG abnormalities, and cardiac biomarker elevations were present.


Asunto(s)
COVID-19 , Enfermedad de la Arteria Coronaria , Lesiones Cardíacas , Miocarditis , Humanos , Miocarditis/patología , COVID-19/complicaciones , Estudios Retrospectivos , Valor Predictivo de las Pruebas , Imagen por Resonancia Magnética , Troponina , Espectroscopía de Resonancia Magnética
13.
JACC Case Rep ; 4(10): 567-575, 2022 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-35373150

RESUMEN

A 60-year-old woman with a past medical history of asthma presented with fulminant myocarditis 9 days after testing positive for SARS-CoV-2 and 16 days after developing symptoms consistent with COVID-19. Her hospital course was complicated by the need for veno-arterial extracorporeal membrane oxygenation, ventricular arrhythmias, and pseudomonas bacteremia. She ultimately recovered and was discharged to home with normal left ventricular systolic function. Thereafter, she developed symptomatic ventricular tachycardia, for which she received an implantable cardioverter-defibrillator and antiarrhythmic drug therapy.

14.
J Am Coll Cardiol ; 79(21): 2144-2152, 2022 05 31.
Artículo en Inglés | MEDLINE | ID: mdl-35364210

RESUMEN

A 60-year-old woman with a past medical history of asthma presented with fulminant myocarditis 9 days after testing positive for SARS-CoV-2 and 16 days after developing symptoms consistent with COVID-19. Her hospital course was complicated by the need for veno-arterial extracorporeal membrane oxygenation, ventricular arrhythmias, and pseudomonas bacteremia. She ultimately recovered and was discharged to home with normal left ventricular systolic function. Thereafter, she developed symptomatic ventricular tachycardia, for which she received an implantable cardioverter-defibrillator and antiarrhythmic drug therapy.


Asunto(s)
COVID-19 , Oxigenación por Membrana Extracorpórea , Miocarditis , Arritmias Cardíacas/complicaciones , COVID-19/complicaciones , Vías Clínicas , Femenino , Humanos , Persona de Mediana Edad , Miocarditis/diagnóstico , Miocarditis/etiología , Miocarditis/terapia , SARS-CoV-2
15.
Open Heart ; 9(1)2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35246499

RESUMEN

OBJECTIVES: While cardiac amyloidosis (CA) classically involves the left ventricle (LV), less is known about its impact on the right ventricle (RV) and pulmonary vasculature. We performed a retrospective analysis to identify the prevalence and types of pulmonary hypertension (PH) profiles in CA and to determine haemodynamic and cardiovascular magnetic resonance (CMR) predictors of major adverse cardiovascular events (MACE). METHODS: Patients with CA who underwent CMR and right heart catheterisation (RHC) within 1 year between 2010 and 2019 were included. Patients were assigned the following haemodynamic profiles based on RHC: no PH, precapillary PH, isolated postcapillary PH (IPCPH), or combined precapillary and postcapillary PH (CPCPH). The relationship between PH profile and MACE (death, heart failure hospitalisation) was assessed using survival analysis. CMR and RV parameters were correlated with MACE using Cox-regression analysis. RESULTS: A total of 52 patients were included (age 69±9 years, 85% men). RHC was performed during biopsy in 44 (85%) and for clinical indications in 8 (15%) patients. Rates of no PH, precapillary PH, IPCPH and CPCPH were 5 (10%), 3 (6%), 29 (55%) and 15 (29%), respectively. Haemodynamic PH profile did not correlate with risk of death (p=0.98) or MACE (p=0.67). Transpulmonary gradient (TPG) (HR 0.88, CI 0.80 to 0.97), RV, (HR 0.95, CI 0.92 to 0.98) and LV ejection fraction (HR 0.95, CI 0.92 to 0.98) were significantly associated with MACE. CONCLUSIONS: PH is highly prevalent in CA, even at the time of diagnosis. While IPCPH was most common, CPCPH is not infrequent. TPG and RV ejection fraction (RVEF) are prognostic markers in this population.


Asunto(s)
Amiloidosis , Hipertensión Pulmonar , Anciano , Amiloidosis/diagnóstico , Amiloidosis/epidemiología , Femenino , Hemodinámica , Humanos , Hipertensión Pulmonar/diagnóstico , Hipertensión Pulmonar/epidemiología , Hipertensión Pulmonar/etiología , Masculino , Persona de Mediana Edad , Prevalencia , Estudios Retrospectivos
16.
Immunotherapy ; 14(7): 511-520, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35321560

RESUMEN

Immune checkpoint inhibitors have been incorporated into the treatment of various malignancies. An increasing body of literature is reporting rare but potentially fatal adverse events associated with these agents. In this case series, the authors report the clinical features and outcomes of seven patients who received immune checkpoint inhibitors for different solid organ malignancies and developed a tetrad of immune-related myocarditis, myositis, myasthenia gravis and transaminitis. Herein the authors review the literature and describe the current diagnostic and management approach for this overlapping syndrome. The authors' series highlights the importance of a high index of clinical suspicion, prompt comprehensive investigations, early multidisciplinary team involvement and initiation of immunosuppressive therapy when immune-related adverse events are suspected.


