Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Hazard Mater ; 469: 133981, 2024 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-38461666

RESUMEN

Pyrolysis-gas chromatography coupled to Orbitrap-mass spectrometry is a novel technique that allows the low level and precise determination of microplastics in environmental samples. In this paper, we develop and assess the target and untargeted performance of Pyr-GC-Orbitrap-MS. The method was optimized for 10 plastic polymers: polymethyl methacrylate, nylon-6,6, polypropylene, nitrile butadiene rubber, polyvinyl chloride, polyethylene terephthalate, acrylonitrile butadiene styrene, polyethylene, polycarbonate, and polystyrene. Standards were home-made using a diamond driller to attain mean sizes within the range of 45-382 µm. A step-by-step optimization of the analytical procedure was carried out. First, accurate mass measurement of each polymer at 60,000 resolution was studied to select the 3 most intense and selective quantification and confirmation ions. Second, internal standard quantification was optimized, and good linearity, repeatability, and reproducibility were obtained. Blank contribution and instrumental detection limit were evaluated for each polymer. Finally, the combined and expanded uncertainty of the Pyr-GC-Orbitrap-MS method was calculated to determine the sources of variation, considering that home-made standards were used. To evaluate method performance, targeted and non-targeted analysis of indoor air samples collected from gyms and department stores were carried out. The Pyr-GC-Orbitrap-MS methodology herein described can be applied for the quantitative assessment of MPs and other substances in different matrices.

2.
Molecules ; 27(20)2022 Oct 13.
Artículo en Inglés | MEDLINE | ID: mdl-36296451

RESUMEN

Since the outbreak of COVID-19, face masks have been introduced in the complex strategy of infection prevention and control. Face masks consist of plastic polymers and additives such as phthalates. The aim of this study was to evaluate the migration of microplastics (MP) and phthalates from face masks to water. Four types of masks including FFP2 masks and surgical were studied. Masks were first characterized to determine the different layers and the material used for their fabrication. Then, masks were cut into 20 pieces of 0.5 cm2, including all their layers, placed in water, and the migration of MP and phthalates was evaluated according to the conditions stated in EU Regulation No 10/2011 on plastic materials and articles intended to come into contact with food. For MP, the morphological analysis (shape, dimension, particle count) was performed using a stereomicroscope, while the identification of both masks and MP released was conducted using µ-Fourier-transform infrared spectroscopy (µ-FT-IR). Migration of phthalates was assessed by ultra-high-performance liquid chromatography coupled to triple quadrupole mass spectrometer (UPLC-MS/MS). Face masks analyzed in the present study were made of atactic polypropylene (PP) as stated by the manufacturer. The µ-FT-IR confirmed that PP and polyamide (PA) were released as fragments, while both PP and polyester (PES) were released as fibers. In addition, 4 phthalates were identified at concentrations between 2.34 and 21.0 µg/mask. This study shows that the migration study can be applied to evaluate the potential release of MP and phthalates from face masks to water and could give a hint for the potential impact of their incorrect disposal on the aquatic resources.


Asunto(s)
COVID-19 , Microplásticos , Humanos , Plásticos/química , Máscaras , Agua , Espectroscopía Infrarroja por Transformada de Fourier , Polipropilenos/análisis , Nylons , Cromatografía Liquida , COVID-19/epidemiología , COVID-19/prevención & control , Espectrometría de Masas en Tándem , Poliésteres/análisis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...