Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 92(1): 78-87, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29602248

RESUMEN

OBJECTIVE: To determine the consequences of an early catheter-based intervention on pulmonary artery (PA) growth and right ventricular (RV) myocardial function in an animal model of branch PA stenosis. BACKGROUND: Acute results and safety profiles of deliberate stent fracture within the pulmonary vasculature have been demonstrated. The long-term impact of early stent intervention and deliberate stent fracture on PA growth and myocardial function is not understood. METHODS: Implantation of small diameter stents was performed in a pig model of left PA stenosis at 6 weeks (10 kg) followed by dilations at 10 (35 kg) and 18 weeks (65 kg) with intent to fracture and implant large diameter stents. Hemodynamics, RV contractility, and 2D/3D angiography were performed with each intervention. The heart and pulmonary vasculature were histologically assessed. RESULTS: Stent fracture occurred in 9/12 and implantation of large diameter stents was successful in 10/12 animals with no PA aneurysms or dissections. The final stented PA segment and distal left PA branch origins equaled the corresponding PA diameters of sham controls. Growth of left PA immediately beyond the stent was limited and there was diffuse fibro-intimal proliferation within the distal left and right PA. RV contractility was diminished in the intervention group and the response to dobutamine occurred uniquely via increases in heart rate. CONCLUSIONS: Early stent intervention in this surgically created PA stenosis model was associated with improved growth of the distal PA vasculature but additional investigation of PA vessel physiology and impact on the developing heart are needed.


Asunto(s)
Cateterismo de Swan-Ganz/métodos , Intervención Médica Temprana/métodos , Contracción Miocárdica , Arteria Pulmonar/crecimiento & desarrollo , Estenosis de Arteria Pulmonar/terapia , Función Ventricular Derecha , Animales , Animales Recién Nacidos , Cateterismo de Swan-Ganz/instrumentación , Modelos Animales de Enfermedad , Hemodinámica , Diseño de Prótesis , Falla de Prótesis , Arteria Pulmonar/patología , Estenosis de Arteria Pulmonar/diagnóstico por imagen , Estenosis de Arteria Pulmonar/patología , Estenosis de Arteria Pulmonar/fisiopatología , Stents , Sus scrofa , Factores de Tiempo
2.
Pediatr Cardiol ; 37(1): 24-9, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26215767

RESUMEN

The aims of this study were to quantify patient radiation exposure for a single interventional procedure during transition from an adult catheterization laboratory to a next-generation imaging system with pediatric settings, and to compare this radiation data to published benchmarks. Radiation exposure occurs with any X-ray-directed pediatric catheterization. Technologies and imaging techniques that limit dose while preserving image quality benefit patient care. Patient radiation dose metrics, air kerma, and dose-area product (DAP) were retrospectively obtained for patients <20 kg who underwent patent ductus arteriosus (PDA) closure on a standard imaging system (Group 1, n = 11) and a next-generation pediatric imaging system (Group 2, n = 10) with air-gap technique. Group 2 radiation dose metrics were then compared to published benchmarks. Patient demographics, procedural technique, PDA dimensions, closure devices, and fluoroscopy time were similar for the two groups. Air kerma and DAP decreased by 65-70% in Group 2 (p values <0.001). The average number of angiograms approached statistical significance (p value = 0.06); therefore, analysis of covariance (ANCOVA) was conducted that confirmed significantly lower dose measures in Group 2. This degree of dose reduction was similar when Group 2 data (Kerma 28 mGy, DAP 199 µGy m(2)) was compared to published benchmarks for PDA closure (Kerma 76 mGy, DAP 500 µGy m(2)). This is the first clinical study documenting the radiation reduction capabilities of a next-generation pediatric imaging platform. The true benefit of this dose reduction will be seen in patients requiring complex and often recurrent catheterizations.


Asunto(s)
Cateterismo Cardíaco/métodos , Conducto Arterioso Permeable/diagnóstico por imagen , Conducto Arterioso Permeable/cirugía , Dosis de Radiación , Protección Radiológica/métodos , Adulto , Preescolar , Fluoroscopía , Humanos , Lactante , Recién Nacido , Pediatría , Exposición a la Radiación , Radiografía Intervencional , Estudios Retrospectivos , Medición de Riesgo , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...