Cancer immunotherapy is used in the treatment of different cancer types. Immunotherapy activates the immune system to detect and attack cancer cells, but side effects may arise from the immune system inadvertently attacking normal tissues and organs. The increased use of immunotherapy has led to an increase in the reporting of rare but potentially life-threatening treatment-related side effects. In this case series, the authors report the clinical features and outcomes of seven patients who developed inflammation of the heart, muscles, nerve and muscle junctions and liver following treatment with immunotherapy. The authors review the scientific literature and discuss the current understanding of and management approach to this rare syndrome. The authors' report highlights the importance of a high degree of clinical suspicion, prompt comprehensive testing to confirm diagnosis, early involvement of experts from different specialties and early initiation of treatment in the management of this unique syndrome.


Asunto(s)
Miastenia Gravis , Miocarditis , Miositis , Neoplasias , Humanos , Inhibidores de Puntos de Control Inmunológico/efectos adversos , Miastenia Gravis/inducido químicamente , Miocarditis/inducido químicamente , Miocarditis/diagnóstico , Miocarditis/tratamiento farmacológico , Miositis/inducido químicamente , Miositis/diagnóstico , Neoplasias/tratamiento farmacológico
17.
Kidney Int Rep ; 7(1): 56-67, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35005314

RESUMEN

INTRODUCTION: Patients with glomerular disease experience symptoms that impair their physical and mental health while managing their treatments, diet, appointments and monitoring general and specific indicators of health and their illness. We sought to describe the perspectives of patients and their care partners on self-management in glomerular disease. METHODS: We conducted 16 focus groups involving adult patients with glomerular disease (n = 101) and their care partners (n = 34) in Australia, Hong Kong, the United Kingdom, and United States. Transcripts were analyzed thematically. RESULTS: We identified the following 4 themes: empowered in autonomy (gaining confidence through understanding, taking ownership of disease and treatment, learning a positive health approach); overwhelmed by compounding treatment burdens (financially undermined and depleted, demoralized by side effects and harms, frustrated by fragmented and inflexible care, fear of possible drug harms); striving for stability and normalcy (making personal sacrifices, maximizing life participation, attentiveness to bodily signs, avoiding precarious health states, integrating medicines into routines); and necessity of health-sustaining relationships (buoyed by social support, fulfilling meaningful responsibilities, sharing and normalizing experiences, seeking a trusting and respectful alliance). CONCLUSION: Patients with glomerular disease and their care partners value their capacity for autonomy and disease ownership, stability of their health, and relationships that support self-management. Strategies directed at strengthening these factors may increase self-efficacy and improve the care and outcomes for patients with glomerular disease.

18.
Magn Reson Med ; 87(3): 1595-1604, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34719067

RESUMEN

PURPOSE: To develop an automatic method for selecting heartbeats with consistent respiratory phase to improve accuracy of cardiac function quantification in real-time (RT) cardiac MRI. METHODS: The respiratory signal is extracted by a principal component analysis method from RT cine images. Then, a two-step procedure is used to determine the directionality (sign) of the respiratory signal. With the motion in a manually selected region-of-interest as a reference, the quality of the extracted respiratory signal is assessed using multislice RT cine data from 11 volunteers and 10 patients. In addition, the impact of selecting heartbeats with consistent respiratory phase on the cardiac function quantification is evaluated. RESULTS: The extracted respiratory signal using the proposed method exhibits a high, positive correlation with the reference in all cases and is more robust compared to a recently proposed method. Also, for right ventricular function quantification, selecting heartbeats at expiratory position improves agreement between RT cine and breath-held reference. CONCLUSION: The proposed method enables fully automatic extraction and directionality determinations of respiratory signal from RT cardiac cine images, allowing accurate cardiac function quantification.


Asunto(s)
Interpretación de Imagen Asistida por Computador , Imagen por Resonancia Cinemagnética , Contencion de la Respiración , Corazón/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética
19.
Cureus ; 14(12): e32232, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36620794

RESUMEN

Lumbar epidural fibrosis may occur after a lumbar discectomy, replacing normal epidural fat with non-physiologic scar tissue, binding the dura and nerve roots to the surrounding structures, and causing arachnoiditis. Lumbar arachnoiditis occurs in 6%-16% of postoperative surgeries in the lumbar region, usually at the site of the laminectomy into the spinal canal. This case report covers a 35-year-old male patient who underwent a discectomy with resulting arachnoiditis multiple levels cranial of the site of laminectomy. We illustrate the first reported case of diffuse arachnoiditis causing residual pain after a lumbar discectomy.

20.
Clin Transl Radiat Oncol ; 31: 71-79, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34646951

RESUMEN

Cardiac radioablation with SBRT is a very promising non-invasive modality for the treatment of refractory VT and potentially other cardiac arrhythmias. Initial reports indicate that it is relatively safe and associated with excellent responses, particularly in reduction of ICD-related events, need for anti-arrhythmic medications, and resulting in significantly improved quality of life for patients. Establishment of objective criteria for candidates for cardiac radioablation will accelerate the adoption of this important radiation therapy modality in the treatment of refractory VT and other cardiac arrhythmias in the coming years. In addition, in order to develop more prospective safety and efficacy data, treatment of patients should ideally be performed in the context of clinical trials or prospective registries at, or in collaboration with, experienced centers. Taken together, the future of cardiac radioablation is rich and worthy of further investigation to become a standard treatment in the armamentarium against refractory VT.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...