Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Clin Cardiol ; 42(10): 952-957, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31407351

RESUMEN

BACKGROUND: Cardiac telemetry monitoring is widely utilized for a variety of clinical indications, yet indication-specific event rates for monitored patients are seldomly reported. HYPOTHESIS: High-risk hospitalized patients for clinical deterioration can be identified using standardized telemetry monitoring indications. METHODS: Adjudicated data from events triggering emergency response team (ERT) activation were systematically characterized at the Cleveland Clinic from among standardized telemetry indications ordered over a 13-month period. RESULTS: Among 72 199 orders created for telemetry monitored patients, ERT activation occurred in 2677 patients (3.7%), of which 1326 (49.5%) were cardiac-related. Patients with deep venous thrombosis or pulmonary embolism (DVT/PE) demonstrated the highest overall event rate (ERT: n = 41 of 593 pts [6.9%]; 25/41 cardiac related [61%]). Cardiac-related events were proportionally highest among patients with coronary disease awaiting revascularization (ERT: n = 19 of 847 patients [2.2%]; 13/19 cardiac-related [68.4%]). Arrhythmia-specific events were highest among patients who underwent cardiac surgery (n = 78 of 193 cardiac-related ERT [40.4%]), and patients with known or suspected tachyarrhythmias (n = 318 of 788 cardiac-related ERT [40.4%]). Bubble plot analysis identified patients hospitalized with DVT/PE, drug or alcohol exposures, and acute coronary syndrome as among the highest overall and cardiac-related events while identifying patients with respiratory disorder monitoring indications as carrying the highest noncardiac event rate. CONCLUSION: High-risk hospitalized patients can be identified by telemetry indication and prioritized according to concerns for cardiac, arrhythmia-specific and noncardiac clinical deterioration. This is particularly useful when monitored bed resources are constrained.


Asunto(s)
Enfermedades Cardiovasculares/diagnóstico , Servicio de Urgencia en Hospital , Monitoreo Fisiológico/métodos , Telemetría/métodos , Enfermedades Cardiovasculares/epidemiología , Estudios de Seguimiento , Humanos , Incidencia , Ohio/epidemiología , Estudios Retrospectivos
2.
J Innov Card Rhythm Manag ; 10(9): 3803-3808, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32477749

RESUMEN

Research on traditional cardiac telemetry demonstrates that excessive alarms are related to lead failures and noise-related interruptions. Patch-based continuous cardiac rhythm monitoring (CCRM) has emerged in outpatient ambulatory monitoring situations as a means to improve recording fidelity. In this study, patients hospitalized but not in the intensive care unit were simultaneously monitored via telemetry in parallel with the use of the Vital Signs Patch™ (VSP) CCRM system (LifeWatch Services, Rosemont, IL, USA), applying standardized monitoring and notifications provided by an off-site central monitoring unit (CMU). Among 11 patients (55% male; age: 66.8 ± 12.5 years), there were 42 CMU detections and 98 VSP detections. The VSP device was successfully applied by nursing with connectivity established in all 11 patients (100%). There were no VSP device-related adverse events or skin eruptions during the study. The CMU agreed with 59 (60%) of 98 VSP detections. Among those detections marked by disagreement 30 (77%) of 39 VSP detections were related to clinically meaningful arrhythmias (atrial: n = 9; ventricular: n = 7; brady-: n = 14) undetected by VSP due to noise. In two patients (18%), there were four clinically meaningful atrial fibrillation detections not recorded by the CMU. In conclusion, patch-based CCRM requires further development and review to replace traditional cardiac telemetry monitoring but could evolve into an appropriate method to detect clinically meaningful events missed by traditional methods if noise issues can be mitigated.